Search NASA⌕ Search

SEARCH · Search NASA

Results for “diffraction tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Micrometer to Atomic Scale Characterisation of Primitive Astromaterials Using A Novel Method, Metis-Fa: A Coordinated Atom Probe Tomography, Transmission Electron Microscopy and NanoSIMS Approach

Introduction: Presolar grains preserve isotopic, chemical and microstructural records of physical and chemical processing, and formation mechanisms within a vast range of evolved stellar systems, the interstellar medium, solar nebula and their parent bodies. These evolutionary records are preserved at the micrometric to atomic scale, requiring coordinated studies to expand our understanding of evolutionary processes occurringthroughout ours and external stellar systems [1]. NanoSIMS enabled rapid in situ identification and isotopic characterisation of presolar grains and their stellar origins using 17O/16O and 18O/16O, and 13C/12C isotopic ratios [1]. Coordination with transmission electron microscopy (TEM) revealed crystallographic and localised contextual relationships and quantitively constrained their major and minor compositions [1]. However, trace elements cannot be quantified, the most sensitive geochemical tracers of environmental conditions, essential to unravelling the chemical record of their evolutionary pathway and parent stellar systems [2-3] . Furthermore, owing to the combination of technical limitations (only 5 – 7 isotopes can be measured per NanoSIMS run) and their small grain sizes of 100 nm < 3 μm (with rare exceptions in nanodiamonds (2 nm ≤) and SiC (< 40 μm)), the number of measurable isotopes per grain volume is limited [1,3] . Through more comprehensive isotopic studies of presolar grains, NanoSIMS studies have shown the importance of the latter, identifying Fe and Mg as important indicators of nuclear synthetic processing and their stellar origins, respectively [4- 5]. Coordination of NanoSIMS and Atom Probe Tomography (APT) revealed morphological signatures, and isotopic and chemical signatures at major to trace levels without requirements for preselection of elements [6]. However, crystallographic signatures in localized contextual relationships cannot be measured. Consequently, coordination of NanoSIMS, TEM and APT is essential to gain access to almost all contextual, structural and geochemical signatures within each presolar grain.Transmission electron microscopy requires a 100 nm thin lamella which is unstable in APT and would not produce any viable data. Atom probe tomography requires a needle-shaped specimen which when measured in TEM removes the local context, impacts the quality of the TEM diffraction images due to the shank angle of the needle, and can alter the chemistry of beam sensitive materials from the higher degree of surface exposure at the tip. To address these issues, we developed METIS-Fa (Multi-technical measurements of Electron Transparent materials using an Indium Sandwich - a FIB approach). A novel method which enables coordination of NanoSIMS, TEM and APT for generalized and targeted studies of individual grains, including beam sensitive materials, without compromising sample preparation requirements for TEM and APT. This method requires only indium and a Focus Ion Beam (FIB), minimizing the movement of fragile materials while still enabling preparation of TEM lamella into APT needles. Samples: Initial experimental development and testing of the method occurred at Astromaterials Research and Exploration Science (ARES), Johnson Space Centre (JSC), NASA and APT measurements and needle preparation occurred at JdLC, Curtin University. Synthetic silicate samples were used as analogs for presolar silicates when performing a trial run of the method. Samples were extracted from a polished thin section created at JSC, NASA, comprised of 38 wt.% Si, 17 wt.% FeO, 13 wt.% MgO, 12 wt.% Al, 11 wt.% Ca based on electron microprobe analysis (EMPA) [8] . Experimental details, pressure and temperature conditions were presented in [8] and references therein. Testing of the capability to target individual grains in mineral matrices using this method for acquisition in APT, measured matrix regions in meteoritic thin sections of primitive meteorites. These meteorites and their identified presolar grains for future targeted studies are detailed in [9]. Techniques: The TEM-FIB lamella were prepared using a FIB. An e-beam assisted pt deposition was used as a protective coating for the synthetic and meteoritic samples. When targeting individual grains, a secondary e-beam assisted pt deposition button is placed over the desired grain before the protective coating to denote its location. A JEOL 2500SE field-emission TEM was used for high-resolution imaging, energy-dispersive X-ray (EDX) and electron diffraction data.TheMETIS-Fa method was experimentally designed, tested and executed using a FIB at ARES, JSCNASA. Needles for APT were prepared using the Tescan Lyra3 GM Dual Beam Focus Ion Beam (FIB) Field Emission SEM (FE-SEM) at the JdLC, Curtin University. Atom probe tomography measurements were conducted using a CAMECA Local Electrode Atom Probe, LEAP 4000X HR. Two pure indium needles were analyzed initially to constraining acquisition parameters and stability under the beam. Manual acquisition was required to maintain evaporation of specimen’s at the apex and monitor interactions with measurement parameters. Experimental Design: Indium foil is pressed onto an Al stub with a pneumatic press and mounted into the FIB adjacent to the TEM-FIB lamella of interest. Using a FIB, two indium slices (5 μm x ~300 nm x 3 μm) are extracted from indium foil and aligned with the TEM-FIB lamella before touching the TEM-FIB lamella. Each slice is then attached through cold welding to the FIB-TEM lamella. This approach eliminates the need for chemical treatments and proved effective for aligning the Indium within the region of interest for APT, holding it in place for up to 4 days during testing.Once both indium slices are attached within their pre-determined region per grain targeting requirements, they are gradually melted onto the FIB-TEM lamella.When targeting a specific grain, measurements should be taken of the pt button and its distance from edge to edge of the lamella before and after sandwiching. A secondary button should be placed over the same region after the Indium slices have been attached to improve precision when preparing APT needles. Results: Figure 1 shows two indium slices melted onto a FIB-TEM lamella, adding additional bulk for preparation into APT needles as shown in Figure 2 [7] . The latter was essential so samples could be measured in TEM and APT without compromising sample preparation requirements and consequently data quality and acquisition stability. METIS-Fa proved effective forimproving geometry. Figure 3 shows a successful APTrun of the synthetic silicate. EMPA, TEM and APTshowed no chemical alterations. During targetingtesting, a solar silicate grain was successfully identifiedand measured in TEM, and prepared into an APTneedle. However, the indium was melted too long during sample preparation, causing expansion andformation of internal porosity leading to sample loss.Conclusion: METIS-Fa greatly expands the number of isotopic and chemical signatures measured per grain volume, and enables measurements of contextual, structural, crystallographic, isotopic and geochemical signatures within individual grains. Gaining access to such a vast range of evolutionary signatures required for expanding our understanding of external stellar and planetary systems and the evolution of our solar system. This method was designed for application to a vast range of phases including being sensitive materials and thus provides a way for coordination of NanoSIMS, TEM and APT not just for the study of presolar grains and by extension primitive astromaterials, but studies in a vast range of other fields including the geosciences and material sciences.Acknowledgments: Thankyou to ARES, JSC, NASA; JdLC Curtin University and Space Science Technology Centre for the use of laboratory facilities and funding [confirm].

Nicole D Nevill↗

Corrosion sensitivity of nickel-based Alloy Inconel 600 in pressurized water reactor water chemistry: Can KOH replace LiOH?

Lithium hydroxide (LiOH) has been used to balance water acidity against boric acid moderators in the primary water of Western pressurized water reactor (PWR) designs for decades. However, the demand and the cost of lithium-7 has grown significantly since 2015. Potassium hydroxide (KOH) has been identified as a suitable and cost-effective substitute for LiOH and has been used successfully in Russian PWR designs for more than 40 years. However, it is important to know if alloys and water conditions used in Western PWR’s (Alloy 600) are similarly compatible with KOH additions. This work is focused on the aqueous corrosion behaviors of Alloy 600 with LiOH versus KOH additions at normal operating concentrations and crevice water chemistry at simulated PWR primary water conditions. TEM was used to characterize the formed oxide through diffraction analysis; SIMS was used to probe the cation ingress into the material; Atom probe tomography was used to determine the 3D elemental distribution within the oxide/metal structures; finally electrochemical impedance spectroscopy was used to discuss the structure and corrosion resistance of the oxide films. These advanced characterization techniques complement the weight measurments which showed lower mass gain in KOH than LiOH crevice water due to less oxide formation. Overall, the use of KOH as a potential alternative to LiOH in PWR is discussed.

Alloy 600↗

Micromechanical aspects of deformation and failure of advanced Iron-Chromium-Aluminum alloys

Here this work investigates the micromechanical deformation and failure mechanisms of advanced FeCrAl alloys developed for use in nuclear reactors as cladding material. Three different FeCrAl alloys (82-X)Fe-13Cr-5Al-X (X=Nb, TiC, 0 for base alloy) were investigated both in their as-received and welded states. In-situ neutron diffraction with simultaneous digital image correlation was used to determine micromechanical deformation mechanisms not only as a function of elemental composition but also as a condition of state (as-received vs. welded). Ex-situ X-ray computed tomography was used on as-deformed samples to help determine the failure mechanisms and void initiation strains.

36 MATERIALS SCIENCE↗

Status Report on Development of a Cask to Enable Pulsed Neutron Characterization of Irradiated Fuel

We present the design of a shielding cask that allows pulsed neutron characterization of irradiated fuel rodlets prior to their destructive examination in hot cells. The goal is to provide complementary and informative measurements that will inform subsequent hot cell PIE examinations by identifying typical and atypical regions with respect to microstructure, tomographic data, or isotope densities. Time-of-flight neutron diffraction has the potential to offer efficient, non-destructive and non-contact microstructural characterization of irradiated fuel pins with spatial resolution of 1 mm3 to 1 cm3 while for energy-resolved neutron imaging (and by extension tomography) a resolution of 100 μm was demonstrated. The potential results include crystallinity vs. amorphous volumes and microstructural information such as phase compositions and textures from the diffraction data as well as distances (e.g. pellet to cladding), cracks, and isotopic distributions of minor actinides, fission products as well as fission gas partial pressures e.g. in the plenum from energy resolved neutron imaging. The capability will identify regions of atypical behavior and provide cost effective bulk characterization of entire samples prior to destructive evaluation in hot cells. This effort is a collaboration between LANL, INL, ORNL, and UC Berkeley. A key facet of the initiative is the ability to cost effectively ship irradiated fuels from INL to the pulsed spallation neutron source at LANSCE. The irradiated fuel would be loaded in the custom designed cask (designated RaMHaM) at INL hot cells which then could be shipped in a BRR Type B shipment container between INL and LANL. No hot cell is required after the loading of the sample at INL in the pathway laid out in this report, greatly simplifying handling at LANL.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Enhancing Mechanical Properties of Carbon–Silicon Steel through Two–Stage Quenching and Partitioning with Bainitic Transformation: Ultimate Tensile Strength of 1875 MPa and Total Elongation of 8.03%

To achieve the desired microstructural properties, the ongoing development and innovation in new structural steels require novel thermal processing. This study aims to improve the mechanical properties of a commercial spring carbon–silicon steel by tailoring its microstructure through a process involving quenching and partitioning (Q&P) followed by bainitic transformation. A two–stage Q&P process is proposed to generate a nanoscale dispersion of stable retained austenite and carbides within the tempered martensite and bainite microstructure. The resulting tensile properties demonstrate a yield strength of 1280 MPa, an ultimate tensile strength of 1875 MPa, and a total elongation of 8.03%. These values surpass those of conventional spring 9254 steel, highlighting the effectiveness of the thermal treatment design. Microstructure analysis reveals the presence of tempered martensite, bainite sheaves, nanoscale carbides, and aggregates of retained austenite. Moreover, the resulting body–centered cubic matrix exhibits minimal lattice tetragonality of ≈1.0051, coupled with stable retained austenite featuring a carbon concentration of ≈3.42 ± 0.5 wt%, resulting in outstanding strength–ductility properties. In conclusion, these findings indicate that the proposed two–stage Q&P process, followed by bainitic transformation, significantly enhances the mechanical properties of carbon–silicon steels, making it a promising candidate for high–performance spring applications.

36 MATERIALS SCIENCE↗

Investigation on paper cup waste degradation by bacterial consortium and Eudrillus eugeinea through vermicomposting

Highlights: • This piece of work high lights the addition of microbial consortia to the vermin bin reduces the period of degradation of paper cup waste. • This study proves the degradation of paper cup waste through the instrumental analysis like FT-IR, SEM and XRD. • This experimental work leads to the fine separation of polyethylene terephthalate (PET) from paper cups through the action of microbial consortium. • This work highlights the reuse of waste (paper cup waste) into value added product (Organic manure). - Abstract: Disposable Paper cups are a threat to the environment and are composed of 90% high strength paper with 5% thin coating of polyethylene. This polyethylene prevents the paper cup from undergoing degradation in the soil. Hence, in the present study two different approaches towards the management of paper cup waste through vermicomposting technology has been presented. The experimental setup includes 2 plastic reactors namely Vermicompost (VC) (Cow dung + Paper cup waste + Earthworm (Eudrillus eugeinea)) and Vermicompost with bacterial consortium (VCB) (Cow dung + Paper cup waste + Eudrillus eugeinea + Microbial consortia such as Bacillus anthracis, B. endophyticus, B. funiculus, B. thuringiensis, B. cereus, B. toyonensis, Virigibacillius chiquenigi, Acinetobacter baumanni and Lactobacillus pantheries). After treatment the physicochemical parameters were analysed. The results showed that the values of TOC (26.52 and 37.47%), TOM (36.01 and 33.13%) and C/N (15.02 and 11.92%) ratio are reduced in both VC and VCB whereas, the values of pH (8.01 and 7.56), EC (1.2–1.9 µs{sup −1} and 1.4–1.9 µs{sup −1}), TP (46.1 and 51%), TMg (50.52 and 64.3%), TCa (50 and 64%), TNa (1.39 and 1.75%) and TK (1.75 and 1.86%) have increased. This study substantiates the addition of the microbial consortia augmenting the degradation in VCB reactor by reducing the period of process from 19 to 12 weeks. Further the characterisation of the vermicompost prepared from paper cup with FT-IR shows high degradation of carboxylic and aliphatic group; SEM analysis shows the disaggregation of cellulose and lignin; XRD shows the degradation of cellulose. All these analyses endorse the degradation of the paper cup waste faster with microbes (VCB). Thus, this present study high lights management of the paper cup waste in a relatively short period of time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Shielding maze design for Line C tunnel at LANSCE - 25456

The Los Alamos Neutron Science Center (LANSCE) is a major experimental facility at Los Alamos National Laboratory. The LANSCE linear accelerator (linac) supplies proton beams to five experimental areas simultaneously. The Isotope Production Facility (IPF) utilizes a 100-MeV beam after the first stage of acceleration, all other facilities use proton beams at 800 MeV. However, the facility can support sole-use experiments at 200-600 MeV proton beam energies. There are three spallation neutron sources providing neutrons in different energy regimes: Weapons Neutron Research (WNR), Lujan Neutron Scattering Center (Lujan Center) and the Ultra Cold Neutron source (UCN). The proton radiography (pRAD) facility utilizes the energetic proton beam for imaging and tomography directly. The beam to pRAD and UCN facilities is delivered via line X that splits into line C (pRAD) and line B (UCN). Due to engineering access controls it is impossible to deliver beam to UCN while the pRAD facility is occupied. The goal of our project was to design a shielding maze arrangement for line C to allow for simultaneous beam delivery to UCN while pRAD area (dome) is occupied. (authors)

43 PARTICLE ACCELERATORS↗

Characterization of the crystal structure, kinematics, stresses and rotations in angular granular quartz during compaction

Three-dimensional X-ray diffraction (3DXRD), a method for quantifying the position, orientation and elastic strain of large ensembles of single crystals, has recently emerged as an important tool for studying the mechanical response of granular materials during compaction. Applications have demonstrated the utility of 3DXRD and X-ray computed tomography (XRCT) for assessing strains, particle stresses and orientations, inter-particle contacts and forces, particle fracture mechanics, and porosity evolution in situ . Although past studies employing 3DXRD and XRCT have elucidated the mechanics of spherical particle packings and angular particle packings with a small number of particles, there has been limited effort to date in studying angular particle packings with a large number of particles and in comparing the mechanics of these packings with those composed of a large number of spherical particles. Therefore, the focus of the present paper is on the mechanics of several hundred angular particles during compaction using in situ 3DXRD to study the crystal structure, kinematics, stresses and rotations of angular quartz grains. Comparisons are also made between the compaction response of angular grains and that of spherical grains, and stress-induced twinning within individual grains is discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron Microscopy Approaches to Unraveling the Structure of Amorphous Materials

Determining atomic structures in crystalline materials—where atoms are arranged in rigid, periodic lattices—has been highly successful using probes such as electrons, X-rays, and neutrons. In contrast, amorphous materials, despite their ubiquity and technological importance, remain far more challenging to characterize with comparable accuracy and precision. This review highlights existing, emerging, and potential (scanning) transmission electron microscopy ((S)TEM) techniques for probing short- and medium-range order in amorphous materials. Approaches ranging from high-resolution (S)TEM imaging and selected electron diffraction pattern to four-dimensional STEM (4D-STEM) based pair distribution function, fluctuation electron microscopy, tomography, ptychography, and spectroscopic methods are discussed, emphasizing their ability to provide complementary insights across multiple length scales—from sub-angstrom local environments to nanometer-scale correlations. Here, we further explore the promise of multimodal and correlative strategies, as well as the growing role of machine learning and physics-informed AI in enabling real-time, quantitative interpretation of complex structural signatures. Together, these advances point toward a future where electron microscopy not only reveals the hidden order in amorphous systems but also establishes robust structure–property relationships, paving the way for materials innovation in disordered matter.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Characterization of the effects of different tempers and aging temperatures on the precipitation behavior of Al-Mg (5.25at.%)-Mn alloys

We investigated the effects of different tempers (H131 and H116) and different aging temperatures (50 and 70 °C) on the precipitation behavior of Al-Mg (5.25 at.%)-Mn (Al 5083) alloys aged for a long time (41 and 30 months) using electron backscatter diffraction(EBSD), scanning transmission electron microscopy(STEM), energy-dispersive X-ray spectroscopy(EDS), atom probe tomography (APT), and small angle neutron scattering (SANS). Results for the GP zones and β'' phases were found in Al 5083 H116 aged at 50 °C for 24 months using APT. EDS and SANS revealed that a phase transformation process from GP zones to β'/β phases occurred for precipitates formed in both Al 5083 H131 and H116 aged at 70 °C. The effective diffusion coefficient of Mg in Al 5083 H131 is 1.8 times of that in Al 5083 H116 aged at 70 °C. The precipitation process in Al 5083 H116 aged at 50 °C is much slower than that in the sample aged at 70 °C. Finally, we identified the coarsening process in Al 5083 H131 and H116 aged at 70 °C for > 9 months.

36 MATERIALS SCIENCE↗

High-energy micrometre-scale pixel direct conversion X-ray detector

The objective of this work was to fabricate and characterize a new X-ray imaging detector with micrometre-scale pixel dimensions (7.8 µm) and high detection efficiency for hard X-ray energies above 20 keV. A key technology component consists of a monolithic hybrid detector built by direct deposition of an amorphous selenium film on a custom designed CMOS readout integrated circuit. Characterization was carried out at the synchrotron beamline 1-BM-B at the Advanced Photon Source of Argonne National Laboratory. The direct conversion detector demonstrated micrometre-scale spatial resolution with a 63 keV modulation transfer function of 10% at Nyquist frequency. In addition, spatial resolving power down to 8 µm was determined by imaging a transmission bar target at 21 keV. X-ray signal linearity, responsivity and lag were also characterized in the same energy range. Finally, phase contrast edge enhancement was observed in a phase object placed in the beam path. This amorphous selenium/CMOS detector technology can address gaps in commercially available X-ray detectors which limit their usefulness for existing synchrotron applications at energies greater than 50 keV; for example, phase contrast tomography and high-resolution imaging of nanoscale lattice distortions in bulk crystalline materials using Bragg coherent diffraction imaging. Here, the technology will also facilitate the creation of novel synchrotron imaging applications for X-ray energies at or above 20 keV.

36 MATERIALS SCIENCE↗

Laser Scattering Tomography for the Study of Defects in Protein Crystals

The goal of this research is to explore the application of the non-destructive technique of Laser Scattering Tomography (LST) to study the defects in protein crystals and relate them to the x-ray diffraction performance of the crystals. LST has been used successfully for the study of defects in inorganic crystals and. in the case of lysozyme, for protein crystals.

Feigelson, Robert S.↗

Semi-Automated, Object-Based Tomography of Dislocation Structures

The characterization of the three-dimensional arrangement of dislocations is important for many analyses in materials science. Dislocation tomography in transmission electron microscopy is conventionally accomplished through intensity-based reconstruction algorithms. Although such methods work successfully, a disadvantage is that they require many images to be collected over a large tilt range. Here, we present an alternative, semi-automated object-based approach that reduces the data collection requirements by drawing on the prior knowledge that dislocations are line objects. Our approach consists of three steps: (1) initial extraction of dislocation line objects from the individual frames, (2) alignment and matching of these objects across the frames in the tilt series, and (3) tomographic reconstruction to determine the full three-dimensional configuration of the dislocations. Drawing on innovations in graph theory, we employ a node-line segment representation for the dislocation lines and a novel arc-length mapping scheme to relate the dislocations to each other across the images in the tilt series. We demonstrate the method for a dataset collected from a dislocation network imaged by diffraction-contrast scanning transmission electron microscopy. Based on these results and a detailed uncertainty analysis for the algorithm, we discuss opportunities for optimizing data collection and further automating the method.

47 OTHER INSTRUMENTATION↗

Synchrotron-based diffraction-enhanced imaging and diffraction-enhanced imaging combined with CT X-ray imaging systems to image seeds at 30 keV

Utilized the upgraded Synchrotron-based non-destructive Diffraction-enhanced imaging and Diffraction-enhanced imaging coupled with CT X-ray imaging systems to image the chickpea seeds, to enhance the contrast in plant root architecture, visibility of fine structures of root architecture growth and some aspects of physiology at acceptable level. DEI-CT images were acquired with 30 keV synchrotron X-rays. A series of DEI-CT slices were assembled together, to form a 3D data set. DEI-CT images explored more structural information and morphology. Noticed detailed anatomical, physiological observations, and contrast mechanisms. Furthermore, with these systems, some of the complex plant traits, root morphology, growth of laterals and subsequent laterals can be visualized directly.

36 MATERIALS SCIENCE↗

Boron Removal by Adsorption on Cobalt(II) Doped Chitosan Bio-composite

Cobalt(II) doped chitosan bio-composite was prepared, characterized and used to oxoborate separation from aqueous solutions. The adsorption process was carried out in a batch system. The effect of pH, temperature, time and initial boron concentration on the boron adsorption were tested. The maximum boron adsorption was reached at pH range 8.0–8.5 at room temperature and within 60 min. Calculations based on Langmuir and Freundlich models showed the heterogeneous nature of boron adsorption on Co-CTS bio-composite. On the base of research on optimization of pH and results from XRD and FTIR analysis it was found that boron adsorption by Co-CTS occurred through the co-precipitation and adsorption of B on cobalt hydroxide following the Coulomb attraction of B(OH){sub 4}{sup −} species on positively charged sites and molecular attraction of H{sub 3}BO{sub 3} through hydrogen bond with amine or hydroxyl groups of chitosan. The modelling of the thermodynamic data indicated the nonspontaneous and exothermic nature of the adsorption process. The pseudo-second-order model adequately described the boron adsorption on Co-CTS hydrogel. Desorption by means of alkaline solution at pH 12 was carried out successfully. Adsorption–desorption efficiencies in 3 cycles were almost 100%.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-performance and stable AgSbTe 2 -based thermoelectric materials for near room temperature applications

AgSbTe 2 -based ternary chalcogenides show excellent thermoelectric performance at low- and middle-temperature ranges, yet their practical applications are greatly limited by their intrinsic poor thermodynamic stability. In this work, we demonstrate that AgSbTe 2 -based ternary chalcogenides can be stabilized for service below their decomposition threshold. A series of Ag x Sb 2-x Te 3-x (x = 1.0, 0.9, 0.8 and 0.7) samples have been prepared by the melt-quenching method. Among them, phase pure Ag 0.9 Sb 1.1 Te 2.1 is verified by comprehensive structural characterizations from macroscale by X-ray diffraction to microscale by energy-dispersive spectroscopy and then to sub-nanometer scale by atom probe tomography. This composition is further chosen for the stability investigation. The decomposition threshold of Ag 0.9 Sb 1.1 Te 2.1 appears around 473K. Below this temperature, the chemical compositions and thermoelectric properties are barely changed even after 720 h annealing at 473 K. The figure-of-merit (zT) value of Ag 0.9 Sb 1.1 Te 2.1 below the decomposition threshold is very competitive for real applications even compared with Bi 2 Te 3 -based alloys. The average zT of Ag 0.9 Sb 1.1 Te 2.1 at 300–473 K reaches 0.84, which is higher than most other thermoelectric materials in a similar temperature range, promising applications in miniaturized refrigeration and power generation near room temperature.

36 MATERIALS SCIENCE↗

Effect of laser power on defect, texture, and microstructure of a laser powder bed fusion processed 316L stainless steel

The effect of laser power on defect characteristics, microstructure development, constituent phases, and crystallographic texture was studied on a laser powder bed fusion (L-PBF) processed 316L stainless steel. A series of cylindrical specimens were additively manufactured as a function of laser power ranging from 380 to 200W with a fixed scan speed of 300 mm/s using a selective laser melting system. The density (in terms of count, surface area, and porosity), size (mean values of major axis length, surface area, and volume), shape (aspect ratio and sphericity), and orientation (in terms of the angle between the major axis and build direction) of macroscopic defects in as-printed L-PBF cylinders were characterized using high-resolution synchrotron x-ray computed microtomography with a 0.65μm resolution. Moreover, the changes in the preferred crystallographic orientations and constituent phases were investigated using high-energy synchrotron x-ray diffraction. Finally, the melt pool shape and grain size/orientation were analyzed using metallography. The results show that the porosity increases linearly from 0.13 to 0.88% with the decrease in laser power. However, even with the decrease in laser power by about half and corresponding seven-fold increase in porosity, the 200W case can still be considered as nearly fully dense. On the other hand, with the same decrease in the laser power, the melt pool size/shape, grain size, and texture changed significantly. In conclusion, the role of energy input in the simultaneous changes in defect properties and microstructure development will be discussed.

36 MATERIALS SCIENCE↗

Versatile and compact wide-range VUV spectrometer for quantitative measurements

Main parameters of a new scheme of a compact VUV grazing incidence spectrometer based on a plane amplitude diffraction grating are considered. The spectrometer will allow simultaneous detection of spectra at the +1st order diffraction edge with a sufficiently high ( λ/δ λ ∼ 150) spectral resolution and in the –1st order with a moderate resolution ( λ/δ λ ∼ 15 – 30), but in a very wide (5 – 200 nm) spectral range. The use of such a spectrometer is promising for measuring the absolute radiation yield in these spectral regions, which is necessary for the diagnostics and control of plasma radiation sources, including those intended for projection EUV nanolithography. (vuv spectroscopy)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗