Search NASA⌕ Search

SEARCH · Search NASA

Results for “control simulation testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Implementing a Hardware Testbed Using 3-Level ANPC Software Defined Inverters for Fault Analysis of a Transmission Network

In this paper, we propose the implementation of a hardware testbed using 3-level active neutral point clamped (ANPC) software-defined inverters for fault analysis. A test case transmission network equipped with two grid forming (GFM) inverters and four resistive loads is considered in this research. Firstly, grid forming control laws including PI feedback control and droop control are implemented to operate the inverters in parallel. Then, we implement a fault ride-through (FRT) logic and perform a simulation of the test system by applying a three-phase fault. Simulation results show the effectiveness of the fault recovery algorithm upon clearance of the fault. Finally, a 3-level ANPC software-defined inverter is programmed with required control laws and characterized through various lab experiments.

3-level ANPC inverter↗

Pareto-optimal target definition for multi-axis random vibration testing

In random vibration testing with multiple control channels, existing control laws require specification of a complete spectral density matrix at each control frequency. Spectral density matrices include autospectral densities on the diagonal and cross-spectral densities on the off-diagonal. In practice, the off-diagonal terms are often unknown, and recent vibration testing research has focused on fixing the diagonal and specifying the off-diagonal to minimize the required control energy, subject to a constraint that the target matrix is positive semidefinite. This paper shows that, even with a fixed diagonal, off-diagonal terms strongly affect control residuals. This overlooked effect occurs in both square and rectangular systems. By jointly considering input energy and control residuals, open-loop inputs are derived directly from the diagonal without specifying the off-diagonal terms. Vibration targets that can be used in closed-loop control are then derived using the optimal inputs, with positive semidefinite constraints applied during the derivation. The result is a set of Pareto-optimal control solutions. For each solution in the set, any other possible solution produces greater control error, greater input energy, or both. A balanced solution is selected automatically, though others can be chosen based on test needs. Simulations and experiments show that the proposed method outperforms state-of-the-art energy-minimizing approaches, achieving significant reductions in both control error and input energy.

Autospectral density↗

Deep Learning-enhanced Block-Diagram Modeling of Solar Power Systems

Data-driven models of power system inverter-based resources are desired to run simulations faster than with detailed electromagnetic transient models, to hide proprietary design details, to support control system design applications, and to aggregate the effects of distributed energy resources. This paper applies a customized Hammerstein Wiener framework to train block diagram models from thousands of electromagnetic transient simulations or experimental test records. The block diagram models integrate with larger grid simulations as voltagecontrolled current sources or current-controlled voltage sources for several simulators. Guidelines for block architecture and training are presented. Three-phase balanced, three-phase unbalanced, and single-phase examples all achieve an acceptable root mean square error of no more than 0.05 per-unit.

Mcdermott, Thomas E. [Private consulting company]↗

Study of the Protection Improvements for a Weak Grid Area With High Inverter-Based Resources (IBRs)

This project designs enhanced protection scheme for the real-world weak grid area with a high penetration of IBRs. As the existing protection schemes are originally designed for traditional synchronous machines, we first evaluate if the protection scheme will continue to operate reliably in systems with high levels of IBRs. Hardware relays are tested using a controller-hardware-in-the-loop setup. PSCAD electromagnetic transient simulation with IBR original equipment manufacturer black-box models is used to perform fault studies and generate COMTRADE data, which are replayed by a real-time digital simulator (RTDS) to feed input to the hardware relays. Three scenarios are analyzed: normal operation, an N-1 contingency, and an IBR-only scenario. The evaluation results reveal the following: 1) the protection scheme remains reliable under normal conditions and N-1 contingencies and 2) in IBR-only scenarios, differential protection (87L) continues to operate reliably, whereas local protection elements, such as distance and directional elements, fail because of the lack of regulated negative sequence current contributed by IBRs. Enhanced protection is designed to address the challenge of lack of negative sequence current from IBRs, including increased restraining factors a2 and k2 to block 32Q or using V instead QV ORDER for ground faults, enhanced mho distance element with voltage and phase angle supervision for L-L faults. The efficacy of enhanced protection logic is validated and proven to work reliably. Additionally, IEEE Std. 2800-2022 negative sequence current compliant GFL and GFM IBRs from another vendor are tested and proven to work reliably without need for enhanced logic. Therefore, this work provides valuable decision-making for utilities facing protection system challenges due to IBRs, either designing enhanced protection scheme or requesting their IBRs being IEEE Std. 2800-2022 compliant to produce regulated negative sequence current for protection relay to make correct decision.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Update on Microreactor Automated Control System (MACS)

Automation of control systems is expected to be important in the economic and safe operation of microreactors. There is a need to develop and demonstrate automated control for microreactors, along with the development of testbeds for this purpose. This report provides updates on the status of a microreactor automated control system (MACS) testbed developed to test control system automation. While a future goal is to demonstrate this system using a prototypic microreactor such as MARVEL, the present focus is on developing and testing within a non-nuclear testbed. The testbed, developed in collaboration with Idaho National Laboratory, includes hardware-in-the-loop simulation and uses a Modelica-based model of a prototypic microreactor for use in testing control automation. Research to date at Oak Ridge National Laboratory has focused on the development of prototypic software for automating plant-level control under selected scenarios. Empirical testing on the integrated MACS testbed was performed to quantify key characteristics of the integrated testbed and to demonstrate the use of the software for automating the calculation and use of actuation setpoints for selected load-following scenarios. Ongoing research is focused on integrating additional control algorithms that utilize data from newly included sensors within the MACS hardware testbed, as well as demonstrating and assessing the performance of the different automated control algorithms on multiple additional operational scenarios.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Intelligent Hierarchical Resilient Operation of Distribution Systems: Implementation and Validation in a Power Hardware-in-the-Loop Simulation Testbed

This paper reports on the structure of a power hardware-in-the-loop (PHIL) simulation testbed that implements, tests, and validates a novel AI-based hierarchical resilient operation model for distribution systems. The testbed implements the central and distributed controllers of the hierarchical resilient operation model and integrates a Digital Real-Time Simulator (DRTS), protective relays, a Real-Time Automation Controller (RTAC), a Software Defined Network (SDN) switch, and a battery energy storage (BES) system. The testbed provides comprehensive real-time visualization and monitoring capability as an advanced situational awareness and operator interface solution. The IEEE 33-node system is used as a test case to test and validate the operation of the model in normal operation and recovery operation after major outages in a fully automated fashion.

Ganjkhani, Mehdi↗

Machine Learning-Based PV Reserve Determination Strategy for Frequency Control on the WECC System

This paper proposes a machine learning based strategy, that is suitable for real-time operation, to determine the optimal photovoltaic (PV) power plants reserve for frequency control. The proposed machine learning algorithm is trained and tested on 1,987 offline simulations of a 60% renewable penetration Western Electricity Coordinating Council (WECC) system. On a realistic 1-day operation profile of the WECC system, the ML model demonstrates a savings of more than 40% PV headroom compared to a conservative approach.

14 SOLAR ENERGY↗

Experimental Technetium Release from Simulated Salt-stone Cementitious Waste Form - 18419

Experiments are being conducted to evaluate the early release of technetium (Tc) from fresh salt-stone waste forms using dynamic flow-through tests. Salt-stone is a chemically reducing, grout-based waste form used by the U.S. Department of Energy (DOE) to dispose of low-activity salt solutions arising from high-level radioactive waste tank closure activities at the Savannah River Site (SRS). A key safety function of salt-stone is maintaining a low-flow, chemically reducing environment that will attenuate the release of redox-sensitive radioelements such as Tc. Salt-stone also provides a physical barrier due to its low intrinsic permeability, which limits both water and oxygen ingress. These release experiments, conducted to support the U.S. Nuclear Regulatory Commission's monitoring role during tank closure, are designed to provide independent information on how well salt-stone will perform its safety function. The dynamic leach tests were conducted in a Hassler-type core-holder permeameter system that allows an accelerated flow rate of simulated SRS groundwater through an intact cylinder of salt-stone spiked with Tc-99 at a concentration of approximately 2,100 Bq/g (3 ppm). The first salt-stone specimen to be tested (Specimen 2) was prepared with Grade 100 ground granulated blast-furnace slag and aged for 119 days in a temperature-controlled, low-oxygen, high-humidity environment. Before test completion, 9.5 pore volumes (PV) of simulated SRS groundwater were passed through the salt-stone cylinder. After a few PV, apparent saturated hydraulic conductivity (K{sub sat}) values calculated from flow data reached a steady-state value of approximately 1.0 x 10{sup -9} cm/s, which is within the range of previously reported data. Tc-99 concentrations in leachate peaked early during the leach test at 2.0 x 10{sup -7} M and then declined to approximately 4 x 10{sup -8} M after 9.5 PV. The leachate Tc-99 concentration after elution of 9.5 PV is broadly consistent with a Tc solution concentration controlled by the solubility of reduced Tc solids. The range of Tc-99 concentrations is similar to the range reported for a column test that was sponsored by DOE, but the time pattern of release differs. The second salt-stone specimen tested (Specimen 3) was aged for 372 days and it further differed from the first specimen in that its Grade 100 slag component had been finely ground using a mortar and pestle in an attempt to make it more reactive. This second test yielded Tc release behavior broadly similar to that observed during the first test, except that the early Tc peak (at 1.2 x 10{sup -6} M) was six times higher and the concentration after 6.7 PV (8.8 x 10{sup -8} M) was approximately two times higher than in the first test. In addition, the steady-state K{sub sat} was an order of magnitude lower than that of the first specimen. During the second test, the injection pump was intentionally turned off for a period of 11 days (i.e., approximate residence time for 1 PV) and a Tc spike was observed when pumping resumed, suggesting that longer residence times may promote higher Tc effluent concentrations. During a second intentional shut-down of the pump for 25 days (approximate residence time for 2 PV), another Tc spike was observed. An unplanned excursion to higher confining pressure physically affected the specimen, temporarily lowering the apparent K{sub sat} followed by a subsequent increase in both K{sub sat} and Tc effluent concentration. One hypothesis is that the transient spike in confining pressure and resulting salt-stone compression and later decompression may have induced Tc release from otherwise inactive pores. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wind/Wave Testing of a 1:70-Scale Performance-Matched Model of the IEA Wind 15 MW Reference Wind Turbine with Real-Time ROSCO Control and Floating Feedback

Experimental results from the Floating Offshore-wind and Controls Advanced Laboratory (FOCAL) experimental program, which tested a performance-matched model of the IEA Wind 15 MW Reference Turbine on a 1:70 scale floating semisubmersible platform, are compared with OpenFAST simulations. Four experimental campaigns were performed, and data from the fourth campaign, which focused on wind and wave testing of the scaled floating wind turbine system, are considered. Simulations of wave-only, wind-only, and wind/wave environments are performed in OpenFAST, and results for key metrics are compared with the experiment. Performance of the real-time Reference OpenSource COntroller (ROSCO) in above-rated wind conditions, including the effects of the floating feedback loop, are investigated. Results show good agreement in mean values for key metrics, and hydrodynamic effects are matched well. Differences in the surge resonant behavior of the platform are identified and discussed. The effect of the controller and floating feedback loop is evident in both the experiment and OpenFAST, showing significant reduction in platform pitch response and tower base bending load near the platform pitch natural frequency.

17 WIND ENERGY↗

Development and Demonstration of a Reduced-Order PWR Power Dispatch Simulator

This report describes the development, modeling, and results of a reduced-order thermal power dispatch pressurized water reactor (RO-TPD-PWR) power plant simulator that incorporates coupled electrical and thermal power dispatch to an industrial process. The simulator is built on models that have been developed in previous work, including a Rancor Microworld model previously developed by INL and the University of Idaho [Ref] and reactor core and secondary system models that have been published previously [Ref]. The simulator also includes a scalable model of a high temperature electrolysis (HTE) system that has been developed at INL. A particular benefit of the Rancor Microworld model is that it is compatible with a human-system interface (HMI) that has already been developed by the Human System Simulation Laboratory (HSSL) at INL that can emulate the control room of a PWR for realistic human-in-the-loop studies with mock nuclear power plant operating procedures. The results of these human-in-the-loop tests will be compared with similar tests using a commercial full-scope generic PWR (GPWR) simulator that has been modified to include thermal power dispatch, referred to as the TPD-GPWR [ , ]. The simplicity of the RO-TPD-PWR helps to better understand and verify the results of the TPD-GPWR, which employs >1,000 variables and has much greater complexity. A second key purpose of the RO-TPD-PWR simulator is that its relative simplicity allows it scale between lab-size equipment (~100 kW) and full-scale nuclear power plants (~1 GW) by adjusting only a few parameters in the models, such as fluid masses and heat exchanger areas. The RO-TPD-PWR simulator will be used to guide the controls of lab tests, so that equipment in those tests, such as the Thermal Energy Distribution System (TEDS) and pilot-scale high temperature electrolysis (HTE) units at scales of 50-250 kW, may operate in a manner that is relevant to full-scale PWR operations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Co-simulation of transactive energy markets: A framework for market testing and evaluation

The proliferation of distributed energy resources (DER)—and the ability to intelligently control these assets—is re-defining the electrical distribution system. As the number of controllable devices rapidly expands, grid operators must determine how to incorporate these assets while delivering reliable, equitable, and affordable electricity. One possible approach is to establish distribution-level electricity markets and allow devices/aggregations of devices to participate in price establishment. While this approach purports some of the same benefits as the highly successful wholesale electricity markets (i.e., open competition, efficient price discovery, reduced communication overhead), this needs to be researched and quantified via an analysis platform that models distribution-level markets at the appropriate fidelity. Specifically, the simultaneous evaluation of market performance, DER performance, DER bidding approaches, and distribution feeder power quality requires modeling that spans multiple technical areas. Co-simulation has emerged as a powerful tool in addressing this type of problem, where outputs depend on a range of underlying areas of expertise and associated models. In this paper we describe a solution, as implemented in the HELICS co-simulation platform, where we include (1) high fidelity house models, (2) intelligent bidding agents, (3) a modular market integration/design, and (4) a distribution feeder model. We then present a case study where we test two different market designs: (1) a pseudo-wholesale double-blind auction, and (2) an asynchronous matching market. In this work, the markets are run under two DER penetration levels and economic results are compared to full retail net energy metering and avoided cost net metering scenarios that bookend current approaches to remuneration of DER participation. We show the potential for transactive markets to provide increased value for most customers relative to net metering (and all customers relative to avoided cost scenarios) while decreasing costs for the utility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of a Microgrid Transition Controller II: System Recovery Under Abnormal Conditions

This paper presents a microgrid transition controller for managing emergency operation when the microgrid experiences a system blackout caused by an internal or external fault. The developed transition controller consists of various application function blocks, including normal operation, emergency operation, and coordination between them. The developed microgrid transition controller is validated by a sample microgrid, and two test cases are investigated: islanded black start and grid-connected black start. The simulation results demonstrate the feasibility and effectiveness of the proposed microgrid transition controller for handling emergency operation and transitioning to normal operation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of a Microgrid Transition Controller II: System Recovery Under Abnormal Conditions: Preprint

This paper presents a microgrid transition controller for managing emergency operation when the microgrid experiences a system blackout caused by an internal or external fault. The developed transition controller consists of various application function blocks, including normal operation, emergency operation, and coordination between them. The developed microgrid transition controller is validated by a sample microgrid, and two test cases are investigated: islanded black start and grid-connected black start. The simulation results demonstrate the feasibility and effectiveness of the proposed microgrid transition controller for handling emergency operation and transitioning to normal operation.

14 SOLAR ENERGY↗

Application of Intelligent Load Control to Manage Building Loads to Support Rapid Growth of Distributed Renewable Generation

Electricity utilities are faced with the mounting challenge of providing a stable supply of power to meet the growing demand while also integrating rapid growth in distributed variable renewable generation. Traditional means of balancing short- and long-term supply and demand imbalance will be expensive. Alternative approaches of using flexible loads in buildings are needed to mitigate the imbalance at a lower cost. This paper shows how the intelligent load control (ILC) process can be used to manage loads in buildings by dynamically prioritizing loads for curtailment using both quantitative and qualitative criteria. The ILC process can be deployed on low-cost computing platforms without the need for any additional sensing. ILC was first validated in a simulation environment to provide two grid service use cases: (1) managing monthly peak electricity demand and (2) managing buildings’ electricity consumption during a capacity bidding event. After being successfully tested in a simulation environment, ILC was deployed on real buildings to manage electricity consumption to provide two different use cases under different outdoor operating conditions. Both the simulation tests and the real building experiments were deployed using VOLTTRON™, a distributed sensing and control platform. The results from the tests and experiments showed that ILC was able to manage the controllable loads (heat pumps) in the building to maintain the electricity consumption at the desired level without a significant impact on occupant comfort. Overall, the results demonstrate that the ILC allows coordination of the controllable loads and provides a more intelligent means of load management than the traditional duty-cycling approach.

Kim, Woohyun↗

V1G Frequency Regulation: Algorithm Development, Validation & Analysis at Scale

Researchers at Argonne National Laboratory developed and validated a high-fidelity digital twin of a smart charging (V1G) ecosystem to model the participation of up to 1,000 unique electric vehicles (EVs) in the PJM frequency regulation market. Utilizing a discrete-event framework, the simulation models complex interactions, from dynamic grid signals (updated every 2 seconds) to individual EV charging dynamics. The simulation incorporates multiple EV models created from real-world lab test data. Researchers tested multiple control algorithms to balance the dual objectives of maximizing aggregator’s revenue and driver charging needs. Results demonstrate that aggregated EVs function as a controllable, highly effective grid resource, achieving high PJM Performance Scores (80–90%). Additionally, an optimized, market-aware bidding strategy was identified as key to profitability. The platform was shown to provide drivers with an average charging discount of nearly 50%. The algorithm was further validated in the lab using production EVs and charging stations to compare simulation results with real-world performance.

Manne, Nithin↗

Application of Artificial Neural Network Model for Optimized Control of Condenser Water Temperature Set-Point in a Chilled Water System

Here, in this study, real-time predictive control and optimization model based on an ANN (artificial neural network) was developed to evaluate the cooling energy saving performance of the optimized control of CndWT (condenser water temperature). For this purpose, the difference in TCEC (total cooling energy consumption) between the conventional control strategy when the CndWT produced by the cooling tower is fixed and the optimized control strategy when real-time control of the CndWT through the optimal ANN model is applied was compared and analyzed. For the modeling of the building to be simulated, the co-simulation of EnergyPlus and MATLAB was built through the middleware Building Controls Virtual Test Bed. For the prediction of TCEC, an ANN model was developed through MATLAB's neural network toolbox. The model accuracy of the ANN was examined through Cv(RMSE) index and as a result, Cv(RMSE) of the optimized ANN model turned out to be approximately 25 %. More importantly, the predictive control technique was able to save TCEC by 5.6 % compared to the conventional control method constantly fixing CndWT set-point to 30 °C. These results showed that the CndWT needs to be dynamically controlled using artificial intelligence technique such as ANN model and that significant energy savings were achievable compared to the conventional fixed control.

42 ENGINEERING↗

Crystal plasticity modeling for the strengthening effect of multilayered copper–graphene nanocomposites

The paper explores plastic deformation mechanisms in metal–graphene nanocomposites, illustrating their material strengthening effects through a crystal plasticity finite element (CPFE) model. This model is compared with published experimental results, which have previously shown that the two-dimensional shape of graphene effectively controls dislocation motion and significantly enhances the strength of metals. Simulated nanopillar compression tests, using a physics-based CP model that incorporates surface nucleation and single-arm source dislocation mechanisms, help us understand dislocation motions at submicron length scales. The crystal plasticity models are applied to nanolayered composites with copper grain layers and monolayer graphene, featuring repeat layer spacings of 200 nm, 125 nm, and 70 nm, respectively. This study quantifies the accumulation of dislocations at the graphene interfaces, contributing to the ultra-high strength of copper–graphene composites. Furthermore, a Hall–Petch-like correlation is established between yield strength and the number of embedded graphene layers.

36 MATERIALS SCIENCE↗