Search NASA⌕ Search

SEARCH · Search NASA

Results for “filter methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

SU-D-17A-03: 5D Respiratory Motion Model Based Iterative Reconstruction Method for 4D Cone-Beam CT

Purpose: The purpose of this work is to develop a new iterative reconstruction method for 4D cone-beam CT (CBCT) based on a published time-independent 5D respiratory motion model. The proposed method will offer a single high-resolution image at a user-selected breathing phase and the 5D motion model parameters, which could be used to generate the breathing pattern during the CT acquisition. Methods: 5D respiratory motion model was proposed for accurately modeling the motion of lung and lung tumor tissues. 4D images are then parameterized by a reference image, measured breathing amplitude, breathing rate, two time-independent vector fields that describe the 5D model parameters, and a scalar field that describes the change in HU as a function of breathing amplitude. In contrast with the traditional method of reconstructing multiple temporal image phases to reduce respiratory artifact, 5D model based method simplify the problem into the reconstruction of a single reference image and the 5D motion model parameters. The reconstruction formulation of the reference image and scalar and vector fields is a nonlinear least-square optimization problem that consists of solving the reference image and fields alternately, in which the reference image is regularized with the total variation sparsity transform and the vector fields are solved through linearizations regularized by the H1 norm. 2D lung simulations were performed in this proof-of-concept study. Results: The breathing amplitude, its rate, and the corresponding scalar and vector fields were generated from a patient case. Compared with filtered backprojection method and sparsity regularized iterative method for the phase-by-phase reconstruction, the proposed 5D motion model based method yielded improved image quality. Conclusion: Based on 5D respiratory motion model, we have developed a new iterative reconstruction method for 4D CBCT that has the potential for improving image quality while providing needed on-table motion information.

60 APPLIED LIFE SCIENCES↗

Constructing Regulatory Networks to Compare Axenic and Interspecies Microbial Gene Transcription

In this preliminary study, we constructed gene regulatory networks (GRNs) from transcriptional expression data of axenic and interspecies microbial cultures with the goal of predicting how cocultivation affected greenhouse gas respiration by these species. The specific strains of Methylotuvimicrobium alkaliphilum 20Z, a methylotroph, and Cyanobacterium stanieri HL-69, a phototroph, were chosen for their viability in industrial bioprocessing. We ranked directed interactions between gene pairs based on the ability of the input gene to predict the expression of a target gene relative to their transcriptomes. While we were able to identify topological differences between conditions, our initial findings require validation through experimental analysis and further modeling. We aimed to develop a systematic thresholding approach to optimize the accuracy of our networks. We filtered out trial networks separately from top gene interactions of the scored rankings. Parameters of unfiltered and filtered networks were used to test and develop thresholding approaches. Knee point detection of edge weight distributions was explored as an approach for separating significant interactions from insignificant interactions in unfiltered networks. While knee detection failed to produce analogous networks for broad cross-condition comparisons, the results informed us about the proportions of significant edges present in unfiltered networks. We also calculated the average mean degree for nodes in a selection of trial networks to find a thresholding value characteristic to all groups. While we did not reach a definitive conclusion, we gained insight into the coregulatory structures of our groups and made critical evaluations of systematic methods for filtering networks. We recommend an iterative process for the inference of GRNs, where the most significant results from preliminary explorations are used to improve the efficiency with which regulatory motifs are chosen for experimental characterization. Experimental results can then inform the framework of adjusted models to improve broad interpretations of GRNs.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-T-670: Radiotherapy Vault Shielding Evaluation Method for a Flattening Filter-Free (FFF) Linac-Practical Considerations and Recommendations

Purpose: To date, there isn’t formal approach for flattening filter-free (FFF) linac vault shielding evaluation, thus, we propose an extension to NCRP#151 to accommodate the recent large number of FFF linac installations.Methods and Materials: We extended the approach in NCRP#151 to design two Truebeam vaults in our new cancer center for hypofractionated treatments. Monte Carlo calculations have characterized primary, scattered, leakage and neutron radiations from FFF-modes. These calculations have shown that: a) FFF primary beam is softer on the central-axis compared to flattening filtered (FF), b) the lateral dose profile is peaked on the central axis and less integral target current is required to generate the same tumor dose with the FF beam. Thus, the TVLs for FFF mode are smaller than those of the FF mode and the scatter functions of the FF mode (NCRP#151) may not be appropriate for FFF-mode, c) the neutron source strength and fluence for 18X-FFF is smaller than 18X-FF, but it is not of a concern here, no 18X-FFF-mode is available on the linac under investigation. Results: These barrier thickness are smaller (12% reduction on the average) than those computed for conventional FF mode with same realistic primary workload since, the primary TVLs used here are smaller and the WL is smaller than the conventional (almost half reduced), keeping the TADR in tolerance. Conclusions: A comprehensive method for shielding barrier calculations based on dedicated data for FFF-mode linacs is highly desired. Meanwhile, we provide an extension to NCRP#151 to accommodate the shielding design of such installations. It is also shown that if a vault is already designed for IMRT/VMAT and SABR hypofractionated treatments with FFF-mode linac, the vault can also be used for a FFF mode linac replacement, leaving some leeway for slightly higher workload on the FFF linac.

61 RADIATION PROTECTION AND DOSIMETRY↗

Sparse measurement medical CT reconstruction using multi-fused block matching denoising priors

A major challenge for medical X-ray CT imaging is reducing the number of X-ray projections to lower radiation dosage and reduce scan times without compromising image quality. However these under-determined inverse imaging problems rely on the formulation of an expressive prior model to constrain the solution space while remaining computationally tractable. Traditional analytical reconstruction methods like Filtered Back Projection (FBP) often fail with sparse measurements, producing artifacts due to their reliance on the Shannon-Nyquist Sampling Theorem. Consensus Equilibrium, which is a generalization of Plug and Play, is a recent advancement in Model-Based Iterative Reconstruction (MBIR), has facilitated the use of multiple denoisers are prior models in an optimization free framework to capture complex, non-linear prior information. However, 3D prior modelling in a Plug and Play approach for volumetric image reconstruction requires long processing time due to high computing requirement. Instead of directly using a 3D prior, this work proposes a BM3D Multi Slice Fusion (BM3D-MSF) prior that uses multiple 2D image denoisers fused to act as a fully 3D prior model in Plug and Play reconstruction approach. Our approach does not require training and are thus able to circumvent ethical issues related with patient training data and are readily deployable in varying noise and measurement sparsity levels. In addition, reconstruction with the BM3D-MSF prior achieves similar reconstruction image quality as fully 3D image priors, but with significantly reduced computational complexity. We test our method on clinical CT data and demonstrate that our approach improves reconstructed image quality.

Hossain, Maliha [ORNL]↗

MASS AND ENERGY OF ERUPTING SOLAR PLASMA OBSERVED WITH THE X-RAY TELESCOPE ON HINODE

We investigate seven eruptive plasma observations by Hinode/XRT. Their corresponding EUV and/or white light coronal mass ejection features are visible in some events. Five events are observed in several passbands in X-rays, which allows for the determination of the eruptive plasma temperature using a filter ratio method. We find that the isothermal temperatures vary from 1.6 to 10 MK. These temperatures are an average weighted toward higher temperature plasma. We determine the mass constraints of eruptive plasmas by assuming simplified geometrical structures of the plasma with isothermal plasma temperatures. This method provides an upper limit to the masses of the observed eruptive plasmas in X-ray passbands since any clumping causes the overestimation of the mass. For the other two events, we assume the temperatures are at the maximum temperature of the X-ray Telescope (XRT) temperature response function, which gives a lower limit of the masses. We find that the masses in XRT, ∼3 × 10{sup 13}-5 × 10{sup 14} g, are smaller in their upper limit than the total masses obtained by LASCO, ∼1 × 10{sup 15} g. In addition, we estimate the radiative loss, thermal conduction, thermal, and kinetic energies of the eruptive plasma in X-rays. For four events, we find that the thermal conduction timescales are much shorter than the duration of eruption. This result implies that additional heating during the eruption may be required to explain the plasma observations in X-rays for the four events.

79 ASTRONOMY AND ASTROPHYSICS↗

High-Resolution Spatio-Temporal Estimation of Net Ecosystem Exchange in Ice-Wedge Polygon Tundra Using In Situ Sensors and Remote Sensing Data

Land-atmosphere carbon exchange is known to be extremely heterogeneous in arctic ice-wedge polygonal tundra regions. In this study, a Kalman filter-based method was developed to estimate the spatio-temporal dynamics of daytime average net ecosystem exchange (NEEday) at 0.5-m resolution over a 550 m by 700 m study site. We integrated multi-scale, multi-type datasets, including normalized difference vegetation indices (NDVIs) obtained from a novel automated mobile sensor system (or tram system) and a greenness index map obtained from airborne imagery. We took advantage of the significant correlations between NDVI and NEEday identified based on flux chamber measurements. The weighted average of the estimated NEEday within the flux-tower footprint agreed with the flux tower data in term of its seasonal dynamics. We then evaluated the spatial variability of the growing season average NEEday, as a function of polygon geomorphic classes; i.e., the combination of polygon types—which are known to present different degradation stages associated with permafrost thaw—and microtopographic features (i.e., troughs, centers and rims). Our study suggests the importance of considering microtopographic features and their spatial coverage in computing spatially aggregated carbon exchange.

54 ENVIRONMENTAL SCIENCES↗

Neutron flux from a 14-MeV neutron generator with tungsten filter for research in NDA methods for nuclear safeguards and security

The Joint Research Centre has taken into operation a new experimental device designed for research in the fields of nuclear safeguards and security applications. The research projects currently undertaken include detection of shielded contraband materials, detection of fissile materials, and mass determination of small fissile materials in shielded containers. The device, called the Pulsed Neutron Interrogation Test Assembly (PUNITA), incorporates a pulsed 14-MeV (D-T) neutron generator and a large graphite mantle surrounding the sample cavity. By pulsing the neutron generator with a frequency in the range of 10 to 150 Hz, a sample may be interrogated first by fast neutrons and a few hundred micro-seconds later by a pure thermal neutron flux. The permanent detection systems incorporated in PUNITA include {sup 3}He neutrons detectors, HPGe gamma detectors, and lanthanum bromide scintillation detectors.We have studied the effects of placing a tungsten liner around the neutron generator target. The 14-MeV neutrons induce (n, 2n) and (n, 3n) reactions. In addition the mean neutron energy emitted from generator/tungsten assembly is reduced to about 1 MeV. Both of these effects increase the thermal neutron flux in the sample cavity. The paper describes the observed advantages of the tungsten liner with respect to increase in thermal flux, and better shielding capabilities of the nearby gamma and neutron detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-133: Autosegmentation of Linac CBCT: Improved Accuracy Via Penalized Likelihood Reconstruction

Purpose: To improve the quality of kV X-ray cone beam CT (CBCT) for use in radiotherapy delivery assessment and re-planning by using penalized likelihood (PL) iterative reconstruction and auto-segmentation accuracy of the resulting CBCTs as an image quality metric. Methods: Present filtered backprojection (FBP) CBCT reconstructions can be improved upon by PL reconstruction with image formation models and appropriate regularization constraints. We use two constraints: 1) image smoothing via an edge preserving filter, and 2) a constraint minimizing the differences between the reconstruction and a registered prior image. Reconstructions of prostate therapy CBCTs were computed with constraint 1 alone and with both constraints. The prior images were planning CTs(pCT) deformable-registered to the FBP reconstructions. Anatomy segmentations were done using atlas-based auto-segmentation (Elekta ADMIRE). Results: We observed small but consistent improvements in the Dice similarity coefficients of PL reconstructions over the FBP results, and additional small improvements with the added prior image constraint. For a CBCT with anatomy very similar in appearance to the pCT, we observed these changes in the Dice metric: +2.9% (prostate), +8.6% (rectum), −1.9% (bladder). For a second CBCT with a very different rectum configuration, we observed +0.8% (prostate), +8.9% (rectum), −1.2% (bladder). For a third case with significant lateral truncation of the field of view, we observed: +0.8% (prostate), +8.9% (rectum), −1.2% (bladder). Adding the prior image constraint raised Dice measures by about 1%. Conclusion: Efficient and practical adaptive radiotherapy requires accurate deformable registration and accurate anatomy delineation. We show here small and consistent patterns of improved contour accuracy using PL iterative reconstruction compared with FBP reconstruction. However, the modest extent of these results and the pattern of differences across CBCT cases suggest that significant further development will be required to make CBCT useful to adaptive radiotherapy.

60 APPLIED LIFE SCIENCES↗

Crosstalk elimination in the detection of dual-beam optical tweezers by spatial filtering

In dual-beam optical tweezers, the accuracy of position and force measurements is often compromised by crosstalk between the two detected signals, this crosstalk leading to systematic and significant errors on the measured forces and distances. This is true both for dual-beam optical traps where the splitting of the two traps is done by polarization optics and for dual optical traps constructed by other methods, e.g., holographic tweezers. If the two traps are orthogonally polarized, most often crosstalk is minimized by inserting polarization optics in front of the detector; however, this method is not perfect because of the de-polarization of the trapping beam introduced by the required high numerical aperture optics. Here we present a simple and easy-to-implement method to efficiently eliminate crosstalk. The method is based on spatial filtering by simply inserting a pinhole at the correct position and is highly compatible with standard back focal plane photodiode based detection of position and force. Our spatial filtering method reduces crosstalk up to five times better than polarization filtering alone. The effectiveness is dependent on pinhole size and distance between the traps and is here quantified experimentally and reproduced by theoretical modeling. The method here proposed will improve the accuracy of force-distance measurements, e.g., of single molecules, performed by dual-beam optical traps and hence give much more scientific value for the experimental efforts.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced trust region optimization strategies for glass box / black box models

We present an improved trust region filter (TRF) method for optimization of combined glass box/black box systems. Glass box systems refer to models that are easily expressed in an algebraic modeling language, providing cheap and accurate derivative information. By contrast, black box systems may be computationally expensive and derivatives are unavailable. The TRF method, as first introduced in our previous work (Eason and Biegler, AIChE J . 2016; 62:3124–3136), is able to handle hybrid systems containing both glass and black box components, which can frequently arise in chemical engineering, for example, when a multiphase reactor model is included in a flow sheet optimization problem. We discuss several recent modifications in the algorithm such as the sampling region, which maintains the algorithm's global convergence properties without requiring the trust region to shrink to zero in the limit. To benchmark the development of this optimization method, a test set of problems is generated based on modified problems from the CUTEr and COPS sets. The modified algorithm demonstrates improved performance using the test problem set. Finally, the algorithm is implemented within the Pyomo environment and demonstrated on a rigorous process optimization case study for carbon capture. © 2018 American Institute of Chemical Engineers AIChE J , 64: 3934–3943, 2018

Eason, John P.↗

FREDA: A Web Application for the Processing, Analysis, and Visualization of Fourier‐Transform Mass Spectrometry Data

The high-resolution measurement capability of Fourier-transform mass spectrometry (FT-MS) has made it a necessity for exploring the molecular composition of complex organic mixtures, like soil, plant, aquatic, and petroleum samples. This demand has driven a need for informatics tools to explore and analyze FT-MS data in a robust and reproducible manner. FREDA is an interactive web application developed to enable spectrometrists to format, process, and explore their FT-MS data without the need for statistical programming expertise. FREDA was built to explore outputs from a molecular identification tool, like CoreMS, and provide a suite of methods to filter data, compute chemical properties of peaks, statistically compare samples and groups of samples, conduct exploratory data analysis, and download the results with a report detailing all steps conducted. To demonstrate the utility of FREDA, an example analysis was conducted using FT-MS data from a soil microbiology study of samples collected in two different soil depths at the Sphagnum bog forest north of Grand Rapids, Minnesota. Differences between the two depths are observed using Kendrick, Gibbs free energy, and van Krevelen plots. G-tests are used to quantify a significant difference between the groups. All analyses and plotting are conducted using only the FREDA application. FREDA is an open-source and readily available web application that allows users to explore and make statistically valid conclusions about their FT-MS data. The application is available online (https://map.emsl.pnnl.gov/app/freda) with a tutorial web series (https://youtu.be/k5HLE2kNSBY?si=yB6sGoyvzxrFf5MP) and freely accessible code on Github (https://github.com/EMSL-Computing/FREDA).

47 OTHER INSTRUMENTATION↗

A Modified Johnson–Cook Model for Flow Behavior of Alloy 800H at Intermediate Strain Rates and High Temperatures

A modified Johnson–Cook model for the flow behavior of alloy 800H at intermediate strain rates and high temperatures is presented. The modification is based on a study of the relation between strain hardening and both strain rate and softening parameters. The predicted stresses obtained using the modified model are compared to those obtained using the original Johnson–Cook model. The parameters constitute the two models are determined using the inverse method, Kalman filter. The results show that the modified model fits the experimental data very well for different combinations of strain rates and temperatures, with a mean value of R-squared regression of 0.90 for the modified model and 0.74 for the original Johnson–Cook model.

36 MATERIALS SCIENCE↗

Isothermal evaporation of a-pinene ozonolysis SOA: volatility, phase state, and oligomeric composition

We present measurements of the isothermal evaporation of a-pinene ozonolysis secondary organic aerosol (SOA). Using a novel, filter-based method, we replicate previous findings of the volume fraction remaining, presented here as carbon number weighted signal fraction remaining (SFR), as a function of evaporation time. We apply two detailed physical models to interpret the evaporative behavior of both the bulk SOA and individual components. Both models find that a combination of effectively non-volatile products, together with reversible oligomers (or otherwise reactive monomers) having a decomposition lifetime of 9 to 28 hours, best explains the evolution of composition and volatility as particles age in the absence of both organic vapors and oxidants, even under an assumption of relatively viscous (soft wax-like) particles. We find that the residence time in the SOA formation chamber, and time spent undergoing isothermal evaporation, both indicative of the physical age of the aerosol, are the most important experimental parameter determining the evaporation rate. The evolution of volatility observed in these experiments is compared to field measurements in a boreal forest site. The ambient monoterpene-dominated SOA volatility is only reproduced in the laboratory after 24 hours of extended aging in a dilute, dark, oxidant-free environment.

D'Ambro, Emma↗

A real-time algorithm for the harmonic estimation and frequency tracking of dominant components in fusion plasma magnetic diagnostics

The real-time tracking of instantaneous quantities such as frequency, amplitude, and phase of components immerse in noisy signals has been a common problem in many scientific and engineering fields such as power systems and delivery, telecommunications, and acoustics for the past decades. In magnetically confined fusion research, extracting this sort of information from magnetic signals can be of valuable assistance in, for instance, feedback control of detrimental magnetohydrodynamic modes and disruption avoidance mechanisms by monitoring instability growth or anticipating mode-locking events. This work is focused on nonlinear Kalman filter based methods for tackling this problem. Similar methods have already proven their merits and have been successfully employed in this scientific domain in applications such as amplitude demodulation for the motional Stark effect diagnostic. In the course of this work, three approaches are described, compared, and discussed using magnetic signals from the Joint European Torus tokamak plasma discharges for benchmarking purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microwave frequency sweep interferometer for plasma density measurements in ECR ion sources: Design and preliminary results

The Electron Cyclotron Resonance Ion Sources (ECRISs) development is strictly related to the availability of new diagnostic tools, as the existing ones are not adequate to such compact machines and to their plasma characteristics. Microwave interferometry is a non-invasive method for plasma diagnostics and represents the best candidate for plasma density measurement in hostile environment. Interferometry in ECRISs is a challenging task mainly due to their compact size. The typical density of ECR plasmas is in the range 10{sup 11}–10{sup 13} cm{sup −3} and it needs a probing beam wavelength of the order of few centimetres, comparable to the chamber radius. The paper describes the design of a microwave interferometer developed at the LNS-INFN laboratories based on the so-called “frequency sweep” method to filter out the multipath contribution in the detected signals. The measurement technique and the preliminary results (calibration) obtained during the experimental tests will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An efficient reconstruction algorithm for differential phase-contrast tomographic images from a limited number of views

The main focus of this paper is reconstruction of tomographic phase-contrast image from a set of projections. We propose an efficient reconstruction algorithm for differential phase-contrast computed tomography that can considerably reduce the number of projections required for reconstruction. The key result underlying this research is a projection theorem that states that the second derivative of the projection set is linearly related to the Laplacian of the tomographic image. The proposed algorithm first reconstructs the Laplacian image of the phase-shift distribution from the second-derivative of the projections using total variation regularization. The second step is to obtain the phase-shift distribution by solving a Poisson equation whose source is the Laplacian image previously reconstructed under the Dirichlet condition. We demonstrate the efficacy of this algorithm using both synthetically generated simulation data and projection data acquired experimentally at a synchrotron. The experimental phase data were acquired from a human coronary artery specimen using dark-field-imaging optics pioneered by our group. Our results demonstrate that the proposed algorithm can reduce the number of projections to approximately 33% as compared with the conventional filtered backprojection method, without any detrimental effect on the image quality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗