Search NASASearch

SEARCH · Search NASA

Results for “energy storage systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,011 records · Page 14

Enhanced Preparation for Intelligent Cybermanufacturing Systems (EPICS)

Opportunities exist for realizing transformative advances in productivity and reductions in energy footprint through ubiquitous sensing in manufacturing environments. Enhanced Preparation for Intelligent Cybermanufacturing Systems (EPICS) is a 21-month (4 academic semesters, plus one summer) experience for graduate students that focuses on scaling the knowledge, understanding and leadership skills in the cyber manufacturing area. Masters students (8/year, 32 total) complete 2-year projects on industrially-driven project topics, rotating to internships in summer semester to work on scoping and implementation at project partners. Students complete academic training in embedded systems, process modeling, data science, and cloud-based systems design. Their projects are targeted toward sensor retrofit, process monitoring, root cause analysis, and sensor fusion.

Advanced Manufacturing

Mechanical, Electrochemical & Thermal Models - Training (CRADA CRD-19-00798 Final Report)

Under the proposed effort in partnership with Hyundai Motor Company (HMC), the National Renewable Energy Laboratory (NLR) will host Dr. Jaeyoung Lim from HMC for a period of one year to jointly develop mathematical models for battery cells and modules subject to mechanical crush. NLR will assist with the development of mathematical models that Dr. Lim will incorporate into his research effort on new concepts of mobility with electric vehicles.

33 ADVANCED PROPULSION SYSTEMS

RMCProfile7 : reverse Monte Carlo for multiphase systems

This work introduces a completely rewritten version of the programRMCProfile(version 7), big-box, reverse Monte Carlo modelling software for analysis of total scattering data. The major new feature ofRMCProfile7is the ability to refine multiple phases simultaneously, which is relevant for many current research areas such as energy materials, catalysis and engineering. Other new features include improved support for molecular potentials and rigid-body refinements, as well as multiple different data sets. An empirical resolution correction and calculation of the pair distribution function as a back-Fourier transform are now also available.RMCProfile7is freely available for download at https://rmcprofile.ornl.gov/.

Chemistry

SQUID Readout of a High-$Q$ Superconducting $LC$ Resonator

We demonstrate the readout of a superconducting $LC$ resonator, with $Q \approx 2 \times 10^{6}$ at approximately 250 kHz, using a dc SQUID followed by a SQUID series-array amplifier readout chain. We find that $Q$ depends on the SQUID flux-bias point, increasing near the shallow-slope point of the SQUID modulation curve and decreasing near the steep-slope point, consistent with the previously observed SQUID damping effects. From this variation, we infer the SQUID effective input impedance. We further infer the effective temperature of the resonator circuit from the resonance peak in the noise spectrum and show that it also depends on the SQUID flux-bias point, suggesting a possible contribution from SQUID back-action noise. This system provides a working prototype for future experiments based on lumped-element resonators with SQUID readout, in particular low-mass axion searches within the DMRadio program.

FOS: Physical sciences

Tokamak Energy’s pre-concept design for a fusion power plant: an overview of ST-E1

Climate change and rapidly rising energy demand, driven in part by artificial intelligence and data-centre growth, create an urgent need for stable, low-carbon, and abundant power. Fusion is a promising long-term solution, yet its commercialisation faces a fundamental paradox in today’s investment environment: pilot plants are essential to de-risk physics, engineering, and operations, but their limited lifetime energy output and high upfront costs make them difficult to finance. This paper presents Tokamak Energy’s response: ST-E1, a pre-concept design for a low-aspect-ratio tokamak power plant engineered specifically to overcome this challenge. ST-E1 is designed from the outset for phased operation—pilot and commercial phases, with an upgrade phase in between—with emphasis on commercial viability, maintainability, nuclear engineering, modularity, and upgradability. A key design principle is the deliberate separation of long-lived assets, such as the magnet cage and vacuum vessel, from replaceable in-vessel systems. This provides an attractive and credible investment approach to generate operational data and de-risk key technologies while preserving most capital-intensive assets for later commercial phases. The architecture supports continuous optimisation toward high net electric power (targeting 800–1000 MW net electric), a normalised capital expenditure of $\$$ 12–14k/kW of net electric power, and high availability (targeting > 80%). A tokamak core with a 5 m major radius, aspect ratio of 2.3, and on-plasma axis toroidal field of 5.25 T was selected to meet these objectives. This paper summarises the ST-E1 design philosophy, principal features, and development methodology. It introduces a Focus Collection of 11 papers detailing the pre-concept design of the entire tokamak and corresponding plant.

ST-E1

From Pollutant Removal to Renewable Energy: MoS2-Enhanced P25-Graphene Photocatalysts for Malathion Degradation and H2 Evolution

The widespread presence of pesticides—especially malathion—in aquatic environments presents a major obstacle to conventional remediation strategies, while the ongoing global energy crisis underscores the urgency of developing renewable energy sources such as hydrogen. In this context, photocatalytic water splitting emerges as a promising approach, though its practical application remains limited by poor charge carrier dynamics and insufficient visible-light utilization. Herein, we report the design and evaluation of a series of TiO2-based ternary nanocomposites comprising commercial P25 TiO2, reduced graphene oxide (rGO), and molybdenum disulfide (MoS2), with MoS2 loadings ranging from 1% to 10% by weight. The photocatalysts were fabricated via a two-step method: hydrothermal integration of rGO into P25 followed by solution-phase self-assembly of exfoliated MoS2 nanosheets. The composites were systematically characterized using X-ray diffraction (XRD), Raman spectroscopy, transmission electron microscopy (TEM), UV-Vis diffuse reflectance spectroscopy (DRS), and photoluminescence (PL) spectroscopy. Photocatalytic activity was assessed through two key applications: the degradation of malathion (20 mg/L) under simulated solar irradiation and hydrogen evolution from water in the presence of sacrificial agents. Quantification was performed using UV-Vis spectroscopy, gas chromatography–mass spectrometry (GC-MS), and thermal conductivity detection (GC-TCD). Results showed that the integration of rGO significantly enhanced surface area and charge mobility, while MoS2 served as an effective co-catalyst, promoting interfacial charge separation and acting as an active site for hydrogen evolution. Nearly complete malathion degradation (~100%) was achieved within two hours, and hydrogen production reached up to 6000 µmol g−1 h−1 under optimal MoS2 loading. Notably, photocatalytic performance declined with higher MoS2 content due to recombination effects. Overall, this work demonstrates the synergistic enhancement provided by rGO and MoS2 in a stable P25-based system and underscores the viability of such ternary nanocomposites for addressing both environmental remediation and sustainable energy conversion challenges.

Chemistry

Lessons learned from the development and implementation of a workforce training curriculum for advanced controls for high performance HVAC systems

Over the past decade, academic research on advanced controls has slowly transitioned into new software platforms, giving rise to various companies developing and deploying these innovative products, including solutions for light commercial HVAC systems. However, the current workforce remains widely unprepared to install, maintain and operate these systems, particularly complex software-based control platforms, as most workforce training programs still focus on traditional building automation for large commercial buildings. This paper presents the development and piloting of curriculum for three key types of professionals: ● Technicians (trade-level): installing and maintaining modern high-performance HVAC systems and controls ● Programmers (undergrad-level): developing and implementing advanced controls ● Engineers and energy professionals (undergrad/grad-level): managing and evaluating system performance We share details of the material developed including training videos, open-source software, instruction manuals. We also present the results of a pilot implementation of the training materials with real students.

Casillas, Armando

Framework of compressive sensing and data compression for 4D-STEM

Four-dimensional Scanning Transmission Electron Microscopy (4D-STEM) is a powerful technique for high-resolution and high-precision materials characterization at multiple length scales, including the characterization of beam-sensitive materials. However, the field of view of 4D-STEM is relatively small, which in absence of live processing is limited by the data size required for storage. Furthermore, the rectilinear scan approach currently employed in 4D-STEM places a resolution- and signal-dependent dose limit for the study of beam sensitive materials. Improving 4D-STEM data and dose efficiency, by keeping the data size manageable while limiting the amount of electron dose, is thus critical for broader applications. Here we introduce a general method for reconstructing 4D-STEM data with subsampling in both real and reciprocal spaces at high fidelity. The approach is first tested on the subsampled datasets created from a full 4D-STEM dataset, and then demonstrated experimentally using random scan in real-space. The same reconstruction algorithm can also be used for compression of 4D-STEM datasets, leading to a large reduction (100 times or more) in data size, while retaining the fine features of 4D-STEM imaging, for crystalline samples.

4D-STEM

Additive‐Free Oxidized Spiro‐MeOTAD Hole Transport Layer Significantly Improves Thermal Solar Cell Stability

Perovskite solar cells are among the most promising new solar technologies, already surpassing polycrystalline silicon solar cell efficiencies. The stability of the highest efficiency devices at elevated temperature is, however, poor. These cells typically use Spiro-MeOTAD as the hole transporting layer. It is generally believed that additives, required for enhancing electrical conductivity and optimizing energy level alignment, are responsible for the reduced stability—inferring that Spiro-MeOTAD based hole transporting layers are intrinsically unstable. Here, a reliable noble metal free synthesis of Spiro-MeOTAD (bis(trifluoromethane)sulfonimide) 4 is presented which is used as the oxidizing agent. No additives are added to the partially oxidized Spiro-MeOTAD hole-transporting layer. Device efficiencies up to 24.2% are achieved. Electrical conductivity is largely developed by the first 1% oxidation. Further oxidation shifts the energy levels away from the vacuum level, which allows tuning of the energy level alignment without the use of additives—contradicting the current understanding of this system. Without additives, devices demonstrate significant improvement in stability at elevated temperatures up to 85 °C under one sun over 1400 h continuous illumination. The remaining degradation is pinpointed to ion migration and reactions in the perovskite layer which may be further suppressed with compositional engineering and adequate ion barrier layers.

14 SOLAR ENERGY

Criteria for Retention of 3013 S1 Containers Based on Relative Risk and Expert Judgment

An evaluation was performed to assess the suitability of thirty-three 3013 containers proposed for retention. These containers have moisture levels greater than 0.08 wt.% – the S1 population. The remainder of the S1 population stored at SRS will be down blended and disposed of by the end of 2028. Based on field surveillance and shelf-life data available to date as well as informed technical judgment, no container is currently expected to fail in its 50-year storage period. However, corrosion risk varies across the S1 population. Relative risks were evaluated using predicted Consensus Scores and their 95% Upper Prediction Limits (UPLs). The predicted values are based on a statistical model of Consensus Score as a function of moisture, chloride, and whether the packaged material was electrorefining scrap packaged at Hanford. Consensus Score has been shown to be a useful indicator of corrosion potential, and the UPL captures uncertainty in the model predictions, providing a conservative indicator of corrosion potential. Using UPLs to determine relative risks, together with expert review, three containers were identified as not suitable for retention, and the remainder were determined to be suitable.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS

A molecular conveyor belt-associated protein controls the rotational direction of the bacterial type 9 secretion system

ABSTRACT Many bacteria utilize the type 9 secretion system (T9SS) for gliding motility, surface colonization, and pathogenesis. This dual-function motor supports both gliding motility and protein secretion, where rotation of the T9SS plays a central role. Fueled by the energy of the stored proton motive force and transmitted through the torque of membrane-anchored stator units, the rotary T9SS propels an adhesin-coated conveyor belt along the bacterial outer membrane like a molecular snowmobile, thereby enabling gliding motion. However, the mechanisms controlling the rotational direction and gliding motility of T9SS remain elusive. Shedding light on this mechanism, we find that in the gliding bacteriumFlavobacterium johnsoniae, deletion of the C-terminus of the conveyor belt-associated protein GldJ controls and, in fact, reverses the rotational direction of T9SS from counterclockwise (CCW) to clockwise (CW). This suggests that the interface between the conveyor belt-associated protein GldJ and the T9SS ring protein GldK plays an important role in controlling the directionality of T9SS, potentially by modulating its interaction with the stator complex GldLM, which drives motor rotation. Combined with MD simulation of the T9SS stator units GldLM, we suggest a “tri-component gearset” model where GldJ controls the rotational direction of its driver, the T9SS, thus providing adaptive sensory feedback to influence the motility of the gliding bacterium. IMPORTANCE The type 9 secretion system (T9SS) is fundamental to bacterial gliding motility, pathogenesis, and surface colonization. Our findings reveal that the C-terminal region of the conveyor belt-associated protein GldJ functions as a molecular switch which is capable of reversing the rotational direction of T9SS. Through the coordinated actions of the T9SS stator units (akin to a driving motor), the GldK ring (the gear that converts rotational energy into linear movement), and GldJ, this machinery forms a smart conveyor belt system reminiscent of flexible or cognitive mechanical conveyors. Such advanced conveyors can alter their direction to adapt to shifting demands. Here, we show that the bacterial T9SS similarly adjusts its rotational bias based on feedback from the conveyor belt-associated protein GldJ. This dual-role feedback mechanism underscores an evolved, controllable biological snowmobile, offering new avenues for studying how bacteria fine-tune motility in dynamic environments.

Microbiology

Electronic glasses from a broken gauge symmetry in disorder-free systems

Glass phases can be stabilized by quenched disorders, as in most spin-glass materials, or self-generated through kinetic freezing in disorder-free systems. A canonical example of the latter is structural glasses, which have been extensively studied for many decades. Yet, how the rugged energy landscape of a glass phase is spontaneously generated in disorder-free systems remains one of the key questions in glass physics. Here, in this work, we present a general electronic mechanism for the emergence of glassy phase using the example of itinerant electrons coupled to XY spins on a lattice. This model can also be viewed as the mean-field theory of a superconducting system with attractive density-density interactions. Intriguingly, the electron gauge symmetry in the strong pairing limit gives rise to a macroscopic degeneracy of XY spins. In the presence of electron hopping that breaks the gauge symmetry, the lifting of the extensive degeneracy leads to a glass phase with disordered pairings. Our findings highlight a scenario in which a glassy state originates from the breaking of quantum gauge symmetry without quenched disorders.

XY model

Reflection and refraction of directrons at the interface

Reflection and refraction are ubiquitous phenomena with extensive applications, yet minimizing energy loss and information distortion during these processes remains a significant challenge. This study examines the behavior of structurally stable solitons, known as directrons, in nematic liquid crystals interacting with an interface where the director field orientation changes, despite identical physical properties, external potentials, and boundary anchoring in the two regions. During reflection and refraction, the directrons maintain nearly constant structure and velocity, ensuring energy conservation and information integrity. Microscopic analyses of the director field and macroscopic evaluations of effective potential are employed to elucidate the dependence of reflection and refraction probabilities on the directron’s incident angle and the orientation difference across the interface. The findings provide valuable insights into the dynamics of solitary waves in structured liquid crystal systems, offering significant implications for the development of tunable photonic devices, reconfigurable optical systems, and nanoscale material engineering.

Science & Technology - Other Topics

Role of Fluid and Temperature in Fracture Mechanics and Coupled THMC Processes for Enhanced Geothermal Systems

The ability to sustain high energy extraction efficiency from Enhanced Geothermal Systems (EGS) is affected by the ability to measure, characterize, and predict the effect of different perturbations that arise from fluid injection rates, fluid temperature, and shut-in conditions on existing and stimulated fracture systems throughout a subsurface reservoir’s lifecycle. The difficulty arises from limited knowledge of the interaction of fluid and temperature driven fractures with frictional interfaces that govern local deformation and frictional behavior in the surrounding rock. Thermo-poro-mechanical coupled processes tend to dominate this interaction and strongly affect the permeability and local stress distributions that impact efficiency and prevent optimal stimulation conditions over multi-decadal time frames.

Pyrak-Nolte, Laura [Purdue Univ., West Lafayette,

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Customizable wave tailoring nonlinear materials enabled by bilevel inverse design

Abstract Passive wave transformation via nonlinearity is ubiquitous in settings from acoustics to optics and electromagnetics. It is well known that different nonlinearities yield different effects on propagating signals, which raises the question of “what precise nonlinearity is the best for a given wave tailoring application?” In this work, considering a one-dimensional spring-mass chain connected by polynomial springs (a variant of the Fermi-Pasta-Ulam-Tsingou system), we introduce a bilevel inverse design method which couples the shape optimization of structures for tailored constitutive responses with reduced-order nonlinear dynamical inverse design. We apply it to two qualitatively distinct problems—minimization of peak transmitted kinetic energy from impact, and pulse shape transformation—demonstrating our method’s breadth of applicability. For the impact problem, we obtain two fundamental insights. First, small differences in nonlinearity can drastically change the dynamic response of the system, from severely under- to outperforming a comparative linear system. Second, the oft-used strategy of impact mitigation via “energy locking” bistability can be significantly outperformed by our optimal nonlinearity. We validate this case with impact experiments and find excellent agreement. This study establishes a framework for broader passive nonlinear mechanical wave tailoring material design, with applications to computing, signal processing, shock mitigation, and autonomous materials.

Science & Technology - Other Topics

A Probabilistic Approach to Load Modeling for Central HVAC Systems in Large Commercial Buildings for Retrofit Decisions Under Uncertainty

Retrofitting central HVAC systems in large commercial buildings with advanced technologies like heat recovery chillers (HRCs) offers a significant opportunity to enhance energy efficiency. However, analyzing these retrofits is challenging with traditional whole-building simulation tools, which require intensive calibration and struggle to model innovative system configurations and controls. To overcome these limitations, this study proposes a load profilebased retrofit analysis framework that provides better decisions under uncertainty. The main focus of this paper is the development of a probabilistic load profile model that can be used in the framework by using exploratory data analysis (EDA) of measured building data to properly quantify its inherent variability. A non-parametric Gaussian Process (GP) model was employed to capture the time- and weather-dependent characteristics of the heating load while explicitly modeling its uncertainty. The model's effectiveness is demonstrated through strong predictive performance on unseen data and physically interpretable insights into load behavior. This data-driven, probabilistic load profile serves as a robust and flexible input for subsequent system simulations, enabling a more confident and statistically sound analysis of retrofit potential.

Ham, S W

Reduced fast-ion transport calculations of m = n = 1 fishbone-like instabilities in MAST-U

Fast-ion transport associated with an m = n = 1 fishbone-like burst in MAST-U discharge 47128 is investigated using a reduced guiding-center-based transport model (ORBIT-Kick) constrained by multi-diagnostic measurements. The two-dimensional beam-emission spectroscopy system provides measurements of the core poloidal mode structure and fluctuation amplitude, while EFIT++ reconstructions constrained by the motional Stark effect diagnostic indicate a flat q-profile with q 0 > 1⁠, indicating the absence of a resonant q = 1 surface and supporting a pressure-driven infernal-mode interpretation. Analytic m = n = 1 displacement profiles consistent with the measured core mode structure and equilibrium constraints are used as the mode structure inputs to ORBIT-Kick. The calculations show that the dominant resonances occur between the mode and co-passing fast ions, producing redistribution localized near the magnetic axis. Synthetic neutron camera signals from TRANSP-Kick recover up to 90% of the experimentally observed neutron deficit at the time of peak mode amplitude, indicating that the measured m = n = 1 mode is a dominant contributor to core fast-ion transport. However, the synthetic neutron signals recover rapidly, whereas the measured neutron emission continues to decrease after the peak amplitude. In conclusion, the remaining discrepancy may arise from contributions not included in the present single-harmonic model, including higher-m and higher-n harmonics, multi-harmonic interactions, and additional transport mechanisms, motivating future diagnostic development and modeling efforts to resolve and incorporate these additional contributions.

Wong, Henry H. [University of California, Los Ange