Search NASA⌕ Search

SEARCH · Search NASA

Results for “cooling load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Self-welding of Inconel 617 under high-pressure-high-temperature conditions for nuclear reactors

In response to continuously declining availability of fossil fuels, nuclear power has become an important alternative source of power generation. Growing application of nuclear power has relieved the shortage of electricity. However, it is also accompanied with new drawbacks, such as radioactive waste, and potential catastrophic consequences in case of major accidents. For nuclear power plants, severe accidents mostly originate from the reactor, making the reliability of the reactor of paramount importance to the overall safety of a nuclear power plant. Massive heat generation through nuclear fission/fusion and heat exchange render the whole reactor operating at extremely high temperatures (i.e., 900–1000 °C), which, in conjunction with large load from subsystems/ components made of special heavy alloys, renders the reactor under the risk of self-welding, a phenomenon that could lead to strong bonding between components and paralyze the operability of the nuclear reactor. This paper investigates the self-welding behavior of Inconel 617, a primary candidate nickel alloy for key components of the next generation gas cooled nuclear plant, inside a controlled atmospheric furnace with preset static load, simulating the high-pressure high-temperature conditions inside nuclear reactors. Therefore, test results show that Inconel 617 experiences self-welding through common oxide zone at the interface, and it has remarkable bonding strength, requiring 4114 N (57.15 MPa) and 4338 N (60.25 MPa) to break apart a mated sample pair, under an apparent contact pressure of 0.341 MPa after 50-h aging, in helium and air atmospheres, respectively. The higher oxygen presence in air results in slightly stronger oxide bond at the interface, compared to helium, and the bond strength increases with dwell time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessing and Reducing Plug and Process Loads in Retail Buildings

Plug and process loads (PPLs) account for 33% of U.S. commercial building electricity consumption (McKenney et al. 2010). (See Figure 1.) Minimizing these loads is a significant challenge in the design and operation of an energy-efficient building. Lobato et al. (2011) and Lobato et al. (2012) define PPLs as energy loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and that typically do not provide comfort to the occupants. The percentage of total building energy use from PPLs is increasing. According to the U.S. Department of Energy (DOE), by 2030, commercial building energy consumption is expected to increase by 24%; PPL energy consumption is anticipated to increase by 49% in the same time frame (DOE 2010). These trends illustrate the importance of PPL energy reduction to achieve an overall goal of reducing whole-building energy consumption.

30 DIRECT ENERGY CONVERSION↗

Assessing and Reducing Plug and Process Loads in Office Buildings

Plug and process loads (PPLs) account for 33% of U.S. commercial building electricity consumption (McKenney et al. 2010). (See Figure 1.) Minimizing these loads is a significant challenge in the design and operation of an energy-efficient building. Lobato et al. (2011) and Lobato et al. (2012) define PPLs as energy loads that are not related to general lighting, heating, ventilation, cooling, and water heating, and that typically do not provide comfort to the occupants. The percentage of total building energy use from PPLs is increasing. According to the U.S. Department of Energy (DOE), by 2030, commercial building energy consumption is expected to increase by 24%; PPL energy consumption is anticipated to increase by 49% in the same time frame (DOE 2010). These trends illustrate the importance of PPL energy reduction to achieve an overall goal of reducing whole-building energy consumption.

30 DIRECT ENERGY CONVERSION↗

Multi-stage load partitioning in additively manufactured Al6061+TiC nanocomposite characterized by in-situ neutron diffraction

Metal matrix composites (MMCs), combining metal matrix and ceramic particles, exhibit high mechanical strength and stiffness compared to conventional metallic materials. During fusion-based additive manufacturing (AM), MMCs undergo a rapid heating and cooling thermal history, which affects the interfacial bonding, thermal misfit stress and mechanical load transfer behavior between the metal matrix and particles, thus impacting the bulk mechanical performance. Here, we investigate the deformation dynamics and phase-specific load transfer in fusion-based AMed Al6061 +TiC MMCs through in-situ neutron diffraction. By calculating the phase-specific lattice strains, a multi-stage load transfer and deformation behavior during uniaxial compression is revealed: (1) elastic deformation in Stage I for both phases; (2) sudden stress rebalance between two phases in Stage II, evidenced by a sudden decrease in Al lattice strain and increase in TiC; (3) active load carrying by both phases in Stage III, with both phases experiencing an increase in lattice strains. Further, the deformation mechanism of each stage is deducted by correlating the evolutions of the interphase stresses and peaks’ broadening and intensity of the Al matrix. The local plastic deformation of the Al matrix near the phase interface is triggered and leads to stress rebalancing in Stage II. The global plastic deformation subsequently propagates throughout the Al matrix in Stage III, and the composite is further hardened through both dislocation multiplication and load transfer. The findings offer valuable insights into deformation and load-sharing behavior in AMed MMCs.

36 MATERIALS SCIENCE↗

DEVAP-EDDR-TES (Simulation framework for a desiccant assisted air conditioning system with heat pump regeneration and energy storage) [SWR-24-66]

This software is a simulation framework that models a load flexible air conditioner system. The system consists of an evaporatively cooled liquid desiccant air conditioner (eLD-AC) subsystem, an electrically driven desiccant regenerator (EDDR) subsystem, and a stratified liquid desiccant storage (SLDS) subsystem. The software can be used to 1) predict the steady-state performance of the system given user-specified convergence criteria; 2) predict the dynamic performance of the entire system over a typical drive cycle operation subjected to user-specified building thermal loads and desired electrical load profile; 3) evaluate the synergy of all three subsystems operating altogether and improve the energy storage control strategy.

Huang, Ransisi↗

CGOLS V: Disk-wide Stellar Feedback and Observational Implications of the Cholla Galactic Wind Model

Abstract We present the fifth simulation in the Cholla Galactic OutfLow Simulation (CGOLS) project—a set of isolated starburst galaxy simulations modeled over large scales (10 kpc) at uniformly high resolution (Δx≈ 5 pc). Supernova feedback in this simulation is implemented as a disk-wide distribution of clusters, and we assess the impact of this geometry on several features of the resulting outflow, including the radial profiles of various phases; mass, momentum, and energy outflow rates; covering fraction of cool gas; mock absorption-line spectra; and X-ray surface brightness. In general, we find that the outflow generated by this model is cooler, slower, and contains more mass in the cool phase than a more centrally concentrated outflow driven by a similar number of supernovae. In addition, the energy loading factors in the hot phase are an order of magnitude lower, indicating much larger losses due to radiative cooling in the outflow. However, coupling between the hot and cool phases is more efficient than in the nuclear burst case, with almost 50% of the total outflowing energy flux carried by the cool phase at a radial distance of 5 kpc. These physical differences have corresponding signatures in observable quantities: the covering fraction of cool gas is much larger, and there is greater evidence of absorption in low and intermediate ionization energy lines. Taken together, our simulations indicate that centrally concentrated starbursts are more effective at driving hot, low-density outflows that will expand far into the halo, while galaxy-wide bursts may be more effective at removing cool gas from the disk.

Astronomy & Astrophysics↗

Efficient Refrigerated Display Cases - Can They Flex Their Power? Preprint

Refrigerated display cases are widely-used, critical equipment in supermarkets for maintaining product safety and quality. Energy-efficient medium temperature liquid-cooled refrigerated display cases can save 25-70% of the total supermarket energy, according to manufacturers. Traditionally, cases operate by maintaining a temperature around a user-input setpoint that is dependent on the product in the case. Although cases are major electrical energy consumers, they are hardly ever considered for implementing load-flexibility strategies. With added load-flexibility capabilities, refrigerated display cases can shed (reduce), or shift (by adding and subsequently shedding) load. Supermarkets can reduce their energy costs and enhance electric grid integrity by implementing these smart load-flexibility control strategies. Advanced controls can also enable load-shifting to coincide with optimum periods of renewable energy generation. This will further improve operational costs and reduce greenhouse gas emissions without compromising food safety and quality. In this research, we have evaluated the energy savings of liquid-cooled medium temperature display cases and developed load flexibility strategies leveraging an advanced controls system, a variable speed compressor, and heat rejection via a water-cooled condenser. This study further assessed the impact of load flexibility strategies in a controlled environment chamber for a single refrigerated display case.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Extreme Water Uptake of Hygroscopic Hydrogels through Maximized Swelling‐Induced Salt Loading

Abstract Hygroscopic hydrogels are emerging as scalable and low‐cost sorbents for atmospheric water harvesting, dehumidification, passive cooling, and thermal energy storage. However, devices using these materials still exhibit insufficient performance, partly due to the limited water vapor uptake of the hydrogels. Here, the swelling dynamics of hydrogels in aqueous lithiumchloride solutions, the implications on hydrogel salt loading, and the resulting vapor uptake of the synthesized hydrogel–salt composites are characterized. By tuning the salt concentration of the swelling solutions and the cross‐linking properties of the gels, hygroscopic hydrogels with extremely high salt loadings are synthesized, which enable unprecedented water uptakes of 1.79 and 3.86 gg −1 at relative humidity (RH) of 30% and 70%, respectively. At 30% RH, this exceeds previously reported water uptakes of metal–organic frameworks by over 100% and of hydrogels by 15%, bringing the uptake within 93% of the fundamental limit of hygroscopic salts while avoiding leakage problems common in salt solutions. By modeling the salt‐vapor equilibria, the maximum leakage‐free RH is elucidated as a function of hydrogel uptake and swelling ratio. These insights guide the design of hydrogels with exceptional hygroscopicity that enable sorption‐based devices to tackle water scarcity and the global energy crisis.

Graeber, Gustav↗

COGIHTO: Comprehensive Geothermal Integrated HVAC Retrofits in Disadvantaged Communities

Geothermal heating and cooling (GHC) systems offer one of the most efficient approaches to provide space conditioning and water heating in buildings. Due to the relatively stable temperature of the ground year-round, these systems can provide an efficient solution to decarbonize heating systems. Yet this technology has faced limited market adoption due to its high first cost. This project seeks to address this barrier by designing a community GHC system at a public housing development in New York, taking advantage of load diversity (in terms of the timing and amount of heating / cooling used per person) that a larger community offers to reduce the size and thus first cost of a GHC system. Project success would result in societal benefit from reduced energy and fossil fuel use, reduced local emissions, and improved comfort, which would positively impact the health and well-being this community. This report presents the findings from Phase 1 project supported by the Department of Energy’s Geothermal Technologies Office and includes the technical design of a GHC at a public housing development in New York. To support the success of a potential deployment of a GHC system, the team conducted community engagement and prepared an assessment of the local workforce needs. The project team, led by EPRI, considered a subset of NYCHA housing developments that were previously identified by NYCHA as suitable for GHC retrofits. This report presents the site selection criteria the team developed and the overall score assigned to each of the eight developments considered. One site was selected for focus of the technical design: Stapleton Houses in Staten Island, a mid-size development with roughly 700 apartments across 6 buildings. The site has an existing hot water hydronic loop served by natural gas boilers for space heating and water heating. The technical design partner assessed baseline energy consumption at the site and established thermal models of the apartment buildings to assist in the design. The team considered several GHC system configurations and selected a hybrid geothermal design fed from water-source heat pumps with auxiliary gas boilers in a central plant. This design best leveraged the existing site configuration and minimized costs due to additional electrical infrastructure upgrades. The report also details the feedback received from community engagement efforts and the findings from the workforce needs assessment and workforce transition plan. Members of the site maintenance staff and the resident advisory council were interviewed for their input and feedback about both the site’s existing heating/cooling infrastructure and how a construction project would impact resident life. This feedback was taken into consideration when completing the geothermal system design. Research was conducted into existing workforce development opportunities available to NYCHA residents. A workforce development plan was established using information from NYCHA’s resident economic empowerment and sustainability group, along with training material and curriculum from the International Ground Source Heat Pump Association (IGSHPA).

15 GEOTHERMAL ENERGY↗

Sliding friction and wear behavior of nuclear graphite in high temperature inert environment: Influence of contact load, speed and temperature

Repeated dynamic interactions of graphitic components in pebble-bed gas-cooled nuclear reactors can cause abrasive wear-induced pebble surface damage, generate hazardous fine graphite debris, and alter fuel circulation dynamics due to changes in friction behavior. Comprehensive tribological characterization of nuclear graphitic materials in conditions relevant to reactor operation is needed to assess reactor long-term safety and performance. This work reports sliding friction and wear behavior of self-mated nuclear graphite ET-10 at various elevated temperatures (650 °C and 750 °C), sliding speeds (1 and 10 mm/s) and contact loads (20 and 40 N) in a controlled argon environment. The results revealed nonmonotonic frictional behavior with a higher running-in coefficient of friction (COF) followed by a lower steady-state COF, as a result of transition from two-body abrasion to three-body abrasion along with formation of a tribofilm. A key finding of this work is the sensitivity of the running-in COF to experimental conditions; maximum running-in values were lower at either elevated temperature (0.52–0.54) or reduced sliding speed (0.51–0.54). Conversely, the steady-state COF remained invariant at approximately 0.3 across all tested parameters. Transmission electron microscopy revealed a 0.5–2.0 μm thick nanocrystalline tribofilm that was thought to be formed by the compaction of the graphitic wear debris on the contact surface during the sliding process. The nanocrystalline nature of the tribofilm was further confirmed by Raman spectroscopy. As a result, the combination of tribological testing and morphological characterization provided a mechanistic understanding of the frictional behavior of nuclear graphite upon sliding.

Friction↗

COMPASS-U Global Heat Balance Calculations

COMPASS-U is a medium size, high magnetic field experimental tokamak (R = 0.9 m, B t = 5 T, and I p = 2 MA), built at the Institute of Plasma Physics, Czech Academy of Sciences (IPP-CAS). This global heat balance calculation for COMPASS-U was done at Princeton Plasma Physics Laboratory (PPPL). Based on our previous experience of building global thermal model for National Spherical Torus Experiment-Upgrade (NSTX-U) at PPPL, this 2-D global thermal model geometry represents a typical cross section of COMPASS-U machine. The model includes thermal radiation, conduction, and convection among components and also between the machine and outer environment. Helium gas heating/cooling was modeled with fluid element and surface element. This model was used to calculate component temperatures and heat distribution during heat up, cryogenic cool down, normal operation, and fault operation scenarios. Definition of 14 main thermal scenarios was provided by IPP-CAS. First nine are normal operation scenarios. Scenarios #10–#14 are fault scenarios. Results of thermal scenario #5 will be given and discussed in this article, including peak temperatures, temperature ratcheting, energy distribution, and required cooling power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Identifying Molecular Scale Interactions of Nucleating Agents with Salt Hydrates for Thermal Energy Storage Applications

Latent heat based thermal energy storage is of interest as a method to mitigate and time-shift thermal load peaks and hence reduce energy demands for heating and cooling buildings. Notably, Glauber’s salt (GS) presents a good choice as a phase change material (PCM) for building applications because it has a melting point near room temperature (i.e., 32.4 °C), a large heat of fusion and energy density, and is low cost (~ $100/ton). However, there are several known limitations to using GS as a PCM, such as incongruent melting, high degree of supercooling, and formation of other hydration states, which renders GS unsuitable for practical use. Inorganic crystals acting as nucleating agents can avoid some of these issues with GS [1]. Understanding nucleation behavior through typical calorimetry experiments offers limited insight into the molecular-scale mechanisms. Here, we report isothermal titration calorimetry [2] to investigate the interactions between sodium sulfate salt and an organic nucleating agent - glycine. Our experiments provide qualitative and quantitative understanding of how glycine interacts with sodium sulfate across various temperatures. The findings offer insights into the nucleation onset temperature (24°C) and underscore the pivotal role of glycine's zwitterionic structure in facilitating nucleation. This preliminary work provides a foundation for subsequent exploration of nucleating agents that would be incorporated in different salt hydrate systems. 1. Purohit, B. K., and V. S. Sistla. "Inorganic salt hydrate for thermal energy storage application: A review." Energy Storage 3, no. 2 (2021): e212. 2. Velázquez-Campoy, Adrián, Hiroyasu Ohtaka, Azin Nezami, Salman Muzammil, and Ernesto Freire. "Isothermal titration calorimetry." Current protocols in cell biology 23, no. 1 (2004): 17-8.

calorimetry, nucleation & growth↗

Advanced Data Center Energy Opportunities: Cloud and Infrastructure CoP - Data Center Energy and Efficiency with AI Adoption

The NLR portion of the "Cloud & Infrastructure CoP - Data Center Energy and Efficiency with AI Adoption" web meeting will cover data center locations, energy use and load growth, best practices, performance metrics, transition to direct liquid cooled data center equipment, and NLR's approach to optimizing data center.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Coupled heat and mass transfer in internally cooled silica gel-coated aluminum foam heat exchangers for dehumidification

Solid desiccant dehumidifiers offer significant potential to improve humidity control in buildings due to their ability to independently regulate latent (humidity) and sensible (temperature) loads. However, adsorption of water vapor by desiccants is an exothermic process; the resulting heat of adsorption increases both the desiccant bed temperature and the temperature of the air flowing over the bed, thereby limiting the performance of desiccant dehumidifiers. To address this problem, desiccant-coated heat exchanger prototypes were developed by coating silica gel onto aluminum foam substrates and integrated with chilled water circulation for effective removal of the heat of adsorption. Prototype heat exchangers with two different pore densities (10 and 20 pores per inch (PPI)) and two different desiccant loadings (∼10.36% and ∼17.80%) were fabricated. Experiments were conducted by varying the inlet air face velocity, chilled water inlet temperature, and chilled water flow rate to investigate the coupled heat and mass transfer characteristics of the prototype heat exchangers over a wide range of operating conditions. The underlying transport mechanisms were analyzed using transient desiccant bed temperature, outlet air temperature, and outlet humidity profiles. The results demonstrate that internal cooling significantly enhances dehumidification performance by maintaining more favorable thermodynamic conditions for water vapor adsorption. Under identical operating conditions, a 20 PPI heat exchanger coated with 25.05 g of silica gel achieved 98.98% higher cumulative water uptake and 97.75% higher moisture removal capacity than the corresponding non-cooled case after 5 min of adsorption. This substantial enhancement was further supported by a validated one-dimensional coupled heat and mass transfer model developed in the present study. To date, this is one of the first experimental studies to systematically investigate the combined effects of internal cooling, foam pore density, and desiccant loading on the performance of silica-gel-coated metal foam heat exchangers under HVAC-relevant operating conditions.

42 ENGINEERING↗

Cryogenic aspects of a 20 MW class low-temperature superconducting generator for the renewables industry

In this paper we give a progress update on the cryogenic design for cooling a 20 MW class, partially superconducting generator with stationary field coils for offshore wind renewables industry [1-2]. This is a continuation of an earlier program on a 10 MW system dating back ten years. Whereas this new power rating increase leads to a radial diameter expansion of the superconducting field coils from 4 to > 9.5 m, it maintains the axial length. We show the design based on this scaled up with enlarged diameter. The field coil size increase asks for higher cooling power that leads to a bigger cold box size to accommodate the cryocoolers. In the design, as many as 8 cryocoolers can be accessed and serviced from the nacelle that houses the main cryogenic components. A typical thermal load balance sheet with all components is given and compared against the available cryocooler cooling power at different operating conditions. Due to the cryocoolers’ local point of contact cooling within the nacelle, the temperature gradient of the thermal shield that fully encloses the cold mass with its embedded field coils needs to be balanced out to minimize the heat burden on the field coils. This requires additional analytical efforts and implementation of further design features. The extended nacelle houses the cold box with its cryogenic infrastructure. The interface for the envisaged cryogenic pushbutton closed-loop circulating system remains invisible, requires no handling of cryogenic liquids and is hermetically closed. The field coil diameter increase also leads to a greater initial helium gas storage volume. In addition, it requires higher initial room temperature fill pressure within the toroidal helium vapor storage tanks and in cooling tubes connecting to the cryocoolers. The toroidal helium gas tanks are thermally coupled with the thermal shield so that helium convection inside the storage tank can improve heat transfer and reduce the temperature gradient of the thermal shield. Besides those heat transfer challenges, additional mechanical strain within this large structure is exerted on the torque tubes during initial cooldown and when energizing field coils. Some of those design challenges are quite unexpected, leading to novel workarounds in order to maintain the chosen cooling strategy. Finally, we assess those design limitations in view of further cryogenic scalability with emphasis on manufacturability and assembly.

cryogenics↗

Load Shifting with Space Conditioning Heat Pumps During Heating Season in the Pacific Northwest

Ductless mini- and multi-split heat pumps are commonly deployed in Pacific Northwest residences, which historically have inefficient space heating and no space cooling. Heat pumps provide these residences with more energy-efficient space heating in the winter and space cooling for increasingly warm summer periods. For many of these applications, heat pumps add a new electrical load at the residence, compelling regional utilities to seek to understand their impacts on the electrical grid and opportunities for load management. In coordination with regional utilities, this study examined the winter load-shifting potential of residential multi-split heat pumps with variable capacity technology. The study included nine residential sites with a total of 20 ductless indoor units, which underwent simulated smart grid control. Grid control functionality was provided through the CTA-2045 communication protocol and included offsetting temperature setpoints for individual indoor units in the study. Field data collection included whole-house and heating, ventilation, and air conditioning electrical power consumption; indoor zone temperatures; occupant surveys; and CTA-2045 curtailment data for both baseline and simulated load-shifting events by site. This paper provides an overview of the load-shifting strategies and aggregated results from winter data collection.

ASHRAE, Heat pump, energy effciency, residential b↗

Power Grid Simulation Testbed for Transactive Energy Management Systems

To effectively engage demand-side and distributed energy resources (DERs) for dynamically maintaining the electric power balance, the challenges of controlling and coordinating building equipment and DERs on a large scale must be overcome. Although several control techniques have been proposed in the literature, a significant obstacle to applying these techniques in practice is having access to an effective testing platform. Performing tests at scale using real equipment is impractical, so simulation offers the only viable route to developmental testing at scales of practical interest. Existing power-grid testbeds are unable to model individual residential end-use devices for developing detailed control formulations for responsive loads and DERs. Furthermore, they cannot simulate the control and communications at subminute timescales. To address these issues, this paper presents a novel power-grid simulation testbed for transactive energy management systems. Detailed models of primary home appliances (e.g., heating and cooling systems, water heaters, photovoltaic panels, energy storage systems) are provided to simulate realistic load behaviors in response to environmental parameters and control commands. The proposed testbed incorporates software as it will be deployed, and enables deployable software to interact with various building equipment models for end-to-end performance evaluation at scale.

24 POWER TRANSMISSION AND DISTRIBUTION↗