Search NASA⌕ Search

SEARCH · Search NASA

Results for “gamma spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Thermal impacts on nondestructive analysis measurements of uranium hexafluoride

A series of nondestructive assay measurements were performed before, during, and after localized heating of an industrial standard 12B cylinder of uranium hexafluoride to replicate dose variations previously observed on commercial 30B cylinders. While cylinders represent a closed system, enrichment measurements may be impacted by altered uranium and daughter product distributions due to sublimation. A series of measurements were performed to examine localized heating impacts on dose rates, ratios of uranium and daughter product distributions, and measured 235 U enrichment as calculated by two different approaches. The less complex enrichment meter approaches were found to be more robust and less prone to deviation than isotope ratio approaches such as FRAM, but the impact can be minimized by using observable dose changes to avoid impacted areas.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Isotopic gamma lines for identification of shielding materials

Identifying the constituting materials of concealed objects is crucial in a wide range of sectors, such as medical imaging, geophysics, nonproliferation, national security investigations, and so on. Existing methods face limitations, particularly when multiple materials are involved or when there are challenges posed by scattered radiation and large areal mass. Here we introduce a novel brute-force statistical approach for material identification using high spectral resolution detectors, such as HPGe. The method relies upon updated semianalytic formulae for computing uncollided flux from source of gamma radiation, shielded by a sequence of nested spherical or cylindrical materials. These semianalytical formulae make possible rapid flux estimation for material characterization via combinatorial search through all possible combinations of materials, using a high-resolution HPGe counting detector. An important prerequisite for the method is that the geometry of the objects is known (for example, from X-ray radiography). We demonstrate the viability of this material characterization technique in several use cases with both simulated and experimental data in spherical geometry.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Cobalt-60, Barium-133, Cesium-137, and Europium-152 migration from cementitious sources through sediment under field conditions

Safe and effective storage of radioactive waste is essential to protect human and environmental health. Due to the potential for accidental releases and the severity of the associated risks, it is imperative to further understand radionuclide transport should an accident occur. This study was the second set of measurements conducted in 2022 of an ongoing experiment that has analyzed the vadose zone migration of radionuclides from cementitious wasteforms at the Savannah River Site over the last ten years. The radionuclides introduced within the sources are prominent constituents of radioactive waste or analogs for other groups or series of radionuclides. Lysimeters were first analyzed in 2016 using a collimated high-purity germanium gamma-ray spectrometer to non-destructively measure the concentration of each radionuclide in the sediment column as a function of depth. Following these measurements, the lysimeters were redeployed for another 4 years. All radionuclides in all lysimeters were observed to transport further during the redeployment period; however, the extent of migration varied with the material used for introduction. Except for 137Cs, migration through the sediment control system increased with decreasing ionic potential (ionic charge/radius); migration order: 152Eu<137Cs<60Co<133Ba. Overall, the cementitious wasteforms were observed to decrease radionuclide migration extent relative to natural vadose zone conditions. In both cementitious wasteforms, the migration extent increased in the order 152Eu<133Ba<60Co<137Cs. However, less migration was measured when the radionuclides were incorporated into a reducing grout wasteform. The novelty of this paper is the demonstration of a technique capable of creating non-destructive measurements over decade time scales. Ultimately, this work provides insight into the long-term migration of alkali, alkali earth, divalent transition metal, and trivalent (e.g., lanthanide and actinide element) isotopes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of gamma-ray spectral analysis methods for thick-walled UF 6 cylinders

Three data analysis methods were compared for gamma ray spectra collected by planar and coaxial high-purity germanium detectors (HPGe) on thick-walled uranium hexafluoride cylinders. The cylinder contents range from natural to low-enriched uranium (4.95% 235 U). Each spectrum was analyzed with the traditional 185.7 keV enrichment meter method, a 185.7/1001 keV ratio method, and the Fixed Energy Response Function Analysis with Multiple Efficiency (FRAM) software that utilizes low- and high-energy gamma rays and X-rays. When results for all cylinders were compared, the enrichment meter method and the 185.7/1001 keV peak ratio method consistently provided the most accurate data for all detector types. The error on the enrichment calculations analyzed with FRAM did not meet the international target value whereas those calculated with the enrichment meter and ratio method did. Enrichments calculated by FRAM were found to skew to higher values on natural uranium and to lower values on low-enriched uranium. FRAM calculated the least-precise enrichments; replicate analyses of single cylinders resulted in 235 U values that varied by as much as 19%. FRAM does have the significant advantages in that it does not require the use of calibration cylinders, infinite thickness criteria are not necessary, and it can be applied to any HPGe detector. Finally, if calibration cylinders are available, the enrichment meter and 185.7/1001 peak ratio are the recommended methods as they are the most accurate and precise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Crystal growth, density functional theory, and scintillation properties of Tl 3 LnCl 6 :Ce 3+ and TlLn 2 Cl 7 :Ce 3+ (Ln = Y, Gd)

In this paper we report on the crystal growth, density functional theory (DFT) calculations and scintillation properties of Tl 3 LnCl 6 :Ce and TlLn 2 Cl 7 :Ce(Ln = Y, Gd). Crystals were grown by the Vertical Bridgman technique up to 16 mm in diameter and 25 mm long. Crystals of Tl 3 YCl 6 :Ce and Tl 3 GdCl 6 :Ce belong to the family of the Nesohalides which have the monoclinic crystal structure. Crystals of TlY 2 Cl 7 :Ce and TlGd 2 Cl 7 :Ce belong to the family of the Phyllohalides which have either the monoclinic or the orthorhombic crystal structure. We report the light yields of these Nesohalides and Phyllohalides are typically on the order of 35,000–40,000 ph/MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The GALILEO γ-ray array at the Legnaro National Laboratories

GALILEO, a new 4 pi high-resolution gamma-detection array, based on HPGe detectors, has been developed and installed at the Legnaro National Laboratories. The GALILEO array greatly benefits from a fully-digital readout chain, customized DAQ, and a variety of complementary detectors to improve the resolving power by the detection of particles, ions or high-energy gamma-ray transitions. In this paper, a full description of the array, including electronics and DAQ, is presented together with its complementary instrumentation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Photon detector response function methodology using MCNP and shift hybrid radiation transport code for wide-area contamination assay applications

Here, radiation transport modeling using the Monte Carlo N-Particle (MCNP) radiation transport code and Monte Carlo code, Shift, were employed to model detector responses for a variety of wide-area photon contamination scenarios. In this study, 2" × 2" and 3" × 3" cylindrical NaI(Tl) scintillation detector configurations at source detector-distances of 0.5 cm, 1 cm, 2.54 cm, 10 cm, and 30 cm were modeled. Media of soil, concrete, and steel were evaluated for contamination depths ranging from surface to a depth of an infinite thickness in each medium for photon energies ranging from 20 keV to 3 MeV, which correspond to the energies that current detectors can discern. Monoenergetic photon surface contamination detector responses for each of the media, source–detector distances, and detectors were estimated using MCNP v6.2. Shift was harnessed for improved variance reduction of particle transport in highly attenuating media to obtain average cell fluxes in the two MCNP NaI(Tl) scintillation detector configurations. Average cell flux values in Shift were coupled with detector responses from MCNP to convert average cell flux in a void to energy distribution of pulses in the NaI(Tl) scintillation detector crystal of interest. An optimized detector response function methodology was developed by coupling the MCNP radiation transport method with the Consistent Adjoint Driven Importance Sampling (CADIS) hybrid radiation transport method built into Shift to significantly decrease the runtime of thousands of MCNP pulse height simulations. The methodology may be utilized to quickly and accurately facilitate the assessment of a broad range of wide-area environmental contamination assay and decommissioning cleanup applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New method for level-lifetime measurements with thick scintillators

Level lifetimes provide key insight into the structure of atomic nuclei and serve as stringent tests of theoretical descriptions. Though several methods for determining level lifetimes exist for both reaction measurements and decay studies, here the focus is on techniques involving the direct measurement of time differences between population and subsequent depopulation of excited states. The techniques presented herein are broadly applicable across multiple timing ranges, but the approach is specifically described for the βγ timing method. A multi-step, amplitude-dependent time walk correction was employed to address the data analysis complications that arise from using thick scintillators for electron detection. Further, additional corrections for the depth of the interaction must also be performed when the parent isotope has been implanted into the detector. Techniques are presented for performing these time walk and depth of interaction corrections. Subsequently, a new Monte Carlo method utilizing measured detector responses obtained from the data, coupled with chi-square minimization, is presented for extracting excited state lifetimes ≳ 100 picoseconds. The framework of this Monte Carlo method is developed for the decay of a state in 68 Zn with a known 1.6 ps half life, which is considered prompt given the detection sensitivity of the technique, and then benchmarked using two other excited states in neutron-rich Ni isotopes with 120(34) ps and 1.05(3) ns half lives. Using this new method which takes into account the thick scintillator used, these same half lives were measured to be 135(10) ps and 1.04(24) ns, respectively. The overall good agreement demonstrates the validity of the technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

γIn-beam angular distribution and linear polarization measurements with GRETINA using a simple energy-ordering approach

Angular distribution and linear polarization measurements are powerful tools for inferring the spins and parities of nuclear levels. In this work, the performance of the Gamma-Ray Energy Tracking In-beam Nuclear Array (GRETINA) as a Compton polarimeter was characterized in a fusion-evaporation reaction experiment using a simple energy-ordering approach for the interaction points assigned in the signal decomposition process. A variety of multipolarities and characters for γ-ray transitions in the reaction products 25 Mg, 25 Na, and 22 Ne, formed from fusion-evaporation of an 18 O beam on a 9 Be target, were examined. The experimental angular distributions and linear polarization asymmetries were consistent with predictions using the theoretical formalism accounting for the Lorentz boost.

Angular distribution↗

Algorithms for coordinate reconstruction in position-sensitive virtual Frisch-grid detectors

Arrays of position-sensitive virtual Frisch-grid (VFG) CdZnTe (CZT) detectors provide a cost-effective solution for integrating large-area arrays for gamma-ray imaging and spectroscopy. These detectors employ high-aspect ratio CZT crystals (bars) with thicknesses up to 50 mm and cross-sections of up to 10 × 10 mm 2 . Despite the long drift distances of charge carriers in such crystals, the detectors have demonstrated excellent performance, achieving energy resolutions better than 1 % full width at half maximum (FWHM) at 662 keV and 3D position resolutions finer than 1 mm. The high spatial resolution is a critical feature of these detectors, as it enables correction of response non-uniformities caused by crystal defects, which remain present even in the highest-quality CZT material. Dislocations and dislocation walls are the primary defects responsible for variations in charge carrier losses as they drift from the interaction points toward the charge-collecting electrodes. The mechanism by which these defects affect carrier transport is generally well understood. Dislocations and sub-grain boundaries act as sinks for carrier-trapping centers, primarily impurities and secondary phases such as tellurium inclusions and precipitates. Here, these regions exhibit significantly higher carrier-trapping rates, leading to variations in the μτ-products. Because the locations of these micron-sized regions are fixed within the detector volume, fluctuations in the total collected charge arise from the random distribution of interaction sites. This results in non-uniform detector responses and degradation of energy resolution. However, by measuring the interaction-site locations with sufficient precision, charge-loss variations can be accurately corrected, allowing recovery of nearly intrinsic energy resolution.

47 OTHER INSTRUMENTATION↗

Beam test performance of AstroPix sensor with 120 GeV protons

AstroPix is a High-Voltage CMOS Monolithic Active Pixel Sensor (HV-CMOS MAPS) developed for precision gamma-ray imaging and spectroscopy in the medium-energy regime, as well as for precise shower imaging and tracking in the Barrel Imaging Calorimeter (BIC) of the Electron Proton/Ion Collider (ePIC) detector at the future Electron–Ion Collider (EIC). We present beam test results of the AstroPix_v3 sensor using a 120 GeV proton beam at the Fermilab Test Beam Facility (FTBF), performed as part of the broader experimental campaign for the BIC prototype calorimeter. The sensor’s 500 µm pixel pitch enabled precise measurement of the beam profile, providing important information for the calorimeter performance studies. Using the measured 120 GeV proton data, we measure the energy deposit of minimum ionizing particles (MIP) and use them to extract the corresponding effective depletion depth at a single bias voltage of −150 V .

AstroPix↗

Investigation of the excited states of 114 Sn using the GRIFFIN spectrometer at TRIUMF

The semi-magic 110-122 Sn isotopes display signs of shape coexistence in their excited 0 + states, which, in contrast to the spherical 0+ ground states, are deformed. Here, this paper investigates the nuclear structure of 114 Sn using the competing β + decay and electron capture of a radioactive beam of 114 Sb produced at the TRIUMF-ISAC facility using the GRIFFIN spectrometer. This study will allow for an in-depth understanding of the excited 0 + states in 114 Sn, by focusing on their decay patterns. In the present experiment, transitions at 856.2-keV and 1405.0-keV, which were observed in an earlier β + decay study but not placed in the 114 Sn level scheme, have been Physics, assigned to the level scheme in connection to the 0$^+_3$ level at 2156.0-keV. Properly assigning these transitions refines the level scheme and enhances our understanding of the nuclear structure in 114 Sn.

GRIFFIN↗

Neutron capture measurements at UMass lowell research reactor

A new facility was designed around the thermal column beam port of the 1 MW Research Reactor at the University of Massachusetts Lowell. Thermal neutrons are collimated to a 1-inch diameter beam and incident on samples to induce the radiative neutron capture. New measurements of capture gamma rays are planned for Mn, Cu, Ni, Cr, and Gd samples in the next few years. The experiments will be carried out in close collaboration with the ENSDF (Evaluated Nuclear Structure Data File) evaluation group at Brookhaven National Laboratory. The gamma rays are measured using an array of high-resolution HPGe detectors. Some of the HPGe detectors use active Compton shields that were designed from scintillation detectors and improve significantly the signal-to-background in the measured gamma-ray spectra with HPGe. The experimental spectra will be validated by the GEANT4 simulations of the array and theoretical models of the emission of gamma rays from the compound nucleus. In conclusion, the new experimental results on the capture gamma ray intensities will be incorporated in future ENSDF evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

59 Co(p,X) spallation reaction cross sections for 250 MeV to 2 GeV protons

Cobalt is an advantageous target for probing the physics of nuclear spallation, because it is a naturally mono-isotopic element ( 59 Co), and its per-nucleon binding energy (BE/A = 8.768 MeV) is near the maximum value for all nuclei. We measured nuclear spallation cross sections for the 59 Co(p,X) reaction at five kinetic energies ranging from 250 MeV to 2 GeV. Cross sections for the production of 58 Co, 57 Co, 57 Mn, 56 Co, 56 Mn, 56 Cr, 55 Fe, 53 Fe, 54 Mn, 52 Mn, 51 Cr, 49 Cr, 48 V, 47 Sc, 46 Sc, 44 Sc, and 44 Scm are reported. Where comparable data exist in the EXFOR reaction database, we find that our measured cross sections generally agree. In many cases, we provide data for reactions or energies not currently reported in EXFOR. Our cross sections also provide evidence for the presence of α-clusters within the 59 Co nucleus, a surprising result given the asymmetry in Z (27) and N (32) for this nucleus. Finally, we use our measurements to evaluate the accuracy of spallation cross section simulations from GEANT4-based radiation transport toolkit, performed with the INCLXX-, Bertini-, and Binary-ion-cascade (BIC) based physics lists. This benchmarking activity revealed that the simulations overestimated the cross sections by a factor of ∼2–4 on average, and that the INCL-XX physics list provides the most reliable results. This evaluation informs the selection of the GEANT4 physics lists used for the analysis of data from NASA’s Psyche mission, which will measure γ rays and neutrons resulting from spallation reactions occurring on the surface of an asteroid whose surface is thought to be rich in iron-nickel metal.

43 PARTICLE ACCELERATORS↗