Search NASA⌕ Search

SEARCH · Search NASA

Results for “delay line”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A new calibration method for time delay standard and its application

A method which is used to measure time delay accurately by using a Type 900-LB slotted line is described. The accuracy for calibrating time delay of a precision coaxial air line Type 900-L is about + or - (0.4 to 0.6)ps, and for coaxial cables with VSWR less than 1.5 and time delay t less than 50ns is about + or - (3 to 5)ps. Theoretical analysis and mathematical derivation of microwave networks in cascade are given. Methods to eliminate the errors which are caused by the discontinuities and the error analysis of the measuring system are presented. Skin effect analysis of the transient characteristic of coaxial transmission line are discussed in detail. Methods to eliminate the errors which result from using the calibrated time delay standard to calibrate time interval measurement instruments are presented. The estimation of errors and formulae for correction of those errors are described.

Su, B. W.↗

Stabilizing Fiber-Optic Transmission Lines

Voltage-controlled optical phase shifter is key. Optical phase shifter stabilizes propagation delay of fiber-optic transmission line by compensating for temperature and pressure effects. Applicable to phased array antenna systems and very-long-baseline interferometer distribution systems.

Lutes, G. F.↗

A new instrument for the determination of radio path delay due to atmospheric water vapor

A new water-vapor radiometer is being developed to determine atmospheric path-delay corrections for geodynamics applications. The radiometer has microwave channels at 20.7, 22.2, and 31.4 GHz, and includes new features which should promote radiometric precision while at the same time reduce instrument complexity. The instrument will be compact, portable, and will possess a self-diagnostic capability to ensure reliability. The performance objective is the determination of the line-of-sight path delay through the atmosphere due to water vapor with a one-sigma error less than 0.5 cm at the zenith.

Janssen, M. A.↗

A test of water vapor radiometer-based troposphere calibration using VLBI observations on a 21-kilometer baseline

Simultaneous very long baseline interferometry (VLBI) and water vapor radiometer (WVR) measurements on a 21 km baseline showed that calibration by WVRs removed a significant fraction of the effect of tropospheric delay fluctuations for these experiments. From comparison of the residual delay variations within scans and between scans, the total tropospheric contribution t the delay residuals for each of the three 5 to 20 hour sessions was estimated as 1, 17, and 10%, with the first value being uncertain. The observed improvement in rms residual delay from WVR calibration during these three sessions was 4, 16, and 2%, respectively. The improvement is consistent with the estimated 2 to 3 mm path delay precision of current WVRs. The VLBI measurements, of natural radio sources, were conducted in April and May 1993 at Goldstone, California. Dual-frequency (2.3 and 8.4 GHz) observations were employed to remove the effects of charged particles from the data. Measurements with co-pointed WVRs, located within 50 m of the axis of each antenna, were performed to test the ability of the WVRs to calibrate line-of-sight path delays. Factors that made WVR performance assessment difficult included (1) the fact that the level of tropospheric fluctuations was smaller than is typical for Goldstone during these experiments and (2) VLBI delay variations on longer time scales (i.e., over multiple scans) contained uncalibrated instrumental effects (probably a result of slow temperature variations in the VLBI hardware) that were larger than the tropospheric effects.

Linfield, R. P.↗

Observational Model for Precision Astrometry with the Space Interferometry Mission

The Space Interferometry Mission (SIM) is a space-based 10-m baseline Michelson optical interferometer operating in the visible waveband that is designed to achieve astrometric accuracy in the single digits of the microarcsecond domain. Over a narrow field of view SIM is expected to achieve a mission accuracy of 1 microarcsecond. In this mode SIM will search for planetary companions to nearby stars by detecting the astrometric "wobble" relative to a nearby reference star. In its wide-angle mode, SIM will provide 4 microarcsecond precision absolute position measurements of stars, with parallaxes to comparable accuracy, at the end of its 5-year mission. The expected proper motion accuracy is around 3 microarcsecond/year, corresponding to a transverse velocity of 10 m/ s at a distance of 1 kpc. The basic astrometric observable of the SIM instrument is the pathlength delay. This measurement is made by a combination of internal metrology measurements that determine the distance the starlight travels through the two arms of the interferometer, and a measurement of the white light stellar fringe to find the point of equal pathlength. Because this operation requires a non-negligible integration time, the interferometer baseline vector is not stationary over this time period, as its absolute length and orientation are time varying. This paper addresses how the time varying baseline can be "regularized" so that it may act as a single baseline vector for multiple stars, as required for the solution of the astrometric equations.

TILE OBSERVATIONS↗

Evidence for Supermassive Black Holes in Active Galactic Nuclei from Emission-Line Reverberation

Emission-line variability data for Seyfert 1 galaxies provide strong evidence for the existence of supermassive black holes in the nuclei of these galaxies and that the line-emitting gas is moving in the gravitational potential of that black hole. The time-delayed response of the emission lines to continuum variations is used to infer the size of the line-emitting region, which is then combined with measurements of the Doppler widths of the variable line components to estimate a virial mass. la the case of the best-studied galaxy, NGC 5548, various emission lines spanning an order of magnitude in distance from the central source show the expected V proportional to r(sup -l/2) correlation between distance and line width and are thus consistent with a single value for the mass. Two other Seyfert galaxies, NGC 7469 and 3C 390.3, show a similar relationship. We compute the ratio of luminosity to mass for these three objects and the narrow-line Seyfert I galaxy NGC 4051 and find that the gravitational force on the line-emitting gas is much stronger than radiation pressure. These results strongly support the paradigm of gravitationally bound broad emission line region clouds.

Peterson, Bradley M.↗

Observations with the SMM gamma-ray spectrometer - The impulsive solar flares of 1980 March 29

Gamma-ray continuum emission from 0.3 to 1 MeV was observed with the gamma-ray spectrometer on the Solar Maximum Mission satellite during two impulsive solar flares on 1980 March 29, from active region 2363 at 0918 UT and from active region 2357 at 0955 UT. Evidence is presented for a hardening of the spectrum during the impulsive phase of the flares. The photon intensity greater than 100 keV appears to decay at a slower rate than that at lower energies. Time-integrated photon spectra for both flares are incompatible with a single-temperature thermal-bremsstrahlung model. Upper limits for prompt and delayed gamma-ray lines are presented.

Ryan, J. M.↗

X-ray and gamma-ray observations of a white-light flare

Hard radiations (X-ray and gamma-ray) from a major solar flare observed by HEAO-1 on July 11, 1978, are discussed. It is noted that the observations showed gamma-ray line and continuum emission extending to the highest energy observed. The lines are identified with the 2.2 MeV line of deuterium formation and the 4.4 MeV line of inelastic scattering on C-12, both of which were previously observed in the flares of August 1972. The flare of July 11 is identified as a white-light flare. It therefore provides the first opportunity for a detailed examination of white-light flare theories that depend on proton heating of the photosphere. The line strength over a four-minute integration at 2.2 MeV is found to be 1.00 + or - 0.29 ph/sq cm-sec; the gamma-ray emission (excluding the 2.2 MeV line which was appreciably delayed) lagged by less than 20 sec approximately after the hard X-ray and microwave fluxes. It is concluded that the 'second-stage' acceleration of high-energy solar particles must commence promptly after the impulsive phase.

Hudson, H. S.↗

Inversion Algorithms for Water Vapor Radiometers Operating at 20.7 and 31.4 Ghz

Eight water vapor radiometers (WVRs) were constructed as research and development tools to support the Advanced System Programs in the Deep Space Network and the Crustal Dynamics Project. These instruments are intended to operate at the stations of the Deep Space Network (DSN), various radio observatories, and obile facilities that participate in very long baseline interferometric (VLBI) experiments. It is expected that the WVRs will operate in a wide range of meteorological conditions. Several algorithms are discussed that are used to estimate the line-of-sight path delay due to water vapor and columnar liquid water rom the observed microwave brightness temperatures provided by the WVRs. In particular, systematic effects due to site and seasonal variations are examined. The accuracy of the estimation as indicated by a simulation calculation is approximately 0.3 cm for a noiseless WVR in clear and moderately cloudy weather. With a realistic noise model of WVR behavior, the inversion accuracy is approximately 0.6 cm.

Resch, G. M.↗

The effect of tropospheric fluctuations on the accuracy of water vapor radiometry

Line-of-sight path delay calibration accuracies of 1 mm are needed to improve both angular and Doppler tracking capabilities. Fluctuations in the refractivity of tropospheric water vapor limit the present accuracies to about 1 nrad for the angular position and to a delay rate of 3x10(exp -13) sec/sec over a 100-sec time interval for Doppler tracking. This article describes progress in evaluating the limitations of the technique of water vapor radiometry at the 1-mm level. The two effects evaluated here are: (1) errors arising from tip-curve calibration of WVR's in the presence of tropospheric fluctuations and (2) errors due to the use of nonzero beamwidths for water vapor radiometer (WVR) horns. The error caused by tropospheric water vapor fluctuations during instrument calibration from a single tip curve is 0.26 percent in the estimated gain for a tip-curve duration of several minutes or less. This gain error causes a 3-mm bias and a 1-mm scale factor error in the estimated path delay at a 10-deg elevation per 1 g/cm(sup 2) of zenith water vapor column density present in the troposphere during the astrometric observation. The error caused by WVR beam averaging of tropospheric fluctuations is 3 mm at a 10-deg elevation per 1 g/cm(sup 2) of zenith water vapor (and is proportionally higher for higher water vapor content) for current WVR beamwidths (full width at half maximum of approximately 6 deg). This is a stochastic error (which cannot be calibrated) and which can be reduced to about half of its instantaneous value by time averaging the radio signal over several minutes. The results presented here suggest two improvements to WVR design: first, the gain of the instruments should be stabilized to 4 parts in 10(exp 4) over a calibration period lasting 5 hours, and second, the WVR antenna beamwidth should be reduced to about 0.2 deg. This will reduce the error induced by water vapor fluctuations in the estimated path delays to less than 1 mm for the elevation range from zenith to 6 deg for most observation weather conditions.

Wilcox, J. Z.↗

Seoul National University AGN Monitoring Project. I. Strategy and Sample

While the reverberation mapping technique is the best available method for measuring black hole mass in active galactic nuclei (AGNs) beyond the local volume, this method has been mainly applied to relatively low-to-moderate luminosity AGNs at low redshift. We present the strategy of the Seoul National University AGN Monitoring Project, which aims at measuring the time delay of the H line emission with respect to AGN continuum, using a sample of relatively high luminosity AGNs out to redshift z ∼ 0.5. We present simulated cross correlation results based on a number of mock light curves, in order to optimally determine monitoring duration and cadence. We describe our campaign strategy based on the simulation results and the availability of observing facilities. We present the sample selection, and the properties of the selected 100 AGNs, including the optical luminosity, expected time lag, black hole mass, and Eddington ratio.

Jong-Hak Woo↗

Hydroxyl Tagging Velocimetry Demonstration in an Augmented Spark Igniter

Hydroxyl tagging velocimetry (HTV) involves tagging a flow by “writing” a line of OH molecules using a laser beam to dissociate H2O molecules and capturing an image of the line after a short delay using laser-induced fluorescence. Velocity is obtained by a time-of-flight analysis of the data. In this effort, HTV was used for obtaining both instantaneous and average velocity profiles in the flow of an augmented spark igniter. Two modes of camera readout were investigated, called conventional full frame mode and dual image mode feature (DIF) mode. In DIF mode, two images are captured in quick succession and therefore the measurement is immune to vibration effects. Measurement uncertainty for the DIF case varied from 3% at the centerline to 10% at the edges of the profile in a 1000-m/s flow. For the full-frame case, measurement uncertainty varied from 3% at the centerline to 7% at the edges. This demonstration provides evidence that the HTV technique is well suited for obtaining velocity profiles in the challenging environment of either a rocket engine or rocket engine igniter.

Augmented Spark Igniter↗

Comparison of MGII and CIV emission lines in NGC5548

Results are presented of a cross-correlation analysis in which the Seyfert galaxy NGC 5548 was monitored in the UV portion of its spectrum every 4 d for an 8-mo period by an international collaborative effort using the IUE satellite. The analysis shows that the CIV 1550-A line correlates with the underlying continuum with a time delay of about 10 d. A similar analysis for the MgII 2798-A line yields a much broader peak and a delay of about 50 +/- 20 d. Thus the MgII line emitting gas appears to be about 5 times more distant from the central source. The MgII and CIV profiles in this series of spectra are compared on the same velocity scale. The two lines are quite similar on the red side of the profile, with the CIV more extended on the blue side. The overall width of the CIV is as much as 40 percent larger, but it is definitely not larger by a factor or two or more. It is concluded that the motion of the broad line emitting gas is not dominated by the gravitational influence of a central massive object.

Ptak, R.↗

Wind and Temperature Consensus at Horn Point, HU-Beltsville, Piney Run (Maryland) in support of CoURAGE

The Maryland Department of the Environment (MDE) operates a ground-based atmospheric profiling network consisting of collocated radar wind profilers (RWP) and radio acoustic sounding systems (RASS) as part of its Ambient Air Monitoring Program. This network provides continuous observations of wind and temperature structure in the lower troposphere to support air quality forecasting, regulatory analysis, and atmospheric research. The network currently includes three fixed sites across Maryland: Horn Point (HP, lower eastern shore) [38.587525°,-76.141006°], Howard University-Beltsville (HUB, central Maryland) [39.055277°, -76.878632°], and Piney Run (PR, western Maryland) [39.705950°, -79.012000°] The network is designed to capture regional variability in atmospheric transport and boundary-layer processes. These systems measure vertical profiles of horizontal wind speed and direction using Doppler radar techniques, with observations typically spanning from ~100 m above ground level up to approximately 2.5–4 km. Measurements are derived from the Doppler shift of backscattered electromagnetic signals, enabling retrieval of wind vectors at multiple altitudes with high temporal resolution (e.g., 30-minute averages reported every 6 minutes). Each radar wind profiler is paired with a Radio Acoustic Sounding System (RASS) to provide profiles of virtual temperature in the lower atmosphere (~100–200 m AGL) by measuring the propagation speed of acoustic waves. Together, the RWP/RASS system yields a coupled data set of thermodynamic and kinematic atmospheric structure, including additional parameters such as vertical velocity, radial velocity, signal-to-noise ratio, and spectral width for advanced analysis. There are two types of files for each station: wind data (files with a "w" prefix) and virtual temperature RASS data (files with a "t" prefix). The wind data files are in the format wYYDDD.cns, where YY is the 2-digit year and DDD is the day of the year. The RASS virtual temperature data files are in the format tYYDDD.cns. Each record has the following header structure: Line 1 : Station Name RASS files Line 2 : RASS rev DeTect_2.0, WINDS files Line 2 : WINDS rev ATI 5.1 Line 3 : N latitude, W longitude, and site elevation (m) Line 4 : Date and begin time of consensus: yy mm dd hh mn ss plus # minutes to add to get UTC Line 5 : Consensus averaging time (minutes); number of beams; number of range gates Line 6 : Number of records required to make consensus (num) total number of records (tot) and the consensus window size (m/s) in the format: num:tot (window) RASS files Line 7 : no. of coded cells, no. of spec, pulse width (ns), and inter-pulse period (µs), WINDS files Line 7 : No. of coded cells, no. of spectra, pulse width (ns), and inter-pulse period (µs), each with a pair of values: first value is for oblique beams, second for vertical RASS files Line 8 : Full scale Doppler value (m/s) Delay to first gate (ns) Number of gates Spacing of gates (ns), WINDS files Line 8 : Full scale Doppler velocity (m/s), oblique and vertical Vertical correction applied to oblique beams? (0 = no, 1 = yes) Delay to first gate (ns), oblique and vertical Number of gates, oblique and vertical Spacing of gates (ns), oblique and vertical Line 9 : Azimuth and elevation (9s indicate vertical beam not used) RASS files Line 10, values : HT = Height above ground (km), T = Uncorrected virtual temperature consensus (deg C), Tc = Corrected virtual temperature consensus (deg C), W = Vertical wind consensus (9s indicate vertical beam not used, w-component, positive upward, m/s), CNT = Number of records that made consensus (for the 3 values in same order), SNR = Average signal to noise ratio (dB) of records in consensus (same order) WINDS files Line 10, values : HT = Height above ground (km), SPD = Wind speed (m/s), DIR = Wind direction (deg E of N from N), RAD = Radial velocities for each beam (m/s) in order given in azimuth and elevation line (positive toward radar; 9s indicate vertical beam not used, CNT = Number of records that made consensus, SNR = Average signal to noise ratio (dB) of records in consensus

{"wind speed and direction",temperature}↗

TOPEX/POSEIDON microwave radiometer performance and in-flight calibration

Results of the in-flight calibration and performance evaluation campaign for the TOPEX/POSEIDON microwave radiometer (TMR) are presented. Intercomparisons are made between TMR and various sources of ground truth, including ground-based microwave water vapor radiometers, radiosondes, global climatological models, special sensor microwave imager data over the Amazon rain forest, and models of clear, calm, subpolar ocean regions. After correction for preflight errors in the processing of thermal/vacuum data, relative channel offsets in the open ocean TMR brightness temperatures were noted at the approximately = 1 K level for the three TMR frequencies. Larger absolute offsets of 6-9 K over the rain forest indicated a approximately = 5% gain error in the three channel calibrations. This was corrected by adjusting the antenna pattern correction (APC) algorithm. AS 10% scale error in the TMR path delay estimates, relative to coincident radiosondes, was corrected in part by the APC adjustment and in part by a 5% modification to the value assumed for the 22.235 FGHz water vapor line strength in the path delay retrieval algorithm. After all in-flight corrections to the calibration, TMR global retrieval accuracy for the wet tropospheric range correction is estimated at 1.1 cm root mean square (RMS) with consistent peformance under clear, cloudy, and windy conditions.

Ruf, C. S.↗

Echo Mapping of Active Galactic Nuclei

Echo mapping makes use of the intrinsic variability of the continuum source in active galactic nuclei to map out the distribution and kinematics of line-emitting gas from its light travel time-delayed response to continuum changes. Echo mapping experiments have yielded sizes for the broad line-emitting region in about three dozen AGNs. The dynamics of the line-emitting gas seem to be dominated by the gravity of the central black hole, enabling measurement of the black-hole masses in AGNs. We discuss requirements for future echo-mapping experiments that will yield the high quality velocity-delay maps of the broad-line region that are needed to determine its physical nature.

Peterson, B. M.↗

Ionosphere Delay Calibration and Calibration Errors for Satellite Navigation of Aircraft

The Federal Aviation Administration (FAA) is implementing a satellite-based navigation system for aircraft using the Global Positioning System (GPS). Positioning accuracy of a few meters will be achieved by broadcasting corrections to the direct GPS signal. These corrections are derived using the wide-area augmentation system (WAAS), which includes a ground network of at least 24 GPS receivers across the Continental US (CONUS). WAAS will provide real-time total electron content (TEC) measurements that can be mapped to fixed grid points using a real-time mapping algorithm. These TECs will be converted into vertical delay corrections for the GPS L1 frequency and broadcast to users every five minutes via geosynchronous satellite. Users will convert these delays to slant calibrations along their own lines-of-sight (LOS) to GPS satellites. Uncertainties in the delay calibrations will also be broadcast, allowing users to estimate the uncertainty of their position. To maintain user safety without reverting to excessive safety margins an empirical model of user calibration errors has been developed. WAAS performance depends on factors that include geographic location (errors increase near WAAS borders), and ionospheric conditions, such as the enhanced spatial electron density gradients found during ionospheric storms.

Harris, Ian↗

Characterization of Treefoil Peptide Genes in Iron-Ion or X-Irradiated Human Cells

The gastrointestinal (GI) tract is especially sensitive to ionizing radiation, probably because of its high rate of cell turn over. Most of the data in the literature concerns the histological/anatomical description of damage rather than functional studies. In fact, previous reports in humans have shown that, at doses of 2 Gy or more, functional abnormalities appear indicating that in radiation sensitive tissues the effects of radiation are not limited to cell death. GI functions are controlled in particular by GI peptides. One hypothesis is that ionizing radiation may modulate the synthesis and release of these peptides and consequently may contribute largely to abnormalities in GI function. However, no previous studies have been concerned with GI-specific gene expression in irradiated GI tissues. The family of human trefoil peptides comprises three members thus far, all of which are expressed in specific regions of the GI tract. In addition, two trefoil peptides, pS2 (TFFI) and HITF (TFF2) are expressed in breast tissue. Their exact function in GI and breast tissues is unclear but mucosal integrity, repair, mucin secretion and responsiveness to hormones have been shown. We recently isolated and characterized pS2 as a novel p53- and estrogen receptor-independent gene whose MRNA expression in several cells lines was found to be delayed 4 to 7 days after irradiation with X-rays, fission neutrons or 1 GeV/n Fe-ions. The aim of the present study was to determine whether pS2 and HITF have a similar induction kinetics in irradiated gastric and breast cell lines, and whether they have the phorbol ester (TPA) responsive element (TRE).

Balcer-Kubiczek, E. K.↗