Nanoscale Consequences of Irradiation Investigated by RAD-AFM (Final Report)

To assess the feasibility of measuring material property changes induced by ion irradiation one pristine and three legacy HT-9 samples were sectioned and polished. The polish protocol was first optimized using a pristine unirradiated HT-9 sample before polishing the ion irradiated samples as the spot size was small and repeated polishing could remove the ion irradiated region entirely. AFM tapping mode was used to assess the surface quality after each polish. AFM based hardness mapping was optimized for new diamond tips specifically for use with the HT-9 samples to compensate for differences in grain size, precipitates, and heterogeneity of hardness relative to past samples. In addition, a hardness calibration protocol was developed using NIST copper, nickel, and steel reference materials. Co-located SEM-EDS and AFM analysis was used to verify the ion irradiated edge using the silver/tungsten coating as a fiducial mark. Once benchmarked, the hardness across the ion irradiated cross section, a comparison of bulk hardness according to neutron irradiation, and the hardness of the ion irradiated surface edge was measured.

36 MATERIALS SCIENCE↗

Validation Exercise of a Coarse Finite Element Model of Laser Welds

The objective of this project is to validate low-fidelity models of 304L to 304L stainless steel partial-penetration laser welds for thin sheets. Low-fidelity means that the weld is represented by coarsely meshed element blocks. Here, the hexahedral element size is approx imately half the weld penetration depth. The material behavior of the block is represented by a J2 plasticity model with a Voce hardening function. The source of the data used in this work is an extensive experimental study conducted by Sharlotte Kramer (1528) and published in 2015. Figure 1 shows a cross-section of the weld of interest. The nominal thickness of the sheets is 0.063 in. while the target penetration depth of the weld is in the range of 0.028 to 0.032 in., extending about half the sheet thickness. Uniaxial tension tests provided data for calibration of base material and weld models. Results of two validation geometries were also provided. The principal validation geometry is shown in Fig. 2. It consists of a plate specimen with in-plane dimensions 6 in × 2.875 in loaded in tension. A circular plug with a 1.5 in. diameter was cut from the center of the plate and then welded in place. The details of the welding schedule are given. An important assumption is that the welds in the calibration and validation specimens have similar geometric and material properties as those in the validation tests. The task was to first calibrate models for the base material and the welds and then simulate the validation tests until the point of weld first failure.

36 MATERIALS SCIENCE↗

Gamma and Neutron Measurement and Modeling of Irradiated TRISO Fuel

Given the unique characteristics of the PBR fuel cycle, both gamma and neutron measurements are expected to play important roles in performing and maintaining nuclear material control and accounting for spent pebbles to safeguard the fuel cycle. Given the lack of irradiated pebbles in the US, a variety of irradiated TRISO fuel samples with wide ranges of burnups and cooling times available at ORNL were used in this work. A large number of gamma and neutron measurements have been performed on these samples to collect data to test the various detectors and to benchmark the computer models to simulate the depletion and decay of the fuel and the measurements themselves. Two neutron detectors, including a custom-made detector and the Very High-Performance Neutron Multiplicity Counting, were used to measure the neutrons emitted by these TRISO samples. Three gamma spectrometry detectors, including an HPGe and the M400 CZT detector, were used to measure gamma-ray emissions from these samples. The M400 was recently adopted by the IAEA for fresh uranium measurements, but it was tested for spent fuel measurements prior to this project. Detailed MCNP models were developed to simulate these neutron and gamma measurements. Some GADRAS models were also developed to cross check the MCNP models for the gamma measurements. It was found challenging to perform neutron measurements in the hot cell due to the high background counts. Close agreements were observed between the simulated and measured neutron count rates in both detectors’ measurements of californium calibration sources. Both the HPGe and M400 detectors were able to measure the 604 and 662 keV peaks from these samples, which are the two most important peaks used to infer fuel burnup. Although the M400 detector did not have nearly good energy resolution and did not detect some of the minor peaks as the HPGe detector, it was found to be capable of handling significantly higher dose rates than HPGe. Given the complexities in the TRISO samples (e.g., different samples sizes) and uncertainties in the alignments between the detector and the TRISO fuel inside the containers, large scatters were found between the peak area rates and the samples’ burnups. However, the 604/662 peak ratios were found to trend well with the samples’ burnups among most samples in both measured and simulated results.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Calibration of the sub-aperture backscatter system on OMEGA EP

The sub-aperture backscatter (SABS) diagnostic on the OMEGA EP Laser System is a diagnostic that is used to measure the backscattered and sidescattered light during laser–plasma interaction experiments that are relevant to high-energy-density physics and inertial confinement fusion. The diagnostic collects stimulated Brillouin scattering (SBS) UV light at around 351 nm and stimulated Raman scattering (SRS) in the visible-light regime in the 420–720-nm-wavelength range and provides spectrally and temporally resolved information. Five 1-in. light collectors, composed of a lens, ground glass diffuser, and coupling into a 300-μm fiber, are positioned behind the last steering mirror on one of the four beamlines to catch a portion of the beam cross section (~1.5%) of the emission that is scattered into the beamline. The SRS light is collected in two light collectors, combined, and transported via graded index fibers to a streaked spectrometer. The SABS-SRS streak spectrometer has a temporal and spectral resolution of 100 ps and 1 nm, respectively. Three other light collectors collect, combine, and transport the SBS signal to a Hamamatsu high-voltage photodiode, where an oscilloscope digitizes the data, providing a time resolution of better than 1 ns. To obtain an absolute energy calibration of SRS measurements, light signals of known energy and wavelength were injected into the light collectors one at a time. The resulting counts on the streak camera charge-coupled device for SRS are then correlated with the incident fluence of scattered light at the light collector in order to allow a quantitative assessment of streak camera sensitivity to determine the energy of the scattered light during experiments. The measurements were performed in situ from the light collectors to the detectors. Other offline measurements provided the transmission of the optics between the target chamber center and the light collectors.

47 OTHER INSTRUMENTATION↗

The Gaia EDR3 view of Johnson-Kron-Cousins standard stars: the curated Landolt and Stetson collections

In the era of large surveys and space missions, it is necessary to rely on large samples of well-characterized stars for inter-calibrating and comparing measurements from different surveys and catalogues. Among the most employed photometric systems, the Johnson-Kron-Cousins has been used for decades and for a large amount of important datasets. Our goal is to profit from the Gaia EDR3 data, Gaia official cross-match algorithm, and Gaia -derived literature catalogues, to provide a well-characterized and clean sample of secondary standards in the Johnson-Kron-Cousins system, as well as a set of transformations between the main photometric systems and the Johnson-Kron-Cousins one. Using Gaia as a reference, as well as data from reddening maps, spectroscopic surveys, and variable stars monitoring surveys, we curated and characterized the widely used Landolt and Stetson collections of more than 200 000 secondary standards, employing classical as well as machine learning techniques. In particular, our atmospheric parameters agree significantly better with spectroscopic ones, compared to other machine learning catalogues. We also cross-matched the curated collections with the major photometric surveys to provide a comprehensive set of reliable measurements in the most widely adopted photometric systems. We provide a curated catalogue of secondary standards in the Johnson-Kron-Cousins system that are well-measured and as free as possible from variable and multiple sources. We characterize the collection in terms of astrophysical parameters, distance, reddening, and radial velocity. We provide a table with the magnitudes of the secondary standards in the most widely used photometric systems (ugriz, grizy, Gaia , HIPPARCOS, Tycho , 2MASS). We finally provide a set of 167 polynomial transformations, valid for dwarfs and giants, metal-poor and metal-rich stars, to transform UBVRI magnitudes in the above photometric systems and vice-versa.

79 ASTRONOMY AND ASTROPHYSICS↗

Conceptual design of a Doppler spectrometer for 102 m/s cross-field flows in tokamak divertors

The cross-field transport in the scrape-off-layers (SOLs) and divertors in tokamaks is of a similar size to the poloidal component of the parallel flow, thereby significantly impacting the plasma transport there. However, its direct observation has been challenging because the drift velocity (102–103 m/s) is significantly below the detection limit of conventional diagnostics. To realize cross-field ion flow measurement, a variety of systematic uncertainties in the system must be narrowed down. Here, we develop a conceptual design of the Doppler spectrometry that enables us to measure the impurity flows with 102-m/s accuracy based on an in situ wavelength-calibration technique developed in the astrophysics field, the iodine-cell method. We discuss its properties and applicability. In particular, the scaling relation between wavelength accuracy and various spectroscopic parameters is newly presented, which suggests the high importance of the wavelength resolution of the system. Based on transport simulations for the JT-60SA divertor, the feasibility of the system is assessed.

Fujii, Keisuke↗

Scintillating Bubble Chambers for Rare Event Searches

The Scintillating Bubble Chamber (SBC) collaboration is developing liquid-noble bubble chambers for the detection of sub-keV nuclear recoils. These detectors benefit from the electron recoil rejection inherent in moderately-superheated bubble chambers with the addition of energy reconstruction provided from the scintillation signal. The ability to measure low-energy nuclear recoils allows the search for GeV-scale dark matter and the measurement of coherent elastic neutrino-nucleus scattering on argon from MeV-scale reactor antineutrinos. The first physics-scale detector, SBC-LAr10, is in the commissioning phase at Fermilab, where extensive engineering and calibration studies will be performed. In parallel, a functionally identical low-background version, SBC-SNOLAB, is being built for a dark matter search underground at SNOLAB. SBC-SNOLAB, with a 10 kg-yr exposure, will have sensitivity to a dark matter–nucleon cross section of 2×10 –42 cm 2 at 1 GeV/c 2 dark matter mass, and future detectors could reach the boundary of the argon neutrino fog with a tonne-yr exposure. In addition, the deployment of an SBC detector at a nuclear reactor could enable neutrino physics investigations including measurements of the weak mixing angle and searches for sterile neutrinos, the neutrino magnetic moment, and the light Z’ gauge boson.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of supernova magnitude fluctuations induced by large-scale structure

The peculiar velocities of supernovae and their host galaxies are correlated with the large-scale structure of the Universe, and can be used to constrain the growth rate of structure and test the cosmological model. In this work, we measure the correlation statistics of the large-scale structure traced by the Dark Energy Spectroscopic Instrument Bright Galaxy Survey Data Release 1 sample, and magnitude fluctuations of type Ia supernova from the Pantheon+ compilation across redshifts z < 0.1. We find a detection of the cross-correlation signal between galaxies and type Ia supernova magnitudes. Fitting the normalised growth rate of structure f sigma_8 to the auto- and cross-correlation function measurements we find f sigma_8 = 0.384 +0.094 -0.157, which is consistent with the Planck LambdaCDM model prediction, and indicates that the supernova magnitude fluctuations are induced by peculiar velocities. Using a large ensemble of N-body simulations, we validate our methodology, calibrate the covariance of the measurements, and demonstrate that our results are insensitive to supernova selection effects. We highlight the potential of this methodology for measuring the growth rate of structure, and forecast that the next generation of type Ia supernova surveys will improve f sigma_8 constraints by a further order of magnitude.

Nguyen, A. [Swinburne U., Ctr. Astrophys. Supercom↗

Nonlinear light-output calibration of the oxygenated xylene scintillators used in OMEGA neutron time-of-flight spectrometers

Neutron time-of-flight (nTOF) spectrometers are essential instruments for measuring and evaluating the performance of inertial confinement fusion implosions. The neutron spectrometers utilized for the OMEGA laser include two liquid-based scintillators, each consisting of a large volume filled with xylene that is coupled to four photomultiplier tubes. Analysis of the signal from these detectors requires detailed knowledge of the scintillator’s light output, which is needed to fit the nTOF spectrum, from which the neutron energy spectrum is informed. The light output is nonlinearly proportional to the neutron energy, which, in turn, affects the interpretation of the neutron energy spectrum from a TOF signal. A recent campaign on OMEGA was performed to calibrate the xylene detectors and infer the shape of the light-output curve. The campaign utilized materials with increasing Z placed in the OMEGA target chamber to initiate scattering events with the 14 MeV fusion neutrons. This process leads to the production of backscatter neutrons of varying energies that appear as peaks in the nTOF data. Simulations using a neutron transport code were combined with the measured deuterium–tritium neutron yields to calculate the expected backscattered neutron yields from the well-known scattering cross sections of each material. Furthermore, the neutron-energy dependent light output of the scintillator inferred from the experiment is compared to the light-output curve simulated with a neutron transport code for the following neutron energies: 1.5, 2.5, 6, and 14 MeV.

47 OTHER INSTRUMENTATION↗

Lightning radiometry in visible and infrared bands

Calibrated measurements of lightning optical emissions are critical for both quantifying the impacts of lightning in our atmosphere and devising detection instruments with sufficient dynamic range capable of yielding close to 100% detection efficiency. However, to date, there is only a limited number of investigations that have attempted to take such calibrated measurements. Here, in this work, we report the power radiated by lightning in both visible and infrared bands, assuming isotropic emission, and accounting for atmospheric absorption. More precisely, we report peak radiated power and total radiated energy in the combined visible plus near-infrared range (VNIR, 0.34–1.1 μm), around the H α line (652–667 nm), and for the 2–2.5 μm infrared band. The estimated peak power and total energy radiated by negative cloud-to-ground return strokes in the VNIR range is 130 MW and 20 kJ, respectively. Additionally, we detected peak radiated powers of 12 and 0.19 MW in the H α and infrared bands, respectively. We cross-reference the optical data set with peak current reported by a lightning detection network. The resulting trend is that optical power emitted around the H α line scales with peak return stroke current according to a power law with exponent equal to 1.25. This trend, which should be approximately true across the entire visible spectrum, can be attributed to the plasma negative differential resistance of the lightning return stroke channel. We conclude by discussing the challenges in performing calibrated measurements of lightning optical power in different bands and comparing the results with previously-collected data with different experimental setups, observation conditions, and calibration methods.

54 ENVIRONMENTAL SCIENCES↗

Search for electron-neutrino transitions to sterile states in the BEST experiment

The Baksan Experiment on Sterile Transitions (BEST) probes the gallium anomaly and its possible connections to oscillations between active and sterile neutrinos. Based on the Gallium-Germanium Neutrino Telescope (GGNT) technology of the SAGE experiment, BEST employs two zones of liquid Ga target to explore neutrino oscillations on the meter scale. Oscillations on this short scale could produce deficits in the 71 Ge production rates within the two zones, as well as a possible rate difference between the zones. From July 5th to October 13th 2019, the two-zone target was exposed to a primarily monoenergetic, 3.4-MCi 51 Cr neutrino source 10 times for a total of 20 independent 71 Ge extractions from the two Ga targets. The 71 Ge production rates from the neutrino source were measured from July 2019 to March 2020. At the end of these measurements, the counters were filled with 71 Ge doped gas and calibrated during November 2020. In this paper, results from the BEST sterile neutrino oscillation experiment are presented in details. The ratio of the measured 71 Ge production rates to the predicted rates for the inner and the outer target volumes are calculated from the known neutrino capture cross section. Comparable deficits in the measured ratios relative to predicted values are found for both zones, with the 4⁢𝜎 deviations from unity consistent with the previously reported gallium anomaly. Finally, if interpreted in the context of neutrino oscillations, the deficits give best-fit oscillation parameters of Δ⁢𝑚 2 = 3.3$^{+∞}{−2.3}$ eV 2 and sin 2 ⁡2⁢𝜃 = 0.42$^{+0.15}{−0.17}$, consistent with 𝜈 𝑒 →𝜈 𝑠 oscillations governed by a surprisingly large mixing angle.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Decoding Golden Eagle Movement Behavior from High-Resolution, Variable-Rate Telemetry Data Through Bayesian Filtering

The recent advances in animal tracking technology have enabled the collection of a vast amount of in situ data regarding the movement of wildlife at high spatiotemporal resolution. These data are usually available at variable time resolutions and contains noise (error) originating from GPS fixes. Decoding movement characteristics, particularly of flying animals, from telemetry data while handling these factors is a challenging yet important task for conservation purposes. Typically, this task is broken into two subtasks: resampling, and model calibration. The resampling subtask converts the variable rate positional data into a constant time interval data, while the model calibration subtask uses the resampled data to tune time-invariant parameters of the proposed models. For telemetry data at high temporal resolutions (order of 1 second), it is very challenging to decouple noise from actual movements using interpolation-based resampling techniques. Any errors introduced during resampling can significantly alter the the calibration and prediction attributes of the movement model. We address this problem through a unified Bayesian state-space framework that can handle both the resampling and calibration tasks in a single step. In addition, we use the speed and heading of the bird from telemetry data to regularize the position information of the bird. We use a Kalman filtering approach to include these nonlinearly related motion parameters within the state space framework. We cross-validated to quantify how this inclusion affects the model performance in estimating true bird movements. The relationship between the true state of the bird and environmental and topographical covariates is then represented parametrically. These parameters are then tuned using stochastic sampling strategies like Markov Chain Monte Carlo (MCMC). We use the telemetry data collected from golden eagles in the western USA to demonstrate the applicability of this approach to build a predictive, probabilistic movement model. Our preliminary results show that this approach provides improved predictive performance in terms of capturing higher-order motion parameters such as angular and horizontal accelerations, which may have simpler and more direct relationships with environmental covariates than corresponding speeds. In this talk, we will demonstrate how this state-space approach benefits the prediction capabilities of a movement model in simulating golden eagle paths through a wind power plant in Wyoming given certain atmospheric conditions. The model outcomes are aimed at informing mitigation strategies that can minimize the potential for collisions of golden eagles with wind turbines.

Bayesian methods↗

Planting a Lyman alpha forest on ABACUSSUMMIT

The full-shape correlations of the Lyman alpha (Ly$α$) forest contain a wealth of cosmological information through the Alcock Paczynski effect. However, these measurements are challenging to model without robustly testing and verifying the theoretical framework used for analyzing them. Here, we leverage the accuracy and volume of the $N$-body simulation suite ABACUSSUMMIT to generate high-resolution Ly$α$ skewers and quasi-stellar object (QSO) catalogs. One of the main goals of our mocks is to aid in the full-shape Ly$α$ analysis planned by the Dark Energy Spectroscopic Instrument (DESI) team. We provide optical depth skewers for six of the fiducial cosmology base-resolution simulations ($L$ box = 2 $h$ -1 Gpc, $N$ = 6912 3 ) at $z$ = 2.5. We adopt a simple recipe based on the Fluctuating Gunn-Peterson Approximation (FGPA) for constructing these skewers from the matter density in an $N$-body simulation and calibrate it against the 1D and 3D Ly$α$ power spectra extracted from the hydrodynamical simulation IllustrisTNG (TNG; $L$ box = 205 $h$ -1 Mpc, $N$ = 2500 3 ). As an important application, we study the non-linear broadening of the baryon acoustic oscillation (BAO) peak and show the cross-correlation between DESI-like QSOs and our Ly$α$ forest skewers. We find differences on small scales between the Kaiser approximation prediction and our mock measurements of the Ly$α$×QSO cross-correlation, which would be important to account for in upcoming analyses. The ABACUSSUMMIT Ly$α$ forest mocks open up the possibility for improved modelling of cross correlations between Ly$α$ and cosmic microwave background (CMB) lensing and Ly$α$ and QSOs, and for forecasts of the 3-point Ly$α$ correlation function. Furthermore, our catalogues and skewers are publicly available on Globus via the National Energy Research Scientific Computing Center (NERSC) (full link under Data Availability).

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluating the Effects of Detector Modeling Uncertainties on Sterile Neutrino Oscillation Analysis with the ICARUS Detector

he ICARUS T600 LArTPC detector was refurbished after an initial run at the underground LNGS labs and is currently taking data within its experimental hall at Fermilab after full commissioning. Regular data taking began in May 2021 with neutrinos from the Booster Neutrino Beam (BNB) and the Neutrinos at the Main Injector (NuMI) off-axis beam. As the far detector of the Short-Baseline Neutrino (SBN) Program, the ICARUS detector's capability in searching for both muon neutrino disappearance and electron neutrino appearance will allow for unprecedented sensitivity to light sterile neutrinos with eV-scale mass. The ultimate sensitivity of the detector to sterile neutrino oscillations depends on the understanding of the detector response and the uncertainties remaining after calibrating the detector model. This poster will review how detector-model-related uncertainties are quantified, evaluated and their impact on expected sterile neutrino oscillation sensitivities using the existing ICARUS data. The work pursued here is broadly applicable to other ICARUS analysis pathways such as neutrino-argon cross-sections and Beyond the Standard Model physics searches. It will finally discuss improvement pathways to reduce the systematic uncertainties to the level needed for the joint sterile neutrino oscillation analysis with the Short Baseline Near Detector (SBND) within the SBN Program.

43 PARTICLE ACCELERATORS↗

Lensing without borders – I. A blind comparison of the amplitude of galaxy–galaxy lensing between independent imaging surveys

ABSTRACT Lensing without borders is a cross-survey collaboration created to assess the consistency of galaxy–galaxy lensing signals (ΔΣ) across different data sets and to carry out end-to-end tests of systematic errors. We perform a blind comparison of the amplitude of ΔΣ using lens samples from BOSS and six independent lensing surveys. We find good agreement between empirically estimated and reported systematic errors which agree to better than 2.3σ in four lens bins and three radial ranges. For lenses with zL > 0.43 and considering statistical errors, we detect a 3–4σ correlation between lensing amplitude and survey depth. This correlation could arise from the increasing impact at higher redshift of unrecognized galaxy blends on shear calibration and imperfections in photometric redshift calibration. At zL > 0.54, amplitudes may additionally correlate with foreground stellar density. The amplitude of these trends is within survey-defined systematic error budgets that are designed to include known shear and redshift calibration uncertainty. Using a fully empirical and conservative method, we do not find evidence for large unknown systematics. Systematic errors greater than 15 per cent (25 per cent) ruled out in three lens bins at 68 per cent (95 per cent) confidence at z < 0.54. Differences with respect to predictions based on clustering are observed to be at the 20–30 per cent level. Our results therefore suggest that lensing systematics alone are unlikely to fully explain the ‘lensing is low’ effect at z < 0.54. This analysis demonstrates the power of cross-survey comparisons and provides a promising path for identifying and reducing systematics in future lensing analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Low-energy physics in neutrino LArTPCs

Here, in this paper, we review scientific opportunities and challenges related to detection and reconstruction of low-energy (less than 100 MeV) signatures in liquid argon time-projection chamber (LArTPC) neutrino detectors. LArTPC neutrino detectors designed for performing precise long-baseline oscillation measurements with GeV-scale accelerator neutrino beams also have unique sensitivity to a range of physics and astrophysics signatures via detection of event features at and below the few tens of MeV range. In addition, low-energy signatures are an integral part of GeV-scale accelerator neutrino interaction final-states, and their reconstruction can enhance the oscillation physics sensitivities of LArTPC experiments. New physics signals from accelerator and natural sources also generate diverse signatures in the low-energy range, and reconstruction of these signatures can increase the breadth of Beyond the Standard Model scenarios accessible in LArTPC-based searches. A variety of experimental and theory-related challenges remain to realizing this full range of potential benefits. Neutrino interaction cross-sections and other nuclear physics processes in argon relevant to sub-hundred-MeV LArTPC signatures are poorly understood, and improved theory and experimental measurements are needed; pion decay-at-rest sources and charged particle and neutron test beams are ideal facilities for improving this understanding. There are specific calibration needs in the low-energy range, as well as specific needs for control and understanding of radiological and cosmogenic backgrounds. Low-energy signatures, whether steady-state or part of a supernova burst or larger GeV-scale event topology, have specific triggering, DAQ and reconstruction requirements that must be addressed outside the scope of conventional GeV-scale data collection and analysis pathways. Novel concepts for future LArTPC technology that enhance low-energy capabilities should also be explored to help address these challenges.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Accuracy limitations for composition analysis by XPS using relative peak intensities: LiF as an example

Although precision in XPS can be excellent, allowing small changes to be easily observed, obtaining accurate absolute elemental composition of a solid material from relative peak intensities is generally much more problematical, involving many factors: background removal; differing analysis depths at different photoelectron kinetic energies; possible angular distribution effects; calibration of the instrument transmission function, and variations of the distribution of the photoelectron intensity between “main” peaks (those usually used for analysis) and associated substructure following the main peak, as a function of the chemical bonding of the elements concerned. The last item, coupled with the use of photoionization cross-sections and/or relative sensitivity factors, is the major subject of this paper, though it is necessary to consider the other items also, using LiF as a test case. The results show that the above issues, which are relevant to differing degrees in most XPS analyses, present significant challenges to highly accurate XPS quantification.

Brundle, Christopher R.↗