Search NASA⌕ Search

SEARCH · Search NASA

Results for “diameter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Recent progress in shattered pellet injection technology in support of the ITER disruption mitigation system*

Shattered pellet injection (SPI) has been selected as the baseline technology for the disruption mitigation (DM) system for ITER. Typical SPI utilizes cryogenic cooling to desublimate low pressure (<100 mbar) gases onto a cold zone within a pipe gun barrel, forming a cylindrical pellet. Pellets are dislodged from the barrel and accelerated using either a gas driven mechanical punch or high-pressure light-gas delivered by a fast-opening valve. SPI technology developed at Oak Ridge National Laboratory is currently deployed and operational on DIII-D, JET, and KSTAR. These SPI systems are used in experiments for physics scaling to ITER thermal mitigation and runaway electron dissipation/avoidance. The pellet sizes used for these machines are in the range of 4 to 12.5 mm in diameter with length to diameter ratios (L/D) of ~1.5. The current plan for ITER SPI is to utilize pellets that are 28.5 mm in diameter with an L/D of ~2. Furthermore, the large pellet sizes, high steady-state magnetic fields, and limitations of operating in a radiation environment render much of the current technology unusable. In addition to technology improvements, a deeper understanding of pellet material properties, formation, and release is being developed for implementation in future SPI designs, specifically ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rapid approach for structural design of the tower and monopile for a series of 25 MW offshore turbines

The goal of further reducing the Levelized Cost of Energy (LCOE) has driven the investigation of large-scale wind turbines. This work presents a simple, rapid and detailed approach for the structural design of the tower and monopile without a controller, but with frequency and high fidelity structural verification. The approach uses an optimization to reduce the mass of the structures while meeting strength, buckling and geometric constraints by using analytical equations. A verification of frequency constraints is performed with BModes, and ANSYS Mechanical APDL is used for high fidelity verification of stress and buckling. The approach is applied to study the design space of three 25 MW offshore wind turbines with different rotor diameters and cone angles, and to evaluate the nacelle center of mass fore-aft location effect. Results obtained show that the tower and monopile are more susceptible to changes in the rotor thrust than the overturning moment even for designs with high pre-cone angle and large distance of the nacelle center of mass from the tower axis. But it is possible to obtain structurally feasible tower and monopile designs for the three 25 MW turbines studied while not exceeding diameter and wall thickness limits. However, mass penalties can be decreased by 0.8-14%, to further reduce the cost of energy, by increasing the diameter limit which may require manufacturing technology development. The approach applied and studies serve to understand the design space of the tower and monopile for a 25 MW turbine, and provide baseline designs that can be used in the development of a controller and evaluation of a full suite of design load cases.

17 WIND ENERGY↗

Performance of the wavelength-shifting fiber upgrade for the Mu2e cosmic-ray veto detector

The Cosmic-Ray Veto detector for the muon-to-electron conversion experiment at Fermilab consists of four plastic scintillating counter layers read out by silicon photo-multipliers through embedded wavelength-shifting fibers. In order to increase the light yield in the most critical regions of the Cosmic-Ray Veto detector for improved background rejection, a 1.8 mm diameter fiber is being used in many of the detector's critical modules instead of the previously planned 1.4 mm diameter fiber. This paper reports the testing procedure and light properties of thirty-four 1.8 mm fiber spools, with measurements performed using a custom-built scanner. We compare these new results with previously published data from the 1.4 mm diameter fiber used for regions of the cosmic-ray veto where the increased light yield is not required. In addition, measurements of fiber aging were performed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic aspects of a 20 MW class low-temperature superconducting generator for the renewables industry

In this paper we give a progress update on the cryogenic design for cooling a 20 MW class, partially superconducting generator with stationary field coils for offshore wind renewables industry [1-2]. This is a continuation of an earlier program on a 10 MW system dating back ten years. Whereas this new power rating increase leads to a radial diameter expansion of the superconducting field coils from 4 to > 9.5 m, it maintains the axial length. We show the design based on this scaled up with enlarged diameter. The field coil size increase asks for higher cooling power that leads to a bigger cold box size to accommodate the cryocoolers. In the design, as many as 8 cryocoolers can be accessed and serviced from the nacelle that houses the main cryogenic components. A typical thermal load balance sheet with all components is given and compared against the available cryocooler cooling power at different operating conditions. Due to the cryocoolers’ local point of contact cooling within the nacelle, the temperature gradient of the thermal shield that fully encloses the cold mass with its embedded field coils needs to be balanced out to minimize the heat burden on the field coils. This requires additional analytical efforts and implementation of further design features. The extended nacelle houses the cold box with its cryogenic infrastructure. The interface for the envisaged cryogenic pushbutton closed-loop circulating system remains invisible, requires no handling of cryogenic liquids and is hermetically closed. The field coil diameter increase also leads to a greater initial helium gas storage volume. In addition, it requires higher initial room temperature fill pressure within the toroidal helium vapor storage tanks and in cooling tubes connecting to the cryocoolers. The toroidal helium gas tanks are thermally coupled with the thermal shield so that helium convection inside the storage tank can improve heat transfer and reduce the temperature gradient of the thermal shield. Besides those heat transfer challenges, additional mechanical strain within this large structure is exerted on the torque tubes during initial cooldown and when energizing field coils. Some of those design challenges are quite unexpected, leading to novel workarounds in order to maintain the chosen cooling strategy. Finally, we assess those design limitations in view of further cryogenic scalability with emphasis on manufacturability and assembly.

cryogenics↗

Voltage-Current Behavior of a Superconducting STAR ® Wire in a 6-Around-1 Cable Configuration

A 6-around-1 transposed cable using superconducting STAR® wires can be useful for future circular collider applications. We made three cable samples using single STAR® wires with a diameter of 1.3 mm. The first two samples, made with a cabling machine, used STAR® wires consisting of a 0.7 mm diameter Nb-Ti core. The third cable sample was manually wound and used a STAR® wire made with a 0.81 mm diameter Cu core. The first sample showed severe degradation after the cable was bent to a 75 mm radius. The current-carrying capability of the innermost and outermost REBCO tapes in the STAR® wire degraded by 42% to 98% and the middle REBCO tapes remained intact. This was also the case for the second and straight cable sample. After fabrication of the third cable sample, we observed only about 5% reduction in the current along the wire, measured at different locations inside the terminations. Finally, the results indicate that the differences in architecture or fabrication of the STAR® wires could have caused differences in critical current retention after cabling.

6-around-1 cable↗

Size effects in 3D–printed polymer–derived, zirconium diboride–reinforced ceramic composites

Preceramic polymers are of interest for use in many manufacturing techniques such as injection molding, ceramic fiber infiltration, and additive manufacturing. However, off-gassing of low molecular weight oligomers occurs when these polymers cure, potentially leading to porosity in the cured part. Here to study how porosity and strength are affected by the size of the printed part, and the presence of a high surface area nano-scale filler, polycarbosilane (PCS) microrods of varying diameter were fabricated via direct ink writing (DIW), an additive manufacturing technique, with two ink formulations containing either zirconium diboride (ZrB 2 ) alone, or ZrB 2 and fumed alumina (FA). Sets of microrods were printed in a range of sizes by using print nozzles of 450, 634, 979, 1 346, or 1 702 μm in diameter, which were thermally cured, pyrolyzed to form ceramic composite microrods, and tested in 3-pt flexure. Porosity increased with increasing diameter, while failure strength decreased. For a given nozzle size, the microrods containing FA displayed lower porosity and higher strength (up to ~500 MPa) compared to the microrods containing only ZrB 2 . Weibull strength analysis was performed on each group of microrods and shows that the addition of FA increased Weibull modulus from 4.63 ± 1.56 to 9.35 ± 0.601. In conjunction with optical microscopy, this analysis indicates two distinct flaw populations in the printed materials, porosity which arises during the curing step and cracking which arises during pyrolysis of the larger specimens.

36 MATERIALS SCIENCE↗

A strain density function to analyze particle size effects during high velocity impacts of yttria

Here, the impact behavior of a single yttria (Y 2 O 3 ) nanoparticle onto a Y 2 O 3 substrate is studied as a function of particle velocity (300–1200 m/s) and diameter (12–50 nm) using molecular dynamics simulations. To analyze the results, a strain density function is developed to provide both quantitative and qualitative information about the deformation mechanisms that contribute to the final state of the system. This function provides both clear evidence of shear localization and insight into the conditions for which localization occurs during the impact of Y 2 O 3 particles as they approach experimentally relevant sizes. Further analysis shows that localization and fragmentation only occur for Y 2 O 3 impacts with diameters of at least 50 nm, while particles with diameters of 25 nm and smaller deform primarily by amorphization and viscous flow. Implications for the deposition of films of Y 2 O 3 and other rare-earth oxides via the micro cold spray process are discussed.

36 MATERIALS SCIENCE↗

Experimental Study on Flow Behavior and Heat Transfer Enhancement With Distinct Dimpled Gas Turbine Blade Internal Cooling Channel

Abstract The study presents the investigation on heat transfer distribution along a gas turbine blade internal cooling channel. Six different cases were considered in this study, using the smooth surface channel as a baseline. Three different dimples depth-to-diameter ratios with 0.1, 0.25, and 0.50 were considered. Different combinations of partial spherical and leaf dimples were also studied with the Reynolds numbers of 6,000, 20,000, 30,000, 40,000, and 50,000. In addition to the experimental investigation, the numerical study was conducted using a large eddy simulation (LES) to validate the data. It was found that the highest depth-to-diameter ratio showed the highest heat transfer rate. However, the deepest dimpled channel shows the highest pressure drop, which affects the overall thermal performance of the cooling channel. The results showed that the leaf dimpled surface is the best cooling channel based on the highest Reynolds number's heat transfer enhancement and friction factor. However, at the lowest Reynolds number, partial spherical dimples with a 0.25 depth-to-diameter ratio showed the highest thermal performance.

Energy & Fuels↗

Computational Modeling of Multi-Pass Rolling Parameters Effect on Resulting Fuel Foil Shape

A focus of the U.S. Department of Energy is to improve production yield and reduce the cost of Low Enriched Uranium (LEU)-molybdenum alloy (U-10Mo) monolithic fuel plates that will be replacing High Enriched Uranium (HEU) oxide dispersion fuels used currently in the United States High Performance Research Reactors (USHPRR). One area of improvement is lowering the high transverse waviness and longitudinal waviness currently present within rolled foils prior to cladding to produce fuel plates. Traditional rolling manufacturing techniques for other metal foils use winders to pull and straighten the foil as it is rolled back and forth to the final thickness. This approach cannot be used to roll thin U-10Mo foils (0.008-0.025” thick) because only small castings can be rolled due to nuclear criticality safety concerns. As a result, the fuel foils are too short (1 m in length) to use traditional winders. Therefore, it is crucial to identify other rolling parameters (i.e., roller friction, axial tension load, roller diameter, and roll pass reduction percent) that might reduce transverse waviness and longitudinal waviness in the rolled fuel foil and develop a high-yield, low-cost multi-pass rolling manufacturing process. This report documents a systematic finite element modeling study to investigate the effects of numerous rolling parameters to reduce resulting transverse waviness and longitudinal waviness in the fuel foil during multi-pass rolling of U-10Mo foils. The rolling of a U-10Mo plate with initial dimensions of 1”x1”x 0.048” is modeled using Abaqus CAE. This rolling is modeled to undergo eight 20% reduction roll passes to a final fuel foil thickness of 0.01”. The elastic-plastic constitutive model of the U-10Mo alloy was input to the fuel foil rolling model. The rollers were modeled as rigid bodies. A comparison of rolling friction coefficients of 0.3 and 0.7 over a wide range of applied axial tension loads were investigated in order to evaluate the effect of using a lubricant during rolling. The effect of roller diameter on the resulting transverse waviness and longitudinal waviness of the fuel foil over a wide range of axial tension loads were also investigated by modeling rollers 7/8” and 3.75” in diameter. The results of this systematic finite element method study will aid manufacturers in producing low transverse waviness and reduced longitudinal waviness in U-10Mo fuel foils.

U-10Mo, FEA, Rolling, Residual Stress, Fuel Foil↗

Etching sharp tips from thin metallic wires for tuning-fork-based scanning probe microscopy

Sharp tips are critical for obtaining high resolution images in scanning probe microscopy (SPM), particularly in samples with large variations in topography. For tuning-fork-based SPM, such tips are commonly obtained by electrochemical etching of metallic wires (e.g., tungsten). Electrochemical etching of metallic wires is the preferred means of preparing tips for scanning tunneling microscopy (STM), and techniques for obtaining sharp tips have been investigated extensively. However, the requirements for STM and tuning-fork-based SPM are different. In particular, the wires used in STM are typically 250-500 μ m in diameter, while the wires used for tuning-fork-based SPM are usually an order of magnitude narrower in order to minimize loading of the tuning fork: 25-50 μ m and sometimes down to a few micrometers in diameter. Consequently, many of the recipes developed for etching thicker metallic wires for STM tips do not give optimal results for smaller diameter wires. The authors describe here a modification of the etching circuit of Ibe et al . that significantly improves the reproducibility and reliability of the etching process for thin wires, and discuss the parameters that affect the aspect ratio of produced tips.

42 ENGINEERING↗

Design, performance, and field operation of twisting heliostats for 3,000-sun concentration and high temperature

The idea is to combine the solar energy reflected from a field of many heliostats to obtain a single focus of high concentration and high power. We exploit a new type of “twisting” heliostat” in which as the mount is moved to track the sun through the day, the reflector shape is twisted to maintain a focused image of the sun’s disc on the target, through the day over a wide range of angles of incidence. By combining the light reflected by many twisting heliostats into a single focus, we are not only able to accomplish but also maintain very high concentration and temperature through the day, with higher efficiency than has previously been possible with conventional heliostats having a fixed shape. A circular field of twisting heliostats is used to power a single intense focus atop a central tower. The light from all the heliostats is relayed to an upward facing receiver at the focus via a central Cassegrain secondary reflector located above the receiver. In a specific design targeting 1 MW of power, a 100 m diameter field arrays 431 twisting heliostats, each with a 7 m2 reflector. The secondary reflector ,7.2 m in diameter, is located 24 m above the heliostat field, bringing sunlight with annual average power of 1 MW to a circular focus 0.8 m in diameter, at a concentration averaging 3,000 suns.

14 SOLAR ENERGY↗

Field study of group effects on the pullout capacity of “deep” helical piles in sand

This paper presents the results of a field load test program used to investigate group effects on the pullout capacity of single-helix “deep” helical piles/anchors in sand. The high tensile capacity and silent installation of helical piles has given them serious consideration as an alternative to conventional deep foundations and anchors for offshore renewable energy structures. New offshore applications may consider the use of groups of helical piles to resist structural loads. Group interaction effects are known to occur in helical piles, but there is a scarcity of field data on groups in sands under tensile loading. This study involved the installation and load testing of single-helix 152mm diameter round shaft piles and pile groups embedded in sand to depths of 12 and 18 helix diameters below the ground surface. The study was designed to explore the effects of close pile spacing, group configuration (i.e., number of piles), and soil strength (i.e., friction angle) as interpreted from cone penetration test (CPT) resistance. The results showed group efficiencies ranging from about 0.6 to 1.0 at a horizontal spacing of 2 to 3 times the helix diameter in sands with friction angles of about 39° to 44°. The data from this study may also be useful for validation of numerical models for analysis of helical pile group interactions.

Engineering↗

Antibacterial activity of iron oxide, iron nitride, and tobramycin conjugated nanoparticles against Pseudomonas aeruginosa biofilms

Novel methods are necessary to reduce morbidity and mortality of patients suffering from infections with Pseudomonas aeruginosa. Being the most common infectious species of the Pseudomonas genus, P. aeruginosa is the primary Gram-negative etiology responsible for nosocomial infections. Due to the ubiquity and high adaptability of this species, an effective universal treatment method for P. aeruginosa infection still eludes investigators, despite the extensive research in this area. Results We report bacterial inhibition by iron-oxide (nominally magnetite) nanoparticles (NPs) alone, having a mean hydrodynamic diameter of ~ 16 nm, as well as alginate-capped iron-oxide NPs. Alginate capping increased the average hydrodynamic diameter to ~ 230 nm. We also investigated alginate-capped iron-oxide NP-drug conjugates, with a practically unchanged hydrodynamic diameter of ~ 232 nm. Susceptibility and minimum inhibitory concentration (MIC) of the NPs, NP-tobramycin conjugates, and tobramycin alone were determined in the PAO1 bacterial colonies. Investigations into susceptibility using the disk diffusion method were done after 3 days of biofilm growth and after 60 days of growth. MIC of all compounds of interest was determined after 60-days of growth, to ensure thorough establishment of biofilm colonies. Conclusions Positive inhibition is reported for uncapped and alginate-capped iron-oxide NPs, and the corresponding MICs are presented. We report zero susceptibility to iron-oxide NPs capped with polyethylene glycol, suggesting that the capping agent plays a major role in enabling bactericidal ability in of the nanocomposite. Our findings suggest that the alginate-coated nanocomposites investigated in this study have the potential to overcome the bacterial biofilm barrier. Magnetic field application increases the action, likely via enhanced diffusion of the iron-oxide NPs and NP-drug conjugates through mucin and alginate barriers, which are characteristic of cystic-fibrosis respiratory infections. We demonstrate that iron-oxide NPs coated with alginate, as well as alginate-coated magnetite–tobramycin conjugates inhibit P. aeruginosa growth and biofilm formation in established colonies. We have also determined that susceptibility to tobramycin decreases for longer culture times. However, susceptibility to the iron-oxide NP compounds did not demonstrate any comparable decrease with increasing culture time. These findings imply that iron-oxide NPs are promising lower-cost alternatives to silver NPs in antibacterial coatings, solutions, and drugs, as well as other applications in which microbial abolition or infestation prevention is sought.

Biotechnology & Applied Microbiology↗

Enhanced lightning strike protection using vertically oriented carbon fiber melded with conventional carbon fiber-reinforced composite and its validation through damage analysis

Lightning strike protection (LSP) is one of the prime factors in aerospace and wind industries concerning safety, enhanced service life, and reduced downtime. To ensure better LSP, high electrical conductivity is required to dissipate the current, which is always a challenge for polymer composites due to the inherent insulating nature of the polymer matrix. Conventional carbon fiber-reinforced composites (CFRP) offer electrical conductivity in the planar direction while the vertical i.e. through-thickness conductivity still remains a challenge. Having been motivated by this fact, we have fabricated CFRP interleaved with vertically oriented CF (Z-fiber) for the lightning strike test (100 kA). A paint was applied to mimic the actual service condition of the composite laminates. We have prepared two Z-fiber composites: (a) Z-1 containing one Z-fiber layer on the top along with conventional CF layers and (b) Z-5 containing five interleaved Z-fiber layers and compared the properties with conventional CFRP (Z-0). Interestingly, even a single Z-fiber layer (Z-1) showed lower damage (visual damage diameter 22 mm) than Z-0 (visual damage diameter 26 mm). Z-5 displayed the lowest damage (visual damage diameter 16.7 mm), which was further confirmed by cross-sectional optical microscopy. Improved LSP was attributed to the higher through-thickness electrical conductivity in the case of Z-5 (9 times with respect to Z-0) reflecting a lower electrical anisotropy for Z-fiber composites. The residual mechanical property after the lightning test was analyzed through the flexural test, and the retention of flexural strength and modulus was 66% and 86%, respectively for Z-5 showing a significant improvement in comparison to Z-0 (>40% for both).

Saha, Subhabrata↗

Effect of workpiece curvature on the tool influence function during hemispherical sub-aperture tool glass polishing

The influence of workpiece curvature on the tool influence function spot during polishing of fused silica glass with cerium oxide slurry, while using a rotating hemispherical pad-foam tool for a wide variety of process conditions (tool displacement, inclination angle, and rotation rate), has been investigated. (Workpiece curvature ranged from 500 mm radius concave to 43 mm radius convex.) The TIF spot decreases in diameter and increases in the peak removal rate on more convex workpieces. In contrast, the TIF spot increases both in diameter and peak removal rate on more concave workpieces. For the range of workpiece curvatures investigated, both the spot size and the peak removal rate changed significantly, as much as 2 times. An elastic sphere–sphere contact mechanics model, which utilizes both a modified displacement (that leads to a change in the applied load) as well as a mismatch factor (that influences the pressure distribution shape), has been developed. Furthermore, the model was validated using both offline load-displacement measurements and finite-element analysis simulations. The model quantitatively describes the measured change in the relative contact diameter and relative pressure distribution, as well as semiquantitively describes the change in the relative volumetric removal rate on a large variety of TIF spots. The change in the volumetric removal rate for convex workpieces is a result of the balance between a decreasing spot size (reducing removal) and an increasing peak pressure (increasing removal), which usually results in relatively small changes in volumetric removal. In the case of concave workpieces, the volumetric removal rate change is also governed by a similar balance, but the spot size increase contribution dominates, resulting in a significant increase in volumetric removal rate. Understanding these trends can enable methods to add greater determinism during the fabrication of freeform optics by adjusting polishing parameters (such as dwell time) while the tool translates along a workpiece surface with different local curvatures.

47 OTHER INSTRUMENTATION↗

UNH TDP - Concurrent Measurements of Inflow, Power Performance, and Loads for a Grid-Synchronized Vertical Axis Cross-Flow Turbine Operating in a Tidal Estuary

This data was collected between October 12 and December 15 of 2021 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). This data set includes over 29 days of grid connected turbine operation during this 65 day time frame. The priority for this measurement campaign was to collect data while the turbine was electrically connected to the grid by means of a rectifier and inverter. The Fall_2021_UNH_Measurement_Timeline.png highlights when each instrument was functioning and the Fall_2021_UNH_Test_Log.jpg indicates the four main regions for analysis available from this measurement campaign. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal forcing with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Kaelin Chancey (Assessment Of The Localized Flow And Tidal Energy Conversion System At An Estuarine Bridge - UNH MS Thesis 2019). The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. This project was pursued to quantify device performance for cross flow turbines operating in a marine environment. Accurate physical models, to characterize cross flow turbine performance, require real operational data sets due to the complexity of blade fluid interactions. This data can help support model development which will help predict turbine performance when analyzing perspective project locations in the future. Instrumentation was deployed to measure; water speed/direction, electrical power output, turbine shaft speed, turbine thrust force, and platform motion. Concurrent measurements of these parameters allow for correlations (cause and affect) to be inferred, allowing for characterization of device performance over a range of operating conditions. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) directly upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier and the Shark power meter. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. This submission includes zipped folders for each instrument containing quality controlled (QC'd) data in daily .csv files for the relevant duration specific to each instrument, along with separate .csv file that contains the units for each variable. Some instrument daily files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. Note the degree of QC varied between each instrument due to time constraints. Particular time and attention was given to perform quality control tests on the acoustic based instruments that are particularly suscep...

16 TIDAL AND WAVE POWER↗

In-Situ Blade Strain Measurements of a Crossflow Turbine Operating in a Tidal Flow

This data was collected between October 25 and December 12 of 2022 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). The goal was to collect blade strain data from a crossflow turbine operating in a tidal flow. A table in ('Deployment Schedule.PNG') outlines the various dates when each instrument was operational, and more details can be found via literature listed in 'Related Publications'.txt. This dataset includes zipped folders for each instrument containing data in .csv files for the relevant duration specific to each instrument, along with separate README file for each measurement. Some instrument files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. All data contained in this submission is unfiltered/unprocessed data unless otherwise noted in the README file. Blade strain was measured using 8 foil-based strain gauges along the span of a single turbine blade. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) both upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal flow with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Chancey 2019. The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. A single blade of this turbine was further modified to accommodate 8 full-bridge strain gauges (Bharath et al 2023, Bichanich et al 2024). For power performance and other relevant details on the turbine and its characteristics, see O'Byrne 2022.

16 TIDAL AND WAVE POWER↗

High-speed phase contrast imaging of spray breakup of jet fuels under combusting conditions

X-ray phase contrast imaging is conducted at 90,517 Hz on a fuel spray to characterize the breakup of the bulk fuel into ligaments and individual droplets in a single-sector, swirl-stabilized combustor under reacting conditions. Phase contrast imaging is used to qualitatively assess spray breakup for two fuels: Jet-A, which represents a normal viscosity fuel, and a blend of JP-5 (64%) and farnesane (36% by volume), which represents a high-viscosity fuel, at three fuel-flow rates and two air inlet temperatures. Time-series images of the fuels show that atomization occurs much more rapidly at higher fuel pressure with thinner ligaments being rapidly shredded. The high-viscosity fuel is qualitatively observed to have markedly longer, thicker ligaments and larger droplet diameters after the primary breakup than the normal viscosity fuel. Using an image processing and droplet quantification strategy, the mean droplet velocity magnitudes were found to decrease with decreasing fuel pressure and fuel-flow rate. The increase in preheat temperature from 323 to 370 K results in an increase in the mean droplet velocity magnitude and a decrease in numerical average and Sauter mean diameter, indicating improved atomization. The high-viscosity fuel was found to have larger average droplet diameters at each condition than the normal viscosity fuel. The increased preheat is found to enhance the combustion efficiency, which is hypothesized to couple with the improved atomization due to the higher combustion temperatures. This indicates the importance of examining spray atomization and breakup under realistic combusting conditions for relevant fuels as the heat release directly couples with the atomization process.

42 ENGINEERING↗