Search NASA⌕ Search

SEARCH · Search NASA

Results for “freezing level”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

An Innovative Zero-Liquid Discharge Intermediate-Cold-Liquid Eutectic-Freeze Desalination System

A novel freeze desalination technology is presented for purification of water produced from various industrial processes, including oil and gas extraction. The main innovative idea is introducing a water-immiscible intermediate-cold-liquid (ICL) medium which absorbs the cold from a refrigeration cycle and transfers it to a freezing chamber where it is mixed with brine. The cold ICL enters the freezing chamber at temperatures between -10°C to -30°C. Precooled brine in injected into the freezing chamber and pure water freezes out of the brine upon mixing with the ICL. The rate of freezing inside the chamber is controlled by adjusting the flow rate of the cold ICL relative to the inlet brine. Both eutectic freeze and non-eutectic freezing are possible by controlling the temperature of the freezing chamber. The solid-liquid slurry created in the freezing chamber flows to a filter separation unit after passing through a separation column. The ice crystals are separated from the liquid by a rotary filter device. The collected ice is rinsed by a centrifugal unit. The rinsed ice is melted to produce fresh water. The developed technology resolves the issues common to current freeze-desalination systems while offering superior heat transfer performance ascribed to direct-contact between the cooling medium and the brine in addition to producing solid salt and pure water. The system operates under atmospheric pressure. The low operation temperature minimizes the corrosion issues common in systems exposed to brine. Also, due to the low operating temperature, there are no concerns about evaporation of volatile organics from the produced water during the treatment. The developed technology effectively eliminates the use of chemicals for pretreatment of brine. The system can be constructed from commercially available components. Extensive testing using a lab-scale prototype by using synthetic brine and actual produced water with TDS values from 50,000 ppm to 300,000 ppm showed that freshwater could be achieved with relatively small dependency on the quality of the input brine. The quality of the treated water was found to be mainly a function of the duration of the centrifugal process. Treated water with TDS as low as 200 ppm could be achieved in the tests. Thermo-economic modeling coupled with system level thermochemical process model were developed for prediction of the LCOW. The LCOW was predicted to be $\$$0.50 to $\$$0.90 per barrel of produced water. The potential markets for deployment of the technology are the oil and gas, in-land thermoelectric powerplants, RO desalination plants, and mining industry.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

K ∗ (892) ± resonance production in Pb−Pb collisions at $\sqrt{s_{NN}}$ = 5.02 TeV

The production of K *⁢(892) ± meson resonance is measured at midrapidity (| y |<0.5) in Pb-Pb collisions at $\sqrt{^sNN}$ = 5.02 TeV using the ALICE detector at the CERN Large Hadron Collider. The resonance is reconstructed via its hadronic decay channel K *⁢(892) ± → K $^0_S$⁢π ± . The transverse momentum distributions are obtained for various centrality intervals in the p T range of 0.4-16 GeV/ c . Measurements of integrated yields, mean transverse momenta, and particle yield ratios are reported and found to be consistent with previous ALICE measurements for K *⁢(892) 0 within uncertainties. The p T -integrated yield ratio 2 K *⁢(892) ± ⁢/(⁢ K + + K - ) in central Pb-Pb collisions shows a significant suppression at a level of 9.3σ⁢ relative to pp collisions. Thermal model calculations result in an overprediction of the particle yield ratio. Although both hadron resonance gas in partial chemical equilibrium (HRG-PCE) and MUSIC + SMASH simulations consider the hadronic phase, only HRG-PCE accurately represents the measurements, whereas MUSIC + SMASH simulations tend to overpredict the particle yield ratio. These observations, along with the kinetic freeze-out temperatures extracted from the yields measured for light-flavored hadrons using the HRG-PCE model, indicate a finite hadronic phase lifetime, which decreases with increasing collision centrality percentile. The p T-differential yield ratios 2 K *⁢(892) ±⁢ /(⁢ K + + K - ) and 2 K *⁢(892) ± ⁢/(⁢π + +π - ) are presented and compared with measurements in pp collisions at $\sqrt{s}$ = 5.02 TeV. Both particle ratios are found to be suppressed by up to a factor of five at p T <2.0 GeV/ c in central Pb-Pb collisions and are qualitatively consistent with expectations for rescattering effects in the hadronic phase. The nuclear modification factor ( R AA ) shows a smooth evolution with centrality and is found to be below unity at p T >8 GeV/ c , consistent with measurements for other light-flavored hadrons. The smallest values are observed in most central collisions, indicating larger energy loss of partons traversing the dense medium.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Recent Changes in Arctic Sea Ice Melt Onset, Freeze-Up, and Melt Season Length

In order to explore changes and trends in the timing of Arctic sea ice melt onset and freeze-up and therefore melt season length, we developed a method that obtains this information directly from satellite passive microwave data, creating a consistent data set from 1979 through present. We furthermore distinguish between early melt (the first day of the year when melt is detected) and the first day of continuous melt. A similar distinction is made for the freeze-up. Using this method we analyze trends in melt onset and freeze-up for 10 different Arctic regions. In all regions except for the Sea of Okhotsk, which shows a very slight and statistically insignificant positive trend (O.4 days/decade), trends in melt onset are negative, i.e. towards earlier melt. The trends range from -1.0day/decade for the Bering Sea to -7.3 days/decade for the East Greenland Sea. Except for the Sea of Okhotsk all areas also show a trend towards later autumn freeze onset. The Chukchi/Beaufort Seas and Laptev/East Siberian Seas observe the strongest trends with 7 days/decade. For the entire Arctic, the melt season length has increased by about 20 days over the last 30 years. Largest trends of over 1O days/decade are seen for Hudson Bay, the East Greenland Sea the Laptev/East Siberian Seas, and the Chukchi/Beaufort Seas. Those trends are statistically significant a1 the 99% level.

Markus, Thorsten↗

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]↗

Shrubs Strongly Influence Snow Properties in Two Subarctic Watersheds

Understanding changes in snow distribution in permafrost ecosystems is fundamental to predicting their response to future climate change. The expansion of tall shrubs into tundra ecosystems can trap snow and insulate permafrost ecosystems during the winter, but the overall insulation effect is dependent upon many ecosystem properties. To study shrub–snow–ground interactions, small temperature sensors were deployed at two research sites on the Seward Peninsula of Alaska, USA, during the 2019–2020 winter. Snow temperatures were used to extrapolate multiple metrics, including freezing n-factors, the snow insulation effect, snow cover duration, and the length of the snowmelt period. Statistical and spatial analysis showed that shrub patches were a dominant control on all snow metrics. Within shrub patches, average ground temperatures were 2.1°C warmer, snow persisted 50 days longer, snow insulation was double, and a longer, later spring snowmelt period occurred compared to nonshrubby areas. Site-level differences contributed relatively little to variation in snow metrics, indicating that shrub presence is an overarching driver of snow–ground interactions at the locations examined. Shrub expansion, which is anticipated under climate change, will strongly impact future permafrost distribution and Arctic energy, water, and carbon cycles through snow–shrub–ground feedbacks.

54 ENVIRONMENTAL SCIENCES↗

Liquid Salt Combined-Cycle Pilot Plant Design

The work described in this report is responsive to the Office of Fossil Energy program ‘Energy Storage for Fossil Power Generation.’ This Phase I report has been prepared by Pintail Power LLC, with support from Nexant ECA, Electric Power Research Institute (EPRI) and Southern Company Services as a deliverable for the U.S. Department of Energy for NETL Award DE-FE-00320016. The Liquid Salt Combined Cycle™ (LSCC™) technology provides large-scale energy storage integrated with Fossil Electric Generating Units (FEGUs) to meet critical needs in the energy transition by providing: • the lowest cost large-scale storage for time-shifting of renewable energy, • superior fuel efficiency to reduce GHGs from dispatchable resources, • flexible capacity and ramping to balance variability of wind and solar resources, • essential grid stability services to assure reliability of a low-carbon grid. The LSCC approach: • employs equipment that has already been proven in utility service, • uses safe, non-toxic, non-degrading, perpetual-life storage medium, • leverages and repurposes existing FEGU assets, • expands the value stack of energy storage to reduce market, financing, and commodity risks. Pintail Power has developed the LSCC technology to meet the need for reliable, efficient, and cost-effective integration of Variable Renewable Energy (VRE) into a low-carbon electric grid by coupling proven thermal energy storage with proven gas turbines, steam turbines, and heat transfer equipment. This novel approach is intended to address the key issues facing the grid and operators of renewable and fossil generating units including: • Overgeneration and curtailment of renewables, • Need for fast ramping dispatchable resources, • Improved efficiency and flexibility of fossil units, • Additional peaking capacity to support electrification of transportation and heating, • Provision of reliability services to support high penetration of VRE, especially synchronous inertia and fast frequency response. A Technology Readiness assessment by EPRI confirmed that LSCC technology consists of commercially proven hardware used in industrial and utility applications. Although the novel LSCC approach has not yet been demonstrated as a complete system, interfaces between major components have been conservatively specified. A Phase III pilot is planned to demonstrate equipment integration and operation. The patented innovation is removal of the evaporator section from the exhaust heat recovery system, with the evaporation performed by stored energy in a separate steam generator. This arrangement couples renewable and fossil power generation via long-duration energy storage to deliver cost, performance, and operational synergies, including superior charging and discharging flexibility, reduced fuel consumption and lower CO 2 emissions compared to conventional Combined Cycle Power Plants, and low-cost, large-scale energy storage. The LSCC technology is composed of proven equipment integrated with gas turbine exhaust heat in a novel system. During charging, electric heaters raise the salt temperature as it flows from the Cold Salt Tank to the Hot Salt Tank. During discharging, hot salt produces steam from feedwater that is heated with gas turbine exhaust, which also superheats steam to drive a steam turbine. LSCC technology can be added to any combustion-turbine to integrate renewable energy, provide needed grid services, and increase the value of fossil electric generating units based on the technology’s following attributes: • Long-duration storage enables time-shifting of VRE to avoid curtailment and impairment of renewable assets. • Long storage duration combined with fast-charging capability increases arbitrage opportunities by storing more energy when the price is low and discharging more hours when the price is high. • Long storage duration allows resource adequacy to be supplied across multiple days to increase reliability and reduce risk. • The stored energy reduces fuel heat rate and GHG emissions, and increases merit, so the LSCC dispatches earlier and longer to increase the plant’s capacity factor and asset value. • The stored energy enables pre-heating and startup of the steam cycle, without operating the gas turbine, to enable fast startup and ramping when dispatched for discharge. • The steam turbine can operate without the gas turbine so it can provide valuable synchronous inertia during charging without consuming fuel. • Fast frequency response and regulation services can be provided during charging using solid-state heater and pump controls to vary the charge power input in response to grid signals. • The LSCC system can be configured for resilience including black start, islanded/micro-grid operation, and even self-recharging of storage using either gas turbine power or gas turbine exhaust heat. The commercialization plan is to add LSCC technology to existing simple cycle gas turbine power plants with the 50MW GE LM6000 aero-derivative gas turbine as the reference design basis. A Techno-economic assessment of the reference design evaluated the benefits (Levelized Avoided Cost of Energy) and costs (Levelized Cost of Energy). The plant definition included all major systems and budgetary vendor quotes. Pintail Power and NexantECA developed the overall cost estimate for the LSCC plant up to the total plant cost level, following the DOE-NETL cost estimate guidelines at AACE Class 3 (-20%/+30%). This includes the equipment cost, bulk material, direct and indirect labor costs to arrive at the bare erected cost. Engineering costs are factored from the BEC and added to it to arrive at the EPC cost. Process and project contingencies were then factored from the EPC cost and rolled-up to yield the total plant cost of $\$$184 million for 1746 MWh of discharge electricity. • At $\$$105/kWh, the reference plant costs less than any of the Energy Storage Systems evaluated by PNNL in 2020 for the Energy Storage Grand Challenge. Operations and Maintenance cost estimates were scaled from combined cycle practice, assuming that the LSCC unit was co-located with and sharing some labor expense with other units, to arrive at $\$$2.2 million per year. Plant economics were evaluated using prices from the ERCOT Day-Ahead Market for calendar year 2019 (excluding the market disruptions from the COVID pandemic and the February 2020 deep freeze event). Assuming economic dispatch in the ERCOT Day-Ahead market, the reference plant capacity factor would have discharged for 2777 hours at 91.9 MW, a 31.66% capacity factor, with a marginal cost of $\$$25.59/MWh, and a LACE of $\$$82.41/MWh. Fixed charges were calculated according to EIA guidelines to arrive at an LCOE of $\$$83.48. The benefit-to-cost ratio of 0.99 suggests that the reference plant would have been cost-effective and competitive in the market. EPRI interviewed selected utilities to gauge the need for, applicability of and interest in the LSCC system. Several utilities are currently managing increased load growth along with the inclusion of increasing levels of renewable generation, putting pressure on conventional generation by requiring increased turndown requirements and ultimately lower capacity factors. All of the utilities interviewed have CO 2 reduction targets in the 2030-2050 timeframe that will severely limit the participation of fossil generation and require better utilization of carbon free generation. While there is limited opportunity for storage in the current markets, the utilities interviewed stated that there will be a substantial need for long duration energy storage in the future given the expected trends. Utilizing an energy storage system will generally be preferred over new gas capacity in some cases, with the capabilities of the LSCC system being a potential option for retrofit to existing simple cycle gas turbine units, allowing them to deliver greater participation in the market with lower carbon intensity. A technology gap assessment and technology maturation plan identified a pilot-scale demonstration as the final step before commercialization. Key gaps to be addressed during the Phase II FEED (Front-End Engineering Design) are component selection and design, commissioning procedures, and operational procedures and the control system for LSCC charging and discharging. The project team has been expanded to include Wood Group PLC as EPC. The proposed Phase II work leads to a pilot-scale engineering demonstration (TRL 6) to be conducted at Southern Company’s Plant Rowan, where the prototype system will perform “all the functions that will be required of the operational system.” The proposed pilot will facilitate commercialization (TRL-9) by scale-up to utility-scale systems integrated with peaking GTs or directly to facility scale systems using industrial GTs. The conceptual design for the pilot plant focuses on the novel integration aspects of LSCC technology. A slipstream of gas turbine exhaust will feed a waste heat recovery unit coupled to a molten salt steam generator heated by stored energy. The pilot is intended to demonstrate all key operating modes of the LSCC technology during charging, discharging and standby. The pilot equipment will be approximately one-seventh scale of the LM6000 commercial target and is expected to have commercial off-ramp potential for facility-scale applications.

01 COAL, LIGNITE, AND PEAT↗

A Comparative Analysis of Lithium-Ion Battery Chemistries for Cold-Climate Maritime Applications

Energy storage, primarily in the form of electrochemical batteries, is critical for enabling integration of marine energy (e.g., power from waves and currents) with end-use applications at sea due to the periodicity of the resources and requirement of consistent, smooth power delivery. Powering high-latitude coastal or ocean-based observing systems has been identified as a high value-proposition use case, exemplifying the concept of Powering the Blue Economy. An existing power system implementation for such a platform uses solar panels coupled to rechargeable lithium-ion batteries, augmented by a non-rechargeable backup bank used to power heaters in winter months. As wave energy is a potential resource for powering this and similar use cases and is strongest when solar power is most limited, it was hypothesized that integration of wave power would alleviate some of the challenges in cold climates related to energy storage. In this work, we investigate the use case scenario in simulation and perform a comparative test of commercially-available lithium-ion battery chemistry formulations to determine the most appropriate choice for the application. The experiment compared the most commonly-used lithium-based battery types (NCM, NCA, and LFP) in laboratory conditions emulating a battery enclosure thermally coupled to freezing seawater using an industrial battery performance tester in PNNL's arctic simulation lab. Battery strings were repeatedly cycled (i.e., charged, discharged, rested) and their usable capacity was measured. Both NCM and NCA strings exhibited degradation upon cycling, while the LFP string maintained stable operation through over 700 complete cycles. Though lower in baseline capacity, LFP are recommended for this and similar low-temperature applications with access to high levels of bulk charging current (e.g., from high-energy wave events) and their use may reduce the cost and complexity of battery conditioning and protection apparatus.

16 TIDAL AND WAVE POWER↗

Advanced Liquid-Cooling Garment Using Highly Thermally Conductive Sheets

This design of the liquid-cooling garment for NASA spacesuits allows the suit to remove metabolic heat from the human body more effectively, thereby increasing comfort and performance while reducing system mass. The garment is also more flexible, with fewer restrictions on body motion, and more effectively transfers thermal energy from the crewmember s body to the external cooling unit. This improves the garment s performance in terms of the maximum environment temperature in which it can keep a crewmember comfortable. The garment uses flexible, highly thermally conductive sheet material (such as graphite), coupled with cooling water lines of improved thermal conductivity to transfer the thermal energy from the body to the liquid cooling lines more effectively. The conductive sheets can be layered differently, depending upon the heat loads, in order to provide flexibility, exceptional in-plane heat transfer, and good through-plane heat transfer. A metal foil, most likely aluminum, can be put between the graphite sheets and the external heat source/sink in order to both maximize through-plane heat transfer at the contact points, and to serve as a protection to the highly conductive sheets. Use of a wicking layer draws excess sweat away from the crewmember s skin and the use of an outer elastic fabric ensures good thermal contact of the highly conductive underlayers with the skin. This allows the current state of the art to be improved by having cooling lines that can be more widely spaced to improve suit flexibility and to reduce weight. Also, cooling liquid does not have to be as cold to achieve the same level of cooling. Specific areas on the human body can easily be targeted for greater or lesser cooling to match human physiology, a warmer external environment can be tolerated, and spatial uniformity of the cooling garment can be improved to reduce vasoconstriction limits. Elements of this innovation can be applied to other embodiments to provide effective heat transfer over a flexible and surface-conformable fashion without the limitation of fluid freeze points.

Ruemmele, Warren P.↗

The Role of Ice Splintering on Microphysics of Deep Convective Clouds Forming Under Different Aerosol Conditions: Simulations Using the Model With Spectral Bin Microphysics

Observations during the Ice in Clouds Experiment-Tropical (ICE-T) field experiment show that the ice particles concentration in a developing deep convective clouds at the level of T = -15 °C reached about 500 L -1 , that is, many orders higher than that of ice-nucleating particle. To simulate microphysics of these clouds, the 2-D Hebrew University Cloud model (HUCM) with spectral bin microphysics was used in which two main types of ice multiplication mechanisms were included in addition to the Hallet-Mossop mechanism. In the first ice multiplication mechanism ice splinters form by drop freezing and drop-ice collisions. Ice multiplication of this type dominates during developing stage of cloud evolution, when liquid water content is significant. At later stage when clouds become nearly glaciated, ice crystals are produced largely by ice splintering during ice-ice collisions (the second ice multiplication mechanism). Simulations show that droplet size distributions, as well as size distributions of ice particles, agree well with the measurements during ICE-T. Simulations with different cloud condensation nuclei concentrations show the existence of the “optimum” cloud condensation nuclei concentration (or droplet concentration), at which concentration of ice splinters reaches maximum. In these simulations ice nucleation caused by the direct formation of ice crystals upon ice-nucleating particles, as well as the Hallett-Mossop process, has a negligible contribution to the ice crystal concentration.

54 ENVIRONMENTAL SCIENCES↗

(Invited) All-Solid-State Batteries Using Li 7 La 3 Zr 2 O 12 Garnet Electrolyte Framework

All-solid-state batteries (ASSB) using LLZO (variants of Li 7 La 3 Zr 2 O 12 ) garnet solid electrolyte with lithium metal anode potentially offer higher energy density and improved safety. Rational design of cell architecture as well as manufacturing scalability are key aspects to consider as the technology readiness level advances. A thick composite cathode layer attached to a thin solid electrolyte layer is desirable to obtain superior energy densities. Furthermore, the architecture within the composite cathode may be engineered to contain directional conduction paths of lithium ions or electrons for enhanced rate capabilities. Here, we demonstrate a functioning bulk-type LLZO based all-solid-state battery with a practical form factor incorporating the above described design concepts. Freeze-tape-casting (FTC), a scalable and environmentally friendly ceramic processing method, is used to construct 3D porous LLZO scaffolds composed of vertical arrays of LLZO walls. The thin solid-electrolyte layer is fabricated by tape-casting (TC). By sintering the stacks of FTC and TC green tapes, porous/dense bilayers and porous/dense/porous trilayers of LLZO frameworks are obtained. An ASSB was constructed using a porous/dense bilayer by infiltrating LiNi 0.6 Mn 0.2 Co 0.2 O 2 cathode powder and carbon black into the porous layer and adhering lithium metal foil to the dense side. We find it crucial to introduce a plastic crystal based soft solid electrolyte to the porous layer to electrochemically connect all cathode components, obviating the need for co-sintering to establish contact. The soft nature of the plastic crystal based solid-electrolyte may be able to accommodate the volume change of the cathode material as it cycles. In this device, which contained no liquid component, the initial discharge capacities were similar to those observed in a lithium ion battery configuration using the same cathode powder at C/10 rates.

25 ENERGY STORAGE↗

RANS Simulation of Variable Density Turbulent Round Jets with Coflow using xRAGE Hydrodynamic Code and BHR Turbulence Models

This work for the fiscal year 2023 (FY23) is a continuation of previous efforts to evaluate the BHR turbulence models for their ability to accurately simulate variable density turbulent round jets with coflow. As before, RANS simulations are carried out using the xRAGE hydrodynamic code. The following are some of the previous findings. Israel showed that i) the symmetry boundary conditions for the BHR models in axisymmetric simulations were in error, ii) three grids of different resolutions did not lead to converging solutions, and iii) BHR 3.1 simulation exhibited instabilities and did not reach a steady state. Saenz and Rauenzahn derived and implemented into xRAGE the correct BHR boundary conditions at the symmetry axis. Cline conducted sensitivity studies with various parameters including the BHR models (versions 2, 3.1 and 4), gravity, material pressure, specific heat, initial turbulent kinetic energy and initial turbulent length scale, and found that the largest factor impacting on simulation results was the BHR model version, followed by the initial turbulent length scale. In addition, freeze boundary conditions at the exit and the side wall of the computational domain were used to remove anomalous flow behavior. Cline adjusted the inlet jet velocity, initial turbulent kinetic energy and initial turbulent length scale to obtain the best reasonable match with the experimental data of Charonko and Prestridge. It was found that the BHR 2 and 3.1 models performed in a similar manner, but the BHR 2 model produced much lower levels of density-specific-volume covariance and turbulent kinetic energy. The main focus for the FY23 is to study the effects of computational parameters related to the boundary conditions, mesh, domain size and timestep size. The reasoning behind this is that, unless simulation results can be shown to be reasonably independent from the aforementioned computational parameters, it would be difficult to attribute any discrepancies between simulation and experimental results to turbulence models. This important aspect has largely been overlooked in the previous years, and therefore will be studied comprehensively here. Additionally, effects of varying the initial turbulent length scale will be examined because it was previously identified as a major factor affecting the flow fields.

42 ENGINEERING↗

Three-Dimensional Ultrastructure of Arabidopsis Cotyledons Infected with Colletotrichum higginsianum

We used serial block-face scanning electron microscopy (SBF-SEM) to study the host–pathogen interface between Arabidopsis cotyledons and the hemibiotrophic fungus Colletotrichum higginsianum. By combining high-pressure freezing and freeze-substitution with SBF-SEM, followed by segmentation and reconstruction of the imaging volume using the freely accessible software IMOD, we created 3D models of the series of cytological events that occur during the Colletotrichum–Arabidopsis susceptible interaction. We found that the host cell membranes underwent massive expansion to accommodate the rapidly growing intracellular hypha. As the fungal infection proceeded from the biotrophic to the necrotrophic stage, the host cell membranes went through increasing levels of disintegration culminating in host cell death. Intriguingly, we documented autophagosomes in proximity to biotrophic hyphae using transmission electron microscopy (TEM) and a concurrent increase in autophagic flux between early to mid/late biotrophic phase of the infection process. Occasionally, we observed osmiophilic bodies in the vicinity of biotrophic hyphae using TEM only and near necrotrophic hyphae under both TEM and SBF-SEM. Overall, we established a method for obtaining serial SBF-SEM images, each with a lateral ( x-y) pixel resolution of 10 nm and an axial ( z) resolution of 40 nm, that can be reconstructed into interactive 3D models using the IMOD. Application of this method to the Colletotrichum–Arabidopsis pathosystem allowed us to more fully understand the spatial arrangement and morphological architecture of the fungal hyphae after they penetrate epidermal cells of Arabidopsis cotyledons and the cytological changes the host cell undergoes as the infection progresses toward necrotrophy. [Formula: see text] Copyright © 2024 The Author(s). This is an open access article distributed under the CC BY 4.0 International license .

Biochemistry & Molecular Biology↗

System Level Analysis of a Water PCM HX Integrated into Orion's Thermal Control System

In a cyclical heat load environment such as low Lunar orbit, a spacecraft's radiators are not sized to reject the full heat load requirement. Traditionally, a supplemental heat rejection device (SHReD) such as an evaporator or sublimator is used to act as a "topper" to meet the additional heat rejection demands. Utilizing a Phase Change Material (PCM) heat exchanger (HX) as a SHReD provides an attractive alternative to evaporators and sublimators as PCM HXs do not use a consumable, thereby leading to reduced launch mass and volume requirements. In continued pursuit of water PCM HX development an Orion system level analysis was performed using Thermal Desktop for a water PCM HX integrated into Orion's thermal control system in a 100km Lunar orbit. The study verified of the thermal model by using a wax PCM and analyzed 1) placing the PCM on the Internal Thermal Control System (ITCS) versus the External Thermal Control System (ETCS) 2) use of 30/70 PGW verses 50/50 PGW and 3) increasing the radiator area in order to reduce PCM freeze times. The analysis showed that for the assumed operating and boundary conditions utilizing a water PCM HX on Orion is not a viable option for any case. Additionally, it was found that the radiator area would have to be increased by at least 40% in order to support a viable water-based PCM HX.

Navarro, Moses↗

Native Defect Related Optical Properties of ZnGeP2

We present photoluminescence, photoconductivity, and optical absorption spectra for ZnGeP2 crystals grown from the melt by gradient freezing and from the vapor phase by high pressure physical vapor transport (HPVT). A model of donor and acceptor related subbands in the energy gap of ZnGeP2 is introduced that explains the experimental results. The emission with peak position at 1.2 eV is attributed to residual disorder on the cation sublattice. The lower absorption upon annealing is interpreted in terms of both the reduction of the disorder on the cation sublattice and changes in the Fermi level position. The n-type conductivity of ZnGeP2 Crystals grown under Ge-deficient conditions by the HPVT is related to the presence of additional donor states.

Dietz, N.↗

Crystal Growth and Characterization of CdTe Grown by Vertical Gradient Freeze

In this study, crystals of CdTe were grown from melts by the unseeded vertical gradient freeze method. The quality of grown crystal were studied by various characterization techniques including Synchrotron White Beam X-ray Topography (SWBXT), chemical analysis by glow discharge mass spectroscopy (GDMS), low temperature photoluminescence (PL), and Hall measurements. The SWBXT images from various angles show nearly strain-free grains, grains with inhomogeneous strains, as well as twinning nucleated in the shoulder region of the boule. The GDMS chemical analysis shows the contamination of Ga at a level of 3900 ppb, atomic. The low temperature PL measurement exhibits the characteristic emissions of a Ga-doped sample. The Hall measurements show a resistivity of 1 x l0(exp 7) ohm-cm at room temperature to 3 x 10(exp 9) ohm-cm at 78K with the respective hole and electron concentration of 1.7 x 10(exp 9) cm(exp -3) and 3.9 x 10(exp 7) cm(exp -3) at room temperature.

Su, Ching-Hua↗

SFWST Disposal Research R&D 5-Year Plan - FY2021 Update.

In the planning for FY2020 in the U.S. DOE NE-81 Spent Fuel and Waste Science and Technology (SFWST) Campaign, the DOE requested development of a plan for activities in the Disposal Research (DR) Research and Development (R&D) over a five (5)-year period, and DOE requested periodic updates to this plan. The DR R&D 5-year plan was provided to the DOE based on the FY2020 priorities and program structure (Sassani et al., 2020) and represents a strategic guide to the work within the DR R&D technical areas (i.e., the Control Accounts), focusing on the highest priority technical thrusts. This FY2021 report is the first update to the DR R&D 5-year plan for the SFWST Campaign DR R&D activities. This 5-year plan will be a living document and is planned to be updated periodically to provide review of accomplishments and for prioritization changes based on aspects including mission progress, external technical work, and changes in SFWST Campaign objectives and/or funding levels (i.e., Program Direction). The updates to this 5-year plan will address the DR R&D that has been completed (accomplishments) and the additional knowledge gaps to be investigated, with any updates to the DR R&D priorities for the next stages of activities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Arctic Aerosol Sources and Mixing States Field Campaign Report

The Arctic is warming at a faster rate than anywhere else on Earth, with rapidly shrinking sea ice extent transforming the region. Depending on chemical and physical properties, atmospheric aerosols directly scatter and/or absorb radiation, serve as cloud droplet and/or ice crystal nuclei, and/or reduce the reflectiveness of the snow surface, thereby altering the atmospheric energy budget. There is a wide spread in the magnitude of simulated arctic aerosol radiative forcing, and significant differences in aerosol concentration levels and seasonal cycles often exist between models and observations. Increasing local natural and anthropogenic emissions are significant, with uncertain climate impacts due to complex feedbacks. Model evaluations, however, are limited by the dearth of arctic aerosol observations available and an inadequate understanding of arctic aerosol processes. The majority of previous arctic aerosol observations have been made through intensive spring/summer field campaigns, with few intensive measurement studies focused on the fall-winter transition, a period when freeze-up is occurring later and thinning sea ice is resulting in wintertime ice fracturing. Aerosol monitoring at arctic coastal stations has provided knowledge of long-term seasonal trends in aerosol concentrations. The completed ARM field campaign addresses observational and knowledge gaps through detailed aerosol size and chemical composition measurements during the fall-winter transition in the coastal Arctic and through the entire annual cycle in the central Arctic. The observations are improving our understanding of the sources and processes controlling the aerosol population in the rapidly changing Arctic.

54 ENVIRONMENTAL SCIENCES↗

Irradiating of Bulk Soybeans: Influence on Their Functional and Sensory Properties for Soyfood Processing

Soybeans were chosen for lunar and planetary missions, where soybeans will be supplied in bulk or grown locally, due to their nutritive value and ability to produce oil and protein for further food applications. However, soybeans must be processed into foods prior to consumption. Radiation that soybeans would be exposed to during bulk storage prior to and during a Mars mission may influence their germination and functional properties. The influence of radiation includes the affect of surface pasteurization to ensure the astronauts safety from food-borne illnesses (HACCP, CCP), and the affect of the amount of radiation the soybeans receive during a Mars mission. Decreases in the amount of natural antioxidants free radical formation, and oxidation-induced changes in the soybean will influence the nutritional value, texture, color, and aroma of soyfoods. The objective of this study was to determine the influence of pasteurization and sterilization surface radiation on whole soybeans using gamma and electron beam radiation. The influence of 0, 1, 5, 10, and 30kGy on microbial load, germination rate, ease of processing, and quality of soymilk and tofu were determined. Surface radiation of whole dry soybeans using electron beam or gamma rays from 1-30kGy did provide microbial safety for the astronauts. However, the lower dose levels had surviving yeasts and molds. These doses caused oxidative changes that resulted in soymilk and tofu with rancid aromas. GC-MS of the aroma compounds using SPME Headspace confirmed the presence of lipid oxidation compounds. Soybean germination ability was reduced as radiation dosage increased. While lower doses may reduce these problems, the ability to insure microbial safety of bulk soybeans will be lost. Counter measures could include vacuum packaging, nitrogen flushing, added antioxidants, and radiating under freezing conditions. Doses below 1kGy need to be investigated further to determine the influence of the radiation encountered during Mars missions.

Chia, Chiew-Ling↗