Search NASA⌕ Search

SEARCH · Search NASA

Results for “experimental setup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Flexibility and utility of pre-processing methods in converting STXM setups for ptychography (Final Paper)

Ptychography is an advanced diffraction based imaging technique that can achieve resolution of 5nm and below. It is done by scanning a sample through a beam of focused x-rays using discrete yet overlapping scan steps. Scattering data is collected on a CCD camera, and the phase of the scattered light is reconstructed with sophisticated iterative algorithms. Because the experimental setup is similar, ptychography setups can be created by retrofitting existing STXM beam lines with new hardware. The other challenge comes in the reconstruction of the collected scattering images. Scattering data must be adjusted and packaged with experimental parameters to calibrate the reconstruction software. The necessary pre-processing of data prior to reconstruction is unique to each beamline setup, and even the optical alignments used on that particular day. Pre-processing software must be developed to be flexible and efficient in order to allow experiments appropriate control and freedom in the analysis of their hard-won data. This paper will describe the implementation of pre-processing software which successfully connects data collection steps to reconstruction steps, letting the user accomplish accurate and reliable ptychography.

43 PARTICLE ACCELERATORS↗

Using Computational Flow Imaging to Optimize Filtered Rayleigh Scattering Measurements of an Isolator Shock Train

Filtered Rayleigh scattering (FRS) is a laser diagnostic where the intensity of elastically scattered light is measured after it passes through a molecular absorption filter. The filter removes background interference that overwhelms the relatively weak scattering from the gas molecules. However, with a filter, the measured light intensity depends on many of the scattering gas properties, including pressure, density, temperature, and velocity. In this work, CFD simulations of an isolator shock train flow field are input into a physics-based model to predict the values of FRS intensity measurements in a proposed experiment. The goal is to evaluate if a simplistic FRS setup (that utilizes one camera, laser, and absorption filter) can be used to accurately quantify number density despite the fact that the scattered light intensity also depends on other gas properties. It is found that the experimental setup can be optimized such that a linear relationship describes the number density with an average prediction error of 2%. The vast majority of the flow exhibits prediction errors of less than 3%, but small regions of the flow reach up to 11% error. A sensitivity analysis shows that the prediction error increases with the central wavelength of the incident laser light and decreases with the angle between the camera and laser propagation directions. The optimal experimental parameters are chosen based on a compromise between the prediction error, spatial resolution, and the amount of unfiltered light. In the future, the proposed FRS setup will be implemented to acquire new and valuable information on an isolator shock train, a flow field that has been traditionally studied using wall static pressure measurements and path-integrated visualization techniques, such as schlieren and shadowgraphy.

Hunt, Robin L.↗

Collaborative Research: Enhancing Laser-Based Ion Sources with High Data Rate Techniques

This collaborative research project focuses on leveraging advanced machine learning techniques to analyze and optimize data from high-repetition-rate laser experiments. The main goal is to apply modern computing hardware, customized data acquisition firmware/software, and machine learning approaches to improve data analysis and experimental control. The project also explores how methodology can be developed on smaller-scale experimental setups and then translated to larger facilities within DOE's LaserNetUS network. With extensive data collection and modeling, the research aims to predict and optimize experimental parameters to enhance performance and efficiency.

47 OTHER INSTRUMENTATION↗

Rocket-Based Combined Cycle Flowpath Testing for Modes 1 and 4

Under sponsorship of the NASA Glenn Research Center (NASA GRC), the Johns Hopkins University Applied Physics Laboratory (JHU/APL) designed and built a five-inch diameter, Rocket-Based Combined Cycle (RBCC) engine to investigate mode 1 and mode 4 engine performance as well as Mach 4 inlet performance. This engine was designed so that engine area and length ratios were similar to the NASA GRC GTX engine is shown. Unlike the GTX semi-circular engine design, the APL engine is completely axisymmetric. For this design, a traditional rocket thruster was installed inside of the scramjet flowpath, along the engine centerline. A three part test series was conducted to determine Mode I and Mode 4 engine performance. In part one, testing of the rocket thruster alone was accomplished and its performance determined (average Isp efficiency = 90%). In part two, Mode 1 (air-augmented rocket) testing was conducted at a nominal chamber pressure-to-ambient pressure ratio of 100 with the engine inlet fully open. Results showed that there was neither a thrust increment nor decrement over rocket-only thrust during Mode 1 operation. In part three, Mode 4 testing was conducted with chamber pressure-to-ambient pressure ratios lower than desired (80 instead of 600) with the inlet fully closed. Results for this testing showed a performance decrease of 20% as compared to the rocket-only testing. It is felt that these results are directly related to the low pressure ratio tested and not the engine design. During this program, Mach 4 inlet testing was also conducted. For these tests, a moveable centerbody was tested to determine the maximum contraction ratio for the engine design. The experimental results agreed with CFD results conducted by NASA GRC, showing a maximum geometric contraction ratio of approximately 10.5. This report details the hardware design, test setup, experimental results and data analysis associated with the aforementioned tests.

Rice, Tharen↗

Comparison of entrainment rates from a tank experiment with results using the one-dimensional turbulence model.

Recent work suggests that cloud effects remain one of the largest sources of uncertainty in model-based estimates of climate sensitivity. In particular, the entrainment rate in stratocumulus-topped mixed layers needs better models. More than thirty years ago a clever laboratory experiment was conducted by McEwan and Paltridge to examine an analog of the entrainment process at the top of stratiform clouds. Sayler and Breidenthal extended this pioneering work and determined the effect of the Richardson number on the dimensionless entrainment rate. The experiments gave hints that the interaction between molecular effects and the one-sided turbulence seems to be crucial for understanding entrainment. From the numerical point of view large-eddy simulation (LES) does not allow explicitly resolving all the fine scale processes at the entrainment interface. Direct numerical simulation (DNS) is limited due to the Reynolds number and is not the tool of choice for parameter studies. Therefore it is useful to investigate new modeling strategies, such as stochastic turbulence models which allow sufficient resolution at least in one dimension while having acceptable run times. We will present results of the One-Dimensional Turbulence stochastic simulation model applied to the experimental setup of Sayler and Breidenthal. The results on radiatively induced entrainment follow quite well the scaling of the entrainment rate with the Richardson number that was experimentally found for a set of trials. Moreover, we investigate the influence of molecular effects, the fluids optical properties, and the artifact of parasitic turbulence experimentally observed in the laminar layer. In the simulations the parameters are varied systematically for even larger ranges than in the experiment. Based on the obtained results a more complex parameterization of the entrainment rate than currently discussed in the literature seems to be necessary.

54 ENVIRONMENTAL SCIENCES↗

Payload vibration isolation in a microgravity environment

Many in-space research experiments require the microgravity environment attainable near the center of mass of the Space Station. Disturbances to the structure surrounding an experiment may lead to vibration levels that will degrade the microgravity environment and undermine the experiment's validity. In-flight disturbances will include vibration transmission from nearby equipment and excitation from crew activity. Isolation of these vibration-sensitive experiments is required. Analytical and experimental work accomplished to develop a payload (experiment) isolation system for use in space is described. The isolation scheme allows the payload to float freely within a prescribed boundary while being kept centered with forces generated by small jets of air. The vibration criterion was a maximum payload acceleration of 10 micro-g's (9.81x10(exp -5)m/s(exp 2), independent of frequency. An experimental setup, composed of a cart supported by air bearings on a flat granite slab, was designed and constructed to simulate the microgravity environment in the horizontal plane. Experimental results demonstrate that the air jet control system can effectively manage payload oscillatory response. An analytical model was developed and verified by comparing predicted and measured payload response. The mathematical model, which includes payload dynamics, control logic, and air jet forces, is used to investigate payload response to disturbances likely to be present in the Space Station.

Alexander, Richard M.↗

Particle Imaging Velocimetry Technique Development for Laboratory Measurement of Fracture Flow Inside a Pressure Vessel Using Neutron Imaging

This paper will describe recent progress made in developing neutron imaging based particle imaging velocimetry techniques for visualizing and quantifying flow structure through a high pressure flow cell with high temperature capability (up to 350 degrees C). This experimental capability has great potential for improving the understanding of flow through fractured systems in applications such as enhanced geothermal systems (EGS). For example, flow structure measurement can be used to develop and validate single phase flow models used for simulation, experimentally identify critical transition regions and their dependence on fracture features such as surface roughness, and study multiphase fluid behavior within fractured systems. The developed method involves the controlled injection of a high contrast fluid into a water flow stream to produce droplets that can be tracked using neutron radiography. A description of the experimental setup will be provided along with an overview of the algorithms used to automatically track droplets and relate them to the velocity gradient in the flow stream. Experimental results will be reported along with volume of fluids based simulation techniques used to model observed flow.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of correlated data in validation procedures - 14483

The increasing demand on accuracy of criticality calculations leads to the question, how to treat correlated data of benchmark experiments correctly. Correlations in the process of validation arise for example if a configuration in a series of experiments shares certain components, e.g. fuel rods. Traditional methods of code validation do not treat correlations explicitly, but give a more conservative estimation of the bias. Including correlations can lead to a more precise estimation. In the work at hand, a method is discussed based on Bayes theorem to include correlations in the experimental data when estimating an application case k{sub eff}. After a short introduction to the applied method and the demonstration of the general capability of it to predict the k{sub eff} correctly, it is shown how the calculated k{sub eff} of an application case depends on correlations in experimental data for a simple Toy Model. The impact of ignoring correlations and taking to account lower and higher correlations is shown and discussed. Further results are shown using a database of correlated experimental data from the International Handbook of Criticality Safety Experiments to estimate the bias of two application cases. The experiments were chosen following the suggestion of the OECD/NEA EGUACSA Benchmark phase IV and consists of 21 experiments from the LEU-COMP-THERM series 007 and 039. With the extracted data results the calculated k{sub eff} values of the application cases are shown and discussed for different examples of correlations. The calculations were done by applying Monte-Carlo sampling methods with the GRS tool SUnCISTT, using ORNL's SCALE 6.1.2. This work discusses a possible way of treating correlations in the recalculation of critical experiments to get a more precise bias estimation of the used code system. It will be shown, that the presented method is capable to treat similarities in experimental setups of data used to calculate the bias correctly, independent of the size of similarities. The presented method is in principle capable of assessing regimes with little experimental data to estimate a bias. (authors)

42 ENGINEERING↗

Path-Integrated X-Ray Images for Multi-Surface Digital Image Correlation (PI-DIC)

X-ray imaging offers unique possibilities for Digital Image Correlation (DIC), opening the door for full-field deformation measurements of a test article in complex environments where optical DIC suffers severe biases or is impossible. While X-ray DIC has been performed in the past with standard DIC codes designed for optical images, the path-integrated nature of X-ray images places constraints on the experimental setup, predominantly that only a single surface of interest moves/deforms. These requirements are difficult to realize for many practical situations and limit the amount of information that can be garnered in a single test. Other X-ray based diagnostics such as Digital Volume Correlation (DVC) and Projection DVC (P-DVC) overcome these obstacles, but DVC is limited to quasi-static tests, and both DVC and P-DVC necessitate high-resolution computed tomography (CT) scan(s) and often require a potentially invasive pattern throughout the volume of the specimen. Here this work presents a novel approach to measure time-resolved displacements and strains on multiple surfaces from a single series of 2D, path-integrated (PI) X-ray images, called PI-DIC. The principle of optical flow or conservation of intensity—the foundation of DIC—was reframed for path-integrated images, for an exemplar setup comprised of two plates moving and deforming independently. Synthetic images were generated for rigid translations, rigid rotations, and uniform stretches, where each plate underwent a unique motion/deformation. Experimental specimens were fabricated (either an aluminum plate with tantalum features or a plastic plate with steel features) and the two specimens were independently translated. PI-DIC was successfully demonstrated with the synthetic images and validated with the experimental images. Prescribed displacements were recovered for each plate from the single set of path-integrated, deformed images. Errors were approximately 0.02 px for the synthetic images with 1.5% image noise, and 0.05 px for the experimental images. These results provide the foundation for PI-DIC to measure motion and deformation of multiple, independent surfaces with subpixel accuracy from a single series of path-integrated X-ray images.

47 OTHER INSTRUMENTATION↗

Measurement of total hemispherical emissivity of contaminated mirror surfaces

The effects of dust contamination on the total hemispherical emissivity (THE) of a 1.5-inch-diameter Al/MgF2-coated telescope mirror are investigated experimentally. The THE is determined by means of cooling-rate measurements in the temperature range 10-14.5 C in a vacuum of 100 ntorr or better. Photographs and drawings of the experimental setup are provided, and results for 11 dust levels are presented in tables and graphs. It is shown that dust has a significant effect on THE, but the experimental losses are only about half those predicted for perfectly black dust in perfect thermal contact with the mirror surface.

Facey, T. A.↗

Role of preparation in quantum process tomography

It was recently pointed out how differences in preparation procedures for quantum experiments can lead to nontrivial differences in the results of the experiment. The differences arise from the initial correlations between the system and the environment. Therefore, any quantum experiment that is prone to influences from the environment must be prepared carefully. We study quantum-process tomography in light of this. We suggest several experimental setups, where preparation of the initial state plays a role in the final outcome of the experiment. By studying the linearity and the positivity of the resulting maps, the experimenter can determine the nature of the initial correlations between the system and the environment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

ACCRUE—An Integral Index for Measuring Experimental Relevance in Support of Neutronic Model Validation

A key challenge for the introduction of any design changes, e.g., advanced fuel concepts, first-of-a-kind nuclear reactor designs, etc., is the cost of the associated experiments, which are required by law to validate the use of computer models for the various stages, starting from conceptual design, to deployment, licensing, operation, and safety. To achieve that, a criterion is needed to decide on whether a given experiment, past or planned, is relevant to the application of interest. This allows the analyst to select the best experiments for the given application leading to the highest measures of confidence for the computer model predictions. The state-of-the-art methods rely on the concept of similarity or representativity, which is a linear Gaussian-based inner-product metric measuring the angle—as weighted by a prior model parameters covariance matrix—between two gradients, one representing the application and the other a single validation experiment. This manuscript emphasizes the concept of experimental relevance which extends the basic similarity index to account for the value accrued from past experiments and the associated experimental uncertainties, both currently missing from the extant similarity methods. Accounting for multiple experiments is key to the overall experimental cost reduction by prescreening for redundant information from multiple equally-relevant experiments as measured by the basic similarity index. Accounting for experimental uncertainties is also important as it allows one to select between two different experimental setups, thus providing for a quantitative basis for sensor selection and optimization. The proposed metric is denoted by ACCRUE, short for Accumulative Correlation Coefficient for Relevance of Uncertainties in Experimental validation. Using a number of criticality experiments for highly enriched fast metal systems and low enriched thermal compound systems with accident tolerant fuel concept, the manuscript will compare the performance of the ACCRUE and basic similarity indices for prioritizing the relevance of a group of experiments to the given application.

97 MATHEMATICS AND COMPUTING↗

The MSAT-X MARECS B2 satellite experiment - Ground segment results

The results of a recently completed satellite experiment employing the JPL MSAT-X developed land-mobile satellite communication terminal are described. In this experiment, a full duplex 4800-b/s digital data and voice communication link was established through the INMARSAT Marecs B2 satellite between Atlantic City, New Jersey, and Southbury, Connecticut. A series of experiments was performed to characterize the terminal performance over this link. The basic experimental setup and the preliminary results of the speech and data experiments are presented. The satellite environment proved to be near to what was expected, and as a result the experimental results were very close to theory/simulation/laboratory experiments. It was found that the ground-to-ground communication links were more benign links than the ground-to-air and air-to-ground links, and this is reflected in the improved margins for the ground-to-ground links (approximately 5 dB versus 3.2 dB for the aeronautical links).

Jedrey, Thomas C.↗

Effect of Variable Gravity on Evaporation of Binary Fluids in a Capillary Pore Evaporator

The research project focuses on experimental investigation of the capillary-pumped evaporative heat transfer phenomenon. The objective is to examine whether the heat transfer and stability of a heated meniscus in a capillary pore can be enhanced by adding trace amounts of a non-volatile solute to a solvent and to understand the changes that occur. The experimental setup consists of a single pore evaporator connected to a reservoir which supplies liquid to the evaporator. In addition to the experiments of capillary-pumped evaporation, a parallel experimental study has been conducted to systematically investigate the effects of gravity as well as the effects of bulk composition on the heat transfer characteristics of evaporating binary thin films near the contact line region along an inclined heated surface. To investigate the buoyancy effects on evaporation along an inclined heated surface, the angle of inclination from a horizontal plane was varied fro 15 C to 90 C. An optimum concentration between 0.5% and 1% decane in pentane/decane solutions has been demonstrated at different angles of inclination. Improved heat transfer was found for the geometry with the smallest angle of inclination of 15 degrees. In addition, flow visualization has revealed that at low inclination angles effective heat transfer takes place primarily due to an extension of the thin film near the contact line. At these low inclination angles, the optimum concentration is associated with enhanced wetting characteristics and reduced thermocapillary stresses along the interface.

Girgis, Morris M.↗

Investigation of SiPM physics parameters down to cryogenic temperatures and for a bio-medical application

Silicon PhotoMultiplier (SiPM) detector has become a suitable visible light/photon detector for many applications like high energy physics and neutrino experiments, fluorescence detection, bio-photonics and medical imaging. The first part of my thesis was oriented to the studies of SiPM physics parameters as a function of temperature. Particularly, recent KETEK devices (year 2015) with different technological characteristics like p/n and n/p junctions, with and without trench technology, and different widths of epitaxial layer were studied in the temperature range from 308.15 K (+35°C) down to 238.15 K (-35°C). In addition, the Hamamatsu devices from 2011 production run as well as new devices from 2015 year, with improved technological characteristics inducing a reduced noise, were investigated in a wider temperature range from 318.15 K (+45°C) down to 98.15 K (-175°C). For these purposes, I participated to the design, installation, commissioning and calibration of a cryogenic experimental setup dedicated to electrical, optical and temperature studies of SiPM devices. Also, I have developed an automatic analysis procedure able to handle in a short time an impressive quantity of experimental data (i.e. tens of Gb/device) and to give a precise and fast information on main SiPM parameters and their temperature dependence. I have also developed a physical modeldescribing the DC I-V curves of SiPM detectors at different temperatures. The proposed model fits well the shape of IV curve in a very large currents range from 10⁻¹² A up to 10⁻⁵ A over the full working range of various devices. Consequently, the IV model can be used as a simple and fast method for determination of SiPM parameters like breakdown voltage VBD, the shape of Geiger triggering probability PGeiger as a function of Vbias as well as the Vbias working range. The comparison of these parameters with those calculated from AC measurements and analyzed by the automatic procedure showed a good agreement. The second part of my thesis was oriented to the study of SiPM devices and their physical parameters required to build a prototype of betasensitive intracerebral probe. Such probe is dedicated to measure the local concentration of radiolabeled molecules on awake and freely moving animal and to study new animal models of human disorders (neurodegenerative diseases, tumor growth, and neuropsychiatric disorders). It is composed of small size, low-noise SiPM device coupled to a scintillating fiber and readout by a dedicated miniaturized low-power consumption electronics. Three SiPM devices have been chosen as the most adapted for our application: two small KETEK devices of 0.5×0.5 mm² size (with and without optical trenches, specially developed by KETEK to fulfill our requirements) and a standard Hamamatsu device of 1.3×1.3 mm² size, all devices having 50 × 50 μm² μcell size. For each SiPM the gain G, dark count rate DCR and beta sensitivity were measured as a function of Vbias and temperature. The obtained results showed that the small field of view and newly developed structure of the KETEK devices allow a large decrease of the dark count rate DCR. However, this small field of view also leads to a reduced light collection due to the thickness of the epoxy protection resin on top of the SiPM and the acceptance angle of the fiber. Since the beta sensitivity represents a tradeoff between photon detection efficiency PDE and dark count rate DCR, KETEK SiPMs exhibit similar performances in comparison with the Hamamatsu device. Preliminary results demonstrate that the beta sensitivity of KETEK devices can be significantly improved by using focusing lens between the scintillating fiber and the SiPM or by reducing the thickness of its epoxy protection resin.

Nagai, Andrii↗

Positron annihilation lifetime spectroscopy using fast scintillators and digital electronics

Positron Annihilation Lifetime Spectroscopy (PALS) is a non-destructive radiological technique widely used in material science studies. PALS typically relies on an analog coincidence measurement setup and allows the estimate of the positron lifetime in a material sample under investigation. The positron trapping at vacancies in the material results in an increased positron lifetime. In this work, we have developed and optimized a PALS experimental setup using organic scintillators, fast digitizers, and advanced pulse processing algorithms. We tested three pairs of different organic scintillators: EJ-309 liquid, EJ-276 newly developed plastic, and BC- 418 plastic, and optimized the data processing parameters for each pair separately. Our high-throughput data analysis method is based on single-pulse interpolation and a constant fraction discrimination (CFD) algorithm. The setup based on the BC-418 detector achieved the best time resolution of 198.3 ± 0.8 ps. We used such optimized setup to analyze two single-crystal quartz samples and found lifetimes of 161 ± 4 ps, 343 ± 12 ps and 1.34 ± 0.05 ns, in good agreement with the characteristic time constants of this material. The proposed experimental set up achieves a time resolution comparable to the minimum positron lifetime in quartz, which makes it possible to accurately characterize material vacancies by discriminating between the lifetimes of either the spin singlet or triplet states of positronium. The optimized data processing algorithms are relevant to all the applications where fast timing is important, such as nuclear medicine and radiation imaging

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron and X-ray Detectors

The Basic Energy Sciences (BES) X-ray and neutron user facilities attract more than 12,000 researchers each year to perform cutting-edge science at these state-of-the-art sources. While impressive breakthroughs in X-ray and neutron sources give us the powerful illumination needed to peer into the nano- to mesoscale world, a stumbling block continues to be the distinct lag in detector development, which is slowing progress toward data collection and analysis. Urgently needed detector improvements would reveal chemical composition and bonding in 3-D and in real time, allow researchers to watch “movies” of essential life processes as they happen, and make much more efficient use of every X-ray and neutron produced by the source The immense scientific potential that will come from better detectors has triggered worldwide activity in this area. Europe in particular has made impressive strides, outpacing the United States on several fronts. Maintaining a vital U.S. leadership in this key research endeavor will require targeted investments in detector R&D and infrastructure. To clarify the gap between detector development and source advances, and to identify opportunities to maximize the scientific impact of BES user facilities, a workshop on Neutron and X-ray Detectors was held August 1-3, 2012, in Gaithersburg, Maryland. Participants from universities, national laboratories, and commercial organizations from the United States and around the globe participated in plenary sessions, breakout groups, and joint open-discussion summary sessions. Sources have become immensely more powerful and are now brighter (more particles focused onto the sample per second) and more precise (higher spatial, spectral, and temporal resolution). To fully utilize these source advances, detectors must become faster, more efficient, and more discriminating. In supporting the mission of today’s cutting-edge neutron and X-ray sources, the workshop identified six detector research challenges (and two computing hurdles that result from the corresponding increase in data volume) for the detector community to overcome in order to realize the full potential of BES neutron and X-ray facilities. Resolving these detector impediments will improve scientific productivity both by enabling new types of experiments, which will expand the scientific breadth at the X-ray and neutron facilities, and by potentially reducing the beam time required for a given experiment. These research priorities are summarized in the table below. Note that multiple, simultaneous detector improvements are often required to take full advantage of brighter sources. High-efficiency hard X-ray sensors: The fraction of incident particles that are actually detected defines detector efficiency. Silicon, the most common direct-detection X-ray sensor material, is (for typical sensor thicknesses) 100% efficient at 8 keV, 25%efficient at 20 keV, and only 3% efficient at 50 keV. Other materials are needed for hard X-rays. Replacement for 3He for neutron detectors: 3He has long been the neutron detection medium of choice because of its high cross section over a wide neutron energy range for the reaction 3He + n —> 3H + 1H + 0.764 MeV. 3He stockpiles are rapidly dwindling, and what is available can be had only at prohibitively high prices. Doped scintillators hold promise as ways to capture neutrons and convert them into light, although work is needed on brighter, more efficient scintillator solutions. Neutron detectors also require advances in speed and resolution. Fast-framing X-ray detectors: Today’s brighter X-ray sources make time-resolved studies possible. For example, hybrid X-ray pixel detectors, initially developed for particle physics, are becoming fairly mature X-ray detectors, with considerable development in Europe. To truly enable time-resolved studies, higher frame rates and dynamic range are required, and smaller pixel sizes are desirable. High-speed spectroscopic X-ray detectors: Improvements in the readout speed and energy resolution of X-ray detectors are essential to enable chemically sensitive microscopies. Advances would make it possible to take images with simultaneous spatial and chemical information. Very high-energy-resolution X-ray detectors: The energy resolution of semiconductor detectors, while suitable for a wide range of applications, is far less than what can be achieved with X-ray optics. A direct detector that could rival the energy resolution of optics could dramatically improve the efficiency of a multitude of experiments, as experiments are often repeated at a number of different energies. Very high-energy-resolution detectors could make these experiments parallel, rather than serial. Low-background, high-spatial-resolution neutron detectors: Low-background detectors would significantly improve experiments that probe excitations (phonons, spin excitations, rotation, and diffusion in polymers and molecular substances, etc.) in condensed matter. Improved spatial resolution would greatly benefit radiography, tomography, phase-contrast imaging, and holography. Improved acquisition and visualization tools: In the past, with the limited variety of slow detectors, it was straightforward to visualize data as it was being acquired (and adjust experimental conditions accordingly) to create a compact data set that the user could easily transport. As detector complexity and data rates explode, this becomes much more challenging. Three goals were identified as important for coping with the growing data volume from high-speed detectors: Facilitate better algorithm development. In particular, algorithms that can minimize the quantity of data stored. Improve community-driven mechanisms to reduce data protocols and enhance quantitative, interactive visualization tools. Develop and distribute community-developed, detector-specific simulation tools. Aim for parallelization to take advantage of high-performance analysis platforms. Improved analysis work flows: Standardize the format of metadata that accompanies detector data and describes the experimental setup and conditions. Develop a standardized user interface and software framework for analysis and data management. The diversity of detector improvements required is necessarily as broad as the range of scientific experimentation at BES facilities. This workshop identified a variety of avenues by which detector R&D can enable enhanced science at BES facilities. The Research Directions listed above will be addressed by focused R&D and detector engineering, both of which require specialized infrastructure and skills. While U.S. leadership in neutron and X-ray detectors lags behind other countries in several areas, significant talent exists across the complex. A forum of technical experts, facilities management, and BES could be a venue to provide further definition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laboratory Measurements of Optical Properties of Micron Size Individual Dust Grains

A laboratory program is being developed at NASA Marshall Space Flight Center for experimental determination of the optical and physical properties individual dust grains in simulated astrophysical environments. The experimental setup is based on an electrodynamic balance that permits levitation of single 0.1 - 10 micron radii dust grains in a cavity evacuated to pressures of approx. 10(exp -6) torr. The experimental apparatus is equipped with observational ports for measurements in the UV, visible, and infrared spectral regions. A cryogenic facility for cooling the particles to temperature of approx. 10-50K is being installed. The current and the planned measurements include: dust charging processes, photoelectric emissions and yields with UV irradiation, radiation pressure measurements, infrared absorption and scattering properties, and condensation processes, involving the analogs of cosmic dust grains. Selected results based on photoemissions, radiation pressure, and other laboratory measurements will be presented.

Abbas, M. M.↗