Search NASA⌕ Search

SEARCH · Search NASA

Results for “fault protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Self-Security for Grid-Interactive Smart Inverters Using Steady-State Reference Model

Smart inverters exchange information with other devices through a shared communication link, making the inverters more prone to receive harmful commands from external parties. This erroneous data can be received due to an anomaly in the system, such as a device fault, unintentional utility operator action, or a cyber-attack. In this paper, a device-level self-security strategy is implemented using reference models for a grid-interactive inverter to examine the incoming power setpoints, detect the anomalies, and protect the system accordingly. The PQ setpoints received from the utility supervisory controller are autonomously examined using the inverter’s normal and stable operating regions before engaging the setpoints to the inverter’s local controller. Grid parameters are estimated in real-time during the examination process. The efficacy of the self-security algorithm is tested using a three-phase 3-kVA SiC-MOSFET inverter and a 12-kW NHR 9410 regenerative grid emulator. The results verify that the proposed method can detect harmful PQ setpoints that can cause abnormal or unstable inverter operation.

Gursoy, Mehmetcan↗

Feedback Control Strategy for Transient Stability Application

Power systems are subjected to a wide range of disturbances during daily operations. Severe disturbances, such as a loss of a large generator, a three-phase bolted fault on a generator bus, or a loss of a transmission line, can lead to the loss of synchronism of a generator or group of generators. The ability of a power system to maintain synchronism during the few seconds after being subjected to a severe disturbance is known as transient stability. Most of the modern methods of controlling transient stability involve special protection schemes or remedial action schemes. These special protection schemes sense predetermined system conditions and take corrective actions, such as generator tripping or generation re-dispatch, in real time to maintain transient stability. Another method is the use of a real-time feedback control system to modulate the output of an actuator in response to a signal. This paper provides a fundamental evaluation of the use of feedback control strategies to improve transient stability in a power system. An optimal feedback control strategy that modulates the real power injected and absorbed by distributed energy-storage devices is proposed. Its performance is evaluated on a four-machine power system and on a 34-machine reduced-order model of the Western North American Power System. The result shows that the feedback control strategy can increase the critical fault clearing time by 60%, thereby improving the transient stability of the power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Protection of Distribution Circuits with High Penetration of Solar PV: Distance, Learning, and Estimation-Based Methods

The results of DOE Solar Energy Technologies Office project 34233 are presented. The newest version of IEEE Standard 1547 enables photovoltaic inverters to ride through voltage disturbances, improving bulk system reliability, at the expense of removing undervoltage trip as a fast method of de facto fault detection in high PV adoption scenarios. The project explored new methods of fault detection that don't rely on communication systems and could be available quickly, including distance-based schemes, focused directional relays, and two different data-driven schemes. The schemes were evaluated with fast-phasor simulation, electromagnetic transient simulation, and field data collection at partner utilities Chattanooga Electric Power Board and Dominion Energy Virginia. Accomplishments and possible paths forward are summarized.

14 SOLAR ENERGY↗

Medium-Voltage Testbed for Comparing Advanced Power Line Sensors vs. Measurement Transformers with Electrical Grid Events

Electrical utilities have relied upon potential transformers (PTs) and current transformers (CTs) for very accurate metering and to provide reliable signals for protective relays. Less expensive alternative sensing technologies offer the possibility of wider deployment, particularly in grids that employ distributed energy resources. In this work, the performance of an advanced medi-um-voltage sensor is compared with a reference PT and CT and experimentally evaluated for different power grid scenarios on an advanced outdoor power line sensor testbed at the US De-partment of Energy’s Oak Ridge National Laboratory. The sensor is based on a capacitive divider for voltage monitoring and a Rogowski coil with integrator for current monitoring. The advanced outdoor power line sensor testbed has a real-time simulator that was used to generate transient scenarios (e.g., electrical faults, capacitor bank operation, service restoration), while the analog signals were recorded by the same high resolution power meter. The behavior of analog signals, harmonic components, total harmonic distortion, and crest factors were assessed for this power line sensor compared with the reference PT/CT, because of the absence for testing standards for advanced outdoor power line sensors.

Piesciorovsky, Emilio↗

Experimental demonstration of continuous quantum error correction

The storage and processing of quantum information are susceptible to external noise, resulting in computational errors. A powerful method to suppress these effects is quantum error correction. Typically, quantum error correction is executed in discrete rounds, using entangling gates and projective measurement on ancillary qubits to complete each round of error correction. Here we use direct parity measurements to implement a continuous quantum bit-flip correction code in a resource-efficient manner, eliminating entangling gates, ancillary qubits, and their associated errors. An FPGA controller actively corrects errors as they are detected, achieving an average bit-flip detection efficiency of up to 91%. Furthermore, the protocol increases the relaxation time of the protected logical qubit by a factor of 2.7 over the relaxation times of the bare comprising qubits. Our results showcase resource-efficient stabilizer measurements in a multi-qubit architecture and demonstrate how continuous error correction codes can address challenges in realizing a fault-tolerant system.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bounded Universal Droop Control to Enable the Operation of Power Inverters Under Some Abnormal Conditions and Maintain Voltage and Frequency Within Predetermined Ranges

The universal droop control (UDC) can be applied to power inverters having an impedance angle between -pi/2 rad and pi/2 rad to achieve voltage and frequency regulation and accurate proportional power sharing without the need of knowing the type or value of impedance. However, there is an increasing need for voltage and frequency regulation within predetermined ranges even under some abnormal conditions, such as overloading, sensor faults, and large set-point changes, etc. In this paper, a bounded nonlinear dynamics is introduced into the UDC to ensure that the voltage and frequency can always stay within predetermined ranges under normal and some abnormal conditions, up to hardware limits when current protection needs to be triggered. As a result, the proposed controller can extend the operational range of power inverters in terms of voltage and frequency regulation to cover different scenarios. More importantly, the ranges for both voltage and frequency can be chosen independently from each other. Since the original structure of the UDC is kept in the proposed controller, the properties of the UDC, such as without the need of knowing the type or value of impedance, are well maintained. Furthermore, the closed-loop stability of the system is established via the Lyapunov method. Extensive simulation and experimental results are presented to validate the effectiveness of the proposed controller.

14 SOLAR ENERGY↗

Soft error-mitigating semiconductor design system and associated methods

A soft error-mitigating semiconductor design system and associated methods that tailor circuit design steps to mitigate corruption of data in storage elements (e.g., flip flops) due to Single Events Effects (SEEs). Required storage elements are automatically mapped to triplicated redundant nodes controlled by a voting element that enforces majority-voting logic for fault-free output (i.e., Triple Modular Redundancy (TMR)). Storage elements are also optimally positioned for placement in keeping with SEE-tolerant spacing constraints. Additionally, clock delay insertion (employing either a single global clock or clock triplication) in the TMR specification may introduce useful skew that protects against glitch propagation through the designed device. The resultant layout generated from the TMR configuration may relax constraints imposed on register transfer level (RTL) engineers to make rad-hard designs, as automation introduces TMR storage registers, memory element spacing, and clock delay/triplication with minimal designer input.

Miryala, Sandeep↗

Soft error-mitigating semiconductor design system and associated methods

A soft error-mitigating semiconductor design system and associated methods that tailor circuit design steps to mitigate corruption of data in storage elements (e.g., flip flops) due to Single Events Effects (SEEs). Required storage elements are automatically mapped to triplicated redundant nodes controlled by a voting element that enforces majority-voting logic for fault-free output (i.e., Triple Modular Redundancy (TMR)). Storage elements are also optimally positioned for placement in keeping with SEE-tolerant spacing constraints. Additionally, clock delay insertion (employing either a single global clock or clock triplication) in the TMR specification may introduce useful skew that protects against glitch propagation through the designed device. The resultant layout generated from the TMR configuration may relax constraints imposed on register transfer level (RTL) engineers to make rad-hard designs, as automation introduces TMR storage registers, memory element spacing, and clock delay/triplication with minimal designer input.

Miryala, Sandeep↗

Development of a Multi-Sensor Data Science System Used for Signature Development on Solvent Extraction Processes in support of safeguards- an overview

A new nuclear fuel cycle test bed is being built at Idaho National Laboratory to support the purification of special nuclear material recovered from used fuel. The test bed provides an opportunity to research process flow and the application of computational tools in solvent extraction processes. A deeper understanding of process and equipment behavior coupled with real time data collection can indicate whether a process failure is accidental or purposeful. The goal of this project is to develop a system that utilizes non-traditional measurement sources such as vibration, acoustics, current, light, flow, and temperature in conjunction with data-based, machine learning techniques that will allow for signal discovery. This multi-sensor data can support the development of safeguards by design and security by design measures for such a facility. Additionally, it can aid in early detection and identification of removed materials indicating diversion, which is essential for initiating material recovery and actor identification. This overview encompasses the current research and testing of sensors to develop a spectrum of process signatures. To be followed by planned experiments aimed to characterize said signatures and study potential feature extraction techniques to identify a fault in the system (i.e. flow diversion).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Distribution Grid Management in the Presence of Distributed Energy Resources

The global concerns over climate change, government policies, and incentives in support of distributed energy resources (DERs) are accelerating the growth of DERs in distribution networks. The growth in DER penetration levels can create various issues such as over/under voltages, reverse power flows, overloading, and protection miscoordination. State-of-the-art grid automation solutions such as advanced distribution management systems (ADMS) and distributed energy resource management systems (DERMS) can leverage the DERs to improve distribution grid operations. The ADMS offers advanced grid management functions such as Volt-VAR optimization (VVO), fault management, and outage management to the distribution operator to improve situational awareness and optimize network operations. The DERMS solutions aggregate the small-scale BTM DERs to provide grid services including demand response, voltage regulation, and situational awareness. In this presentation, distribution grid management approaches in the presence of DERs using ADMS and DERMS will be discussed.

ADMS↗

Resilience Design Patterns: A Structured Approach to Resilience at Extreme Scale (V.2.0)

Reliability is a serious concern for future extreme-scale high-performance computing (HPC) systems. Projections based on the current generation of HPC systems and technology roadmaps suggest the prevalence of very high fault rates in future systems. The errors resulting from these faults will propagate and generate various kinds of failures, which may result in outcomes ranging from result corruptions to catastrophic application crashes. Therefore, the resilience challenge for extreme-scale HPC systems requires coordination between various hardware and software technologies that are capable of handling a broad set of fault models at accelerated fault rates. Also, due to practical limits on power consumption in future HPC systems, they are likely to embrace innovative architectures, increasing the levels of hardware and software complexities. Therefore, the techniques that seek to improve resilience must navigate the complex trade-off space between resilience and the overheads to power consumption and performance. While the HPC community has developed various resilience solutions, application-level techniques as well as system-based solutions, the solution space of HPC resilience techniques remains fragmented. There are no formal methods to integrate the various HPC resilience techniques into composite solutions, nor are there methods to holistically evaluate the adequacy and efficacy of such solutions in terms of their protection coverage, and their performance & power efficiency characteristics. Additionally, few implementations of current resilience solutions are portable to newer architectures and software environments that will be deployed on future systems. We developed a new structured approach to the management of HPC resilience using the concept of resilience-based design patterns. In general, a design pattern is a repeatable solution to a commonly occurring problem. We identified the well-known solutions that are commonly used to deal with faults, errors and failures in HPC systems. In the initial design patterns specification (version 1.0), we described the various solutions, which address specific problems in the design of resilient HPC environments, in the form of patterns. Each pattern describes a problem caused by a fault, error or failure event in an HPC environment, and then describes the core of the solution of the problem in such a way that this solution may be adapted to different systems and implemented at different layers of the system stack. The catalog of these resilience design patterns provides designers with a collection of design elements. To construct complete resilience solutions using combinations of various patterns, we defined a framework that enhances HPC designers' understanding of the important constraints and the opportunities for the design patterns to be implemented and deployed at various layers of the system stack. The design framework is also useful for establishing interfaces and mechanisms to coordinate flexible fault management across hardware and software components, as well as to consider the trade-off between performance, resilience, and power consumption when constructing a solution. The resilience design patterns specification version 1.1 included more detailed explanations of the pattern solutions, the context in which the patterns are applicable, and the implications for hardware or software design. It also provided several additional examples and detailed case studies to demonstrate the use of patterns to build realistic solutions. In version 1.2 of the specification document, we have improved the pattern descriptions, including graphical representations of the pattern components. These improvements are largely based on critical comments, feedback and suggestions received from pattern experts and readers of the previous versions of the specification. The pattern classification has been modified to further clarify the relationships between pattern categories. This version of the specification also introduces a pattern language for resilience design patterns. The pattern language presents the patterns in the catalog as a network, revealing the relations among the resilience patterns. The language provides designers with the means to explore alternative techniques for handling a specific fault model that may have different efficiency and complexity characteristics. Using the pattern language also enables the design and implementation of comprehensive resilience solutions as a set of interconnected resilience patterns that can be instantiated across layers of the system stack. The overall goal of this work is to provide hardware and software designers, as well as the users and operators of HPC systems, a systematic methodology for the design and evaluation of resilience technologies in HPC systems that keep scientific applications running to a correct solution in a timely and cost-efficient manner despite frequent faults, errors, and failures of various types. Version 2.0 expands the resilience design pattern classification and catalog to include self-stabilization patterns and reliability, availability and performance models for each structural pattern.

97 MATHEMATICS AND COMPUTING↗

An RTDS-Based Testbed for Investigating the Impacts of Transmission-Level Disturbances on Solar PV Operation

The increasing penetration of renewable energy resources such as solar and wind via power electronic inverters is challenging grid dynamics, as well as grid planning, operation, and protection. Recently, the North American Electric Reliability Corporation (NERC) has reported a series of similar events of the unintended loss of solar generation in Southern California over a large geographic area following the transmission-level disturbances. These events highlight the importance of understanding the characteristics of the transmission-side disturbances propagating into the distribution systems and their impacts on the operation of inverter-based resources. In this paper, a real-time electromagnetic simulation testbed is constructed for real-time electromagnetic simulations to generate realistic transmission-level disturbances and investigate their impacts on the solar PV operation under different fault types and locations, solar penetration levels, and loading levels. Through the simulation analysis and grid strength assessment, it is found that the grid strength at points of integration (POIs) of solar PVs significantly affects the transient stability of solar generators. Particularly, undesirable transient stability events are more likely to occur at the weak POIs following the transmission-level disturbances. Moreover, undesirable transient stability events become severer when the transmission-level disturbance is closer to the weak POIs or the disturbances become more serious. Additionally, the impact of the transmission-level disturbances on the solar PVs at the weak POIs exacerbate with the increasing solar penetration levels and loading levels. Thus, it is important to study and develop new technologies for grid planning, operation, and protection in weak grid conditions to address the emerging issues of integrating the high penetration of solar PVs and other IBRs.

14 SOLAR ENERGY↗

HEX 2-piece ID Absorber: Steady and Transient Thermal FEA

Radiation fans from Insertion Devices and Bending Magnets are “trimmed” by various water-cooled absorbers located strategically downstream of those sources. Mostly, the absorber surfaces onto which power is deposited are constructed from Glidcop Al-15 (rarely OFHC copper). On the basis of Tech Note 327 a re-design for improved thermal performance has evolved to a two-piece ID Absorber configuration; one between dipole chamber and quadrupole, another after the sextupole, each with reduced incident angle. The ring’s Active Interlock (AI) system protects against overheating by disabling mis-steered beam within an allotted time. SRP (Synchrotron Radiation Protection) protocol has a limiting maximum allowable temperature of 100*C at any point when subject to mis-steered beam for a fixed period before AI activation. After 0.2 msec, radiation exceeding +/- 0.5mm offset and +/- 0.25 mrad angular error from the HEX SCW will trip in fault. AI specification allows 1.0 msec to fully dump the electron beam.

36 MATERIALS SCIENCE↗

A Universal Refrigerant Charge Fault Detection and Diagnostics Method Based on Pump Down Operation

The performance of the heat pump system varies greatly depending on the refrigerant charge amount. Improving the refrigerant charge fault detection and diagnostics (FDD) method of vapor compression systems have the potential for increasing energy efficiency and reducing service cost. Previous studies to predict refrigerant charge amount are mostly empirical methods which require significant amount of experimental data for high accuracy. The primary goal of this research is to develop a universal charge fault detection method which requires only a few experimental data with high prediction accuracy.Currently, pump down operations are typical practices by HVAC technicians when they need to open the refrigerant circuit to make a repairment. In addition, compressors have a built-in low-pressure cut-off protection function, and the compressor performance maps are commonly available from manufacturers. The proposed method innovatively utilizes the typical pump down operation, the compressor low-pressure cut-off protection, and the compressor performance map. It does not require any geometry information of heat exchangers, refrigerant lines, or charge buffers.The new charge prediction method is firstly formulated through theoretical analysis, then verified and calibrated by a quasi-steady-state simulation of the pump down process for a residential heat pump system. The quasi steady-state simulation uses an HVAC system simulation framework driven by DOE/ORNL Heat Pump Design Model (HPDM). Preliminary experiment validations with heat pump refrigerant leakage tests demonstrate the deviation of the proposed charge prediction method compared with measurement is within 8%. This technology makes refrigerant charge amount available at the technician’s fingertips and leads to shorter maintenance time and fewer site visits.

Li, Zhenning↗

Neutron spectral measurements at the BNL NSLS-II synchrotron facility

During the first week of August 2022, Tim Gildea of Los Alamos National Laboratory’s (LANL) RP-SVS group performed a series of neutron spectral measurements at the National Synchrotron Light Source II (NSLS-II) 3GeV facility located at Brookhaven National Lab (BNL)1 . These measurements were conducted under Memorandum Purchase Order (MPO) 413911 with the objective of gaining an accurate understanding of the photoneutron fields generated under normal and selected fault conditions. The spectral data collected during the course of the study was analyzed at LANL and the results form the basis of this report.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reconfigurable Framework for Resilient Semantic Segmentation for Space Applications

Deep learning (DL) presents new opportunities for enabling spacecraft autonomy, onboard analysis, and intelligent applications for space missions. However, DL applications are computationally intensive and often infeasible to deploy on radiation-hardened (rad-hard) processors, which traditionally harness a fraction of the computational capability of their commercial-off-the-shelf counterparts. Commercial FPGAs and system-on-chips present numerous architectural advantages and provide the computation capabilities to enable onboard DL applications; however, these devices are highly susceptible to radiation-induced single-event effects (SEEs) that can degrade the dependability of DL applications. In this article, we propose Reconfigurable ConvNet (RECON), a reconfigurable acceleration framework for dependable, high-performance semantic segmentation for space applications. In RECON, we propose both selective and adaptive approaches to enable efficient SEE mitigation. In our selective approach, control-flow parts are selectively protected by triple-modular redundancy to minimize SEE-induced hangs, and in our adaptive approach, partial reconfiguration is used to adapt the mitigation of dataflow parts in response to a dynamic radiation environment. Combined, both approaches enable RECON to maximize system performability subject to mission availability constraints. We perform fault injection and neutron irradiation to observe the susceptibility of RECON and use dependability modeling to evaluate RECON in various orbital case studies to demonstrate a 1.5–3.0× performability improvement in both performance and energy efficiency compared to static approaches.

97 MATHEMATICS AND COMPUTING↗

FIDVR Capability of Hybrid Grid-Forming PV Power Plants During Feeder Restoration

Grid-forming inverters must optimally transfer power from dc-coupled photovoltaic arrays and batteries into an ac grid. Further, they must be able to restore single-phase induction motors (SPIMs) and withstand fault-induced delayed voltage-recovery (FIDVR) events. These resilience and reliability challenges are addressed here by: (i) engineering a controller to optimally operate dc-coupled hybrid resources; (ii) modeling residential air-conditioning compressors for restoration/FIDVR studies; and (iii) analyzing SPIM thermal-relay performance under limited inverter currents and designing an electronic protection for stalled SPIMs. Furthermore, these contributions are demonstrated via electromagnetic-transient simulations and can be helpful to understand recommendations by the North American Electric Reliability Corporation.

14 SOLAR ENERGY↗