Search NASA⌕ Search

SEARCH · Search NASA

Results for “deconvolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Searching for correlations between vibrational spectral features and structural parameters of silicate glass network

Infrared (IR) and Raman spectroscopic features of silicate glasses are usually interpreted based on the analogy with those of smaller molecules, molecular clusters, or crystalline counterparts; this study tests the accuracy and validity of these widely cited peak assignment schemes by comparing vibrational spectral features with bond parameters of the glass network created by molecular dynamics (MD) simulations. A series of sodium silicate glasses with compositions of [Na 2 O] x [Al 2 O 3 ] 2 [SiO 2 ] 98- x with x = 7, 12, 17, and 22 were synthesized and analyzed with IR and Raman. A silica glass substrate and a crystalline quartz were also analyzed for comparison. Glass structures with the same compositions were generated with MD simulations using three types of potentials: fixed partial charge pairwise (Teter), partial diffuse charge potential (MGFF), and bond order-based charge transfer potential (ReaxFF). The comparison of simulated and experimental IR spectra showed that, among these three potentials tested, ReaxFF reproduces the concentration dependence of spectral features closest to the experimentally observed trend. Hence, the bond length and angle distributions as well as Si– Q n species and ring size distributions of silica and sodium silicate glasses were obtained from ReaxFF-MD simulations and further compared with the peak assignment or deconvolution schemes—which have been widely used since 1970s and 1980s—(a) correlation between the IR peak position in the Si–O stretch region (1050-1120 cm -1 ) and the Si–O–Si bond angle; (b) deconvolution of the Raman bands in the Si–O stretch region with the Q n speciation; and (c) assignment of the Raman bands in the 420-600 cm -1 region to the bending modes of (SiO) n rings with different sizes (typically, n = 3-6). The comparisons showed that none of these widely used methods is congruent with the bond parameters or structures of silicate glass networks produced via ReaxFF-MD simulations. This result invokes that the adequacy of these spectral interpretation methods must be questioned. Alternative interpretations are proposed, which are to be tested independently in future studies.

36 MATERIALS SCIENCE↗

Practical considerations in using a binary pseudorandom array for instrument transfer function calibration

Binary pseudo-random array (BPRA) artifacts are useful devices for calibrating the instrument transfer function (ITF) of interferometric microscopes and other optical and non-optical surface and wavefront measurement instruments. The intrinsic white noise character of the power spectral density function of the artifact simplifies the deconvolution of the ITF from the measured power spectral density (PSD). However, resampling of the BPRA intrinsic artifact features with the measurement tool's specific sampling pattern modifies the white noise character of the intrinsic spectrum and needs to be accounted for in the ITF-based data deconvolution process. We have developed an analytic solution to the spectrum of a resampled one- and two- dimensional BPRA. The resultant nominal PSD function is a simple twoparameter cosine function with a period equal to the resampled pixel width. A transfer function model for interferometric microscopes that incorporates this function, along with an ITF that includes aliasing effects and variable numerical aperture (NA), wavelength, and obscuration factor, is used to fit to the BPRA PSDs measured by an interference microscope for a range of objective and zoom lens magnification combinations.

Takacs, PZ↗

Semi-empirical procedures for correcting detector size effect on clinical MV x-ray beam profiles

The measured radiation beam profiles need to be corrected for the detector size effect to derive the real profiles. This paper describes two new semi-empirical procedures to determine the real profiles of high-energy x-ray beams by removing the detector size effect from the measured profiles. Measured profiles are corrected by shifting the position of each measurement point by a specific amount determined from available theoretical and experimental knowledge in the literature. The authors developed two procedures to determine the amount of shift. In the first procedure, which employs the published analytical deconvolution procedure of other investigators, the shift is determined from the comparison of the analytical fit of the measured profile and the corresponding analytical real profile derived from the deconvolution of the fitted measured profile and the Gaussian detector response function. In the second procedure, the amount of shift at any measurement point is considered to be proportional to the value of an analytical function related to the second derivative of the real profile at that point. The constant of proportionality and a parameter in the function are obtained from the values of the shifts at the 90%, 80%, 20%, and 10% dose levels, which are experimentally known from the published results of other investigators to be approximately equal to half of the radius of the detector. These procedures were tested by correcting the profiles of 6 and 18 MV x-ray beams measured by three different ionization chambers and a stereotactic field diode detector with 2.75, 2, 1, and 0.3 mm radii of their respective active cylindrical volumes. The corrected profiles measured by different detectors are found to be in close agreement. The detector size corrected penumbra widths also agree with the expected values based on the results of an earlier investigation. Thus, the authors concluded that the proposed procedures are accurate and can be used to derive the real profiles of clinical high-energy x-ray beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of the setup dependence of detector response functions for mega-voltage linear accelerators

Purpose: Accurate modeling of beam profiles is important for precise treatment planning dosimetry. Calculated beam profiles need to precisely replicate profiles measured during machine commissioning. Finite detector size introduces perturbations into the measured profiles, which, in turn, impact the resulting modeled profiles. The authors investigate a method for extracting the unperturbed beam profiles from those measured during linear accelerator commissioning. Methods: In-plane and cross-plane data were collected for an Elekta Synergy linac at 6 MV using ionization chambers of volume 0.01, 0.04, 0.13, and 0.65 cm{sup 3} and a diode of surface area 0.64 mm{sup 2}. The detectors were orientated with the stem perpendicular to the beam and pointing away from the gantry. Profiles were measured for a 10x10 cm{sup 2} field at depths ranging from 0.8 to 25.0 cm and SSDs from 90 to 110 cm. Shaping parameters of a Gaussian response function were obtained relative to the Edge detector. The Gaussian function was deconvolved from the measured ionization chamber data. The Edge detector profile was taken as an approximation to the true profile, to which deconvolved data were compared. Data were also collected with CC13 and Edge detectors for additional fields and energies on an Elekta Synergy, Varian Trilogy, and Siemens Oncor linear accelerator and response functions obtained. Response functions were compared as a function of depth, SSD, and detector scan direction. Variations in the shaping parameter were introduced and the effect on the resulting deconvolution profiles assessed. Results: Up to 10% setup dependence in the Gaussian shaping parameter occurred, for each detector for a particular plane. This translated to less than a {+-}0.7 mm variation in the 80%-20% penumbral width. For large volume ionization chambers such as the FC65 Farmer type, where the cavity length to diameter ratio is far from 1, the scan direction produced up to a 40% difference in the shaping parameter between in-plane and cross-plane measurements. This is primarily due to the directional difference in penumbral width measured by the FC65 chamber, which can more than double in profiles obtained with the detector stem parallel compared to perpendicular to the scan direction. For the more symmetric CC13 chamber the variation was only 3% between in-plane and cross-plane measurements. Conclusions: The authors have shown that the detector response varies with detector type, depth, SSD, and detector scan direction. In-plane vs cross-plane scanning can require calculation of a direction dependent response function. The effect of a 10% overall variation in the response function, for an ionization chamber, translates to a small deviation in the penumbra from that of the Edge detector measured profile when deconvolved. Due to the uncertainties introduced by deconvolution the Edge detector would be preferable in obtaining an approximation of the true profile, particularly for field sizes where the energy dependence of the diode can be neglected. However, an averaged response function could be utilized to provide a good approximation of the true profile for large ionization chambers and for larger fields for which diode detectors are not recommended.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sparse-view proton computed tomography using modulated proton beams

Purpose: Proton imaging that uses a modulated proton beam and an intensity detector allows a relatively fast image acquisition compared to the imaging approach based on a trajectory tracking detector. In addition, it requires a relatively simple implementation in a conventional proton therapy equipment. The model of geometric straight ray assumed in conventional computed tomography (CT) image reconstruction is however challenged by multiple-Coulomb scattering and energy straggling in the proton imaging. Radiation dose to the patient is another important issue that has to be taken care of for practical applications. In this work, the authors have investigated iterative image reconstructions after a deconvolution of the sparsely view-sampled data to address these issues in proton CT. Methods: Proton projection images were acquired using the modulated proton beams and the EBT2 film as an intensity detector. Four electron-density cylinders representing normal soft tissues and bone were used as imaged object and scanned at 40 views that are equally separated over 360°. Digitized film images were converted to water-equivalent thickness by use of an empirically derived conversion curve. For improving the image quality, a deconvolution-based image deblurring with an empirically acquired point spread function was employed. They have implemented iterative image reconstruction algorithms such as adaptive steepest descent-projection onto convex sets (ASD-POCS), superiorization method–projection onto convex sets (SM-POCS), superiorization method–expectation maximization (SM-EM), and expectation maximization-total variation minimization (EM-TV). Performance of the four image reconstruction algorithms was analyzed and compared quantitatively via contrast-to-noise ratio (CNR) and root-mean-square-error (RMSE). Results: Objects of higher electron density have been reconstructed more accurately than those of lower density objects. The bone, for example, has been reconstructed within 1% error. EM-based algorithms produced an increased image noise and RMSE as the iteration reaches about 20, while the POCS-based algorithms showed a monotonic convergence with iterations. The ASD-POCS algorithm outperformed the others in terms of CNR, RMSE, and the accuracy of the reconstructed relative stopping power in the region of lung and soft tissues. Conclusions: The four iterative algorithms, i.e., ASD-POCS, SM-POCS, SM-EM, and EM-TV, have been developed and applied for proton CT image reconstruction. Although it still seems that the images need to be improved for practical applications to the treatment planning, proton CT imaging by use of the modulated beams in sparse-view sampling has demonstrated its feasibility.

60 APPLIED LIFE SCIENCES↗

Acoustic time-of-flight for proton range verification in water

Purpose: Measurement of the arrival times of thermoacoustic waves induced by pulsed proton dose depositions (protoacoustics) may provide a proton range verification method. The goal of this study is to characterize the required dose and protoacoustic proton range (distance) verification accuracy in a homogeneous water medium at a hospital-based clinical cyclotron. Methods: Gaussian-like proton pulses with 17 μs widths and instantaneous currents of 480 nA (5.6 × 10{sup 7} protons/pulse, 3.4 cGy/pulse at the Bragg peak) were generated by modulating the cyclotron proton source with a function generator. After energy degradation, the 190 MeV proton pulses irradiated a water phantom, and the generated protoacoustic emissions were measured by a hydrophone. The detector position and proton pulse characteristics were varied. The experimental results were compared to simulations. Different arrival time metrics derived from acoustic waveforms were compared, and the accuracy of protoacoustic time-of-flight distance calculations was assessed. Results: A 27 mPa noise level was observed in the treatment room during irradiation. At 5 cm from the proton beam, an average maximum pressure of 5.2 mPa/1 × 10{sup 7} protons (6.1 mGy at the Bragg peak) was measured after irradiation with a proton pulse with 10%–90% rise time of 11 μs. Simulation and experiment arrival times agreed well, and the observed 2.4 μs delay between simulation and experiment is attributed to the difference between the hydrophone’s acoustic and geometric centers. Based on protoacoustic arrival times, the beam axis position was measured to within (x, y) = (−2.0, 0.5) ± 1 mm. After deconvolution of the exciting proton pulse, the protoacoustic compression peak provided the most consistent measure of the distance to the Bragg peak, with an error distribution with mean = − 4.5 mm and standard deviation = 2.0 mm. Conclusions: Based on water tank measurements at a clinical hospital-based cyclotron, protoacoustics is a potential method for measuring the beam’s position (x and y within 2.0 mm) and Bragg peak range (2.0 mm standard deviation), although range verification will require simulation or experimental calibration to remove systematic error. Based on extrapolation, a protoacoustic arrival time reproducibility of 1.5 μs (2.2 mm) is achievable with 2 Gy of total deposited dose. Of the compared methods, deconvolution of the excitation proton pulse is the best technique for extracting protoacoustic arrival times, particularly if there is variation in the proton pulse shape.

07 ISOTOPE AND RADIATION SOURCES↗

Multi-Scale Modeling of Hydrogen Transport in a Porous Fuel Cell Anode

Proton-exchange-membrane fuel cells (PEMFC) are a clean energy conversion alternative to traditional fossil-fuel combustion; however, transport resistances in the electrode pose a lower-limit to catalyst loading and commercialization of PEMFCs. PEMFCs consist of simultaneous hydrogen (H 2 ) oxidation and oxygen (O 2 ) reduction at the anode and cathode, respectively. Here, while oxygen transport resistances in PEMFCs have been widely studied both experimentally and analytically, hydrogen transport resistances are less understood. Herein, we present a physics-based model that encompasses multi-scale transport within the anode side of the PEMFC. The O 2 in the cathode here is omitted and replaced with H 2 to deconvolute O 2 transport resistance contributions, similar to that of a hydrogen pump. Replication of the hydrogen pump setup allows for comparison of the model against experimental analysis of H 2 gas-transport resistance in H 2 limiting-current experiments, which can also inform gas transport (including oxygen) in general. Herein, we present a multi-scale analytical model of the porous anode catalyst layers and individual catalyst agglomerates that enables determination of the effects of electrode morphology such as agglomerate size, catalyst loading, etc. on H 2 transport resistance through the porous electrode to complement and better understand H 2 limiting current experiments and deconvolute local H 2 transport resistances.

Zhang, Rosa↗

Environmental Molecular Network (ENVnet) v1

Here, we present an approach that integrates mass difference based deconvolution with molecular networking to build a static reference network from all publicly available organic matter metabolomics datasets. This is accomplished using MS/MS deconvolution coupled with both recently reported (BUDDY) and novel machine learning algorithms to determine chemical formulas and perform MS/MS alignments (REM-BLINK).

Bowen, Benjamin↗

STM/S Grid LDOS Data and Analysis Code for Deciphering Majorana Zero Modes in Topological Superconductor

This dataset provides raw millikelvin scanning tunneling microscopy/spectroscopy (STM/S) grid spectroscopy data and Python analysis scripts supporting the manuscript “Deciphering Majorana Zero Modes in Topological Superconductor FeTe0.55Se0.45 with Machine-Learning-Assisted Spectral Deconvolution.” The dataset includes a raw grid spectroscopy file acquired on FeTe0.55Se0.45 at 40 mK under magnetic field, together with Python/Jupytext analysis scripts used for STM/S data processing, visualization, spectral deconvolution, Lorentzian peak fitting, feature extraction, machine-learning-assisted clustering, and figure generation. These files support the analysis of vortex-core local density of states and the identification of zero-bias-peak-related spectral components from complex in-gap states. The dataset is intended to provide a citable archival record of the data and analysis code associated with the published manuscript and to support transparency and reproducibility of the reported STM/S and machine-learning workflow.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Super-resolution computational saturated absorption microscopy

Imaging beyond the diffraction limit barrier has attracted wide attention due to the ability to resolve previously hidden image features. Of the various super-resolution microscopy techniques available, a particularly simple method called saturated excitation microscopy (SAX) requires only simple modification of a laser scanning microscope: The illumination beam power is sinusoidally modulated and driven into saturation. SAX images are extracted from the harmonics of the modulation frequency and exhibit improved spatial resolution. Unfortunately, this elegant strategy is hindered by the incursion of shot noise that prevents high-resolution imaging in many realistic scenarios. Here, we demonstrate a technique for super-resolution imaging that we call computational saturated absorption (CSA) in which a joint deconvolution is applied to a set of images with diversity in spatial frequency support among the point spread functions (PSFs) used in the image formation with saturated laser scanning fluorescence microscopy. CSA microscopy allows access to the high spatial frequency diversity in a set of saturated effective PSFs, while avoiding image degradation from shot noise.

Murray, Gabe (ORCID:0000000295655485)↗

Universal dwell time optimization for deterministic optics fabrication

Computer-Controlled Optical Surfacing (CCOS) has been greatly developed and widely used for precision optical fabrication in the past three decades. It relies on robust dwell time solutions to determine how long the polishing tools must dwell at certain points over the surfaces to achieve the expected forms. However, as dwell time calculations are modeled as ill-posed deconvolution, it is always non-trivial to reach a reliable solution that 1) is non-negative, since CCOS systems are not capable of adding materials, 2) minimizes the residual in the clear aperture 3) minimizes the total dwell time to guarantee the stability and efficiency of CCOS processes, 4) can be flexibly adapted to different tool paths, 5) the parameter tuning of the algorithm is simple, and 6) the computational cost is reasonable. In this study, we propose a novel Universal Dwell time Optimization (UDO) model that universally satisfies these criteria. First, the matrix-based discretization of the convolutional polishing model is employed so that dwell time can be flexibly calculated for arbitrary dwell points. Second, UDO simplifies the inverse deconvolution as a forward scalar optimization for the first time, which drastically increases the solution stability and the computational efficiency. Finally, the dwell time solution is improved by a robust iterative refinement and a total dwell time reduction scheme. The superiority and general applicability of the proposed algorithm are verified on the simulations of different CCOS processes. A real application of UDO in improving a synchrotron X-ray mirror using Ion Beam Figuring (IBF) is then demonstrated. The simulation indicates that the estimated residual in the 92.3 mm × 15.7 mm CA can be reduced from 6.32 nm Root Mean Square (RMS) to 0.20 nm RMS in 3.37 min. After one IBF process, the measured residual in the CA converges to 0.19 nm RMS, which coincides with the simulation.

36 MATERIALS SCIENCE↗

Generalized Uncertainty Quantification for Linear Inverse Problems in X-ray Imaging

In industrial and engineering applications, X-ray radiography has attained wide use as a data collection protocol for the assessment of material properties in cases where direct observation is not possible. The direct measurement of nuclear materials, particularly when they are under explosive or implosive loading, is not feasible, and radiography can serve as a useful tool for obtaining indirect measurements. In such experiments, high energy X-rays are pulsed through a scene containing material of interest, and a detector records a radiograph by measuring the radiation that is not attenuated in the scene. One approach to the analysis of these radiographs is to model the imaging system as an operator that acts upon the object being imaged to produce a radiograph. In this model, the goal is to solve an inverse problem to reconstruct the values of interest in the object, which are typically material properties such as density or areal density. The primary objective in this work is to provide quantitative solutions with uncertainty estimates for three separate applications in X-ray radiography: deconvolution, Abel inversion, and radiation spot shape reconstruction. For each problem, we introduce a new hierarchical Bayesian model for determining a posterior distribution on the unknowns and develop efficient Markov chain Monte Carlo (MCMC) methods for sampling from the posterior. A Poisson likelihood, based on a noise model for photon counts at the detector, is combined with a prior tailored to each application: an edge-localizing prior for deconvolution; a smoothing prior with non-negativity constraints for spot reconstruction; and a full covariance sampling prior based on a Wishart hyperprior for Abel inversion. After developing our methods in a general setting, we demonstrate each model on both synthetically generated datasets, including those from a well known radiation transport code, and real high energy radiographs taken at two U. S. Department of Energy laboratories.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Developing Accelerated Test Protocols and Tuning Microstructures of the Common Materials to Improve Robustness, Reliability, and Endurance of SOFC Cells

This work is built on our prior work where we found that phase transformation in praseodymium nickelates, e.g. Pr 2 NiO 4 (PNO) and (Pr 1-x Nd x ) 2 NiO 4 (PNNO), can be electrochemically driven, and is substantially faster when compared to thermal annealing studies. The first task aims at an attempt to further accelerate the phase transformation in the oxygen electrode by alternating the current input in the cells, which lead to the development of accelerated test protocols (ATPs). ATPs showed up to 60x faster phase transformation and up to 10x faster performance degradation in (Pr 0.50 Nd 0.50 ) 2 NiO 4 electrodes, when compared to long-term operation under constant current density. Furthermore, the phase stable Nd 2 NiO 4 and (La 0.6 Sr 0.4 )(Co 0.8 Fe 0.2 )O 3 (LSCF6482) electrodes were tested in full cells under ATPs, and showed up to 10x faster performance degradation within 1,100 hours in a comparison with long-term thermal annealing studies and electrochemical operation under constant current density. The second task aims at the quantification of the contributions of cell components to the total impedance of a solid oxide fuel cell (SOFC) using electrochemical impedance spectroscopy (EIS) and distribution of relaxation times (DRT). Specifically, the role of gas composition at both anode and cathode was systematically studied, aiming at deconvoluting, identifying and quantifying the contributions of different electrode processes. This was achieved by first tuning the partial pressure of H 2 at the anode and subsequently varying the partial pressure of O 2 at the cathode. The results suggest that, while DRT offers a viable way of deconvoluting different times distributions, additional attention is needed before assigning a peak to a specific electrode process due to the significant overlap of the contributions from the cathode and the anode. Density function theory studies show that both Pr-vacancies and O-defects play a key role on the activity and stability for nickelates towards oxygen reduction reaction. The resident O-interstitials and oxygen ions in the PrO layer form peroxide (O 2 2- ) nearby Pr vacancies. The O 2 2- limits oxygen-ion transport due to the required additional energy to break its O-O bond. We further calculated the formation and segregation energies for different Ln ions (La, Pr, Nd, Pm, Sm, Gd, Tb, Dy, and Ho) in PNO and CeO 2 (111) surfaces. In addition to Nd, Pm and La are suggested as potential dopants in PNO to enhance it stability without decomposition due to their more negative formation energies, lower diffusion energies, and positive separation energies.

01 COAL, LIGNITE, AND PEAT↗

Temporal Explosion Source Processes of Declared Nuclear Tests in the Democratic People’s Republic of Korea

In this work we highlight a preliminary temporal source analysis of the six declared Democratic People's Republic of Korea (DPRK) nuclear tests. We use regional seismic data to estimate relative source time functions (RSTFs) via iterative time-domain deconvolution (Ammon, 2006; Pippin, 2022) of vertical-component ground motions recorded within 2000 km of the source region. Since RSTFs are ideally independent of site and propagation effects, their amplitude spectrum is equivalent to the source spectral ratio, but they also retain phase information. We compare observed RSTFs (in the time and frequency domains) with synthetic RSTFs derived from the Mueller & Murphy (1971) explosion source model. The resolution of these time functions varies, however, we generally obtain high-quality results within the limitations of the recording broadband instrumentation. The results indicate that this method effectively preserves source time-history information that can be used for temporal analysis of remote nuclear explosions. This preliminary analysis is intended to assess the viability of using time-domain deconvolution methods for extracting temporal source information.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Super Resolving Unrolled Neural Networks for Remote Sensing

In remote sensing systems, the capabilities of the system are constrained by the complex interactions between size, weight, and power (SWAP) of potential designs. In electro-optical (EO) systems, examples of these critical parameters include the system’s sensitivity and resolution. Those parameters can be increased by ever larger optical apertures and focal planes but at the cost of more SWAP. Multi-image super resolution (MISR) techniques allow resolution to be enhanced via computation rather than more sophisticated optical hardware. These algorithms combine multiple images together into a single, higher resolution image, trading temporal resolution and computation for spatial resolution. Fielded MISR techniques, such as Drizzle, can require several hundred images to create a single super resolved image, implying reduced temporal resolution, increased data acquisition load, and limiting mission applications. Iterative techniques, such as model-based image reconstruction and compressive sensing, have been shown to create super resolved images using fewer images than Drizzle. They do this by posing an optimization problem that balances accuracy between a highly accurate physical model and an image model. In the case of super resolution, the physical model is defined by the relation between low resolution input images and the desired high resolution output image. The image model encodes some assumptions about the super resolved image. These assumptions are meant to suppress reconstruction artifacts that arise due to deterministic physical model error, stochastic measurement noise, and potential undersampling. In practice, the performance of iterative methods are limited by imaging models compatible with optimization. Deep learning-based methods can effectively learn image models of arbitrary complexity, but lack the theoretical explainability and robustness of iterative techniques. Consensus equilibrium (CE) generalizes the iterative techniques beyond optimization, enabling blackbox algorithms such as traditional and neural image denoisers to be used as the image model. CE-based approaches retain much of the explainability and robustness of iterative techniques while allowing the expressiveness of machine learning image models to be used. Additionally, by unrolling iterations of CE with an embedded image denoiser, the image denoiser can be further trained and specialized to the specific application with potentially higher quality reconstructions. Under this project, we demonstrated the feasibility of training an unrolled neural network based upon CE. While we didn’t train one, we showed that the CE process is differentiable and its gradient can be tractably computed. We also explored the usage of a variants of CE akin to generative neural works. Most importantly, we applied the CE framework to a number of problems including non-blind deconvolution, upsampling, single-image super resolution, MISR, event-based sensing, and saturated deconvolution. Our MISR prototype creates high quality reconstructions with an order of magnitude fewer images than previous approaches and, critically, produces these reconstructions fast enough for practical usage.

47 OTHER INSTRUMENTATION↗

X-RAYING THE DARK SIDE OF VENUS—SCATTER FROM VENUS’ MAGNETOTAIL?

We analyze significant X-ray, EUV, and UV emission coming from the dark side of Venus observed with Hinode /XRT and Solar Dynamics Observatory /Atmospheric Imaging Assembly ( SDO /AIA) during a transit across the solar disk that occurred in 2012. As a check we have analyzed an analogous Mercury transit that occurred in 2006. We have used the latest version of the Hinode /XRT point spread function to deconvolve Venus and Mercury X-ray images, to remove instrumental scattering. After deconvolution, the flux from Venus’ shadow remains significant while that of Mercury becomes negligible. Since stray light contamination affects the XRT Ti-poly filter data we use, we performed the same analysis with XRT Al-mesh filter data, not affected by the light leak. Even the latter data show residual flux. We have also found significant EUV (304 Å, 193 Å, 335 Å) and UV (1700 Å) flux in Venus’ shadow, measured with SDO /AIA. The EUV emission from Venus’ dark side is reduced, but still significant, when deconvolution is applied. The light curves of the average flux of the shadow in the X-ray, EUV, and UV bands appear different as Venus crosses the solar disk, but in any of them the flux is, at any time, approximately proportional to the average flux in a ring surrounding Venus, and therefore proportional to that of the solar regions around Venus’ obscuring disk line of sight. The proportionality factor depends on the band. This phenomenon has no clear origin; we suggest that it may be due to scatter occurring in the very long magnetotail of Venus.

79 ASTRONOMY AND ASTROPHYSICS↗

SUPERMASSIVE BLACK HOLES WITH HIGH ACCRETION RATES IN ACTIVE GALACTIC NUCLEI. VI. VELOCITY-RESOLVED REVERBERATION MAPPING OF THE Hβ LINE

In the sixth of a series of papers reporting on a large reverberation mapping (RM) campaign of active galactic nuclei (AGNs) with high accretion rates, we present velocity-resolved time lags of Hβ emission lines for nine objects observed in the campaign during 2012–2013. In order to correct the line broadening caused by seeing and instruments before analyzing the velocity-resolved RM, we adopt the Richardson–Lucy deconvolution to reconstruct their Hβ profiles. The validity and effectiveness of the deconvolution are checked using Monte Carlo simulation. Five among the nine objects show clear dependence of the time delay on velocity. Mrk 335 and Mrk 486 show signatures of gas inflow whereas the clouds in the broad-line regions (BLRs) of Mrk 142 and MCG +06-26-012 tend to be radial outflowing. Mrk 1044 is consistent with having virialized motions. The lags of the remaining four are not velocity-resolvable. The velocity-resolved RM of super-Eddington accreting massive black holes (SEAMBHs) shows that they have diverse kinematics in their BLRs. Comparing with the AGNs with sub-Eddington accretion rates, we do not find significant differences in the BLR kinematics of SEAMBHs.

79 ASTRONOMY AND ASTROPHYSICS↗

EmpiriciSN: Re-sampling Observed Supernova/Host Galaxy Populations Using an XD Gaussian Mixture Model

We describe two new open-source tools written in Python for performing extreme deconvolution Gaussian mixture modeling (XDGMM) and using a conditioned model to re-sample observed supernova and host galaxy populations. XDGMM is new program that uses Gaussian mixtures to perform density estimation of noisy data using extreme deconvolution (XD) algorithms. Additionally, it has functionality not available in other XD tools. It allows the user to select between the AstroML and Bovy et al. fitting methods and is compatible with scikit-learn machine learning algorithms. Most crucially, it allows the user to condition a model based on the known values of a subset of parameters. This gives the user the ability to produce a tool that can predict unknown parameters based on a model that is conditioned on known values of other parameters. EmpiriciSN is an exemplary application of this functionality, which can be used to fit an XDGMM model to observed supernova/host data sets and predict likely supernova parameters using a model conditioned on observed host properties. It is primarily intended to simulate realistic supernovae for LSST data simulations based on empirical galaxy properties.

79 ASTRONOMY AND ASTROPHYSICS↗