Search NASA⌕ Search

SEARCH · Search NASA

Results for “detector calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Photonic Source for Binary Source Simulations

More than half of the sun-like stars are in binary systems or have companions that hinder the search for planets around them using traditional technologies. There are only 69 FGK dwarfs within ten pc that can harbor true earth analogs. Direct imaging can detect and study the habitability of those targets measuring the chemical composition of the atmosphere, and astrometry can measure the planet's mass. We use Multi-Star Wavefront Control (MSWC), a technique that removes stellar leakage from both stellar components to enable direct imaging of binary systems. Currently, there is a technology demonstration experiment of MSWC for the Roman coronagraph instrument at the High Contrast Imaging Testbeds operated at JPL. One of the challenges for this experiment is to produce a binary source where both stars are incoherent with each other at close physical separation. On the other hand, to measure masses, it is possible to obtain relative astrometry measurements between the binary. The TOLIMAN concept proposes to use a diffractive pupil to calibrate the distortion and detector effects to reach 1uas astrometric accuracy. JPL currently has a laboratory to demonstrate this technology, which faces the same challenge as the MSWC project of producing two incoherent nearby sources. We developed Photonic Chips with multiple waveguides in Silicon Nitride for both projects to create incoherent single sources as close as 15um. In this paper, we present the concept application, the chips design, and the first results.

photonic chips↗

Technical issues in focal plane development for terrestrial resource observations

Performance goals for solid-state detector arrays operating in the pushbroom scan mode for the high-resolution, high-accuracy remote sensing of earth resources from space are discussed and some of the focal plane and system trades involved are identified. Issues in the development of solid-state pushbroom arrays with radiometric calibration to 0.5% precision detector-to-detector over a dynamic range of 1000:1 are considered, with calibration, temporal stability and spectral response conditions noted. Factors influencing the geometric precision of satellite-borne pushbroom scan mode sensors are then examined, including satellite orbit track and attitude errors, and geometric and radiometric correlation between information in the various spectral bands. Approaches to the alignment of linear arrays of thousands of detectors are then discussed that take into account tradeoffs between fabrication and test complexity and ground processing requirements. Continuing science experiments are indicated as necessary to establish tolerances on performance goals.

Thompson, L. L.↗

Detectors for the James Webb Space Telescope Near-Infrared Spectrograph I: Readout Mode, Noise Model, and Calibration Considerations

We describe how the James Webb Space Telescope (JWST) Near-Infrared Spectrograph's (NIRSpec's) detectors will be read out, and present a model of how noise scales with the number of multiple non-destructive reads sampling-up-the-ramp. We believe that this noise model, which is validated using real and simulated test data, is applicable to most astronomical near-infrared instruments. We describe some non-ideal behaviors that have been observed in engineering grade NIRSpec detectors, and demonstrate that they are unlikely to affect NIRSpec sensitivity, operations, or calibration. These include a HAWAII-2RG reset anomaly and random telegraph noise (RTN). Using real test data, we show that the reset anomaly is: (1) very nearly noiseless and (2) can be easily calibrated out. Likewise, we show that RTN affects only a small and fixed population of pixels. It can therefore be tracked using standard pixel operability maps.

Rauscher, Bernard J.↗

Heated Surface Temperatures Measured by Infrared Detector in a Cascade Environment

Investigators have used infrared devices to accurately measure heated surface temperatures. Several of these applications have been for turbine heat transfer studies involving film cooling and surface roughness, typically, these measurements use an infrared camera positioned externally to the test section. In cascade studies, where several blades are used to ensure periodic flow, adjacent blades block the externally positioned camera's views of the test blade. To obtain a more complete mapping of the surface temperatures, researchers at the NASA Glenn Research Center fabricated a probe with an infrared detector to sense the blade temperatures. The probe size was kept small to minimize the flow disturbance. By traversing and rotating the probe, using the same approach as for total pressure surveys, one can find the blade surface temperatures. Probe mounted infrared detectors are appropriate for measuring surface temperatures where an externally positioned infrared camera is unable to completely view the test object. This probe consists of a 8-mm gallium arsenide (GaAs) lens mounted in front of a mercury-cadmium-zinc-tellurium (HgCdZnTe) detector. This type of photovoltaic detector was chosen because of its high sensitivity to temperature when the detector is uncooled. The particular application is for relatively low surface temperatures, typically ambient to 100 C. This requires a detector sensitive at long wavelengths. The detector is a commercial product enclosed in a 9-mm-diameter package. The GaAs lens material was chosen because of its glass-like hardness and its good long-wavelength transmission characteristics. When assembled, the 6.4-mm probe stem is held in the traversing actuator. Since the entire probe is above the measurement plane, the flow field disturbance in the measurement plane is minimized. This particular probe body is somewhat wider than necessary, because it was designed to have replaceable detectors and lenses. The signal for the detector is fed through the hollow probe body. The detector's signal goes to an externally mounted preamplifier. The detector assembly, along with a preamplifier, is calibrated as a function of the surface temperature for various detector temperatures. The output voltage is a function of both the detector and object temperatures.

Boyle, Robert J.↗

Multiyear On-orbit Calibration and Performance of Terra MODIS Thermal Emissive Bands

Since launch in December 1999, Terra MODIS has been making continuous Earth observations for more than seven years. It has produced a broad range of land, ocean, and atmospheric science data products for improvements in studies of global climate and environmental change. Among its 36 spectral bands, there are 20 reflective solar bands (RSB) and 16 thermal emissive bands (TEB). MODIS thermal emissive bands cover the mid-wave infrared (MWIR) and long-wave infrared (LWIR) spectral regions with wavelengths from 3.7 to 14.4pm. They are calibrated on-orbit using an on-board blackbody (BB) with its temperature measured by a set of thermistors on a scan-by-scan basis. This paper will provide a brief overview of MODIS TEB calibration and characterization methodologies and illustrate on-board BB functions and TEB performance over more than seven years of on-orbit operation and calibration. Discussions will be focused on TEB detector short-term stability and noise characterization, and changes in long-term response (or system gain). Results show that Terra MODIS BB operation has been extremely stable since launch. When operated at its nominal controlled temperature of 290K, the BB temperature variation is typically less than +0.30mK on a scan-by-scan basis and there has been no time-dependent temperature drift. In addition to excellent short-term stability, most TEB detectors continue to meet or exceed their specified noise characterization requirements, thus enabling calibration accuracy and science data product quality to be maintained. Excluding the noisy detectors identified pre-launch and those that occurred post-launch, the changes in TEB responses have been less than 0.7% on an annual basis. The optical leak corrections applied to bands 32-36 have been effective and stable over the entire mission

Xiong, Xiaoxiong↗

BATSE Observations of Gamma-Ray Burst Spectra: Low-Energy Behavior of Time-Averaged Spectra - Part 3

We analyze time-averaged spectra from 86 bright gamma-ray bursts from the first 5 years of the Burst And Transient Source Experiment (BATSE) on board the Compton Gamma Ray Observatory to determine whether the lowest energy data are consistent with a standard spectra form fit to the data at all energies. The BATSE Spectroscopy Detectors have the capability to observe photons as low as 5 keV. Using the gamma-ray burst locations obtained with the BATSE Large Area Detectors, the Spectroscopy Detectors' low-energy response can be modeled accurately. This, together with a postlaunch calibration of the lowest energy Spectroscopy Detector discriminator channel, which can lie in the range 5-20 keV, allows spectral deconvolution over a broad energy range, approx. 5 keV to 2 MeV. The additional coverage allows us to search for evidence of excess emission, or for a deficit, below 20 keV. While no burst has a significant (greater than or equal to 3 sigma) deficit relative to a standard spectra model, we find that 12 bursts have excess low-energy emission, ranging between 1.2 and 5.8 times the model flux, that exceeds 5 sigma in significance. This is evidence for an additional low-energy spectral component in at least some bursts, or for deviations from the power-law spectral form typically used to model gamma-ray bursts at energies below 100 keV.

Preece, R. D.↗

The response of covered silicon detectors to monoenergetic gamma rays

Measurements were made of the efficiency in detecting gamma rays of a 0.3-mm, a 3-mm, and a 5-mm silicon detector covered with different absorbers. Calibrated sources covering the range from 279 KeV to 2.75 MeV were used. The need for the absorbers in order to obtain meaningful results, and their contribution to detector response at electron biases from 50 to 200 KeV, are discussed in detail. It is shown that the results are independent of the atomic number of the absorber. In addition, the role of the absorber in increasing the efficiency with increasing photon energy for low bias setting is demonstrated for the 0.3-mm crystal. Qualitative explanations are given for the shapes of all curves of efficiency versus energy at each bias.

Reier, M.↗

Early Calibration and Performance Assessments of NOAA-20 VIIRS Thermal Emissive Bands

The Visible Infrared Imaging Radiometer Suite (VIIRS) sensor aboard the NOAA-20 (previously JPSS-1) spacecraft has successfully operated since its launch in November, 2017. Similar to the first VIIRS instrument on the Suomi-NPP spacecraft, data is collected in 22 spectral bands that are calibrated by a set of onboard calibrators. This paper provides an overview of the NOAA-20 VIIRS on-orbit operation and calibration, with a particular focus on the thermal emissive bands (TEBs). Results presented in this paper include the on-orbit changes in the TEB spectral band responses, detector noise characterization, and key calibration parameters, such as the non-linear coefficients derived from the blackbody warm-up cool-down cycle. Other issues, such as the early mission long-wave infrared (LWIR) response degradation due to icing on the dewar window, and their impact on sensor calibration are also discussed. Since launch, the VIIRS instrument temperature has been stable to within ± 0.8K and the cold focal plane temperatures are well controlled with variations less than 40 mK. With the exception of the early degradation observed in the LWIR bands, the TEB gains have been stable to within 0.04% (except I5 at 0.07%). Based on the current performance, VIIRS is expected to meet its calibration requirements throughout its design lifetime.

NEdT↗

Early Calibration and Performance Assessments of NOAA-20 VIIRS Thermal Emissive Bands

The Visible Infrared Imaging Radiometer Suite (VIIRS) sensor aboard the NOAA-20 (previously JPSS-1) spacecraft has successfully operated since its launch in November, 2017. Similar to the rst VIIRS instrument on the Suomi-National Polar-orbiting Partnership (SNPP) spacecraft, the data are collected in 22 spectral bands that are calibrated by a set of onboard calibrators. This paper provides an overview of the NOAA-20 VIIRS on-orbit operation and calibration, with a particular focus on the thermal emissive bands (TEBs). The results presented in this paper include the on-orbit changes in the TEB spectral band responses, detector noise characterization, and key calibration parameters, such as the nonlinear coefcients derived from the blackbody warm-up cool-down cycles. Other issues, such as the early mission long-wave infrared (LWIR) response degradation due to icing on the dewar window, and their impact on sensor calibration are also discussed. Since launch, the VIIRS instrument temperature has been stable to within ±0.8 K and the cold focal plane temperatures are well controlled with variations less than 40 mK. With the exception of the early degradation observed in the LWIR bands, the TEB gains have been stable to within 0.04% (except I5 at 0.07%). Based on the current performance, VIIRS is expected to meet its calibration requirements throughout its design lifetime.

noise equivalent 25 differential temperature (NEdT↗

Hawkeye Radiometric Calibration Methodology

Hawkeye is an ocean color instrument designed, manufactured and characterized at Cloud land Instruments, CA. It is a push broom instrument that has 8spectral bands similar to SeaWiFS and a spatial resolution of 120 m. Each spectral band has 1800 detectors (pixels) and all 14,000 detectors (pixels) need to be calibrated independently. This paper describes the preliminary design of on-orbit calibration method to correct for the instrument response's temperature sensitivity,scan angle dependency in radiometric sensitivity, relative spectral response (RSR),non linearity, and polarization sensitivity. We will provide a brief description on how each of the calibration parameters are used to address the instrument characteristics and how the calibration parameters are derived from instrument test data and use to retrieve ocean color products.

Lee, Shihyan↗

The response of covered silicon detectors to monoenergetic gamma rays.

Measurements have been made of the efficiency in detecting gamma rays of a 0.3-mm-, 3-mm-, and 5-mm-thick silicon detector covered with different absorbers. Calibrated sources over the range from 279 keV to 2.75 MeV were used. The need for the absorbers to obtain meaningful results and their contribution to the response of the detectors at electron biases from 50 to 200 keV are discussed in detail. It is shown that the results are virtually independent of the atomic number of the absorber. In addition, the role of the absorber in increasing the efficiency with increasing photon energy for low bias settings is demonstrated for the 0.3-mm crystal. Qualitative explanations are given for the shapes of all curves of efficiency versus energy at each bias.

Reier, M.↗

Absolute Effective Area of the Chandra High-Resolution Mirror Assembly

The Chandra X-ray Observatory was launched in July 1999, and is returning exquisite sub-arcsecond x-ray images of star groups, supernova remnants, galaxies, quasars, and clusters of galaxies. In addition to being the premier X-ray observatory in terms of angular and spectral resolution, Chandra is the best calibrated X-ray facility ever flown. We discuss here the calibration of the effective area of the High Resolution Mirror Assembly. Because we do not know the absolute X-ray flux density of any celestial source, this must be based primarily on ground measurements and on modeling. In particular, we must remove the calibrated modeled responses of the detectors and gratings to obtain the mirror area. For celestial sources which may be assumed to have smoothly varying spectra, such as the Crab Nebula, we may verify the continuity of the area calibration as a function of energy. This is of significance in energy regions such as the Ir M-edges, or near the critical grazing angle cutoff of the various mirror shells.

Schwartz, D. A.↗

Prelaunch absolute radiometric calibration of the reflective bands on the LANDSAT-4 protoflight Thematic Mapper

The results of the absolute radiometric calibration of the LANDSAT 4 thematic mapper, as determined during pre-launch tests with a 122 cm integrating sphere, are presented. Detailed results for the best calibration of the protoflight TM are given, as well as summaries of other tests performed on the sensor. The dynamic range of the TM is within a few per cent of that required in all bands, except bands 1 and 3. Three detectors failed to pass the minimum SNR specified for their respective bands: band 5, channel 3 (dead), band 2, and channels 2 and 4 (noisy or slow response). Estimates of the absolute calibration accuracy for the TM show that the detectors are typically calibrated to 5% absolute error for the reflective bands; 10% full-scale accuracy was specified. Ten tests performed to transfer the detector absolute calibration to the internal calibrator show a 5% range at full scale in the transfer calibration; however, in two cases band 5 showed a 10% and a 7% difference.

Barker, J. L.↗

Calibration of the MSL/ChemCam/LIBS Remote Sensing Composition Instrument

The ChemCam instrument suite on board the 2011 Mars Science Laboratory (MSL) Rover, Curiosity, will provide remote-sensing composition information for rock and soil samples within seven meters of the rover using a laser-induced breakdown spectroscopy (LIBS) system, and will provide context imaging with a resolution of 0.10 mradians using the remote micro-imager (RMI) camera. The high resolution is needed to image the small analysis footprint of the LIBS system, at 0.2-0.6 mm diameter. This fine scale analytical capability will enable remote probing of stratigraphic layers or other small features the size of "blueberries" or smaller. ChemCam is intended for rapid survey analyses within 7 m of the rover, with each measurement taking less than 6 minutes. Repeated laser pulses remove dust coatings and provide depth profiles through weathering layers, allowing detailed investigation of rock varnish features as well as analysis of the underlying pristine rock composition. The LIBS technique uses brief laser pulses greater than 10 MW/square mm to ablate and electrically excite material from the sample of interest. The plasma emits photons with wavelengths characteristic of the elements present in the material, permitting detection and quantification of nearly all elements, including the light elements H, Li, Be, B, C, N, O. ChemCam LIBS projects 14 mJ of 1067 nm photons on target and covers a spectral range of 240-850 nm with resolutions between 0.15 and 0.60 nm FWHM. The Nd:KGW laser is passively cooled and is tuned to provide maximum power output from -10 to 0 C, though it can operate at 20% degraded energy output at room temperature. Preliminary calibrations were carried out on the flight model (FM) in 2008. However, the detectors were replaced in 2009, and final calibrations occurred in April-June, 2010. This presentation describes the LIBS calibration and characterization procedures and results, and details plans for final analyses during rover system thermal testing, planned for early March.

Wiens, R. C.↗

MODIS Detector Differences Using Deep Convective Clouds and Desert Targets

An accurate on-orbit characterization of the Moderate Resolution Imaging Spectroradiometer (MODIS) sensors onboard the Terra and Aqua satellites is essential to satisfy the requirements from the scientific community for high-quality operational and research products. In this study, NASA’s C6.1 L1B data are utilized to assess the stability of the calibrated top of atmosphere reflectance retrieved from individual detectors within a spectral band over deep convective clouds (DCCs) and desert sites. The results from these invariant Earth targets show detector-to-detector (D2D) differences in the L1B reflectance products for select MODIS reflective solar bands. For Aqua MODIS, the D2D differences have no significant change over time for the bands studied. However, the D2D differences exhibit an increase in magnitude over time for Terra MODIS bands 1, 3-7, and 26, which can induce noticeable striping and higher uncertainties in the downstream data products. The D2D stability assessment results over DCCs are consistent with those observed over desert sites. In addition, the view-angle dependence of the D2D differences is investigated by separating the frames along scan into five zones. The D2D assessment is performed for each of the five zones, and the results will further benefit any improvements in the calibration of a detector-dependent response versus scan angle that can be considered for future MODIS Level 1B Collections.

MODIS↗

MODIS Reflective Solar Bands On-Orbit Calibration and Performance

The design of the MODIS instrument was driven by the scientific community's desire to have near-daily global coverage at moderate resolution (1 km) with a comprehensive spectral coverage from visible to long-wave infrared wavelengths. Since their launches in 1999 and 2002, respectively, the Terra and Aqua MODIS instruments have made continuous global observations and generated numerous data products to help users worldwide with their studies of the Earth's system and its short- and long-term changes. The 20 reflective solar bands (RSB) with wavelengths from 0.41 to 2.2 m collect data at three nadir spatial resolutions: 250 m, 500 m, and 1 km. The solar diffuser (SD) coupled with the solar diffuser stability monitor (SDSM) provide a reflectance-based calibration on-orbit. In addition, lunar observations and response trends from pseudo-invariant desert sites are used to characterize the response versus scan- angle changes on-orbit. This paper provides a brief overview of MODIS RSB calibration algorithms, as implemented in the latest Level 1B version 6.1, operational activities, on-orbit performance, remaining challenges and potential improvements. Results from the SD and SDSM measurements show a wavelength and mirror side dependent degradation in RSB responses, with the largest degradation at the shortest wavelengths, particularly for Terra MODIS. Aqua MODIS has experienced far less degradation of its optics and on-board calibrators compared to Terra MODIS, resulting in an overall better performance. With the exception of Aqua band 6, there have been no new noisy or inoperable detectors in the RSB of either instrument during post-launch operations. As the instruments age and continue to endure the space environment, the detectors and optical systems degrade. The challenges associated with incorporating these on-orbit changes to ensure a production of high-quality calibrated L1B data products are also discussed in this paper.

solar diffuser stability monitor↗

Cryogenic Optical Systems and Instrumentation IX (AM 116) Newly Modified Cryogenic Optical Test Facility at the Marshall Space Flight Center

Marshall Space Flight Center (MSFC) has maintained and operated a world-class x-ray optics and detector testing facility known as the X-ray Calibration Facility (XRCF) since the mid 1970's. The ground test and calibration of the Chandra X-ray Observatory optics and detectors were successfully completed at the XRCF in 1997. The beginning of the Next Generation Space Telescope (NGST) development programs (NMSD, SBMD, AMSD, etc.) and the establishment of the Space Optics Manufacturing Technology Center at MSFC have led to an XRCF modification. In 1999 the facility was upgraded to perform cryogenic testing of lightweight visible optics (without compromising the existing x-ray testing capability). A thermal enclosure capable of 20 degrees Kelvin and vibration isolated instrumentation mount were added. A vacuum-compatible five-axis motion table was modified to operate under cryogenic conditions. Optics up to two meters in diameter with radii of curvature of up to twenty meters can be accommodated. Facility characterization tests and one NGST program mirror test have been completed to date. By July 2000, two other mirrors will be tested. Optical wavefront measurements were made at < 35 degrees Kelvin with several instruments located at the test mirror's radius of curvature. The current wavefront measuring instruments include a Shack-Hartman wavefront sensor, a point diffraction interferometer, a point spread function-measuring device, and a radius of curvature measuring instrument. A vibration insensitive phase shifting interferometer is planned for future optical testing. This paper will present a brief history of the facility, a discussion of its current x-ray optic testing capabilities, and a complete description of the new capabilities in the visible optical testing regime.

Eng, Ronnie↗