Search NASA⌕ Search

SEARCH · Search NASA

Results for “energy conservation code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Energy Savings Analysis: 2018 IECC for Residential Buildings

DOE and Pacific Northwest National Laboratory (PNNL) conducted a technical analysis to determine energy savings for the 2018 IECC residential provisions relative to the previous edition, the 2015 IECC. This report documents the methodology used to conduct the analysis and summarizes the results and findings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Commercial Building Energy Code Field Study (Final Report)

What is the dollar value of increasing compliance with the energy code? Ultimately, this is the question that policy makers, funders, and program implementers care about. With this in mind, Pacific Northwest National Laboratory (PNNL) developed a new methodology capable of determining how much energy cost savings could potentially be gained through better compliance with the code (Rosenberg et al. 2016). On March 2, 2016 DOE issued Funding Opportunity Announcement (FOA) Number DE-FOA-0001532, requesting proposals to develop and test a methodology for identifying the commercial energy code requirements that can provide the maximum cost-effective energy and cost savings through increased compliance. Awarded to the Institute for Market Transformation, this report summarizes the development and testing of a commercial code compliance methodology, including a summary of results, statistical analysis of sample, and best practices for others implementing a commercial energy code compliance field study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Scalable Reactive Molecular Dynamics Simulations for Computational Synthesis

Reactive molecular dynamics (MD) simulation is a powerful research tool for describing chemical reactions. We eliminate the speed-limiting charge iteration in MD with a novel extended-Lagrangian scheme. The extended-Lagrangian reactive MD (XRMD) code drastically improves energy conservation while substantially reducing time-to-solution. Furthermore, we introduce a new polarizable charge equilibration (PQEq) model to accurately predict atomic charges and polarization. The XRMD code based on hybrid message passing+multithreading achieves a weak-scaling parallel efficiency of 0.977 on 786 432 IBM Blue Gene/Q cores for a 67.6 billion-atom system. The performance is portable to the second-generation Intel Xeon Phi, Knights Landing. Blue Gene/Q simulations for the computational synthesis of materials via novel exfoliation mechanisms for synthesizing atomically thin transition metal dichalcogenide layers will dominate nanomaterials science in this century.

Simulation, Modeling, Performance, and Visualizati↗

BEPAM Model Code and CABBI Simulation Results for "Assessing the Returns to Land and Greenhouse Gas Savings from Producing Energy Crops on Conservation Reserve Program Land"

This dataset contains BEPAM model code and input data to the replicate the results for "Assessing the Returns to Land and Greenhouse Gas Savings from Producing Energy Crops on Conservation Reserve Program Land." The dataset consists of: (1) The replication codes and data for the BEPAM model. The code file is named as output_0213-2020_Complete_daycent-agversion-[rental payment level]%_[biomass price].gms. (BEPAM-CRP model-Sep2020.zip) (2) Simulation results from the BEPAM model (BEPAM_Simulation_Results.csv) * Item (1) is in GAMS format. Item (2) is in text format.

biomass price↗

Viscous Heating At Stagnation In Z-Pinches

The viscous heating associated with m = 0 MHD instabilities in the stagnated Z-pinch is developed further. It would appear that the larger numerical (Neumann) viscosity plus De Bar corrections in simulation codes to yield energy conservation might be another way of representing viscous heating, but in this case the viscosity is inserted to smooth shock discontinuities. However the viscous heating per unit volume appears to be independent of the coefficient of viscosity itself because the fastest growing MHD mode is itself determined by the viscous damping. Therefore it could be argued that, though the correct physics is not in the codes, the resulting heating is not sensitive to the fact that numerical viscosity instead is employed. In addition, by chance, the model of magnetic bubbles first introduced by Lovberg et al. and Riley et al., and later by Rudakov et al. to explain phenomenologically extra heating of the ions leads to the same heating rate as in Haines et al. For the stainless steel array in which T{sub i} was predicted and measured to be >200 KeV while T{sub e} = 3 KeV the ion viscous heating is dominant. However, for the low current experiment by Kroupp et al. in which the ion kinematic viscosity is much smaller than the resistive diffusivity there is resistive damping of MHD modes, and no ions viscous heating should be expected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Duct System Flammability and Air Sealing Fire Separation Assemblies in the International Residential Code

IBACOS identified two barriers that limit the ability of builders to cost-effectively achieve higher energy efficiency levels in housing. These are the use of duct system materials that inherently achieve airtightness and are appropriately sized for low-load houses and the ability to air seal fire separation assemblies. The issues identified fall into a gray area of the codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Resolution requirements for energy conservation in kinetic plasma simulations

The kinetic codes used to model the coupled dynamics of electromagnetic fields and charged particle transport have requirements for spatial, temporal, and charge resolution. These requirements may vary by the solution technique and scope of the problem. In this report, we investigate the resolution limits in the energy-conserving implicit particle-in-cell code CHICAGO. This report has the narrow aim of determining the maximum acceptable grid spacing for the dense plasmas generated in models of z-pinch target gases and power-flow electrode plasmas. In the 2D sample problem, the plasma drifts without external forces with velocity of 10 cm/µs. Simulations are scaled by plasma density to maintain uniform strides across the plasma and from the plasma to the boundaries. Additionally, the cloud-in-cell technique is used with 400 particles per cell and Δ t = 0.85× the Courant limit. For the linear cloud distribution, the criterion for conserving energy is Δ E/E tot < 0.01 for 50,000 time steps. The grid resolution is determined to crudely be Δx ≲ 3 l s , where l s is the electron collisionless skin depth. For the second-order cloud distribution the criterion is Δ E/E tot < 0.005 yielding Δx ≤ 15 l s . These scalings are functions of the chosen v d , Δ t , particles-per-cell, and number of steps.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Duct System Flammability and Air Sealing Fire Separation Assemblies in the International Residential Code

IBACOS identified two barriers that limit the ability of builders to cost-effectively achieve higher energy efficiency levels in housing. These are (1) the use of duct system materials that inherently achieve airtightness and are appropriately sized for low-load houses and (2) the ability to air seal fire separation assemblies. The issues identified fall into a gray area of the codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Squeezing more light out of tighter energy codes

This article discusses what builders and contractors should know about the various code requirements and their intent, exemptions, and allowances to streamline compliance. In order to cover most code applications, this article will focus on the ANSI/ASHRAE/IESNA 90.1 Standard and the IECC code.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Alabama Energy Code Compliance Project

The U.S. Department of Energy (DOE) Building Energy Codes Program launched a series of research studies in 2014 across eight U.S. states (shown in Figure 1) to investigate typical energy efficiency practices in residential buildings and identify opportunities to reduce household utility bills. A primary goal of the study was to help document baseline practices for new single-family construction, target areas for improvement relative to the state energy code, and quantify the related savings potential. This information is intended to assist states in measuring compliance with their energy codes and to identify areas of focus for future education and training initiatives. Following the original baseline studies, project teams in each state conducted a series of education, training, and outreach activities aimed at improving compliance with the state residential energy code. A second baseline study was then implemented in each state with the objective of determining whether the investment in education, training, and outreach programs had produced a significant and measurable change in statewide residential energy use. Through the program, DOE planned to establish a sufficient data set to represent baseline construction trends across states and detect significant changes in energy use resulting from education and training activities. This report outlines the application of the study in the state of Alabama, which was led by the Institute for Market Transformation (IMT). Data gathered have been submitted to Pacific Northwest National Laboratory (PNNL) for analysis. Findings available to date are published as PNNL technical reports on the DOE Building Energy Codes Program website.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Montana Residential Energy Code Field Study

A research project in the state of Montana identified opportunities to reduce homeowner utility bills in residential single-family new construction by increasing compliance with the state energy code. The study was initiated in May 2018; data collection began in June 2018 and continued through September 2018. Analysis of the data has led to a better understanding of the energy features present in homes and identified nearly $192,000 in potential annual savings to Montana homeowners that could result from increased compliance with the Montana Residential Energy Code.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Particle-in-cell simulations of burning inertial confinement fusion capsule implosions

Anomalies observed in the neutron spectral shift of high-yield shots at the National Ignition Facility (NIF) suggest the presence of suprathermal ions [E. P. Hartouni et al., Nat. Phys. 19, 72 (2023)], implying that kinetic effects play a significant role in burning inertial confinement fusion (ICF) plasmas. Furthermore, recent measurements of reaction-in-flight (RIF) neutrons offer a direct probe of the stopping power in the burning fuel region of high-energy alpha particles and up-scattered fuel ions. We have developed the particle-in-cell code PICNIC, an exactly energy-conserving particle-in-cell Monte-Carlo collision (PIC-MCC) code to simulate the burn stage in ICF. We present results from 1D spherical simulations of NIF shot N210808, which was the first to exceed the Lawson criterion for laser fusion. We find that the suprathermal ions generated by large-angle Rutherford and nuclear elastic scattering (NES) with fusion alphas produce an alpha knock-on neutron (AKN) signal consistent with the extent and relative yield of the AKN spectrum identified in ignition experiments at the NIF. Furthermore, we also find that the inclusion of large-angle scattering physics does not explain the anomalously large spectral shift observed in the experiment.

High-energy-density plasmas↗

Inspecting to the Commercial Energy Code Provisions

This article is on inspecting to the commercial energy provisions. This article provides an overview of how to plan, review and inspect to the commercial energy provisions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Jackson Park Hospital Green Building Medical Center

Jackson Park Hospital completed the construction of a new Medical Office Building on its campus this spring. The new building construction has adopted the City of Chicago's recent focus on protecting the environment, and conserving energy and resources, with the introduction of green building codes. Located in a poor, inner city neighborhood on the South side of Chicago, Jackson Park Hospital has chosen green building strategies to help make the area a better place to live and work. The new green building houses the hospital's Family Medicine Residency Program and Specialty Medical Offices. The residency program has been vital in attracting new, young physicians to this medically underserved area. The new outpatient center will also help to allure needed medical providers to the community. The facility also has areas designated to women's health and community education. The Community Education Conference Room will provide learning opportunities to area residents. Emphasis will be placed on conserving resources and protecting our environment, as well as providing information on healthcare access and preventive medicine. The new Medical Office Building was constructed with numerous energy saving features. The exterior cladding of the building is an innovative, locally-manufactured precast concrete panel system with integral insulation that achieves an R-value in excess of building code requirements. The roof is a 'green roof' covered by native plantings, lessening the impact solar heat gain on the building, and reducing air conditioning requirements. The windows are low-E, tinted, and insulated to reduce cooling requirements in summer and heating requirements in winter. The main entrance has an air lock to prevent unconditioned air from entering the building and impacting interior air temperatures. Since much of the traffic in and out of the office building comes from the adjacent Jackson Park Hospital, a pedestrian bridge connects the two buildings, further decreasing the amount of unconditioned air that enters the office building. The HVAC system has an Energy Efficiency Rating 29% greater than required. No CFC based refrigerants were used in the HVAC system, thus reducing the emission of compounds that contribute to ozone depletion and global warming. In addition, interior light fixtures employ the latest energy-efficient lamp and ballast technology. Interior lighting throughout the building is operated by sensors that will automatically turn off lights inside a room when the room is unoccupied. The electrical traction elevators use less energy than typical elevators, and they are made of 95% recycled material. Further, locally manufactured products were used throughout, minimizing the amount of energy required to construct this building. The primary objective was to construct a 30,000 square foot medical office building on the Jackson Park Hospital campus that would comply with newly adopted City of Chicago green building codes focusing on protecting the environment and conserving energy and resources. The energy saving systems demonstrate a state of the-art whole-building approach to energy efficient design and construction. The energy efficiency and green aspects of the building contribute to the community by emphasizing the environmental and economic benefits of conserving resources. The building highlights the integration of Chicago's new green building codes into a poor, inner city neighborhood project and it is designed to attract medical providers and physicians to a medically underserved area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Semi-coupled flow and thermal analysis of the field joint during rapid pressurization of the redesigned solid rocket motor

A transient, semi-coupled, multi-dimensional thermal and flow analysis methodology was developed to predict the thermal/gas dynamic conditions in the field joint region of the Redesigned Solid Rocket Motor (RSRM). Transient temperature response, pressure history, and combustion gas flow rate (within the field joint region), were of principle interest, in the course of this study. The thermal environment in the field joint was modeled using SINDA, a finite difference based thermal network analyzer. The combustion gas flow boundary condition was generated using the FLAP code; this code performs a transient, lumped-parameter, control volume analysis to solve the mass, momentum, and energy conservation equations. The FLAP computer code was modified to account for erosion of the NBR insulation material, following ignition. An independent grid sensitivity study was conducted to determine an appropriate grid distribution near the wall. The predicted results, obtained using an optimum grid distribution and computer generated flow boundary condition, were compared with subscale test data.

Ghaffarian, Benny↗

DRACS thermal performance evaluation for FHR

Direct Reactor Auxiliary Cooling System (DRACS) is a passive decay heat removal system proposed for the Fluoride-salt-cooled High-temperature Reactor (FHR) that combines coated particle fuel and a graphite moderator with a liquid fluoride salt as the coolant. The DRACS features three coupled natural circulation/convection loops, relying completely on buoyancy as the driving force. These loops are coupled through two heat exchangers, namely, the DRACS Heat Exchanger and the Natural Draft Heat Exchanger. In addition, a fluidic diode is employed to minimize the parasitic flow into the DRACS primary loop and correspondingly the heat loss to the DRACS during normal operation of the reactor, and to keep the DRACS ready for activation, if needed, during accidents. To help with the design and thermal performance evaluation of the DRACS, a computer code using MATLAB has been developed. This code is based on a one-dimensional formulation and its principle is to solve the energy balance and integral momentum equations. By discretizing the DRACS system in the axial direction, a bulk mean temperature is assumed for each mesh cell. The temperatures of all the cells, as well as the mass flow rates in the DRACS loops, are predicted by solving the governing equations that are obtained by integrating the energy conservation equation over each cell and integrating the momentum conservation equation over each of the DRACS loops. In addition, an intermediate heat transfer loop equipped with a pump has also been modeled in the code. This enables the study of flow reversal phenomenon in the DRACS primary loop, associated with the pump trip process. Experimental data from a High-Temperature DRACS Test Facility (HTDF) are not available yet to benchmark the code. A preliminary code validation is performed by using natural circulation experimental data available in the literature, which are as closely relevant as possible. The code is subsequently applied to the HTDF that is under construction at the Ohio State University.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Modeling cross-beam energy transfer with sector ray tracing

Ray-based cross-beam energy transfer (CBET) models are an essential feature of the radiation-hydrodynamic codes used to simulate inertial confinement fusion implosions, but full 3D ray-based CBET calculations can have a prohibitively high computational cost. Sector ray tracing can be used to reduce the cost by orders of magnitude in cases where the coronal plasma and laser drive can be approximated as spherically symmetric. An extension of sector ray tracing (section ray tracing) can be used to relax the assumption of a spherically symmetric drive while still retaining most of the computational savings of a sector ray trace. We discuss the foundations of sector and section ray tracing and compare them to full ray tracing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗