Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector R&D”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Quantum Well Infrared Photodetector Research and Development at Jet Propulsion Laboratory

In this paper we discuss the optimization of the detector design, material growth and processing that has culminated in realization of 15 micron cutoff 128 x 128 QWIP focal plane array camera, hand-held and palmize 256 x 256 long-wavelength QWIP cameras and 648 x 480 long-wavelength cameras, holding forth great promise for myriad applications in 6-25 micron wavelength range in science, medicine, defense and industry.

Quantum↗

Astronomical applications of the new Goddard Si:Bi 16 x 16 array camera system

An improved 4-18 micron array camera system has been developed at NASA Goddard Space Flight Center for astronomical protometry, using 16 x 16 Si:Bi (bismuth dope silicon) accumulation mode charge injection device (AMCID) with 256 active pixels. An astronomical observing program using this device has been carried out. The 16 x 16 device had sufficiently good sensitivity, uniformity and noise characteristics to be used for successful observations at the Steward Observatory Mt. Lemmon 60 and 61-inch telescopes in May 1983, and at the NASA Infrared Telescope Facility (IRTF) at Mauna Kea in August 1983. Initial results indicate that this detector has sensitivity and noise characteristics comparable to other devices from the same generation of Aerojet arrays.

Lamb, G.↗

Capacitor-type micrometeoroid detectors

The metal oxide semiconductor (MOS) capacitor micrometeroid detector consists of a thin dielectric capacitor fabricated on a silicon wafer. In operation, the device is charged to a voltage level sufficiently near breakdown that micrometeoroid impacts will cause dielectric deformation or heating and subsequent arc-over at the point of impact. Each detector is capable of recording multiple impacts because of the self-healing characteristics of the device. Support instrumentation requirements consist of a voltage source and pulse counters that monitor the pulse of recharging current following every impact. An investigation has been conducted in which 0.5 to 5 micron diameter carbonized iron spheres traveling at velocities of 4 to 10 Km/sec were impacted on to detectors with either a dielectric thickness of 0.4 or 1.0 micron. This study demonstrated that an ion microprobe tuned to sufficiently high resolution can detect Fe remaining on the detector after the impact. Furthermore, it is also possible to resolve Fe ion images free of mass interferences from Si, for example, giving its spatial distribution after impact. Specifically this technique has shown that significant amounts of impacting particles remain in the crater and near it which can be analyzed for isotopic content. Further testing and calibration could lead to quantitive analysis. This study has shown that the capacitor type micrometeroid detector is capable of not only time and flux measurements but can also be used for isotopic analysis.

Wortman, J. J.↗

Diagnostic and quality-assurance tools for low-contrast images obtained from array detectors

We investigate methods of estimating a background image frame for subtraction from a data frame for use when a more suitable measured background frame is not available. We define background as any signal component that is not attributable to the phenomenon currently under investigation. We describe a technique that is based on pixel-by-pixel least-squares regression of images for computing a background frame from available data. We argue that the same technique can be a useful quality-assurance tool for evaluating instrument performance. For example, it can help to separate image structure resulting from the reading process from structure resulting from the characteristics of the detector itself. We demonstrate that background estimation can be nontrivial by comparing the results of different background estimation procedures by using data obtained from a CCD array detector. We investigate the temperature-dependent contributions of the detector and readout electronics to the total signal as a demonstration of the diagnostic capabilities of least-squares image regression.

Hatfield, D. B.↗

Correlation Between Bulk Material Defects and Spectroscopic Response in Cadmium Zinc Telluride Detectors

One of the critical challenges for large area cadmium zinc telluride (CdZnTe) detector arrays is obtaining material capable of uniform imaging and spectroscopic response. Two complementary nondestructive techniques for characterizing bulk CdZnTe have been developed to identify material with a uniform response. The first technique, infrared transmission imaging, allows for rapid visualization of bulk defects. The second technique, x-ray spectral mapping, provides a map of the material spectroscopic response when it is configured as a planar detector. The two techniques have been used to develop a correlation between bulk defect type and detector performance. The correlation allows for the use of infrared imaging to rapidly develop wafer mining maps. The mining of material free of detrimental defects has the potential to dramatically increase the yield and quality of large area CdZnTe detector arrays.

Parker, Bradford H.↗

Status of the Micro-X Sounding Rocket X-Ray Spectrometer

Micro-X is a sounding rocket borne X-ray telescope that utilizes transition edge sensors to perform imaging spectroscopy with a high level of energy resolution. Its 2.1m focal length X-ray optic has an effective area of 300 sq cm, a field of view of 11.8 arcmin, and a bandpass of 0.12.5 keV. The detector array has 128 pixels and an intrinsic energy resolution of 4.5 eV FWHM. The integration of the system has progressed with functional tests of the detectors and electronics complete, and performance characterization of the detectors is underway. We present an update of ongoing progress in preparation for the upcoming launch of the instrument.

X-ray astronomy↗

The Experiment for Cryogenic Large-aperture Intensity Mapping (EXCLAIM)

Submillimeter and far-IR spectroscopy provides insight into galaxy evolution through measurement of atomic and molecular line emission. The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument designed to carry out intensity mapping to measure the cumulative redshifted line emission from carbon monoxide and singly-ionized carbon to probe star formation in windows from the present to z=3.5. During this time, the rate of star formation dropped dramatically, while dark matter continued to cluster. Intensity mapping permits a blind and complete survey of emitting gas through statistics of cumulative brightness fluctuations. EXCLAIM achieves high sensitivity using a cryogenic telescope coupled to six integrated spectrometers with spectral resolving power R=512 and employing microwave kinetic inductance detectors. Here we summarize the status of the mission.

Maryam Rahmani↗

The Experiment for Cryogenic Large-aperture Intensity Mapping (EXCLAIM)

Submillimeter and far-IR spectroscopy provides insight into galaxy evolution through atomic and molecular line emission. The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a cryogenic balloon-borne instrument designed to carry out an intensity mapping to measure the cumulative redshifted line emission from carbon monoxide and singly-ionized carbon to probe star formation in windows from the present to z=3.5. During this time, the rate of star formation dropped dramatically, while dark matter continued to cluster. Intensity mapping permits a blind and complete survey of emitting gas through statistics of cumulative brightness fluctuations. EXCLAIM achieves high sensitivity using a cryogenic telescope coupled to six integrated spectrometers with spectral resolving power R = 512 and employing kinetic inductance detectors. Here we summarize the status of the mission.

Maryam Rahmani↗

Radiation detector readout system Patent

Circuit design for determining amount of photomultiplier tube light detection utilizing variable current source and dark current signals of opposite polarity

Baker, B. R.↗

A 1.2 meter balloon-borne telescope for a submillimeter wave sky survey

A balloon-borne, 1.2 meter Cassegrain telescope designed for diffraction-limited imagery at 100 microns is being developed for a survey of the Galactic plane at submillimeter wavelengths. The telescope pointing system is servocontrolled using a gyroscope for the primary stabilization reference. Extensive use is made of microprocessors for flight sequencing, pointing control and stabilization, and telemetry formatting. A description of the telescope, helium-cooled detectors, and the orientation subsystems are presented together with a brief discussion of the proposed astronomical observations.

Silverberg, R. F.↗

Shortwave infrared 512 x 2 line sensor for earth resources applications

As part of the NASA remote-sensing Multispectral Linear Array Program, an edge-buttable 512 x 2 IRCCD line image sensor with 30-micron Pd2Si Schottky-barrier detectors is developed for operation with passive cooling at 120 K in the 1.1-2.5 micron short infrared band. On-chip CCD multiplexers provide one video output for each 512 detector band. The monolithic silicon line imager performance at a 4-ms optical integration time includes a signal-to-noise ratio of 241 for irradiance of 7.2 microwatts/sq cm at 1.65 microns wavelength, a 5000 dynamic range, a modulation transfer function, greater than 60 percent at the Nyquist frequency, and an 18-milliwatt imager chip total power dissipation. Blemish-free images with three percent nonuniformity under illumination and nonlinearity of 1.25 percent are obtained. A five SWIR imager hybrid focal plane was constructed, demonstrating the feasibility of arrays with only a two-detector loss at each joint.

Tower, J. R.↗

A compact imaging spectrometer for studies of space vehicle induced environment emissions

On the basis of spectral measurements made from the Space Shuttle and on models of the possible Space Station external environment, it appears likely that, even at the planned altitudes of Space Station, photon emissions will be induced. These emissions will occur to some degree throughout the UV-visible-IR spectrum. The emissions arise from a combination of processes including gas phase collisions between relatively energetic ambient and surface emitted or re-emitted atoms or molecules, where the surface raises some species to excited energy states. At present it is not possible to model these processes or the anticipated intensity levels with accuracy, as a number of fundamental parameters needed for such calculations are still poorly known or unknown. However, it is possible that certain spectral line and band features will exceed the desired goal that contaminant emissions not exceed the natural zodiacal background. However, in the near infrared and infrared, it appears that this level will be exceeded to a significant degree. Therefore it will be necessary to monitor emission levels in the vicinity of Space Station, both in order to establish the levels and to better model the environment. In this note, we briefly describe a small spectrometer that is suitable for monitoring the spectrum from 1200A to less than or approximately 12,000A. This instrument uses focal plane array detectors to image this full spectral range simultaneously. The spectral resolution is 4 to 12A, depending on the portion of the wavelength range.

Torr, Marsha R.↗

EXOSS - A hard X-ray and soft gamma-ray astronomy mission

The Energetic X-ray Observatory on Space Station (EXOSS) is a mission concept for high-sensitivity coded-aperture sky surveys and studies of the spectral and temporal behavior of astrophysical sources from approximately 3 keV to 1 MeV. The scientific motivation for the mission and the instrument requirements, including the need for high angular resolution to resolve and identify numerous detectable sources, are summarized. Two baseline telescopes are described: one employing a 1.4-sq-m array of Xe gas imaging proportional counters to cover the 3 to 100 keV range with 1 arcmin resolution; the second using a 2.8-sq-m array of NaI/CsI imaging phoswich detectors to span the 20 keV to MeV range with 12 arcmin resolution.

Cook, W. R.↗

Progress Towards High-Sensitivity Arrays of Detectors of Sub-mm Radiation Using Superconducting Tunnel Junctions with Integrated Radio Frequency Single-Electron Transistors

For high resolution imaging and spectroscopy in the FIR and submillimeter, space observatories will demand sensitive, fast, compact, low-power detector arrays with 104 pixels and sensitivity less than 10(exp -20) W/Hz(sup 0.5). Antenna-coupled superconducting tunnel junctions with integrated rf single-electron transistor readout amplifiers have the potential for achieving this high level of sensitivity, and can take advantage of an rf multiplexing technique. The device consists of an antenna to couple radiation into a small superconducting volume and cause quasiparticle excitations, and a single-electron transistor to measure current through junctions contacting the absorber. We describe optimization of device parameters, and results on fabrication techniques for producing devices with high yield for detector arrays. We also present modeling of expected saturation power levels, antenna coupling, and rf multiplexing schemes.

Stevenson, T. R.↗

Demonstration of Time Domain Multiplexed Readout for Magnetically Coupled Calorimeters

Magnetically coupled calorimeters (MCC) have extremely high potential for x-ray applications due to the inherent high energy resolution capability and being non-dissipative. Although very high energy-resolution has been demonstrated, until now there has been no demonstration of multiplexed read-out. We report on the first realization of a time domain multiplexed (TDM) read-out. While this has many similarities with TDM of transition-edge-sensors (TES), for MGGs the energy resolution is limited by the SQUID read-out noise and requires the well established scheme to be altered in order to minimize degradation due to noise aliasing effects. In cur approach, each pixel is read out by a single first stage SQUID (SQ1) that is operated in open loop. The outputs of the SQ1 s are low-pass filtered with an array of low cross-talk inductors, then fed into a single-stage SQUID TD multiplexer. The multiplexer is addressed from room temperature and read out through a single amplifier channel. We present results achieved with a new detector platform. Noise performance is presented and compared to expectations. We have demonstrated multiplexed X-ray spectroscopy at 5.9keV with delta_FWHM=10eV. In an optimized setup, we show it is possible to multiplex 32 detectors without significantly degrading the Intrinsic detector resolution.

Porst, J.-P.↗

Gravitational Waves and Gamma-Rays from a Binary Neutron Star Merger: GW170817 and GRB 170817A

On 2017 August 17, the gravitational-wave event GW170817 was observed by the Advanced LIGO and Virgo detectors, and the gamma-ray burst (GRB) GRB170817A was observed independently by the Fermi Gamma-ray Burst Monitor, and the Anti-Coincidence Shield for the Spectrometer for the International Gamma-Ray Astrophysics Laboratory. The probability of the near-simultaneous temporal and spatial observation of GRB 170817A and GW170817 occurring by chance is 5.0 x 10(exp -8). We therefore confirm binary neutron star mergers as a progenitor of short GRBs. The association of GW170817 and GRB 170817A provides new insight into fundamental physics and the origin of short GRBs. We use the observed time delay of (+1.74 +/- 0.05) s between GRB170817A and GW170817 to: (i) constrain the difference between the speed of gravity and the speed of light to be between -3 x 10(exp-16) times the speed of light, (ii) place new bounds on the violation of Lorentz invariance, (iii) present a new test of the equivalence principle by constraining the Shapiro delay between gravitational and electromagnetic radiation. We also use the time delay to constrain the size and bulk Lorentz factor of the region emitting the gamma-rays. GRB170817A is the closest short GRB with a known distance, but is between 2 and 6 orders of magnitude less energetic than other bursts with measured redshift. A new generation of gamma-ray detectors, and subthreshold searches in existing detectors, will be essential to detect similar short bursts at greater distances. Finally, we predict a joint detection rate for the Fermi Gamma-ray Burst Monitor and the Advanced LIGO and Virgo detectors of 0.1 - 1.4 per year during the 2018--2019 observing run and 0.3 - 1.7 per year at design sensitivity.

Gravitational wave↗