Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Three-Dimensional Stereoscopic Tracking Velocimetry and Experimental/Numerical Comparison of Directional Solidification

Measurement of three-dimensional (3-D) three-component velocity fields is of great importance in both ground and space experiments for understanding materials processing and fluid physics. The experiments in these fields most likely inhibit the application of conventional planar probes for observing 3-D phenomena. Here, we present the investigation results of stereoscopic tracking velocimetry (STV) for measuring 3-D velocity fields, which include diagnostic technology development, experimental velocity measurement, and comparison with analytical and numerical computation. STV is advantageous in system simplicity for building compact hardware and in software efficiency for continual near-real-time monitoring. It has great freedom in illuminating and observing volumetric fields from arbitrary directions. STV is based on stereoscopic observation of particles-Seeded in a flow by CCD sensors. In the approach, part of the individual particle images that provide data points is likely to be lost or cause errors when their images overlap and crisscross each other especially under a high particle density. In order to maximize the valid recovery of data points, neural networks are implemented for these two important processes. For the step of particle overlap decomposition, the back propagation neural network is utilized because of its ability in pattern recognition with pertinent particle image feature parameters. For the step of particle tracking, the Hopfield neural network is employed to find appropriate particle tracks based on global optimization. Our investigation indicates that the neural networks are very efficient and useful for stereoscopically tracking particles. As an initial assessment of the diagnostic technology performance, laminar water jets with and without pulsation are measured. The jet tip velocity profiles are in good agreement with analytical predictions. Finally, for testing in material processing applications, a simple directional solidification apparatus is built for experimenting with a metal analog of succinonitrile. Its 3-D velocity field at the liquid phase is then measured to be compared with those from numerical computation. Our theoretical, numerical, and experimental investigations have proven STV to be a viable candidate for reliably measuring 3-D flow velocities. With current activities are focused on further improving the processing efficiency, overall accuracy, and automation, the eventual efforts of broad experimental applications and concurrent numerical modeling validation will be vital to many areas in fluid flow and materials processing.

Lee, David↗

Multivariate environmental and trait-based controls of transpiration in the Central Amazon Rainforest

Tropical forest tree mortality is increasing due to more severe droughts, yet our understanding of how tree traits and life strategies are linked to drought stress has been limited by measurement scarcity. The BIONTE (BIOmass and NuTrient Experiment) near Manaus, Brazil hosts one of the world’s largest sap flow installations, with sensors in 90 canopy trees across a wood density gradient monitored since June 2022. The 2023 El Niño drought provided a unique opportunity to evaluate how water availability impacts tree transpiration. An interpretable machine learning framework was used to study the complex interactions between transpiration and multiple environmental variables such as soil water availability and vapor pressure deficit (VPD), and how these interactions vary with wood density and individual trees. We found varying responses of transpiration from different trees during the El Niño drought. Transpiration generally increased with temperature, with stronger effects in wetter areas and in trees with low to medium wood density. However, this response was modulated by stomatal sensitivity to VPD, which constrained transpiration under high atmospheric demand, particularly in intermediate-moisture area. The inflection in transpiration rate at high temperatures (>32°C) underscores the role of stomatal and hydraulic regulation in limiting water loss and protecting trees from excessive evaporative demand. Analysis of soil water contribution to transpiration revealed unimodal patterns in wetter area, with peak contributions near 0.45 cm 3 cm -3 of surface soil water and declining or flat responses beyond that threshold, suggesting a shift from water- to energy-limited transpiration. In contrast, drier areas exhibited limited transpiration sensitivity to soil water conditions and minimal trait-based variation in VPD responses, indicating supply-limited conditions. Despite higher wood density trees being generally more resilient, this study shows diverse tree drought resilience, prompting further investigation into the specific traits and dynamics between environmental variables in regulating transpiration and other physiological processes in trees.

Drought↗

Efficient and Flexible Sensitivity Matrix Computation for Adaptive Electrical Capacitance Volume Tomography

Electrical capacitance tomography is a widely used sensor modality for flow imaging in many industrial settings. Adaptive Electrical Capacitance Volume Tomography (AECVT) extends the capabilities of traditional ECT by enabling direct volumetric imaging and an improved resolution. Construction of the sensitivity matrix is a necessary step to obtain flow images. This step requires computation of the electric field inside the sensing domain, which is done via a typical field solver such as the finite element method. In this work, we present an efficient and flexible method to construct the sensitivity matrix for Adaptive Electrical Capacitance Volume Tomography (AECVT) based on individual electrode segment excitations and their judicious combination to form desired matrix elements. We illustrate how the proposed method yields the same sensitivity matrix as the traditional method but at a much lower computational cost. Once all segment contributions are obtained, we also indicate how the proposed method, unlike the traditional approach, can generate the sensitivity matrix on demand for an arbitrary combination of synthetic electrodes and obviating the need for any additional field computations. Finally, we present image reconstruction results for two different experimental scenarios where the mutual capacitance data and the corresponding sensitivity vectors are obtained through the proposed measurement combination scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigating the Electromechanical Sensitivity of Carbon-Nanotube-Coated Microfibers

The piezoresistance of carbon nanotube (CNT)-coated microfibers is examined using diametric compression. Diverse CNT forest morphologies were studied by changing the CNT length, diameter, and areal density via synthesis time and fiber surface treatment prior to CNT synthesis. Large-diameter (30–60 nm) and relatively low-density CNTs were synthesized on as-received glass fibers. Small-diameter (5–30 nm) and-high density CNTs were synthesized on glass fibers coated with 10 nm of alumina. The CNT length was controlled by adjusting synthesis time. Electromechanical compression was performed by measuring the electrical resistance in the axial direction during diametric compression. Gauge factors exceeding three were measured for small-diameter (<25 μm) coated fibers, corresponding to as much as 35% resistance change per micrometer of compression. The gauge factor for high-density, small-diameter CNT forests was generally greater than those for low-density, large-diameter forests. A finite element simulation shows that the piezoresistive response originates from both the contact resistance and intrinsic resistance of the forest itself. The change in contact and intrinsic resistance are balanced for relatively short CNT forests, while the response is dominated by CNT electrode contact resistance for taller CNT forests. These results are expected to guide the design of piezoresistive flow and tactile sensors.

36 MATERIALS SCIENCE↗

Thermal coupling apparatus for electroexplosive devices

This paper describes the equipment for nondestructive testing of electroexplosive devices using a thermal coupling technique. The technique utilizes a self-balancing bridge to apply a nominal amount of power to the bridge wire of the device. The bridge wire behaving as a thermal sensor detects heat flow into the device when heat is preferentially directed down the center of the explosive column toward the bridge wire. Thermal equilibrium is upset and the change in power from the self-balancing bridge is measured directly in watts. Faults such as omissions, incorrect materials, contamination, and so on, can be detected by observing the rate of heat flow to the bridge wire. The response is indicative of the thermal resistance and diffusivity of the system. The paper also presents data on electroexplosive devices loaded with inert and explosive materials.

Menichelli, V. J.↗

SEASAT economic assessment. Volume 10: The SATIL 2 program (a program for the evaluation of the costs of an operational SEASAT system as a function of operational requirements and reliability

The SATIL 2 computer program was developed to assist with the programmatic evaluation of alternative approaches to establishing and maintaining a specified mix of operational sensors on spacecraft in an operational SEASAT system. The program computes the probability distributions of events (i.e., number of launch attempts, number of spacecraft purchased, etc.), annual recurring cost, and present value of recurring cost. This is accomplished for the specific task of placing a desired mix of sensors in orbit in an optimal fashion in order to satisfy a specified sensor demand function. Flow charts are shown, and printouts of the programs are given.

Source record↗

Development of a fluidic rudder

Wind tunnel tests were performed to examine the concept of aircraft controls without moving parts, and aircraft stabilization by means of scoop-fed slots. Results of wind tunnel tests, in the framework of a NASA program, to determine the force-control characteristics of a symmetrical airfoil with scoop-fed slots are discussed. Further tests showed that a fluidic amplifier could be built into the airfoil and operate with ram air. A fluidic rudder was then developed, consisting of cascaded fluidic amplifiers necessary to couple low-level fluidic sensors with slot flow control of the aerodynamic force on the vertical tail.

Belsterling, C. A.↗

Passive microwave data for snow and ice research - Planned products from the DMSP SSM/I system

Recommendations which have been made for processing and distributing passive microwave data for snow and ice research obtained with the Defense Meteorological Satellite Program (DMSP) Special Sensor Microwave Imager (SSM/I) are discussed. The general objectives for SSM/I data are reviewed, and the sensor and data flow are described. The SSM/I sea ice products are discussed, and algorithm/product validation is addressed. Proposed services and implementation after SSM/I launch are summarized.

Weawer, Ronald↗

Microwave Treatment for Cardiac Arrhythmias

Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about six gigahertz. A computer simulation provides initial screening capabilities for an antenna such as antenna, frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 Gigahertz and 12 Gigahertz is applied to monopole microwave radiator having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may be used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

Arndt, G. Dickey↗

Transcatheter Antenna For Microwave Treatment

Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about six gigahertz. A computer simulation provides initial screening capabilities for an antenna such as antenna, frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 Gigahertz and 12 Gigahertz is applied to monopole microwave radiation having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may he used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

Arndt, G. Dickey↗

In Vivo Simulator for Microwave Treatment

Method and apparatus are provided for propagating microwave energy into heart tissues to produce a desired temperature profile therein at tissue depths sufficient for thermally ablating arrhythmogenic cardiac tissue to treat ventricular tachycardia and other arrhythmias while preventing excessive heating of surrounding tissues, organs, and blood. A wide bandwidth double-disk antenna is effective for this purpose over a bandwidth of about 6 GHz. A computer simulation provides initial screening capabilities for an antenna such as antenna. frequency, power level, and power application duration. The simulation also allows optimization of techniques for specific patients or conditions. In operation, microwave energy between about 1 GHz and 12 GHz is applied to monopole microwave radiator having a surface wave limiter. A test setup provides physical testing of microwave radiators to determine the temperature profile created in actual heart tissue or ersatz heart tissue. Saline solution pumped over the heart tissue with a peristaltic pump simulates blood flow. Optical temperature sensors disposed at various tissue depths within the heart tissue detect the temperature profile without creating any electromagnetic interference. The method may be used to produce a desired temperature profile in other body tissues reachable by catheter such as tumors and the like.

Arndt, G. Dickey↗

Medusa Sea Floor Monitoring System

The objective of the research described in this poster presentation is to develop technologies to enable fundamental research into understanding the potential for and limits to chemolithoautotrophic life. The Medusa Isosampler (isobaric sampler), for sampling fluids eminating from deep sea hydrothermal vents and cold seep sites analogous to extraterrestrial environments, is described by the presentation. The following instruments are integrated with the isosampler, and also described: in situ flow-through chemical sensor, intrinsic fluorescent-based microbial detector, isotope ratio spectral detector.

Flynn, Michael↗

Correction for Self-Heating When Using Thermometers as Heaters in Precision Control Applications

In precision control applications, thermometers have temperature-dependent electrical resistance with germanium or other semiconductor material thermistors, diodes, metal film and wire, or carbon film resistors. Because resistance readout requires excitation current flowing through the sensor, there is always ohmic heating that leads to a temperature difference between the sensing element and the monitored object. In this work, a thermistor can be operated as a thermometer and a heater, simultaneously, by continuously measuring the excitation current and the corresponding voltage. This work involves a method of temperature readout where the temperature offset due to self-heating is subtracted exactly.

Ressler, Michael E.↗

Incineration system and process

An incineration system includes an inlet channel supplying an inlet stream comprising a waste gas containing at least one volatile organic compound, a waste gas sensor measuring at least one property of the waste gas, an oxidizing gas supply controllably providing oxidizing gas to the inlet channel, an incinerator receiving the inlet stream from the inlet channel, an ignitor initiating combustion of the inlet stream in the reaction zone of the incinerator, and a controller receiving data from the waste gas sensor and controlling flow of oxidizing gas from the oxidizing gas supply into the inlet channel. The spiral heat exchanger defines a reaction zone, an incoming path from the inlet channels to the reaction zone, and an outgoing path from the reaction zone to an exhaust channel. The incoming path and the outgoing path extend in alternating concentric spirals with the incoming path being countercurrent to the outgoing path.

42 ENGINEERING↗

Fabrication and Preliminary Demonstration of Microwave Resonant Cavity Transducer Performance

We are investigating a microwave cavity-based transducer for in-core high-temperature fluid flow sensing in molten salt cooled reactors (MSCR) and sodium fast reactors (SFR). This sensor is a hollow metallic cylindrical cavity, which can be fabricated from stainless steel, and as such is expected to be resilient to radiation, high temperature and corrosive environment of MSCR and SFR. The principle of sensing consists of making one wall of the cylindrical cavity flexible enough so that dynamic pressure, which is proportional to fluid velocity, will cause membrane deflection. Membrane deflection causes cavity volume change, which leads to a shift in the resonant frequency. We have developed an initial design for proof-of-principle testing of the flow sensor performance in microwave K-band. A cylindrical resonator prototype was fabricated from brass for initial tests in water. The cavity size is matched to the flange of a standard WR-42 waveguide. Microwave field is coupled into the resonant cavity through a subwavelength-size aperture. A test article was developed, consisting of a piping Tee with bulkhead WR-42 microwave waveguide installed in leak-proof design. In the test article, the cylindrical cavity is positioned in the center of the pipe. A microwave waveguide circulator was installed in the setup to suppress microwave reflections at the cavity entrance. Preliminary spectral characterization of cavity spectral response was performed with microwave VNA. Applying mechanical pressure to cavity membrane showed a measurable shift in the microwave resonant frequency. We also investigate mechanical integrity of the flowmeter’s membrane through computer simulations. By calculating the stress on the plate due to deflection and, comparing the stress to the material ultimate tensile strength and yield strength, it can be estimated if the plate will fail. The stress on the plate was calculated with an analytic closed form solution model, and with COMSOL Structural Mechanics Module which does not involve any approximations. Both the analytic model and COMSOL model showed that maximum stresses on the plate, which are at the radial boundary of the plate, are three orders of magnitude smaller than the yield strength and ultimate tensile strength. This indicates that the sensor is at a low risk of mechanical failure.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development, fabrication and calibration of a porous surface microphone in an aerofoil

The development of a porous surface microphone in an airfoil intended to measure acoustic signals in a turbulent airflow and to minimize the flow noise is described. The sensor because of its airfoil operates over a wide range of yaw angles and flow velocities without excessive flow noise. The acoustic properties of the porous materials used in the airfoil sensor and their effects on the frequency response of the sensor were analyzed and tested. An accurate airfoil was selected, having a smaller thickness-to-chord ratio and an airfoil sensor was designed. The sensor was calibrated acoustically and its flow noise evaluated in the quiet BBN wind tunnel at flow velocities up to 70 m/sec. Results are presented.

Noiseux, D. U.↗

Measurement of crossflow vortices, attachment-line flow, and transition using microthin hot films

A flow diagnostic experiment was conducted on a 45-deg swept-wing model using surface-mounted, multielement, microthin, hot-film sensors. The cross-flow vortex spacing, the attachment-line flow characteristics, and the transition region were all determined using an advanced data acquisition and instrumentation system. In addition to the frequencies of traveling waves predicted by linear stability theory, amplified disturbances at much higher frequencies were observed. Simultaneous measurements from sensors located at a number of chord and span locations highlighted the strong three-dimensionality of the boundary-layer flow in the presence of cross-flow vortices. The state of the attachment-line boundary layer was determined using a multielement sensor wrapped around the wing leading edge. The transition region flow characteristics were also identified.

Mangalam, S. M.↗

Diffractive Optic Fluid Shear Stress Sensor

Light scattering off particles flowing through a two-slit inteference pattern can be used to measure the shear stress of the fluid. We have designed and fabricated a miniature diffractive optic sensor based on this principle.

fluid shear stress micro sensor non-invasive senso↗