Search NASA⌕ Search

SEARCH · Search NASA

Results for “crack detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Insulation Resistance and Leakage Currents in Low-Voltage Ceramic Capacitors with Cracks

Measurement of insulation resistance (IR) in multilayer ceramic capacitors (MLCCs) is considered a screening technique that ensures the dielectric is defect-free. This work analyzes the effectiveness of this technique for revealing cracks in ceramic capacitors. It is shown that absorption currents prevail over the intrinsic leakage currents during standard IR measurements at room temperature. Absorption currents, and consequently IR, have a weak temperature dependence, increase linearly with voltage (before saturation), and are not sensitive to the presence of mechanical defects. In contrary, intrinsic leakage currents increase super-linearly with voltage and exponentially with temperature (activation energy is in the range from 0.6 eV to 1.1 eV). Leakage currents associated with the presence of cracks have a weaker dependence on temperature and voltage compared to the intrinsic leakage currents. For this reason, intrinsic leakage currents prevail at high temperatures and voltages, thus masking the presence of defects.

dielectric polarization↗

Insulation Resistance and Leakage Currents in Low-Voltage Ceramic Capacitors with Cracks

Measurement of insulation resistance (IR) in multilayer ceramic capacitors (MLCCs) is considered a screening technique that ensures the dielectric is defect-free. This work analyzes the effectiveness of this technique for revealing cracks in ceramic capacitors. It is shown that absorption currents prevail over the intrinsic leakage currents during standard IR measurements at room temperature. Absorption currents, and consequently IR, have a weak temperature dependence, increase linearly with voltage (before saturation), and are not sensitive to the presence of mechanical defects. In contrary, intrinsic leakage currents increase super-linearly with voltage and exponentially with temperature (activation energy is in the range from 0.6 eV to 1.1 eV). Leakage currents associated with the presence of cracks have a weaker dependence on temperature and voltage compared to the intrinsic leakage currents. For this reason, intrinsic leakage currents prevail at high temperatures and voltages, thus masking the presence of defects.

testing↗

TPSAS-NF1676L-13664-DND

The safety of aerospace vehicles is largely dependent on the ability of modern non-destructive evaluation (NDE) tools to accurately detect structural damage before a critical flaw size is reached. However, existing NDE technologies are inherently limited by the physical response of the materials being inspected making the detection of small cracks or pre-crack damage difficult. One innovative solution to this problem is to create a multifunctional metallic material that can be used in structural applications and contains second phase sensory particles that significantly enhance the ability of conventional NDE techniques to detect incipient damage during use and at regularly scheduled inspections. Ferromagnetic shape-memory alloys (FSMAs) are an ideal material for use as this second phase material as they undergo a uniform and repeatable change in both magnetic properties and crystallographic structure when strained. These changes are more readily detected than small cracks, thereby, allowing for enhanced detection of damage by conventional NDE techniques. In this study, a multifunctional metallic material was produced by embedding the sensory material particles within an aluminum alloy to form a sensory alloy. The NDE response of the FSMA and the sensory alloy during tension/compression and fatigue loading have been investigated. These results suggest that sensory alloys can be utilized for improved on-board structural health monitoring and to improve the accuracy and reduce time for ground-based inspection.

T. A. Wallace↗

Acoustic determination of cracks in welded joints

The acoustic analysis method permits detection of any cracks that might take place and their manner of propagation. The study deals with the cracks produced in experiments to determine the welding technology for a welded gray cast iron workpiece by using piezoelectric transducers to determine vibration acceleration.

Baltanoiu, M.↗

Flux-focusing eddy current probe and rotating probe method for flaw detection

A flux-focusing electromagnetic sensor which uses a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks about circular fasteners and other circular inhomogeneities in high conductivity material. The unique feature of the device is the ferrous shield isolating a high-turn pick-up coil from an excitation coil. The use of the magnetic shield is shown to produce a null voltage output across the receiving coil in the presence of an unflawed sample. A redistribution of the current flow in the sample caused by the presence of flaws, however, eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. By rotating the probe in a path around a circular fastener such as a rivet while maintaining a constant distance between the probe and the center of a rivet, the signal due to current flow about the rivet can be held constant. Any further changes in the current distribution, such as due to a fatigue crack at the rivet joint, can be detected as an increase in the output voltage above that due to the flow about the rivet head.

Wincheski, Buzz A.↗

Rotating flux-focusing eddy current probe for flaw detection

A flux-focusing electromagnetic sensor which uses a ferromagnetic flux-focusing lens simplifies inspections and increases detectability of fatigue cracks about circular fasteners and other circular inhomogeneities in high conductivity material. The unique feature of the device is the ferrous shield isolating a high-turn pick-up coil from an excitation coil, The use of the magnetic shield is shown to produce a null voltage output across the receiving coil in the presence of an unflawed sample. A redistribution of the current flow in the sample caused by the presence of flaws, however, eliminates the shielding condition and a large output voltage is produced, yielding a clear unambiguous flaw signal. By rotating the probe in a path around a circular fastener such as a rivet while maintaining a constant distance between the probe and the center of a rivet, the signal due to current flow about the rivet can be held constant. Any further changes in the current distribution, such as due to a fatigue crack at the rivet joint, can be detected as an increase in the output voltage above that due to the flow about the rivet head.

Wincheski, Russell A.↗

Optimizing Probability of Detection Point Estimate Demonstration

Probability of detection (POD) analysis is used in assessing reliably detectable flaw size in nondestructive evaluation (NDE). MIL-HDBK-18231and associated mh18232POD software gives most common methods of POD analysis. Real flaws such as cracks and crack-like flaws are desired to be detected using these NDE methods. A reliably detectable crack size is required for safe life analysis of fracture critical parts. The paper provides discussion on optimizing probability of detection (POD) demonstration experiments using Point Estimate Method. POD Point estimate method is used by NASA for qualifying special NDE procedures. The point estimate method uses binomial distribution for probability density. Normally, a set of 29 flaws of same size within some tolerance are used in the demonstration. The optimization is performed to provide acceptable value for probability of passing demonstration (PPD) and achieving acceptable value for probability of false (POF) calls while keeping the flaw sizes in the set as small as possible.

Koshti, Ajay M.↗

Rotordynamic Analysis and Feasibility Study of a Disk Spin Test Facility for Rotor Health Monitoring

Recently, National Aeronautics and Space Administration (NASA) initiated a program to achieve the significant improvement in aviation safety. One of the technical challenges is the design and development of accelerated experiments that mimic critical damage cases encountered in engine components. The Nondestructive Evaluation (NDE) Group at the NASA Glenn Research Center (GRC) is currently addressing the goal concerning propulsion health management and the development of propulsion system specific technologies intended to detect potential failures prior to catastrophe. For this goal the unique disk spin simulation system was assembled at NASA GRC, which allows testing of rotors with the spinning speeds up to 10K RPM, and at the elevated temperature environment reaching 540 C (1000 F). It is anticipated that the facility can be employed for detection of Low Cycle Fatigue disk cracking and further High Cycle Fatigue blade vibration. The controlled crack growth studies at room and elevated temperatures can be conducted on the turbine wheels, and various NDE techniques can be integrated and assessed as in-situ damage monitoring tools. Critical rotating parts in advanced gas turbine engines such as turbine disks frequently operate at high temperature and stress for long periods of time. The integrity of these parts must be proven by non-destructive evaluation (NDE) during various machining steps ranging from forging blank to finished shape, and also during the systematic overhaul inspections. Conventional NDE methods, however, have unacceptable limits. Some of these techniques are time-consuming and inconvenient for service aircraft testing. Almost all of these techniques require that the vicinity of the damage is known in advance. These experimental techniques can provide only local information and no indication of the structural strength at a component and/or system level. The shortcomings of currently available NDE methods lead to the requirement of new damage detection techniques that can provide global information on the rotating components/system, and, in addition, they do not require direct human access to the operating system. During this period of research considerable effort was directed towards the further development of experimental facility and development of the vibration-based crack detection methodology for rotating disks and shafts. A collection of papers and reports were written to describe the results of this work. The attached captures that effort and represents the research output during the grant period.

Sawicki, Jerzy T.↗

Detection and Location of Transverse Matrix Cracks in Cross-Ply Gr/Ep Composites Using Acoustic Emission

Transverse matrix cracking in cross-ply gr/ep laminates was studied with advanced acoustic emission (AE) techniques. The primary goal of this research was to measure the load required to initiate the first transverse matrix crack in cross-ply laminates of different thicknesses. Other methods had been previously used for these measurements including penetrant enhanced radiography, optical microscopy, and audible acoustic microphone measurements. The former methods required that the mechanical test be paused for measurements at load intervals. This slowed the test procedure and did not provide the required resolution in load. With acoustic microphones, acoustic signals from cracks could not be clearly differentiated from other noise sources such as grip damage, specimen slippage, or test machine noise. A second goal for this work was to use the high resolution source location accuracy of the advanced acoustic emission techniques to determine whether the crack initiation site was at the specimen edge or in the interior of the specimen.In this research, advanced AE techniques using broad band sensors, high capture rate digital waveform acquisition, and plate wave propagation based analysis were applied to cross-ply composite coupons with different numbers of 0 and 90 degree plies. Noise signals, believed to be caused by grip damage or specimen slipping, were eliminated based on their plate wave characteristics. Such signals were always located outside the sensor gage length in the gripped region of the specimen. Cracks were confirmed post-test by microscopic analysis of a polished specimen edge, backscatter ultrasonic scans, and in limited cases, by penetrant enhanced radiography. For specimens with three or more 90 degree plies together, there was an exact 1-1 correlation between AE crack signals and observed cracks. The ultrasonic scans and some destructive sectioning analysis showed that the cracks extended across the full width of the specimen. Furthermore, the locations of the cracks from the AE data were in excellent agreement with the locations measured with the microscope. The high resolution source location capability of this technique, combined with an array of sensors, was able to determine that the cracks initiated at the specimen edges, rather than in the interior. For specimens with only one or two 90 degree plies, the crack-like signals were significantly smaller in amplitude and there was not a 1-1 correlation to observed cracks. This was similar to previous results. In this case, however, ultrasonic and destructive sectioning analysis revealed that the cracks did not extend across the specimen. They initiated at the edge, but did not propagate any appreciable distance into the specimen. This explains the much smaller AE signal amplitudes and the difficulty in correlating these signals to actual cracks in this, as well as in the previous study.

Prosser, W. H.↗

High-temperature all-fiber non-destructive multi-parameter sensing system with consistent performance

A high-temperature all-fiber non-destructive multi-parameter sensing system is developed. The system can operate consistently in a wide range of temperature changes by specially designed active signal generation and detection units. It is capable of monitoring temperature up to 600°C and cracks on metal pipes with an acoustic wave generation unit and an acoustic detection unit. A gold-coated multi-mode fiber is used to deliver a laser pulse for acoustic excitation while minimizing parasitic acoustic signals at high temperature. An in-fiber Fabry–Perot fiber Bragg grating (FP-FBG) is fabricated in another single-mode fiber and bonded to the test object for acoustic detection. The FP-FBG avoids strain redistribution inside the bonder at high temperature to ensure consistent operation. The feasibility of the system for temperature monitoring and crack detection in real-world applications is also demonstrated on an industry-standard P91 pipe.

He, Jiaji (ORCID:0000000165661887)↗

Experimental flaw detection by scattering of plate waves

The surface displacements of elastic waves scattered from a surface-breaking crack are measured with a capacitive transducer on a 2D plate, and comparisons with theoretical predictions are reported. The noncontacting detector has a wide and flat frequency response which measures the response of a glass plate to the propagation of Rayleigh-Lamb waves. A theoretical simulation of the surface displacements is generated by multiplying experimental traces with a cosine window, and Green's function is used to compute the source function. Power spectra are also recorded from the experiment to compare the results with a finite-element model of the crack, and good agreement is reported for results in both the time and frequency domains. The crack can be detected in the far field when the spacing of the receiver locations is small, and the transducer/probe appears to be a practical flaw-detection instrument.

Spetzler, Hartmut↗

Crack Imaging and Quantification in Aluminum Plates with Guided Wave Wavenumber Analysis Methods

Guided wavefield analysis methods for detection and quantification of crack damage in an aluminum plate are presented in this paper. New wavenumber components created by abrupt wave changes at the structural discontinuity are identified in the frequency-wavenumber spectra. It is shown that the new wavenumbers can be used to detect and characterize the crack dimensions. Two imaging based approaches, filter reconstructed imaging and spatial wavenumber imaging, are used to demonstrate how the cracks can be evaluated with wavenumber analysis. The filter reconstructed imaging is shown to be a rapid method to map the plate and any existing damage, but with less precision in estimating crack dimensions; while the spatial wavenumber imaging provides an intensity image of spatial wavenumber values with enhanced resolution of crack dimensions. These techniques are applied to simulated wavefield data, and the simulation based studies show that spatial wavenumber imaging method is able to distinguish cracks of different severities. Laboratory experimental validation is performed for a single crack case to confirm the methods' capabilities for imaging cracks in plates.

Yu, Lingyu↗

Some Observations on Damage Tolerance Analyses in Pressure Vessels

AIAA standards S080 and S081 are applicable for certification of metallic pressure vessels (PV) and composite overwrap pressure vessels (COPV), respectively. These standards require damage tolerance analyses with a minimum reliable detectible flaw/crack and demonstration of safe life four times the service life with these cracks at the worst-case location in the PVs and oriented perpendicular to the maximum principal tensile stress. The standards require consideration of semi-elliptical surface cracks in the range of aspect ratios (crack depth a to half of the surface length c, i.e., (a/c) of 0.2 to 1). NASA-STD-5009 provides the minimum reliably detectible standard crack sizes (90/95 probability of detection (POD) for several non-destructive evaluation (NDE) methods (eddy current (ET), penetrant (PT), radiography (RT) and ultrasonic (UT)) for the two limits of the aspect ratio range required by the AIAA standards. This paper tries to answer the questions: can the safe life analysis consider only the life for the crack sizes at the two required limits, or endpoints, of the (a/c) range for the NDE method used or does the analysis need to consider values within that range? What would be an appropriate method to interpolate 90/95 POD crack sizes at intermediate (a/c) values? Several procedures to develop combinations of a and c within the specified range are explored. A simple linear relationship between a and c is chosen to compare the effects of seven different approaches to determine combinations of aj and cj that are between the (a/c) endpoints. Two of the seven are selected for evaluation: Approach I, the simple linear relationship, and a more conservative option, Approach III. For each of these two Approaches, the lives are computed for initial semi-elliptic crack configurations in a plate subjected to remote tensile fatigue loading with an R-ratio of 0.1, for an assumed material evaluated using NASGRO (registered 4) version 8.1. These calculations demonstrate that for this loading, using Approach I and the initial detectable crack sizes at the (a/c) endpoints in 5009 specified for the ET and UT NDE methods, the smallest life is not at the two required limits of the (a/c) range, but rather is at an intermediate configuration in the range (a/c) of 0.4 to 0.6. Similar analyses using both Approach I and III with the initial detectable crack size at the (a/c) endpoints in 5009 for PT NDE showed the smallest life may be at an (a/c) endpoint or an intermediate (a/c), depending upon which Approach is used. As such, analyses that interrogate only the two (a/c) values of 0.2 and 1 may result in unconservative life predictions. The standard practice may need to be revised based on these results.

Raju, Ivatury S.↗

Toward Autonomous Field Inspection of CSP Collectors With a Polarimetric Imaging Drone

We developed a polarimetric imaging drone to perform field inspections of heliostats and carried out field tests at Sandia’s National Solar Thermal Test Facility (NSTTF). The preliminary results show that Degree of Linear Polarization (DOLP) and Angle of Polarization (AOP) images greatly enhanced the edge detection results compared with the conventional visible images, supporting fast and accurate detection of heliostat mirror edges and cracks. The system holds the promise to enable future automated detection of heliostats optical errors and mirror defects.

14 SOLAR ENERGY↗

Probabilistic Estimation of Critical Flaw Sizes in the Primary Structure Welds of the Ares I-X Launch Vehicle

The primary structure of the Ares I-X Upper Stage Simulator (USS) launch vehicle is constructed of welded mild steel plates. There is some concern over the possibility of structural failure due to welding flaws. It was considered critical to quantify the impact of uncertainties in residual stress, material porosity, applied loads, and material and crack growth properties on the reliability of the welds during its pre-flight and flight. A criterion--an existing maximum size crack at the weld toe must be smaller than the maximum allowable flaw size--was established to estimate the reliability of the welds. A spectrum of maximum allowable flaw sizes was developed for different possible combinations of all of the above listed variables by performing probabilistic crack growth analyses using the ANSYS finite element analysis code in conjunction with the NASGRO crack growth code. Two alternative methods were used to account for residual stresses: (1) The mean residual stress was assumed to be 41 ksi and a limit was set on the net section flow stress during crack propagation. The critical flaw size was determined by parametrically increasing the initial flaw size and detecting if this limit was exceeded during four complete flight cycles, and (2) The mean residual stress was assumed to be 49.6 ksi (the parent material s yield strength) and the net section flow stress limit was ignored. The critical flaw size was determined by parametrically increasing the initial flaw size and detecting if catastrophic crack growth occurred during four complete flight cycles. Both surface-crack models and through-crack models were utilized to characterize cracks in the weld toe.

Pai, Shantaram S.↗

Validation Test Results for Orthogonal Probe Eddy Current Thruster Inspection System

Recent nondestructive evaluation efforts within NASA have focused on an inspection system for the detection of intergranular cracking originating in the relief radius of Primary Reaction Control System (PCRS) Thrusters. Of particular concern is deep cracking in this area which could lead to combustion leakage in the event of through wall cracking from the relief radius into an acoustic cavity of the combustion chamber. In order to reliably detect such defects while ensuring minimal false positives during inspection, the Orthogonal Probe Eddy Current (OPEC) system has been developed and an extensive validation study performed. This report describes the validation procedure, sample set, and inspection results as well as comparing validation flaws with the response from naturally occuring damage.

Wincheski, Russell A.↗

An investigation of gear mesh failure prediction techniques

A study was performed in which several gear failure prediction methods were investigated and applied to experimental data from a gear fatigue test apparatus. The primary objective was to provide a baseline understanding of the prediction methods and to evaluate their diagnostic capabilities. The methods investigated use the signal average in both the time and frequency domain to detect gear failure. Data from eleven gear fatigue tests were recorded at periodic time intervals as the gears were run from initiation to failure. Four major failure modes, consisting of heavy wear, tooth breakage, single pits, and distributed pitting were observed among the failed gears. Results show that the prediction methods were able to detect only those gear failures which involved heavy wear or distributed pitting. None of the methods could predict fatigue cracks, which resulted in tooth breakage, or single pits. It is suspected that the fatigue cracks were not detected because of limitations in data acquisition rather than in methodology. Additionally, the frequency response between the gear shaft and the transducer was found to significantly affect the vibration signal. The specific frequencies affected were filtered out of the signal average prior to application of the methods.

Zakrajsek, James J.↗