Search NASA⌕ Search

SEARCH · Search NASA

Results for “directional cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Salt-Induced Polymorphs Observed in Colloidal Single Crystals

Polymorphs are solid materials with the same chemical composition but different crystallographic structures. A unique aspect of polymorphs is that they exhibit different physical properties, such as solubility, melting point, density, color, hardness, and bioavailability. Here, we synthesized polymorphs of colloidal crystals engineered with DNA by slow-cooling gold nanoparticle-core programmable atom equivalents (PAEs, particles with DNA sequences that control their bonding characteristics) under salt concentrations ranging from 0.5 to 4 M NaCl. This approach yielded a diverse set of single-crystalline phases with cubic, tetragonal, and hexagonal lattice symmetries. The structural transitions observed here arise solely from the modulation of interparticle repulsion via ionic strength and thermal processing. Notably, in certain cases, we observed diffusionless phase transformations, wherein the superlattices evolve from cubic to lower-symmetry tetragonal lattices. By tuning the thermal stability and salt concentration, we captured intermediate, metastable body-centered tetragonal structures during the slow-cool process, indicating that subtle changes in free energy can direct crystallization to low-symmetry phases. In conclusion, this study demonstrates that thermal and ionic parameters can be tuned to access and stabilize colloidal crystal polymorphs with emergent structures and interesting functional properties.

Colloidal crystallization↗

Topological magnon bands in a room-temperature kagome magnet

Topological magnon is a vibrant research field gaining more and more attention in the past few years. Among many theoretical proposals and limited experimental studies, ferromagnetic kagome lattice emerges as one of the most elucidating systems. Here we report neutron scattering studies of YMn 6 Sn 6 , a metallic system consisting of ferromagnetic kagome planes. This system undergoes a commensurate-to-incommensurate antiferromagnetic phase transition upon cooling with the incommensurability along the out-of-plane direction. We observe magnon band gap opening at the symmetry-protected K points and ascribe this feature to the antisymmetric Dzyaloshinskii-Moriya (DM) interactions. Our observation supports the existence of topological Dirac magnons in both the commensurate collinear and incommensurate coplanar magnetic orders, which is further corroborated by symmetry analysis. This finding places YMn 6 Sn 6 as a promising candidate for room-temperature magnon spintronics applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of fiber reinforcement on the process parameters of injection molding manufacturing process

Use of fillers with the resin is common in injection molding manufacturing technique to enhance the stiffness and strength of the manufactured components. However, the addition of fillers changes the rheological and mechanical properties of the material, required adjustments in the process parameters used for the manufacturing. The present study aims to investigate this impact of fillers on the process parameters of the injection molding manufacturing process. Neat Acrylonitrile Butadiene Styrene (ABS) and ABS reinforced with short glass fibers are used as the materials to perform the comprehensive numerical analysis including complete process sequence, namely filling, packing, cooling and warpage. Parametric studies are conducted to optimize the manufacturing process for minimal warpage (or shrinkage) in the produced part. The selected process parameters for the parametric study include cooling time, packing pressure, and mold temperature, all of which directly impact the quality of the manufactured parts. The optimal values obtained for these parameters are compared to examine the effect fiber reinforcement has on the manufacturing process.

Garg, Nikhil↗

ComStock Measure Documentation: Heat Pump Rooftop Units with Standard Performance

This documentation focuses on a single end-use savings shape measure - heat pump rooftop units (HP-RTUs) with standard efficiencies that are prevalent in the current market. Today, these products are claimed as standard efficiency by the manufacturers and are most commonly installed. This document will primarily discuss the additional changes of performance and configuration of the standard efficiency HP-RTUs while a comprehensive overview of the fundamental modeling methodology and background of the HP-RTU measure, including applicability, sizing scheme, and other key assumptions can be found in the original documentation: Heat Pump RTU. The definition of "standard efficiency" can be a bit vague when considering detailed specifics other than efficiency metrics of a heat pump. Thus, we have focused on reflecting products where manufacturers claim as standard efficiency and products that are not top-of-the-line in their model lineup. Based on gathering information from eight products from four major manufacturers, there are some common (or relatively prevalent) characteristics and we have defined standard efficiency product as follows: direct drive outdoor unit fan, two stages of heat pump cooling, single stage heat pump heating (i.e., all compressors running at the same time), heat pump minimum lockout temperature of 0°F (-17.8°C), backup electric resistance heating, backup heating runs at the same time as heat pump heating , heat pump heating locking out below minimum operating temperature, IEER in between 11-13, and HSPF in between 8-8.9. There are cases where some of these products have other variations: a variable frequency drive fan, dual fuel (i.e., gas backup heating) option, three or more cooling stages, two stages of heat pump heating, no backup heating as default , etc. However, this work tried to reflect the most common and prevalent options for a standard efficiency product.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Online monitoring the hydrolysis of uranium hexafluoride for intermediates by cryogenic layering and FTIR

Uranium hexafluoride (UF 6 ) is a commonly utilized material feedstock in uranium enrichment processes due to its high vapor pressure and ease of sublimation. When exposed to air, UF 6 undergoes spontaneous hydrolysis to form uranyl fluoride (UO 2 F 2 ) particulates which are utilized for the detection of undeclared nuclear activities by nuclear safeguards organizations. In this study, the kinetics of the hydrolysis reaction and how they relate to particle morphology of the product are still debated in the literature. Here, we report the direct, in situ observation of UF 6 reaction intermediates by cooling the reaction to cryogenic temperatures to significantly reduce the rate of hydrolysis. The reaction is then observable by Fourier transform infrared (FTIR) spectroscopy. The conversion of UF 6 to UOF 4 is observed as well as several other bands associated with possible long lived intermediate complexes. Chemometrics are used to further elucidate the reaction pathway from UF 6 to UO 2 F 2 .

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Forecasting Dynamic Line Rating with Spatial Variation Considerations

Dynamic line rating (DLR) is a technology that allows the ampacity of an electrical conductor to be calculated using real-time or forecasted weather conditions. Historically, the ampacity of a conductor has been determined using a static line rating method which assumes conservative weather assumptions. Therefore, not only can DLR give a more accurate measurement of the true ampacity of a conductor, but it can also increase its ampacity during weather conditions with greater thermal mitigations. The two primary cooling factors in the ampacity calculations are wind speed and direction. In complex terrain, wind speed and direction can have large variations over short distances. Therefore, accurately identifying the limiting span of a transmission line requires high spatial resolution of the wind along its path. One solution is to install dense weather stations along their path, though this can become costly over long distances. Therefore, researchers have investigated the use of Computation Fluid Dynamic (CFD) simulations to accurately compute the wind field along the path of a transmission line and use these results to identify the limiting section of the conductor. This work presents a case study that evaluates the coupling of CFD simulations and forecasted weather simulations using the High-Resolution Rapid Refresh (HRRR) model points over a 2-year span within a region in south eastern Idaho. The primary goal of the work is the evaluation of the number of HRRR model points used, i.e., weather stations, along the path of the line and the accuracy of the resulting DLR ampacity. This was done using 4, 10, 17, 26, and 35 HRRR model points along two transmission line paths. The results indicate that as the number of model points are increased, the DLR ampacity of the lines decrease, yet converge as more points are added and demonstrate little change with additional HRRR points. It is expected that these results can help transmission line operators identify the number of weather stations that must be installed when coupled with CFD simulations and DLR ampacity to ensure accurate ratings and safe operations.

17 WIND ENERGY↗

Forecasting Dynamic Line Rating with Spatial Variation Considerations

Dynamic line rating (DLR) is a technology that allows the ampacity of an electrical conductor to be calculated using real-time or forecasted weather conditions. Historically, the ampacity of a conductor has been determined using a static line rating method which assumes conservative weather assumptions. Therefore, not only can DLR give a more accurate measurement of the true ampacity of a conductor, but it can also increase its ampacity during weather conditions with greater thermal mitigations. The two primary cooling factors in the ampacity calculations are wind speed and direction. In complex terrain, wind speed and direction can have large variations over short distances. Therefore, accurately identifying the limiting span of a transmission line requires high spatial resolution of the wind along its path. One solution is to install dense weather stations along their path, though this can become costly over long distances. Therefore, researchers have investigated the use of Computation Fluid Dynamic (CFD) simulations to accurately compute the wind field along the path of a transmission line and use these results to identify the limiting section of the conductor. This work presents a case study that evaluates the coupling of CFD simulations and forecasted weather simulations using the High-Resolution Rapid Refresh (HRRR) model points over a 2-year span within a region in south eastern Idaho. The primary goal of the work is the evaluation of the number of HRRR model points used, i.e., weather stations, along the path of the line and the accuracy of the resulting ampacity. This was done using 4, 10, 17, 26, and 35 HRRR model points along two transmission line paths. The results indicate that as the number of model points are increased, the DLR ampacity of the lines decrease, yet converge as more points are added and demonstrate little change with additional HRRR points. It is expected that these results can help transmission line operators identify the number of weather stations that must be installed when coupled with CFD simulations and DLR ampacity to ensure accurate ratings and safe operations.

17 WIND ENERGY↗

Thermal and Mechanical Design of a High-Voltage Power Electronics Package: Preprint

Thermal and mechanical design aspects of a power electronic package with 5-kV GaN devices are presented. Through finite element analyses, the impact of different cooling configurations and device location on the thermal performance and reliability of the package was investigated. It was found that placing the devices closer to the direct-bond-copper substrate as opposed to a centered approach in the proposed double-sided-cooling configuration resulted in improved heat dissipation. This approach also reduced the total number of attachment layers, thereby likely improving the reliability of the package. Furthermore, simulations revealed that the device location had a negligible impact on the thermomechanical behavior of the attachment layers, as they are more prone to the local coefficient of thermal expansion mismatch.

27 ARPA - Advanced Research Projects Agency-Energy↗

Warming effects on grassland soil microbial communities are amplified in cool months

Abstract Global warming modulates soil respiration (RS) via microbial decomposition, which is seasonally dependent. Yet, the magnitude and direction of this modulation remain unclear, partly owing to the lack of knowledge on how microorganisms respond to seasonal changes. Here, we investigated the temporal dynamics of soil microbial communities over 12 consecutive months under experimental warming in a tallgrass prairie ecosystem. The interplay between warming and time altered (P < 0.05) the taxonomic and functional compositions of microbial communities. During the cool months (January to February and October to December), warming induced a soil microbiome with a higher genomic potential for carbon decomposition, community-level ribosomal RNA operon (rrn) copy numbers, and microbial metabolic quotients, suggesting that warming stimulated fast-growing microorganisms that enhanced carbon decomposition. Modeling analyses further showed that warming reduced the temperature sensitivity of microbial carbon use efficiency (CUE) by 28.7% when monthly average temperature was low, resulting in lower microbial CUE and higher heterotrophic respiration (Rh) potentials. Structural equation modeling showed that warming modulated both Rh and RS directly by altering soil temperature and indirectly by influencing microbial community traits, soil moisture, nitrate content, soil pH, and gross primary productivity. The modulation of Rh by warming was more pronounced in cooler months compared to warmer ones. Together, our findings reveal distinct warming-induced effects on microbial functional traits in cool months, challenging the norm of soil sampling only in the peak growing season, and advancing our mechanistic understanding of the seasonal pattern of RS and Rh sensitivity to warming.

54 ENVIRONMENTAL SCIENCES↗

Localized mix-induced radiative cooling in a capsule implosion at the National Ignition Facility

In this work, w present direct measurements of electron temperature variations within an inertially confined deuterium-tritium plasma caused by localized mix of higher-Z materials into the central hot spot. The data are derived from newly developed differentially filtered penumbral imaging of the bremsstrahlung continuum emission. Our analysis reveals distinct localized emitting features in the stagnated hot-spot plasma, and we infer spatial variations in the electron temperature: the mixed region is 660±130eV colder than the surrounding hot-spot plasma at 3.26±0.11keV. Our analysis of the energy flow shows that we measure approximately steady-state conditions where the radiative losses in the mix region are balanced by heat conduction from the surrounding hot deuterium-tritium plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reduced Energy Demand for Cooling with the Sky

This project demonstrated the use of SkyCool’s Passive Daytime Radiative Cooling panels to improve the energy efficiency of cooling systems at Ft Moore, GA. These panels work by passively emitting heat to the sky during the day even under direct sunlight.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental Investigation of Sweeping Jet Film Cooling in a Transonic Turbine Cascade

Abstract The sweeping jet (SJ) film cooling hole has shown promising cooling performance compared to the standard shaped hole in low-speed conditions. The present work demonstrates the first attempt of SJ film cooling at an engine relevant Mach number. An experimental investigation was conducted to study the SJ film cooling on a nozzle guide vane suction surface. A well-established additive manufacturing technique commonly known as stereolithography (SLA) was utilized to design a transonic, engine representative vane geometry in which a row of SJ holes was used on the vane suction surface. Experiments were performed in a linear transonic cascade at an exit Mach number of 0.8 and blowing ratios of BR = 0.25–2.23. The measurement of heat transfer was conducted with the transient IR method, and the convective heat transfer coefficient (HTC) and adiabatic film cooling effectiveness were estimated using a dual linear regression technique (DLRT). Aerodynamic loss measurements were also performed with a total pressure Kiel probe at 0.25Cax downstream of the exit plane of the vane cascade. Experiments were also conducted for a baseline-shaped hole (777-hole) for a direct comparison. Results showed that the SJ hole has a wider coolant spreading in the lateral direction near the hole exit due to its sweeping motion that improves the overall cooling performance particularly at high blowing ratios (BR > 1). Aerodynamic loss measurement suggested that the SJ hole has a comparable total pressure loss to the 777-shaped hole.

Engineering↗

Warm Arctic, Cold Siberia Pattern: Role of Full Arctic Amplification Versus Sea Ice Loss Alone

The effect of future Arctic amplification (AA) on the extratropical atmospheric circulation remains unclear in modeling studies. Using a collection of coordinated atmospheric and coupled global climate model perturbation experiments, we find an emergent relationship between the high-latitude 1,000–500 hPa thickness response and an enhancement of the Siberian High in winter. This wave number-1-like sea level pressure anomaly pattern is linked to an equatorward shift of the eddy-driven jet and a dynamical cooling response in eastern Asia. Additional simulations, where AA is imposed directly into the model domain by nudging, demonstrate how the sea ice forcing is insufficient by itself to capture the vertical extent of the warming and by extension the amplitude of the response in the Siberian High. Additionally, this study demonstrates the importance of the vertical extent of the tropospheric warming over the polar cap in revealing the “warm Arctic, cold Siberia” anomaly pattern in future projections.

54 ENVIRONMENTAL SCIENCES↗

Scalable, low-cost ink-based processing of high-performance silver selenide thermoelectrics

The growing global energy demand and its accelerating contribution to climate change emphasize the urgent need for sustainable energy conversion/harvesting technologies. Thermoelectric (TE) devices offer a compelling route to directly convert waste heat into electricity and enable solid-state cooling without moving parts or harmful refrigerants. Achieving their full potential requires not only higher TE performance (zT) but also scalable, low-cost manufacturing processes. Here, we introduce a transformative ink-based processing approach for scalable manufacturing of high-performance silver selenide-based TE materials and devices. Using a simple, high-throughput ink-mixing and blade coating strategy, our Ag 2 Se-based materials under the optimized composition and processing conditions yield an ultrahigh room-temperature power factor of 2.8 mW m −1 K −2 , over 100% higher than baseline samples and a reproducible figure of merit zT of 1 at room temperature. A thermoelectric generator (TEG) achieves a very competitive power density of 112 mW cm −2 at a 90 °C temperature difference between the hot and cold sides of the device, which is among the highest reported for silver selenide-based TE devices to date. This facile, scalable ink-based processing establishes a practical pathway toward industrial-scale manufacturing and widespread adoption of thermoelectric devices, advancing sustainable energy technologies.

Bappy, Md. Omarsany [University of Notre Dame, IN ↗

Evolution of ferroelastic domain walls during phase transitions in barium titanate nanoparticles

In this work, ferroelastic domain walls inside BaTiO 3 (BTO) tetragonal nanocrystals are distinguished by Bragg peak position and studied with Bragg coherent x-ray diffraction imaging (BCDI). Convergence-related features of the BCDI method for strongly phased objects are reported. A ferroelastic domain wall inside a BTO crystal has been tracked and imaged across the tetragonal-cubic phase transition and proves to be reversible. The linear relationship of relative displacement between two twin domains with temperature is measured and shows a different slope for heating and cooling, while the tetragonality reproduces well over temperature changes in both directions. An edge dislocation is also observed and found to annihilate when heating the crystal close to the phase transition temperature.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetic Field Measurements of First Pre-series Full -Length 4.2 m Quadrupole MQXFA03 Using PCB Rotating Coils for the Hi Hi-Lumi LHC Project

The U.S. Hi-Lumi LHC Accelerator Upgrade Project (AUP) and CERN have joined efforts to develop high field quad-rupoles for the Hi-Lumi LHC upgrade. The US national laborato-ries in the AUP project will deliver 10 magnets and each cryostat has two 4.2 m high gradient quadrupoles in it. These magnets are made of Nb3Sn conductors, with large aperture (150 mm) and in-tegrated gradient of 556.9 T. This paper reports on magnetic measurements performed during the vertical test at Brookhaven National Laboratory (BNL) in 2019-2020. A warm measurement Z-Scan (+/- 15 A) with 42 Z-positions before cool-down was per-formed at BNL. The results were directly compared to field data measured at LBNL during magnet assembly. Measured harmonics and magnetic center offsets (ΔX and ΔY) have provided timely and informative diagnostics on the magnet structure’s shape at both warm and cold temperatures. A new centering fixture was de-signed and added to better center the warm bore tube which con-tains the rotating coil probe. After the quench training to 16.47 kA was achieved, a complete set of cold measurements (Z-Scan at 16.47 kA and I-Scan from 960 A to 16.47 kA and back to 960 A) was made. Periodic axial variation of allowed and nonallowed harmonics was observed which is related to the coil radial and/or mid-plane variations along the magnet axis. Overall, the average harmonics in the straight section are within the required field boundaries.

43 PARTICLE ACCELERATORS↗

SR19036 Improve TRP Cutter Head Performance

The Target Rod Preparation (TRP) cutter head motor suffers from overheating problems during Tritium Producing Burnable Absorber Rods (TPBAR) breaching operations. The TRP cell cutter head drive motor must remain below the administrative limit of 100°C during breaching operations. If temperatures in excess of 100°C are reached, work must be stopped, and the motor allowed to cool. The work stoppage due to overheating of the drive motor directly and drastically lowers the efficiency of the TPBAR breaching process, reducing the production of Tritium gas. Due to the increased need for Tritium gas, the overheating problem must be addressed to improve the overall efficiency of the TPBAR breaching process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Dynamic Modeling of Power Conversion Stages for an Exascale Supercomputer

In this paper a power conversion and energy consumption model for an exascale supercomputer is investigated. Power consumption, energy loss and efficiency are derived for the 27.2 MW liquid-cooled, centralized, High Performance Computing (HPC) power system, which is supplied directly from the 480 V three-phase mains. Two energy conversion stages are analyzed, measured and modeled. The model is developed in order to be adapted and implemented in a digital twin platform utilizing a Resource Allocator and Power Simulator (RAPS) module. RAPS enables estimation of potential energy savings in the direct AC power supply architecture via both conventional rectifier load sharing (commonly used in HPC systems), as well as smart rectifier load sharing. Moreover, besides the direct AC supply architecture analysis, the full direct DC supply architecture with with 1 kV DC bus were also studied. Comparison of 10 hour time frame operation of the system, with direct 480 V AC voltage supply with conventional and smart load sharing and medium dc voltage supply were done. For the direct AC supply architecture, with conventional and smart load sharing the predicted power loss was approximately 840 kW and 820 kW, respectively and the predicted total system efficiency was 92.87% and 93.05%, respectively. For the direct DC supply architecture with the 1000 V DC supply bus power loss was approximately 340 kW and the predicted total system efficiency was 97.02%.

Wojda, Rafal↗