Search NASA⌕ Search

SEARCH · Search NASA

Results for “deterministic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Impact of Heterogeneity-Based Dose Calculation Using a Deterministic Grid-Based Boltzmann Equation Solver for Intracavitary Brachytherapy

Purpose: To investigate the dosimetric impact of the heterogeneity dose calculation Acuros (Transpire Inc., Gig Harbor, WA), a grid-based Boltzmann equation solver (GBBS), for brachytherapy in a cohort of cervical cancer patients. Methods and Materials: The impact of heterogeneities was retrospectively assessed in treatment plans for 26 patients who had previously received {sup 192}Ir intracavitary brachytherapy for cervical cancer with computed tomography (CT)/magnetic resonance-compatible tandems and unshielded colpostats. The GBBS models sources, patient boundaries, applicators, and tissue heterogeneities. Multiple GBBS calculations were performed with and without solid model applicator, with and without overriding the patient contour to 1 g/cm{sup 3} muscle, and with and without overriding contrast materials to muscle or 2.25 g/cm{sup 3} bone. Impact of source and boundary modeling, applicator, tissue heterogeneities, and sensitivity of CT-to-material mapping of contrast were derived from the multiple calculations. American Association of Physicists in Medicine Task Group 43 (TG-43) guidelines and the GBBS were compared for the following clinical dosimetric parameters: Manchester points A and B, International Commission on Radiation Units and Measurements (ICRU) report 38 rectal and bladder points, three and nine o'clock, and {sub D2cm3} to the bladder, rectum, and sigmoid. Results: Points A and B, D{sub 2} cm{sup 3} bladder, ICRU bladder, and three and nine o'clock were within 5% of TG-43 for all GBBS calculations. The source and boundary and applicator account for most of the differences between the GBBS and TG-43 guidelines. The D{sub 2cm3} rectum (n = 3), D{sub 2cm3} sigmoid (n = 1), and ICRU rectum (n = 6) had differences of >5% from TG-43 for the worst case incorrect mapping of contrast to bone. Clinical dosimetric parameters were within 5% of TG-43 when rectal and balloon contrast were mapped to bone and radiopaque packing was not overridden. Conclusions: The GBBS has minimal impact on clinical parameters for this cohort of patients with unshielded applicators. The incorrect mapping of rectal and balloon contrast does not have a significant impact on clinical parameters. Rectal parameters may be sensitive to the mapping of radiopaque packing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Formulations and analysis of Compton scattering for deterministic thermal radiation transport

In high-energy-density physics at low densities and high temperatures, Compton scattering can be the dominant interaction mechanism between thermal radiation and the material. Boson statistics leads to induced scattering, where the rate of scattering is proportional to the square of the photon intensity. To explore the importance of this nonlinear effect in the context of thermal radiative transfer, in this work we formulate several linear approximations to the scattering rate and compare them to the proper nonlinear rate in an infinite-medium setting. With the goal of implementing Compton scattering in a radiation transport code, we study heating-rate accuracy and iterative convergence properties for the linear methods as we vary the fidelity of the discretization in photon frequency. We find the equilibrium out-scattering formulation to be the most accurate linear method, with heating rate errors around 15% when the radiation is heating the material and up to 50% when the radiation is cooling the material.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deterministic chaos in the self-assembly of β sheet nanotubes from an amphipathic oligopeptide

The self-assembly of designed peptides into filaments and other higher-order structures has been the focus of intense interest because of the potential for creating new biomaterials and biomedical devices. These peptide assemblies have also been used as models for understanding biological processes, such as the pathological formation of amyloid. Here we investigate the assembly of an octapeptide sequence, Ac-FKFEFKFE-NH2, motivated by prior studies that demonstrated that this amphipathic beta strand peptide self-assembled into fibrils and biocompatible hydrogels. Using high-resolution cryoelectron microscopy (cryo-EM), we are able to determine the atomic structure for two different coexisting forms of the fibrils, containing four and five beta sandwich protofilaments, respectively. Surprisingly, the inner walls in both forms are parallel beta sheets, while the outer walls are antiparallel beta sheets. Our results demonstrate the chaotic nature of peptide self-assembly and illustrate the importance of cryo-EM structural analysis to understand the complex phase behavior of these materials at near-atomic resolution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cumulative dose of radiation therapy of hepatocellular carcinoma patients and its deterministic relation to radiation-induced liver disease

This study aimed to investigate the relationship between dose and radiation-induced liver disease (RILD) in patients with hepatocellular carcinoma (HCC) receiving 3-dimensional conformal radiotherapy (3DCRT). Twenty-three patients with HCC who received conventional fractionated 3DCRT, including 7 who were diagnosed with classic RILD, were enrolled in this retrospective investigation. Cone-beam computed tomography (CBCT) scans were acquired at the time of treatment for each patient. The beams from each patient's treatment plan were applied to each pretreatment CBCT (the modified CBCT or mCBCT) to construct the delivered dose distribution of the day considering inter-treatment anatomy changes. The daily doses were summed together with the help of deformable image registration (DIR) to obtain the adjusted cumulative dose (D{sub adjusted}). The dose changes to the normal liver between the original planned dose (D{sub plan}) and D{sub adjusted} were evaluated by V20, V30, V40, and the mean dose to normal liver (MDTNL). Univariate analysis was performed to identify the significant dose changes. Among the 23 patients, the liver V20, V30, V40, and MDTNL showed significant differences between D{sub plan} and D{sub adjusted}, with average values of these parameters increased by 4.1%, 4.7%, 4.5%, and 3.9 Gy, respectively (p adjusted . Determination of a reconstructed D{sub adjusted} using the mCBCT scans are more accurate in predicting RILD and has the potential to reduce the risk of RILD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evolution of brachytherapy treatment planning to deterministic radiation transport for calculation of cardiac dose

Brachytherapy was among the first methods of radiotherapy and has steadily continued to evolve. Here we present a brief review of the progression of dose calculation methods in brachytherapy to the current state-of-the art computerized methods for heterogeneity correction. We further review the origin and development of the BrachyVision (Varian Medical Systems, Inc., Palo Alto, CA) treatment planning system and evaluate dosimetric results from 12 patients implanted with the strut-assisted volumetric implant (SAVI) applicator (Cianna Medical, Aliso Viejo, CA) for accelerated partial breast irradiation (APBI). Dosimetric results from plans calculated using homogenous and heterogeneous algorithms have been compared to investigate the impact of heterogeneity corrections. Our study showed large percent difference between mean cardiac doses 11.8 ± 6.2% (p = 0.0007) calculated with and without heterogeneity corrections. Our findings are consistent with those of others, indicating an overestimation of the distal dose to organs-at-risk by traditional methods, especially at interfaces between air and tissue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A deterministic gradient-based approach to avoid saddle points

Abstract Loss functions with a large number of saddle points are one of the major obstacles for training modern machine learning (ML) models efficiently. First-order methods such as gradient descent (GD) are usually the methods of choice for training ML models. However, these methods converge to saddle points for certain choices of initial guesses. In this paper, we propose a modification of the recently proposed Laplacian smoothing gradient descent (LSGD) [Osher et al., arXiv:1806.06317 ], called modified LSGD (mLSGD), and demonstrate its potential to avoid saddle points without sacrificing the convergence rate. Our analysis is based on the attraction region, formed by all starting points for which the considered numerical scheme converges to a saddle point. We investigate the attraction region’s dimension both analytically and numerically. For a canonical class of quadratic functions, we show that the dimension of the attraction region for mLSGD is $\lfloor (n-1)/2\rfloor$ , and hence it is significantly smaller than that of GD whose dimension is $n-1$ .

Mathematics↗

Stabilizing Ultrathin CsPbBr 3 Nanoplatelet Films for Deterministic Strong Light-Matter Coupling

While the excitons in perovskite nanomaterials possess interesting properties central to their use in optoelectronic technologies, their instability limits real world applicability. In this study, we describe a method to stabilize the structures of cesium lead bromide (CsPbBr 3 ) nanoplatelets (NPLs) in spin-casted films. We apply this method to design, fabricate, and characterize exciton cavity polaritons formed from these nanomaterials. These studies show that we can form exciton cavity polaritons from CsPbBr 3 in precisely designed Fabry−Perot microresonators and suggest that the structures of these materials can be stabilized toward their use in other solution-processed optoelectronic devices.

cavities↗

Charged Ferroelectric Domain Walls for Deterministic ac Signal Control at the Nanoscale

The direct current (dc) conductivity and emergent functionalities at ferroelectric domain walls are closely linked to the local polarization charges. Depending on the charge state, the walls can exhibit unusual dc conduction ranging from insulating to metallic-like, which is leveraged in domain-wall-based memory, multilevel data storage, and synaptic devices. In contrast to the functional dc behaviors at charged walls, their response to alternating currents (ac) remains to be resolved. Here, we reveal ac characteristics at positively and negatively charged walls in ErMnO 3 , distinctly different from the response of the surrounding domains. By combining voltage-dependent spectroscopic measurements on macroscopic and local scales, we demonstrate a pronounced nonlinear response at the electrode-wall junction, which correlates with the domain-wall charge state. The dependence on the ac drive voltage enables reversible switching between uni- and bipolar output signals, providing conceptually new opportunities for the application of charged walls as functional nanoelements in ac circuitry.

77 NANOSCIENCE AND NANOTECHNOLOGY↗