Search NASA⌕ Search

SEARCH · Search NASA

Results for “deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

SU-F-J-43: Positional Variation of Implanted Fiducial Markers Over the Course of Image Guided Radiotherapy for Pancreatic Cancer

Purpose: Pancreas is a soft-tissue organ, implanted fiducials can change positions due to migration or tissue deformation. This study quantified positional variation of fiducials in IGRT for pancreatic cancer. Methods: 20 patients had at least 3 gold fiducials implanted in pancreas under EUS guidance. Patients had 4D-CT simulation for gated treatment. Daily gated OBI kV images (Turebeam) were used for positional alignment with fiducials for total of 25 or 28 fractions. Relative distances among 3 fiducials (d{sub 1–} {sub 2}, d{sub 1–3}, d{sub 2–3}) were measured from 4D-CT end-of-expiration phase bin; and from gated kV images in first, mid, and last fraction (n=180). Results: The median duration between implant and simulation was 11 (range 0–41) days. The median duration between simulation and first fraction was 17 (range 8–24) days. The median relative distance was 12 (range 4–78) mm for d{sub 1–2}, 24 (range 6–80) mm for d{sub 1–3}, and 19 (range 5–63) mm for d{sub 2–3}. The median deviation was 1 mm for d{sub 1–2}, d{sub 1–3}, d{sub 2–3} between simulation and first fraction, first and mid fraction, mid and last fraction (n=180). Two patients (10%) had deviation >= 5 mm (5, 11 mm) between simulation and first fraction. One patient (5%) had deviation >= 5 mm (11 mm) between first and mid fraction. No patient (0%) had deviation >= 5 mm between mid and last fraction. In all 3 cases with deviation >=5 mm, only one fiducial was significantly deviated. No clear evidence that deviation size was associated with time interval between implant and first fraction. Conclusion: Implanted gold fiducials were quite stable over time in their relative positions in pancreas. Our data suggested at least 3 fiducials are needed. In cases that one fiducial was significantly deviated in daily kV images, this fiducial should be excluded in image guidance.

60 APPLIED LIFE SCIENCES↗

Photometric Redshifts with the LSST. II. The Impact of Near-infrared and Near-ultraviolet Photometry

Accurate photometric redshift (photo-z) estimates are essential to the cosmological science goals of the Vera C. Rubin Observatory Legacy Survey of Space and Time (LSST). In this work, we use simulated photometry for mock galaxy catalogs to explore how LSST photo-z estimates can be improved by the addition of near-infrared (NIR) and/or ultraviolet (UV) photometry from the Euclid, Wide-Field InfrarRed Survey Telescope (WFIRST), and/or Cosmological Advanced Survey Telescope for Optical and ultraviolet Research (CASTOR) space telescopes. Generally, we find that deeper optical photometry can reduce the standard deviation of the photo-z estimates more than adding NIR or UV filters but that additional filters are the only way to significantly lower the fraction of galaxies with catastrophically under- or overestimated photo-z. For Euclid, we find that the addition of JH 5σ photometric detections can reduce the standard deviation for galaxies with z > 1 (z > 0.3) by ∼20% (∼10%), and the fraction of outliers by ∼40% (∼25%). For WFIRST, we show how the addition of deep YJHK photometry could reduce the standard deviation by ≳50% at z > 1.5 and drastically reduce the fraction of outliers to just ∼2% overall. For CASTOR, we find that the addition of its UV- and u-band photometry could reduce the standard deviation by ∼30% and the fraction of outliers by ∼50% for galaxies with z < 0.5. We also evaluate the photo-z results within sky areas that overlap with both the NIR and UV surveys and when spectroscopic training sets built from the surveys’ small-area deep fields are used.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of buildings on surface solar radiation over urban Beijing

The rugged surface of an urban area due to varying buildings can interact with solar beams and affect both the magnitude and spatiotemporal distribution of surface solar fluxes. Here we systematically examine the impact of buildings on downward surface solar fluxes over urban Beijing by using a 3-D radiation parameterization that accounts for 3-D building structures vs. the conventional plane-parallel scheme. We find that the resulting downward surface solar flux deviations between the 3-D and the plane-parallel schemes are generally ±1–10 W m -2 at 800 m grid resolution and within ±1 W m -2 at 4 km resolution. Pairs of positive–negative flux deviations on different sides of buildings are resolved at 800 m resolution, while they offset each other at 4 km resolution. Flux deviations from the unobstructed horizontal surface at 4 km resolution are positive around noon but negative in the early morning and late afternoon. The corresponding deviations at 800 m resolution, in contrast, show diurnal variations that are strongly dependent on the location of the grids relative to the buildings. Both the magnitude and spatiotemporal variations of flux deviations are largely dominated by the direct flux. Furthermore, we find that flux deviations can potentially be an order of magnitude larger by using a finer grid resolution. Atmospheric aerosols can reduce the magnitude of downward surface solar flux deviations by 10–65 %, while the surface albedo generally has a rather moderate impact on flux deviations. The results imply that the effect of buildings on downward surface solar fluxes may not be critically significant in mesoscale atmospheric models with a grid resolution of 4 km or coarser. However, the effect can play a crucial role in meso-urban atmospheric models as well as microscale urban dispersion models with resolutions of 1 m to 1 km.

54 ENVIRONMENTAL SCIENCES↗

Adaptive Gain-based Stable Power Smoothing of a DFIG

In a power system that has a high wind penetration, the output power fluctuation of a large-scale wind turbine generator (WTG) caused by the varying wind speed increases the maximum frequency deviation, which is an important metric to assess the quality of electricity, because of the reduced system inertia. This paper proposes a stable power-smoothing scheme of a doubly-fed induction generator (DFIG) that can suppress the maximum frequency deviation, particularly for a power system with a high wind penetration. To do this, the proposed scheme employs an additional control loop relying on the system frequency deviation that operates in combination with the maximum power point tracking control loop. To improve the power-smoothing capability while guaranteeing the stable operation of a DFIG, the gain of the additional loop is modified with the rotor speed and frequency deviation. The gain is set to be high if the rotor speed and/or frequency deviation is large. Here, the simulation results based on the IEEE 14-bus system demonstrate that the proposed scheme significantly lessens the output power fluctuation of a WTG under various scenarios by modifying the gain with the rotor speed and frequency deviation, and thereby it can regulate the frequency deviation within a narrow range.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Accumulated Dose in Liver Stereotactic Body Radiotherapy: Positioning, Breathing, and Deformation Effects

Purpose: To investigate the accumulated dose deviations to tumors and normal tissues in liver stereotactic body radiotherapy (SBRT) and investigate their geometric causes. Methods and Materials: Thirty previously treated liver cancer patients were retrospectively evaluated. Stereotactic body radiotherapy was planned on the static exhale CT for 27-60 Gy in 6 fractions, and patients were treated in free-breathing with daily cone-beam CT guidance. Biomechanical model-based deformable image registration accumulated dose over both the planning four-dimensional (4D) CT (predicted breathing dose) and also over each fraction's respiratory-correlated cone-beam CT (accumulated treatment dose). The contribution of different geometric errors to changes between the accumulated and predicted breathing dose were quantified. Results: Twenty-one patients (70%) had accumulated dose deviations relative to the planned static prescription dose >5%, ranging from -15% to 5% in tumors and -42% to 8% in normal tissues. Sixteen patients (53%) still had deviations relative to the 4D CT-predicted dose, which were similar in magnitude. Thirty-two tissues in these 16 patients had deviations >5% relative to the 4D CT-predicted dose, and residual setup errors (n = 17) were most often the largest cause of the deviations, followed by deformations (n = 8) and breathing variations (n = 7). Conclusion: The majority of patients had accumulated dose deviations >5% relative to the static plan. Significant deviations relative to the predicted breathing dose still occurred in more than half the patients, commonly owing to residual setup errors. Accumulated SBRT dose may be warranted to pursue further dose escalation, adaptive SBRT, and aid in correlation with clinical outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Couch height–based patient setup for abdominal radiation therapy

There are 2 methods commonly used for patient positioning in the anterior-posterior (A-P) direction: one is the skin mark patient setup method (SMPS) and the other is the couch height–based patient setup method (CHPS). This study compared the setup accuracy of these 2 methods for abdominal radiation therapy. The enrollment for this study comprised 23 patients with pancreatic cancer. For treatments (539 sessions), patients were set up by using isocenter skin marks and thereafter treatment couch was shifted so that the distance between the isocenter and the upper side of the treatment couch was equal to that indicated on the computed tomographic (CT) image. Setup deviation in the A-P direction for CHPS was measured by matching the spine of the digitally reconstructed radiograph (DRR) of a lateral beam at simulation with that of the corresponding time-integrated electronic portal image. For SMPS with no correction (SMPS/NC), setup deviation was calculated based on the couch-level difference between SMPS and CHPS. SMPS/NC was corrected using 2 off-line correction protocols: no action level (SMPS/NAL) and extended NAL (SMPS/eNAL) protocols. Margins to compensate for deviations were calculated using the Stroom formula. A-P deviation > 5 mm was observed in 17% of SMPS/NC, 4% of SMPS/NAL, and 4% of SMPS/eNAL sessions but only in one CHPS session. For SMPS/NC, 7 patients (30%) showed deviations at an increasing rate of > 0.1 mm/fraction, but for CHPS, no such trend was observed. The standard deviations (SDs) of systematic error (Σ) were 2.6, 1.4, 0.6, and 0.8 mm and the root mean squares of random error (σ) were 2.1, 2.6, 2.7, and 0.9 mm for SMPS/NC, SMPS/NAL, SMPS/eNAL, and CHPS, respectively. Margins to compensate for the deviations were wide for SMPS/NC (6.7 mm), smaller for SMPS/NAL (4.6 mm) and SMPS/eNAL (3.1 mm), and smallest for CHPS (2.2 mm). Achieving better setup with smaller margins, CHPS appears to be a reproducible method for abdominal patient setup.

61 RADIATION PROTECTION AND DOSIMETRY↗

Anomalies in the topology of the temperature fluctuations in the cosmic microwave background: An analysis of the NPIPE and FFP10 data releases

We present a topological analysis of the temperature fluctuation maps from the Planck 2020 Data Release 4 NPIPE dataset and the Planck 2018 Data Release 3 FFP10 dataset. We performed a multiscale analysis in terms of the homology characteristics of the maps, invoking relative homology to account for the analysis in the presence of masks. We performed our analysis for a range of smoothing scales spanning sub- and super-horizon scales corresponding to a full width at half maximum (FWHM) of 5',10',20',40',80',160',320', and 640', and employed simulations based on the standard model for comparison, which assumes the initial fluctuation field to be an isotropic and homogeneous Gaussian random field. Examining the behavior of topological components, represented by the 0D homology group, we find the observations to be approximately 2σ or less deviant from the simulations for all resolutions and scales for the NPIPE dataset. For the FFP10 dataset, we detect a 2.96σ deviation between the observations and simulations at N = 128, FWHM = 80'. For the topological loops, represented by the first homology group, the simulations and observations are consistent within 2σ for most resolutions and scales for both the datasets. However, for the NPIPE dataset, we observe a high deviation between the observation and simulations in the number of loops at FWHM = 320', but at a low dimensionless threshold ν = –2.5. Under a Gaussian assumption, this would amount to a deviation of ~4σ. However, the distribution in this bin is manifestly non-Gaussian and does not obey Poisson statistics either. In the absence of a true theoretical understanding, we simply note that the significance is higher than what may be resolved by 600 simulations, yielding an empirical p-value of at most 0.0016. Specifically in this case, our tests indicate that the numbers arise from a statistically stable regime, despite being based on small numbers. For the FFP10 dataset, the differences are not as strong as for the NPIPE dataset, indicating a 2.77σ deviation at this resolution and threshold. The Euler characteristic, which is the alternating sum of the ranks of relative homology groups, reflects the deviations in the components and loops. To assess the significance of combined levels for a given scale, we employed the empirical and theoretical versions of the χ 2 test as well as the nonparametric Tukey depth test. Although all statistics exhibit a stable distribution, we favor the empirical version of the χ 2 test in the final interpretation, as it indicates the most conservative differences. For the NPIPE dataset, we find that the components and loops differ at more than 95%, but agree within the 99% confidence level with respect to the base model at N = 32, FWHM = 320'. The Euler characteristic at this resolution displays a per mil deviation. In contrast, the FFP10 dataset shows that the observations are consistent with the base model within the 95% confidence level, at this and smaller scales. This is consistent with the observations of the Planck analysis pipeline via Minkowski functionals. For the largest smoothing scale, N = 16, FWHM = 640', both datasets exhibit an anomalous behavior of the loops, where FFP10 data exhibit a deviation that is larger by an order of magnitude than that of the NPIPE dataset. In contrast, the values for the topological components and the Euler characteristic agree between observations and model to within a confidence level of 99%. However, for the largest scales, the statistics are based on low numbers and may have to be regarded with caution. Even though both datasets exhibit mild to significant discrepancies, they also exhibit contrasting behaviors at various instances. Therefore, we do not find it feasible to convincingly accept or reject the null hypothesis. Disregarding the large-scale anomalies that persist at similar scales in WMAP and Planck, observations of the cosmic microwave background are largely consistent with the standard cosmological model within 2σ.

79 ASTRONOMY AND ASTROPHYSICS↗

A CORRECTION TO THE STANDARD GALACTIC REDDENING MAP: PASSIVE GALAXIES AS STANDARD CRAYONS

We present corrections to the Schlegel et al. (SFD98) reddening maps over the Sloan Digital Sky Survey (SDSS) northern Galactic cap area. To find these corrections, we employ what we call the 'standard crayon' method, in which we use passively evolving galaxies as color standards to measure deviations from the reddening map. We select these passively evolving galaxies spectroscopically, using limits on the H{alpha} and [O II] equivalent widths to remove all star-forming galaxies from the SDSS main galaxy catalog. We find that by correcting for known reddening, redshift, color-magnitude relation, and variation of color with environmental density, we can reduce the scatter in color to below 3% in the bulk of the 151,637 galaxies that we select. Using these galaxies, we construct maps of the deviation from the SFD98 reddening map at 4.{sup 0}5 resolution, with 1{sigma} error of {approx}1.5 mmag E(B - V). We find that the SFD98 maps are largely accurate with most of the map having deviations below 3 mmag E(B - V), though some regions do deviate from SFD98 by as much as 50%. The maximum deviation found is 45 mmag in E(B - V), and spatial structure of the deviation is strongly correlated with the observed dust temperature, such that SFD98 underpredict reddening in regions of low dust temperature. Our maps of these deviations, as well as their errors, are made available to the scientific community on the Web as a supplemental correction to SFD98.

79 ASTRONOMY AND ASTROPHYSICS↗

Long-term stability of the Leksell Gamma Knife{sup ®} Perfexion™ patient positioning system (PPS)

Purpose: To assess the long-term mechanical stability and accuracy of the patient positioning system (PPS) of the Leksell Gamma Knife{sup ®} Perfexion™ (LGK PFX). Methods: The mechanical stability of the PPS of the LGK PFX was evaluated using measurements obtained between September 2007 and June 2011. Three methods were employed to measure the deviation of the coincidence of the radiological focus point (RFP) and the PPS calibration center point (CCP). In the first method, the onsite diode test tool with single diode detector was used together with the 4 mm collimator on a daily basis. In the second method, a service diode test tool with three diode detectors was used biannually at the time of the routine preventive maintenance. The test performed with the service diode test tool measured the deviations for all three collimators 4, 8, and 16 mm and also for three different positions of the PPS. The third method employed the conventional film pin-prick method. This test was performed annually for the 4 mm collimator at the time of the routine annual QA. To estimate the effect of the patient weight on the performance of the PPS, the focus precision tests were also conducted with varying weights on the PPS using a set of lead bricks. Results: The average deviations measured from the 641 daily focus precision tests were 0.1 ± 0.1, 0.0 ± 0.0, and 0.0 ± 0.0 mm, respectively, for the 4 mm collimator in the X (left/right of the patient), Y (anterior/posterior of the patient), and Z (superior/inferior of the patient) directions. The average of the total radial deviations as measured during ten semiannual measurements with the service diode test tool were 0.070 ± 0.029, 0.060 ± 0.022, and 0.103 ± 0.028 mm, respectively for the central, long, and short diodes for the 4 mm collimator. Similarly, the average total radial deviations measured during the semiannual measurements for the 4, 8, and 16 mm collimators and using the central diode were 0.070 ± 0.029, 0.097 ± 0.025, 0.159 ± 0.028 mm, respectively. The average values of the deviations as obtained from the five annual film pin-prick tests for the 4 mm collimator were 0.10 ± 0.06, 0.06 ± 0.09, and 0.03 ± 0.03 mm for the X, Y, Z stereotactic directions, respectively. Only a minor change was observed in the total radial deviations of the PPS as a function of the simulated patient weight up to 202 kg on the PPS. Conclusions: Excellent long-term mechanical stability and high accuracy was observed for the PPS of the LGK PFX. No PPS recalibration or any adjustment in the PPS was needed during the monitored period of time. Similarly, the weight on the PPS did not cause any significant disturbance in the performance of the PPS for up to 202 kg simulated patient weight.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-54: A New Method for Optimizing Radiation Isocenter for Linac-Based SRS

Purpose: To develop a new method to minimize deviation of linac x-ray beams from the centroid of the volumetric radiation isocenter for all combinations of gantry and table angle. Methods: A set of ball-bearing (Winston-Lutz) images was used to determine the gantry radiation isocenter as the midrange of deviation values. Deviations in the cross-plane direction were minimized by calibration of MLC leaf position offset, and by adjusting beam position steering for each energy. Special attention was also paid to matching the absolute position of isocenter across all energies by adjusting position steering in the gun-target axis. Displacement of table axis from the gantry isocenter, and recommended table axis adjustment for contemporary Elekta linacs, was also determined. Eight images were used to characterize the volumetric isocenter for the full range of gantry and table rotations available. Tabulation of deviation for each beam was used to test compliance with isocenter tolerance. Results: Four contemporary Elekta linacs were evaluated and the radius in the gun-target axis of the radiation isocenter was 0.5 to 0.7 mm. After beam steering adjustment, the radius in the cross-plane direction was typically 0.2 to 0.4 mm. Position matching between energies can be reduced to 0.28 mm. Maximum total deviation was 0.68 to 1.07 mm, depending primarily on the effect of systematic table axis wobble with rotation. Conclusion: This new method effectively facilitates minimization of deviation between beam center and target position. The test, which requires a few minutes to perform, can be easily incorporated into a routine machine QA program. A tighter radiation isocenter for contemporary Elekta linacs would require reducing the effect of gantry arm flex and/or table axis wobble that are the two main components of deviation from the designated isocenter point.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-F-CAMPUS-T-03: Data Driven Approaches for Determination of Treatment Table Tolerance Values for Record and Verification Systems

Purpose: To determine appropriate couch tolerance values for modern radiotherapy linac R&V systems with indexed patient setup. Methods: Treatment table tolerance values have been the most difficult to lower, due to many factors including variations in patient positioning and differences in table tops between machines. We recently installed nine linacs with similar tables and started indexing every patient in our clinic. In this study we queried our R&V database and analyzed the deviation of couch position values from the acquired values at verification simulation for all patients treated with indexed positioning. Mean and standard deviations of daily setup deviations were computed in the longitudinal, lateral and vertical direction for 343 patient plans. The mean, median and standard error of the standard deviations across the whole patient population and for some disease sites were computed to determine tolerance values. Results: The plot of our couch deviation values showed a gaussian distribution, with some small deviations, corresponding to setup uncertainties on non-imaging days, and SRS/SRT/SBRT patients, as well as some large deviations which were spot checked and found to be corresponding to indexing errors that were overriden. Setting our tolerance values based on the median + 1 standard error resulted in tolerance values of 1cm lateral and longitudinal, and 0.5 cm vertical for all non- SRS/SRT/SBRT cases. Re-analizing the data, we found that about 92% of the treated fractions would be within these tolerance values (ignoring the mis-indexed patients). We also analyzed data for disease site based subpopulations and found no difference in the tolerance values that needed to be used. Conclusion: With the use of automation, auto-setup and other workflow efficiency tools being introduced into radiotherapy workflow, it is very essential to set table tolerances that allow safe treatments, but flag setup errors that need to be reassessed before treatments.

60 APPLIED LIFE SCIENCES↗

SU-F-T-640: Feasibility of Using a Commercially Available Surface Guided Radiotherapy System with An Open-Face SRS Immobilization System

Purpose: To evaluate the inherent accuracy of using a surface guided radiotherapy system (SGRT) in the setup and monitoring of patients receiving stereotactic radiosurgery with an open-face SRS immobilization system. Methods: An anthropomorphic head phantom was set up using the Qfix Encompass SRS Immobilization System on a Varian Edge with OSMS and Varian TrueBeam with AlignRT. The phantom was positioned at 0° gantry and couch. A reference image was acquired using the SGRT system and an ROI was created over the mask opening. The couch and gantry were rotated to different combinations focusing on clinically used SRS gantry/couch combinations and those blocking the SGRT cameras. Perceived surface deviation by the SGRT system from the reference image was recorded. A Winston-Lutz test was performed on couch angles tested and used to exclude couch walkout. The deviation magnitude was calculated using translational values and rotational raw values were recorded. Results: The maximum couch walkouts were: 0.4mm (Edge) and 0.5mm (TB). Solely rotating the gantry resulted in a median couch deviation of 0.2mm and range of 0.1–0.3mm for both linacs. Only rotating the couch (0° gantry) resulted in median deviations of 0.6mm and 0.5mm with ranges of 0.3–1.0mm and 0.3–0.7mm for the Edge and TB, respectively. Combining gantry and couch rotations, the median deviations were 0.7mm and 0.9mm with ranges of 0.3–1.1mm and 0.2–1.9mm for the Edge and TB, respectively. Including all combinations, rotation, roll, and pitch median deviations ranged from 0.1–0.3° with pitch demonstrating consistently higher values and a maximum deviation of 1.0° (both linacs). Conclusion: SGRT is a reliable monitoring tool, though taking into account system fluctuations, 1mm is too restrictive a site tolerance to use with the Qfix Encompass mask. Gantry rotation has little effect on system fluctuation even with camera blockage, whereas couch rotation has a larger effect.

43 PARTICLE ACCELERATORS↗

SU-G-TeP2-04: Comprehensive Machine Isocenter Evaluation with Separation of Gantry, Collimator, and Table Variables

Purpose: To develop and demonstrate application of a method that characterizes deviation of linac x-ray beams from the centroid of the volumetric radiation isocenter as a function of gantry, collimator, and table variables. Methods: A set of Winston-Lutz ball-bearing images was used to determine the gantry radiation isocenter as the midrange of deviation values resulting from gantry and collimator rotation. Also determined were displacement of table axis from gantry isocenter and recommended table axis adjustment. The method, previously reported, has been extended to include the effect of collimator walkout by obtaining measurements with 0 and 180 degree collimator rotation for each gantry angle. Twelve images were used to characterize the volumetric isocenter for the full range of available gantry, collimator, and table rotations. Results: Three Varian True Beam, two Elekta Infinity and four Versa HD linacs at five institutions were tested using identical methodology. Varian linacs exhibited substantially less deviation due to head sag than Elekta linacs (0.4 mm vs. 1.2 mm on average). One linac from each manufacturer had additional isocenter deviation of 0.3 to 0.4 mm due to jaw instability with gantry and collimator rotation. For all linacs, the achievable isocenter tolerance was dependent on adjustment of collimator position offset, transverse position steering, and alignment of the table axis with gantry isocenter, facilitated by these test results. The pattern and magnitude of table axis wobble vs. table angle was reproducible and unique to each machine. Conclusion: This new method provides a comprehensive set of isocenter deviation values including all variables. It effectively facilitates minimization of deviation between beam center and target (ball-bearing) position. This method was used to quantify the effect of jaw instability on isocenter deviation and to identify the offending jaw. The test is suitable for incorporation into a routine machine QA program. Software development was performed by Radiological Imaging Technology, Inc.

60 APPLIED LIFE SCIENCES↗

Size-resolved ice nucleating particle (INP) concentrations from the MOSAiC campaign

Sample collection: Ground-based immersion mode ice nucleation measurements were conducted on samples collected at the U.S. DOE ARM AMF2 onboard the R/V Polarstern P-deck during MOSAiC from 23 Oct 2019 to 01 Oct 2020. Samples were collected using a Davis Rotating-drum Unit for Monitoring (DRUM; DRUMAir, LLC) cascading impactor in 4 stages (i.e., size bins). Instrument information on the model used, the DA400, can be found at the DRUMAir website (http://www.drumair.com/). Stages A, B, C, and D had particle size cuts at 2.96, 1.21, 0.34, and 0.15 &micro;m in particle diameter, respectively. Strips of sample substrate (PFA, perfluoroalkoxy; McMaster) were adhered to each disc in each stage and coated with petrolatum to enable particles to stick on impact. The discs move slowly over time, such that aerosol loading is streaked onto the PFA. Every 24 hours, a blank is created on the PFA to separate daily samples. During MOSAiC, the pump typically pulled 20 &ndash; 35 lpm (average of 32 lpm) at the inlet with all the discs in place in each stage. Daily samples were collected for each of the four stages, equaling 28,800 &ndash; 50,400 total L of air (average of 46,080 L total L of air) per sample. Discs rotated for approximately 24 days before the sampling per strip was complete and changed to a new disc. Discs were stored frozen after collection. Sample preparation for analysis: Following collection and transport from MOSAiC to the Kreidenweis/DeMott laboratory, care of PI Creamean, in Fort Collins, CO, strips were removed from the discs and cut up to separate daily samples. Each daily portion of the strip was stored in separate sterile 15-mL centrifuge tubes and stored in a standard commercial freezer until analysis (approximately 4 &ndash; 12 months after collection). Sample analysis: Drop freezing assays (DFAs) were conducted on one daily sample set every 3 &ndash; 4 days of the study for all four stages using the Colorado State University (CSU) cold plate (CP). Sample set days were chosen to cover the entire year of MOSAiC and avoiding days where the AOS purge system was activated. Immediately after removal from the freezer, 2 mL of 0.1-&micro;m filtered deionized water was added with a single-use sterile syringe directly to the tubes, then mixed using a vortex mixer for at least 30 minutes at 500 rpm to resuspend particles from the PFA into the deionized water. Following sample preparation, another single-use syringe was used to create 100 aliquots on a 3-inch diameter copper plate, then covered with a transparent plastic dome. The drops were approximately the same volume (2.5 &micro;L each), though careful inspection. The plate was cooled at approximately 3 &ndash; 10 K min-1 from room temperature until all drops froze on the plate. Temperature was measured by an Omega thermocouple probes and meter. Drop freezing was visually detected but recorded through monitoring software to provide the time frozen, channel of the meter used, temperature, and cooling rate for each drop. Not all 100 drops were always detected; the total number of rows in each data file equals the number of drops recorded, which typically was > 80 %. Each sample was tested three times (i.e., a new set of 100 drops was created for each test). Data provided are files containing these parameters. From the freezing temperatures recorded, the fraction frozen was and INP concentrations were calculated per L of air using the equation from Vali (1971): [INPs] = &minus;(ln(f)/Valiquot)*(Vsuspension/Vair) where f is the proportion of droplets not frozen, Valiquot is the volume of each aliquot (i.e., 2.5e-6 L), Vsuspension is the volume of the suspension (i.e., 0.002 L), and Vair is the volume of air per sample (i.e., 36000 L). Data usage guidance: There are three files included with this dataset: (1) dumcp_inp_concentrations.csv which includes cumulative INP concentrations binned every 0.5 &deg;C from 0 to &ndash;30 &deg;C for all samples and size ranges (i.e., DRUM stages) processed via DFA using the CSU CP; (2) dumcp_inp_standard_deviation.csv which includes the standard deviations for all samples and temperatures in dumcp_inp_concentrations.csv; and (3) dumcp_blank_concentrations_standard_deviation.csv which includes the INP concentrations and standard deviations for the deionized water and PFA blanks binned every 0.5 &deg;C from 0 to &ndash;30 &deg;C. The first column in each file represents the freezing temperature in &deg;C binned every 0.5 &deg;C from 0 to &ndash;30 &deg;C (first cell in this column = header = &ldquo;temp&rdquo;). The second column in each file represents the standard deviation of each temperature bin in &deg;C (first cell in this column = header = &ldquo;temperr&rdquo;). For file (1) dumcp_inp_concentrations.csv, the remaining columns indicate the INP concentrations per L of air for each temperature bin. For each sample column, the header in the first row indicates the stage (i.e., size bin as &ldquo;A_&rdquo;, &ldquo;B_&rdquo;, &ldquo;C_&rdquo;, or &ldquo;D_&rdquo;) and date (&ldquo;_yyyymmdd) of collection. For file (2) dumcp_inp_standard_deviation.csv, the remaining columns indicate the INP concentration standard deviation per L of air for each temperature bin. For each sample column, the header in the first row indicates the stage (i.e., size bin as &ldquo;A_&rdquo;, &ldquo;B_&rdquo;, &ldquo;C_&rdquo;, or &ldquo;D_&rdquo;) and date (&ldquo;_yyyymmdd) of collection. For file (3) dumcp_blank_concentrations_standard_deviation.csv, the remaining columns indicate the INP concentrations and standard deviations for the deionized water blank (&ldquo;di_0.1&rdquo; and &ldquo;di_0.1sd&rdquo; for the concentrations and standard deviations, respectively) and PFA blank (&ldquo;pfa&rdquo; and &ldquo;pfasd&rdquo; for the concentrations and standard deviations, respectively). Please see Creamean et al. (2019a; 2018a; 2018b; 2019b) for additional details on DRUM sample collection and offline processing. For questions or help with data interpretation, contact Dr. Jessie Creamean (jessie.creamean@colostate.edu). References: Creamean, J. M., Mignani, C., Bukowiecki, N., and Conen, F.: Using spectra characteristics to identify ice nucleating particle populations during winter storms in the Alps, Atmos. Chem. Phys., 19, 8123&ndash;8140, 2019a. Creamean, J. M., Kirpes, R. M., Pratt, K. A., Spada, N. S., Maahn, M., de Boer, G., Schnell, R. C., and China, S.: Marine and terrestrial influences on ice nucleating particles during continuous springtime measurements in an Arctic oilfield location, Atmospheric Chemistry and Physics, 18, 18023-18042, 10.5194/acp-18-18023-2018, 2018a. Creamean, J. M., Primm, K. M., Tolbert, M. A., Hall, E. G., Wendell, J., Jordan, A., Sheridan, P. J., Smith, J., and Schnell, R. C.: HOVERCAT: A novel aerial system for evaluation of aerosol-cloud interactions, Atmospheric Measurement Techniques, 11, 3969-3985, 10.5194/amt-11-3969-2018, 2018b. Creamean, J. M., Cross, J. N., Pickart, R., McRaven, L., Lin, P., Pacini, A., Hanlon, R., Schmale, D. G., Ceniceros, J., Aydell, T., Colombi, N., Bolger, E., and DeMott, P. J.: Ice nucleating particles carried from below a phytoplankton bloom to the Arctic atmosphere, Geophys. Res. Lett., 46, 8572-8581, https://doi.org/10.1029/2019GL083039, 2019b. Vali, G.: Quantitative Evaluation of Experimental Results an the Heterogeneous Freezing Nucleation of Supercooled Liquids, Journal of the Atmospheric Sciences, 28, 402-409, 10.1175/1520-0469(1971)028<0402:qeoera>2.0.co;2, 1971.

4-stage DRUM aerosol collector (DA400),Ice nuclei,↗

EPCAPE-PT-LANL Measurements: Single Particle Soot Photometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Single Particle Soot Photometer (Droplet Measurements Technology) Data Notes: Contact us if you want additional data products from this instrument. Reported data is the black carbon (rBC) number and mass concentration with diagnostic flags. The SP2 measures incandescence from particles that is induced with a 1064 Nd-YAG laser. Particles that absorb the laser energy and then emit radiation is assumed to contain black carbon. The amount of intensity of radiation is related to the mass of absorbing material in the particle. Here, we calibrate the incandescence intensity to size selected Regal Black (Cabot) nebulized from solution. Data provided for the EPCAPE campaign used the combined broadband high-gain + low-gain channels (BHBL). Each channel has a lower threshold of detection equivalent to 2-s of the respective channel noise. Thresholding has been applied to select between the high-gain and low-gain channels. The detection limit is 80-540 nm (Deq) or 0.36- 55 fg. It is assumed that rBC is the only aerosol type that is in significant concentration in the sampled atmosphere that absorbs the laser energy. Particle data are integrated over 10 second windows to calculate a rBC number and mass concentration. QC/QA: • Diagnostic flags that impacted measured concentration: - Sample, Sheath, and Purge Flow Rates: Despite observing fluctuations in all flows, the rBC detection and mass quantification are generally observed to be stable, although large changes in sample flow rate did impact detection efficiency. A flag was implemented for sample flow deviations >12 cm3/min from the set point averaged over 30 seconds - Laser Power: Detection efficiency decreases with laser power and deviations in laser power also affect mass quantification. Flag for laser power is set for deviations in laser current from the set value >5 mA. - Primary Detector Threshold: Primary thresholding is the signal value which determines whether a “particle” is recorded. Thresholding errors occur when the threshold value is too HIGH and real particles are ignored. • Several periods without data: - 16-18 Nov: Ultra Zero Air generator failure, flows deviated significantly from set points. rBC # conc recovered but questionable. - 20-21 Nov: Offline for calibrations for several hours each day. - 25-27 Nov: Data is missing. - 30 Nov: Power outage 3 Dec: SP2 hard-drive full. - 3 Dec: Power Outage Header: - BHBL_NumbConc[#/cc]: Refers to the number concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in particles per cubic centimeter. - BHBL_BCMass_Conc[ug/m3]: Refers to the mass concentration of refractory black carbon (rBC) measured from combined broadband high-gain and low-gain channels, expressed in micrograms per cubic meter. - NoData_Flag[bool]: A boolean flag that indicates whether no data was recorded during a measurement. - NoBC_Flag[bool]: A boolean flag indicating whether no black carbon particles were recorded during the measurement. - Laser_Flag[bool]: A boolean flag indicating deviations in laser current during the measurement. - SampleFlow_Flag[bool]: A boolean flag indicating deviations from the set sample flow rate during the measurement. - PrimThresh_Flag[bool]: A boolean flag indicating deviations from the set primary threshold during the measurement, potentially ignoring real particles. - Manual_Flag[bool]: A boolean flag indicating manual intervention or adjustments during the measurement. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active or inactive during the measurement.

54 ENVIRONMENTAL SCIENCES↗

Study of (W/Z)H production and Higgs boson couplings using H→ W W * decays with the ATLAS detector

A search for Higgs boson production in association with a W or Z boson, in the H→ W W * decay channel, is performed with a data sample collected with the ATLAS detector at the LHC in proton-proton collisions at centre-of-mass energies \( \sqrt{s}=7 \) TeV and 8 TeV, corresponding to integrated luminosities of 4.5 fb -1 and 20.3 fb -1 , respectively. The WH production mode is studied in two-lepton and three-lepton final states, while two- lepton and four-lepton final states are used to search for the ZH production mode. The observed significance, for the combined W H and ZH production, is 2.5 standard deviations while a significance of 0.9 standard deviations is expected in the Standard Model Higgs boson hypothesis. The ratio of the combined W H and ZH signal yield to the Standard Model expectation, μ V H , is found to be μ V H = 3.0 -1.1 +1.3 (stat.) -0.7 +1.0 (sys.) for the Higgs boson mass of 125.36 GeV. The W H and ZH production modes are also combined with the gluon fusion and vector boson fusion production modes studied in the H → W W * → ℓνℓν decay channel, resulting in an overall observed significance of 6.5 standard deviations and μ ggF + VBF + VH = 1.16 -0.15 +0.16 (stat.) -0.15 +0.18 (sys.). The results are interpreted in terms of scaling factors of the Higgs boson couplings to vector bosons (κ V ) and fermions (κ F ); the combined results are: |κ V | = 1.06 -0.10 +0.10 , |κ F | = 0.85 -0.20 +0.26 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Reduction of baseplate distortion during directed energy deposition using compliant features

Distortion in additive manufacturing (AM) remains a barrier to its adoption in precision industries. Baseplate warpage is one such issue which compromises the feasibility of post-process precision machining. The restriction to thermal contraction of the deposited part, imposed by the baseplate, generates bending moments, that in turn causes warpage. A novel distortion mitigation strategy using baseplates with integrated compliant features, which enables thermal contraction of the build is presented. Six unique design concepts are evaluated, including a solid reference, using two deposition geometries. A laser, hot-wire, directed energy deposition (DED) process is used to deposit a symmetric cylindrical part (C-part) and a T-shaped asymmetric part (T-part). Flatness deviation of baseplates is measured using structured light 3D scanning. Measurements reveal a reduction in net flatness deviation of 58.8% for the C-part and 40.9% for the T-part, compared to the solid reference. While most designs yielded reductions exceeding 30% and 20% for the C- and T-parts, respectively, one configuration resulted in increased deviation. Finite element (FE) simulations are performed to elucidate the underlying mechanisms affecting distortion of compliant baseplates during DED. Despite variations between predictions and measurements, agreement in the general trend is observed. It also revealed that initial flatness errors in baseplates significantly affect its deviation during deposition. Predictions indicate that compliant features significantly affect the thermal distribution as well as the evolution of flatness deviation in the baseplate during deposition. Notably, one design exhibited a reduction in distortion during cooling, following its initial increase during deposition. FE predictions show a maximum reduction of 60.9% and 38.8% in net flatness deviation for the C- and T-parts, respectively. The performance of compliant baseplates is found to be governed by both its the thermal and mechanical characteristics, which are crucial factors to be considered during design.

Mathews, Ritin [ORNL] (ORCID:0000000301440828)↗

Megavoltage Computed Tomography Image Guidance With Helical Tomotherapy in Patients With Vertebral Tumors: Analysis of Factors Influencing Interobserver Variability

Purpose: To evaluate megavoltage computed tomography (MVCT)-based image guidance with helical tomotherapy in patients with vertebral tumors by analyzing factors influencing interobserver variability, considered as quality criterion of image guidance. Methods and Materials: Five radiation oncologists retrospectively registered 103 MVCTs in 10 patients to planning kilovoltage CTs by rigid transformations in 4 df. Interobserver variabilities were quantified using the standard deviations (SDs) of the distributions of the correction vector components about the observers' fraction mean. To assess intraobserver variabilities, registrations were repeated after {>=}4 weeks. Residual deviations after setup correction due to uncorrectable rotational errors and elastic deformations were determined at 3 craniocaudal target positions. To differentiate observer-related variations in minimizing these residual deviations across the 3-dimensional MVCT from image resolution effects, 2-dimensional registrations were performed in 30 single transverse and sagittal MVCT slices. Axial and longitudinal MVCT image resolutions were quantified. For comparison, image resolution of kilovoltage cone-beam CTs (CBCTs) and interobserver variability in registrations of 43 CBCTs were determined. Results: Axial MVCT image resolution is 3.9 lp/cm. Longitudinal MVCT resolution amounts to 6.3 mm, assessed as full-width at half-maximum of thin objects in MVCTs with finest pitch. Longitudinal CBCT resolution is better (full-width at half-maximum, 2.5 mm for CBCTs with 1-mm slices). In MVCT registrations, interobserver variability in the craniocaudal direction (SD 1.23 mm) is significantly larger than in the lateral and ventrodorsal directions (SD 0.84 and 0.91 mm, respectively) and significantly larger compared with CBCT alignments (SD 1.04 mm). Intraobserver variabilities are significantly smaller than corresponding interobserver variabilities (variance ratio [VR] 1.8-3.1). Compared with 3-dimensional registrations, 2-dimensional registrations have significantly smaller interobserver variability in the lateral and ventrodorsal directions (VR 3.8 and 2.8, respectively) but not in the craniocaudal direction (VR 0.75). Conclusion: Tomotherapy image guidance precision is affected by image resolution and residual deviations after setup correction. Eliminating the effect of residual deviations yields small interobserver variabilities with submillimeter precision in the axial plane. In contrast, interobserver variability in the craniocaudal direction is dominated by the poorer longitudinal MVCT image resolution. Residual deviations after image guidance exist and need to be considered when dose gradients ultimately achievable with image guided radiation therapy techniques are analyzed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗