Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct counts”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Upper limits for X-ray and energetic neutral particle emission from Jupiter - Voyager-1 results

The X-ray sensitivity of the low energy proton channels in the Low Energy Charged Particle (LECP) experiment and its directional measurements determined whether X-rays from Jupiter can be recognized as additional flux above background as Voyager 1 approached the planet. Between about 230 and about 100 R(J), a statistically significant count rate was detected interpreted as X-rays and/or neutral particles. Such an X-ray flux leads to estimates of precipitating electrons over the Jovian polar caps which are 200 times larger than over observed electron fluxes in the Io plasma torus.

Kirsch, E.↗

Sensitivity analysis and approximation methods for general eigenvalue problems

Optimization of dynamic systems involving complex non-hermitian matrices is often computationally expensive. Major contributors to the computational expense are the sensitivity analysis and reanalysis of a modified design. The present work seeks to alleviate this computational burden by identifying efficient sensitivity analysis and approximate reanalysis methods. For the algebraic eigenvalue problem involving non-hermitian matrices, algorithms for sensitivity analysis and approximate reanalysis are classified, compared and evaluated for efficiency and accuracy. Proper eigenvector normalization is discussed. An improved method for calculating derivatives of eigenvectors is proposed based on a more rational normalization condition and taking advantage of matrix sparsity. Important numerical aspects of this method are also discussed. To alleviate the problem of reanalysis, various approximation methods for eigenvalues are proposed and evaluated. Linear and quadratic approximations are based directly on the Taylor series. Several approximation methods are developed based on the generalized Rayleigh quotient for the eigenvalue problem. Approximation methods based on trace theorem give high accuracy without needing any derivatives. Operation counts for the computation of the approximations are given. General recommendations are made for the selection of appropriate approximation technique as a function of the matrix size, number of design variables, number of eigenvalues of interest and the number of design points at which approximation is sought.

Murthy, D. V.↗

Spectra of comet P/Halley at R = 4 - 8 AU

Spectra of Comet Halley (lambda lambda = 3400-6500 A) were acquired at pre- and post-perihelion distances of 4.8 AU on 1985 Feb. 17 (Coma V equals 18.9 mag) and 1987 Feb. 1 (coma V = 15.9 mag) using the 4.5-m Multiple-Mirror Telescope (MMT) and the CTIO 4.0-m telescope, respectively. The CN(0,0) violet system band flux at 4.8 AU was approx. 15 times greater at the post-perhelion phase compared to pre-perihelion. Additional post-perihelion spectra, obtained on 1986 Nov. 28 to 30 with the MTT, showed CN(0,0) and very weak C3 4040 A emission. The MMT data are one-dimensional spectra (aperture: 5 arc sec diameter) obtained with an intensified Reticon while the CTIO data are two-dimensional spectra (slit length = 280 arc sec) obtained with a 2D-Frutti photon counting system. Extended CN(0,0) emission was detected in the 1987 Feb. 1 (at 4.8 AU) spectra to a distance of at least 70 arc sec in the solar and anti-solar directions. Additional CCD spectra obtained with the KPNO 2.2-meter telescope on 1988 Feb. 20 (at 7.9 AU) show scattered solar continuum approx. 32 arc sec diameter. However, no emission features were detected at 7.9 AU.

Wehinger, Peter A.↗

Some characteristics of the solar flare event of February 16, 1984

In the morning of February 16, 1984 a solar cosmic ray event (GLE) was recorded by the world wide network of neutron monitors (NM). The counting rate vs. time profile of the Goose Bay NM (geog. lat. = 53.3 deg. N, deog. long. = 299.6 deg E) where the increase is expressed as percent of the counting rate of an equatorial sea level NM is presented. The Goose Bay NM was observed to have the maximum response to the solar particles. Its counting rate vs. time profile exhibits a rapid increase to maximum, has a large amplitude (approx. 170%) and decays rapidly to background in approx. 90 min. In Fig. 1 we also show the counting rate vs. time profile for the Tixie Bay NM (71.6 deg, 128.9 deg) which recorded an increase of only a few percent. Since the NMs at Goose Bay and Tixie Bay have asymptotic viewing directions approx. 180 deg apart in longitude, the anisotropy of the solar particle flux at Earth from these stations.

Debrunner, H.↗

Working at the Ohio Aerospace Institute

The Ohio Aerospace Institute is a wonderful place to work. I enjoy coming to work everyday knowing that I will be surrounded by smiling faces. My mentor, Mary Auzenne, is the Program Manager of the LERCIP College Internship Program, however, I spend most of my time working with Akua Soadwa, the Assistant Program Manager. She is in charge of planning, coordinating, and managing every event that is involved with the college internship program such as the socials, picnic, banquet, workshops, and research symposium. My job is to make her job easier. I help out with the planning, coordinating, and managing of these events. When I first got on board Akua was in the process of planning the second social for the interns. The social is a way for the interns to interact with one another as well as to find out more about where the other interns are working at NASA. We ordered the food, went shopping, and set up the Guerin House for the party. I made sign-in sheets, which helped us get a rough count of the attendees. The next event was the Technical Presentation Workshop and the Professional Development Workshop. These workshops are designed to enhance skills of the interns. We were there to sign people in and direct them to the room where the presentation was to take place. I also took pictures of the workshop and provided copies for the presenters, as well as our files.

Szabo, Hortenzia↗

Lunar-surface UV Photometric Investigation of Exospheres (LUPINE): Thermal Modeling of Payload in a Relevant Daylit Environment

Direct upward remote sensing of the moon’s exosphere from a surface vantage can address production of water-related lunar volatiles as well as their exospheric loss, ballistic transport, and ultimate adsorption in permanently shadowed regions (PSRs). Far UV (FUV) dayside measurements of atomic oxygen, liberated from regolith by energetic solar protons and micrometeorite impact, can provide critical insight into the endogenic lunar water cycle by constraining total column density [O] at site of production. A notional Lunar-surface UV Photometric Investigation of Exospheres (LUPINE) instrument is designed to exploit solar-pumped atomic oxygen fluorescence at 130.4-nm, in a manner similar to the Apollo 17 UV Spectrometer (UVS) experiment [Fastie 1973; Feldman and Morrison, 1991] and the LRO Lyman-alpha Mapping Project (LAMP) spectrograph [Cook et al., 2013], by implementing a zenith-directed FUV photometer from the lunar surface at low (± 10°) selenographic latitude during the lunar day. Atomic oxygen production from solar energetic particle impact sources is thought to maximize in near solar noon [Sarantos et al., 2012], and the lander-embedded zenith-directed LUPINE photometer, in contrast to UVS and LAMP twilight measurements from orbit, can potentially capture the full column abundance of lunar regolith liberated oxygen. Herein we describe adaptation of FUV reflective optics, pulse-counting electronics, and scattered-light-suppression technologies developed for LEO FUV photometry for the challenging thermal environment of the daylit lunar surface. Preliminary thermal modeling and TVAC measurements of heritage FUV photometer components suggests that, if allowed to shed ~8W of waste heat into the bus of a reference Commercial Lunar Payload Services (CLPS) lander, the LUPINE photometer will be kept sufficiently cool to limit dark current to less than 20 counts/s. This level of dark signal enables an OI 130.4-nm 3-sigma detection threshold of ~1 mR for assumed 2-hour integrations.

Lunar UV Photometer↗

An Overview of Experiments and Modeling of Polysiloxane-Coated Thermal Protection Systems for Missions to Mars, Titan, and Beyond.

Phenolic Impregnated Carbon Ablator (PICA) gained heritage during the historic Stardust mission, where it successfully returned samples from a comet’s tail and has since been instrumental in delivering payloads to the surface of Mars [1-3]. Most recently, PICA enabled the safe return of samples collected from asteroid Bennu as part of the OSIRIS-REx mission. This rich legacy underscores PICA’s critical role in allowing NASA’s most ambitious exploration missions. However, the friable nature of its phenolic phase presents challenges during handling and pre-launch activities. To mitigate this issue, PICA is coated with a polysiloxane resin system, which serves to suppress particulate dispersion and thereby safeguard spacecraft components. A comprehensive understanding of the polysiloxane resin’s behavior is imperative, as it profoundly shapes the material response of PICA during atmospheric entry by influencing its thermal and oxidative stability. This influence extends to thermocouple plugs embedded within thermal protection systems. These plugs have demonstrated their significance in missions such as Mars Science Laboratory (MSL) and Mars 2020, where the MEDLI and MEDLI2 instrumentation suites delivered in-valuable insights into the performance of thermal protection systems during entry into the Martian atmosphere [4]. Looking ahead, missions such as Dragonfly, set to descend into Titan’s dense atmosphere, aim to leverage advanced sensor technologies to further refine our understanding of thermal protection response [5]. Moreover, thermocouple plugs play an essential role in validating cutting-edge material response models, such as those pioneered under NASA’s Entry Systems Modeling Project (ESM), designed, in-part, to predict the operational integrity of thermal protection systems under the extreme stresses of atmospheric entry. To achieve these modeling goals, ground-based experiments are crucial to provide the foundational data necessary for developing and refining these predictive tools. To this end, an extensive test campaign was conducted at the Hypersonic Materials Environmental Test System (HyMETS) to investigate the high-temperature behavior of the polysiloxane resin in an air environment [6]. These experiments revealed critical phenomena, including the formation of a silicon oxycarbide layer that enhances oxidation resistance, moderates surface temperatures, and alters in-depth thermal response. Building on these findings, subsequent tests were designed to simulate atmospheric entry conditions in reactive gases, such as CO2 and N2, to mimic the environments of Mars and Titan, respectively, as well as non-reactive gases representing the atmospheres of the Ice Giants (Neptune and Uranus). A heating rate dependent decomposition mechanism has been identified for the polysiloxane resin under oxidizing conditions (Fig. 1). In the initial stage, the resin and the underlying thermal protection system undergo pyrolysis, rapidly generating a thin amorphous silicon oxycarbide interwoven with carbonaceous char and residual fibers from PICA. During the second stage, the nascent oxide layer establishes a robust, oxidation-resistant thermal barrier coating, which significantly impedes heat transfer to the underlying carbonaceous char, resulting in a stagnation of the surface temperature. A key factor contributing to this thermal resistance is the low recombination efficiency of atomic oxygen (γ), which further diminishes the heat load on the material’s interior layers [7]. Moreover, as the surface temperature stagnates, the silicon oxycarbide phase separates into distinct regions of silica and free graphite. Ultimately, when the heat flux reaches a critical threshold, a third stage is triggered, leading to the breakdown of the coating through carbothermal reduction, exposing the underlying char layer. This exposure leads to a dramatic surface temperature spike, driven by highly exothermic reactions between atomic oxygen and the char layer, further accelerating material degradation. A detailed mass and heat transfer model of PICA coated with polysiloxane resin was implemented in the Porous material Analysis Toolbox based on OpenFOAM, PATO [8]. The initial stage was considered negligible in this model because the resin decomposition occurs rapidly within a thin surface layer. Instead, the coating was directly considered as an oxygen-resistant thermal barrier coating. For the second stage, the thin amorphous silicon oxycarbide was treated as a pure silica surface to simplify the thermochemical behavior. The model ac-counts for surface equilibrium processes using representative elements of the coating-environment system. For the third stage, specific boundary conditions were developed to estimate the onset and progression of the coating removal. Two-dimensional material response simulations were conducted to compare uncoated and coated PICA using boundary conditions calibrated with HyMETS data. Fig. 2 illustrates that the simulations closely align with experimental data, successfully reproducing measured temperature profiles. This work will include the latest advancements in the coating model, including the calibration of recombination of atomic oxygen at the surface during the second phase. These simulated results will be further validated against additional CO2 data points from HyMETS, reinforcing the models’ predictive capabilities. These mechanisms and their effects on thermal protection systems, including thermochemical behavior and thermocouple probe performance in extreme environments, provide crucial insights for optimizing spacecraft designs that safeguard scientific payload and ensure mission success in future planetary exploration endeavors.

Active Oxidation↗

SOHO Ultraviolet Coronagraph Spectrometer (UVCS) Mission Operations and Data Analysis

The scientific goal of UVCS is to obtain detailed empirical descriptions of the extended solar corona as it evolves over the solar cycle and to use these descriptions to identify and understand the physical processes responsible for coronal heating, solar wind acceleration, coronal mass ejections (CMEs), and the phenomena that establish the plasma properties of the solar wind as measured by "in situ" solar wind instruments. This report covers the period from 15 February 2003 to 14 April 2004. During that time, UVCS observations have consisted of three types: 1) standard synoptic observations comprising, primarily, the H I Lyalpha line profile and the 0 VI 103.2 and 103.7 nm intensity over a range of heights from 1.5 to about 3.0 solar radii and covering 360 degrees about the Sun, 2) sit and stare observations for major flare watches, and 3) special observations designed by the UVCS Lead Observer of the Week for a specific scientific purpose. The special observations are often coordinated with those of other space-based and ground-based instruments and they often are part of SOHO joint observation programs and campaigns. Lead observers have included UVCS Co-Investigators, scientists from the solar physics community and several graduate and undergraduate level students. UVCS has continued to achieve its purpose of using powerful spectroscopic diagnostic techniques to obtain a much more detailed description of coronal structures and dynamic phenomena than existed before the SOHO mission. The new descriptions of coronal mass ejections (CMEs) and coronal structures from UVCS have inspired a large number of theoretical studies aimed at identifying the physical processes responsible for CMEs and solar wind acceleration in coronal holes and streamers. UVCS has proven to be a very stable instrument. Stellar observations have demonstrated its radiometric stability. UVCS has not required any flight software modifications and all mechanisms are operational. The UVCS 0 VI Channel with its redundant optical path for wavelengths near H I Lyalpha is capable of observing the entire UVCS wavelength range. The regions of the detector currently being used require different grating angles for direct OVI observations and redundant path H I Lyalpha observations, and so those can no longer be observed simultaneously. Since December 1998, the 0 VI Channel has been used for all UVCS observations. Although the H I Lyalpha Channel and detector are still operational, increases in the dark count up to about 5x10(exp 4) counts/sec/pixel and an increase in high voltage current to within a factor of two of the maximum used in the laboratory before flight led to the decision to not use that detector after 1998. The visible light channel functioned nominally during the reporting period. UVCS data, data analysis software, calibration files and the mission log are available from the SOHO archive and SAO. All UVCS data are now available within three months of the observations to scientists and the general public via the SOHO Data Archive and SAO. UVCS has resulted in 33 scientific papers in 2003. There were numerous presentations at scientific meetings. UVCS Education and Public Outreach activities involved nine members of the UVCS team. During the reporting period, there were over a dozen events directed at students and teachers, museum audiences, and public audiences via the mass media, internet and educational literature.

Gurman, Joseph↗

A TEOM (tm) particulate monitor for comet dust, near Earth space, and planetary atmospheres

Scientific missions to comets, near earth space, and planetary atmospheres require particulate and mass accumulation instrumentation for both scientific and navigation purposes. The Rupprecht & Patashnick tapered element oscillating microbalance can accurately measure both mass flux and mass distribution of particulates over a wide range of particle sizes and loadings. Individual particles of milligram size down to a few picograms can be resolved and counted, and the accumulation of smaller particles or molecular deposition can be accurately measured using the sensors perfected and toughened under this contract. No other sensor has the dynamic range or sensitivity attained by these picogram direct mass measurement sensors. The purpose of this contract was to develop and implement reliable and repeatable manufacturing methods; build and test prototype sensors; and outline a quality control program. A dust 'thrower' was to be designed and built, and used to verify performance. Characterization and improvement of the optical motion detection system and drive feedback circuitry was to be undertaken, with emphasis on reliability, low noise, and low power consumption. All the goals of the contract were met or exceeded. An automated glass puller was built and used to make repeatable tapered elements. Materials and assembly methods were standardized, and controllers and calibrated fixtures were developed and used in all phases of preparing, coating and assembling the sensors. Quality control and reliability resulted from the use of calibrated manufacturing equipment with measurable working parameters. Thermal and vibration testing of completed prototypes showed low temperature sensitivity and high vibration tolerance. An electrostatic dust thrower was used in vacuum to throw particles from 2 x 10(exp 6) g to 7 x 10(exp -12) g in size. Using long averaging times, particles as small as 0.7 to 4 x 10(exp 11) g were weighted to resolutions in the 5 to 9 x 10(exp -13) g range. The drive circuit and optics systems were developed beyond what was anticipated in the contract, and are now virtually flight prototypes. There is already commercial interest in the developed capability of measuring picogram mass losses and gains. One area is contamination and outgassing research, both measuring picogram losses from samples and collecting products of outgassing.

Source record↗

Methodology for Validation of Unsteady Pressure-Sensitive Paint Measurements using Pressure Transducers

Unsteady Pressure-Sensitive Paint (uPSP) technology provides simultaneously high-frequency and high-spatial resolution surface pressure fluctuation measurements. It has demonstrated value in wind tunnel test facilities to evaluate aerospace vehicle unsteady aerodynamics. The calibration of measurements from digital pixel counts into corresponding physical units relies on both lab-based and in-situ calibration steps, and its validation is both challenging and critical to adoption of the technology. We present a rigorous methodology for direct comparison of uPSP-derived surface pressure measurements to reference pressure transducer data based on a model of the camera-based measurement error, a model of the flow field pressure signal, and their propagation through the uPSP data reduction algorithm. The methodology is demonstrated on data collected in a small-scale, subsonic wind tunnel test as well as data collected from a Space Launch System unsteady aerodynamics characterization test at the NASA Ames Research Center Unitary Plan Wind Tunnel Complex.

Pressure-Sensitive Paint↗

Validating uPSP with Transducers

Unsteady Pressure-Sensitive Paint (uPSP) technology provides simultaneously high-frequency and high-spatial resolution surface pressure fluctuation measurements. It has demonstrated value in wind tunnel test facilities to evaluate aerospace vehicle unsteady aerodynamics. The calibration of measurements from digital pixel counts into corresponding physical units relies on both lab-based and in-situ calibration steps, and its validation is both challenging and critical to adoption of the technology. We present a rigorous methodology for direct comparison of uPSP-derived surface pressure measurements to reference pressure transducer data based on a model of the camera-based measurement error, a model of the flow field pressure signal, and their propagation through the uPSP data reduction algorithm. The methodology is demonstrated on data collected in a small-scale, subsonic wind tunnel test as well as data collected from a Space Launch System unsteady aerodynamics characterization test at the NASA Ames Research Center Unitary Plan Wind Tunnel Complex.

Pressure-Sensitive Paint↗

Parallel tridiagonal equation solvers

Three parallel algorithms were compared for the direct solution of tridiagonal linear systems of equations. The algorithms are suitable for computers such as ILLIAC 4 and CDC STAR. For array computers similar to ILLIAC 4, cyclic odd-even reduction has the least operation count for highly structured sets of equations, and recursive doubling has the least count for relatively unstructured sets of equations. Since the difference in operation counts for these two algorithms is not substantial, their relative running times may be more related to overhead operations, which are not measured in this paper. The third algorithm, based on Buneman's Poisson solver, has more arithmetic operations than the others, and appears to be the least favorable. For pipeline computers similar to CDC STAR, cyclic odd-even reduction appears to be the most preferable algorithm for all cases.

Stone, H. S.↗

Fine energy resolution survey of the sky with a germanium gamma-ray spectrometer

A fine-energy-resolution survey (38 to 2700 keV) of the sky has been performed from a spinning polar-orbiting satellite with a cooled germanium spectrometer. The measurements, performed with a fast time resolution (32 ms), permit one to analyze the energy spectra from repeated noon-midnight orbits in selected portions of the local daytime or nighttime sky. During the initial period of the experiment, the sky was surveyed in two broad intervals spanning the galactic plane at longitudes of approximately 255 to 328 deg and 99 to 168 deg, respectively. In the former interval a significant increase in counting rate was observed when the spectrometer viewed the galactic plane. Locally generated backgrounds were removed from the galactic-plane spectrum by subtracting, on a spin-for-spin basis, the contribution measured at a viewing direction with a comparable declination north of the celestial equator. The net spectra from the galactic plane have been examined for evidence of gamma-ray lines. The possible presence of lines near 1121 and 1369 keV emitted from the galactic plane over the galactic longitudinal interval approximately 255 deg to approximately 328 deg is suggested by the data, but better statistics are needed to establish their existence firmly. Comparisons are made with previously reported extraterrestrial lines with assumed normalizations made for the different viewing directions in the two experiments.

Imhof, W. L.↗

Medical support and technology for long-duration space missions

The current philosophy and development directions being taken towards realization of medical systems for use on board space stations are discussed. Data was gained on the performance of physical examinations, venipuncture and blood flow, blood smear and staining, white blood cell differential count, throat culture swab and colony count, and microscopy techniques during a 28-day period of the Skylab mission. It is expected that the advent of Shuttle flights will rapidly increase the number of persons in space, create a demand for in-space rather than on-earth medical procedures, and necessitate treatments for disorders without the provision for an early return to earth. Attention is being given to pressurized environment and extravehicular conditions of treatment, the possibilities of the use of the OTV for moving injured or ill crewmembers to other space stations, and to isolation of persons with communicable diseases from station crews.

Furukawa, S.↗

Photon-counting image sensors for the ultraviolet

An investigation on specific performance details of photon counting, ultraviolet image sensors having 2-dimensional formats is reviewed. In one study, controlled experiments were performed which compare the quantum efficiencies, in pulse counting mode, of CsI photocathodes deposited on: (1) the front surface of a microchannel plate (MCP), (2) a solid surface in front of an MCP, and (3) an intensified CCD image sensor (ICCD) where a CCD is directly bombarded by accelerated photoelectrons. Tests indicated that the detection efficiency of the CsI-coated MCP at 1026 A is lower by a factor of 2.5 than that of the MCP with a separate, opaque CsI photocathode, and the detection efficiency ratio increases substantially at longer wavelengths (ratio is 5 at 1216 A and 20 at 1608 A).

Jenkins, E. B.↗

The role of igneous sills in shaping the Martian uplands

Relations among geologic units and landforms suggest that igneous sills lie beneath much of the intercrater and intracrater terrain of the Martian uplands. The igneous rocks crop out along the upland-lowland front and in crater floors and other depressions that are low enough to intersect the sill's intrusion horizons. It is suggested that heat from the cooling sills melted some of the ice contained in overlying fragmental deposits, creating valley networks by subsurface flow of the meltwater. Terrains with undulatory, smooth surfaces and softened traces of valleys were created by more direct contact with the sills. Widespread subsidence following emplacement of the sills deformed both them and the nonvolcanic deposits that overlie them, accounting for the many structures that continue from ridged plains into the hilly uplands. Crater counts show that the deposit that became valleyed, softened, and ridged probably began to form (and to acquire interstitial ice) during or shortly after the Middle Noachian Epoch, and continued to form as late as the Early Hesperian Epoch. The upper layers of this deposit, many of the visible valleys, and the ridged plains and postulated sills all have similar Early Hesperian ages. Continued formation of valleys is indicated by their incision of fresh-appearing crater ejecta. The dependence of valley formation on internal processes implies that Mars did not necessarily have a dense early atmosphere or warm climate.

Wilhelms, D. E.↗

Microcoupon Assay Of Adhesion And Growth Of Bacterial Films

Microbiological assay technique facilitates determination of some characteristics of sessile bacteria like those that attach to and coat interior walls of water-purification systems. Biofilms cause sickness and interfere with purification process. Technique enables direct measurement of rate of attachment of bacterial cells, their metabolism, and effects of chemicals on them. Used to quantify effects of both bactericides and growth-stimulating agents and in place of older standard plate-count and tube-dilution techniques.

Pierson, Duane L.↗

Cratering on Gaspra

The October 1991 Galileo flyby of Gaspra shows that its crater population is dominated by fresh craters several hundred meters in diameter and smaller. They appear to represent a production population because the spatial density is relatively low (few overlaps) and because fresh craters are very abundant; equilibrium could be attained at diameters near to or below the resolution limit of the best image. These craters are the first direct record of the population of main-belt asteroids some tens of meters in diameter. Craters primarily from the highest resolution, 'high phase' image, on which over 600 craters are visible in 90 sq. km were counted, measured, and classified; earlier counts were made on the lower resolution four-color images, which show an order of magnitude fewer craters because of the resolution limit. The population index (exponent of the differential power law approximately describing the crater sizes) has a very high negative value (-4.3 +/- 0.3, meaning that the log-log slope is 'steep'), appreciably steeper than the value of -3.5 thought to reflect collisional equilibrium according to theory.

Chapman, Clark R.↗