Search NASA⌕ Search

SEARCH · Search NASA

Results for “gas compression engine”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Characterization of SiO 2 Thermally Grown Oxide Stress Evolution of EBCs with Al-Containing Dopants

SiC/SiC ceramic matrix composites (CMCs) are desired for use in combustion environments to achieve higher turbine operating temperatures. However, CMCs require environmental barrier coatings (EBCs) for protection from the gas environment. EBC systems are known to primarily fail through coating delamination via growth of a thermally grown oxide (TGO) at the EBC—silicon bond coating interface when exposed to steam, which accelerates the TGO growth rate. The TGO undergoes a phase transformation during thermal cycling, which results in stresses that may encourage EBC spallation. Yb-silicate EBCs with mullite and yttrium aluminum garnet (YAG) dopant additions were deposited on SiC substrates with a Si intermediate bond coating and exposed to thermal cycling in steam at 1350 °C. The impact of Al dopant additions on the TGO growth rate and the SiO 2 phase transformation was assessed. Photo-stimulated luminescence spectroscopy (PSLS) was used to characterize the Al-containing phases and to measure stress evolution in the EBC following exposure using the stress-induced peak shift of the R-lines of mullite. Raman microscopy was used to map the stresses in the Si bond coating following exposure. It was found that the TGO phase transformation upon cooling increased compressive stress in the Si bond coating within 15 µm of the TGO.

Building Materials↗

Effects of multiple simultaneous faults on characteristic fault detection features of a heat pump in cooling mode

Faults in air-cooled vapor compression air-conditioning systems are known to reduce performance, including efficiency, capacity, and lifespan. Their effects have been studied, and fault detection and diagnostic (FDD) methods have been developed as tools for field technicians to install or repair systems, or for monitoring to alert operators to the fault’s presence. Most of this work has focused on faults that occur singly. It is likely that in some systems, multiple faults occur simultaneously, but it is uncertain what effects this may have on diagnostics. Here, this paper describes a laboratory study of a split system air source heat pump in which combinations of two, three, and four simultaneous faults occur. The study includes all combinations of: improper evaporator airflow; overcharge or undercharge of refrigerant; liquid line restrictions; and non-condensable gas in the refrigerant, each at multiple fault intensities. Fault features – those characteristics that can be determined from measurements, for use in diagnostics – are analyzed, and the key fault features are presented. A robust existing method for determining refrigerant charge, the virtual refrigerant charge sensor (VRC) is tested using the multiple fault data, in order to understand how its performance is impacted by the combined faults. The VRC performs well, typically able to correctly determine whether a system is undercharged or overcharged, but the magnitude estimates are impacted. The results suggest that simple subcooling-based methods of charging a system are likely to provide unsatisfactory results when other faults are present.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Effects of stereoisomeric structure and bond location on the ignition and reaction pathways of hexenes

The current work presents new experimental autoignition and speciation data on the two cis-hexene isomers: cis-2-hexene and cis-3-hexene. The new data provide insights on the effects of carbon-carbon double bond location and stereoisomeric structures on ignition delay times and reaction pathways for linear hexene isomers. Experiments were performed using the University of Michigan rapid compression facility to determine ignition delay times from pressure-time histories. Stoichiometric (Φ = 1.0) mixtures at dilution levels of inert gas to O 2 = 7.5:1 (mole basis) were investigated at an average pressure of 11 atm and temperatures from 809 to 1052 K. Speciation experiments were conducted at T = 900 K for the two cis-hexene isomers, where fast-gas sampling and gas chromatography were used to identify and quantify the two cis-hexene isomers and stable intermediate species. The ignition delay time data showed negligible sensitivity to the location of the carbon-carbon double bond and the stereoisomeric structure (cis-trans), and the species data showed no correlation with the stereoisomeric structure, but there was a strong correlation of some of the measured species with the location of the double bond in the hexene isomer. In particular, 2-hexene showed strong selectivity to propene, acetaldehyde, and 1,3-butadiene, and 3-hexene showed selectivity to propanal. Model predictions of ignition delay times were in excellent agreement with the experimental data. Furthermore, there was generally good agreement for the model predictions of the species data for 2-hexene; however, the mechanism overpredicted some of the small aldehyde (C 2 -C 4 ) species for 3-hexene. Reaction pathway analysis indicates the hexenes are almost exclusively consumed by H-atom abstraction reactions at the conditions studied (P = 11 atm, T > 900 K), and not by C 3 -C 4 scission as observed in high-temperature (>1300 K) hexene ignition studies. Improved estimates for 3-hexene + OH reactions may improve model predictions for the species measured in this work.

42 ENGINEERING↗

Hydrodynamic instabilities and heat transfer characteristics in the duct flow of a fluid in the supercritical thermodynamic regime

The behavior of fluids at supercritical thermodynamic conditions is inherently complex due to large variations in thermodynamic and transport properties. Recent numerical and experimental investigations illustrate ongoing interest for these fluids, especially supercritical CO 2 and supercritical water, for a variety of applications. For example, supercritical water reactors (SCWR) operate in this extreme condition of high-pressure and temperature, resulting in highly dynamic flow fields and unexpected heat transfer regimes. The potential heat transfer benefits in this regime are directly associated with the extreme variations in thermodynamic and transport properties, which occur at, and above, the critical point. This work characterizes the hydrodynamic instabilities that arise for fluids at supercritical thermodynamic conditions when buoyancy forces are significant. Two specific configurations are considered, a natural convection cavity flow, and a mixed convection, heated, horizontal channel flow. Natural convection flow in a cavity is a classical configuration with expected behavior below the critical point. This configuration aids in characterizing the effect of the variable properties in the supercritical thermodynamic regime. Further, limited studies in the existing literature have been conducted for low-Reynolds and intermediate-Rayleigh numbers, mixed-convection channel flows for supercritical water, which is the focus of the channel flow configuration. To investigate the thermally driven hydrodynamic instabilities in this regime, a high-order fully-implicit numerical method is used. Such strong variations in thermophysical properties (in particular, density) are difficult to simulate and an altogether compressible framework is needed. Therefore, the compressible Navier-Stokes equations are solved without any additional assumptions. The fully implicit, high-order in space and time, reconstructed discontinuous Galerkin method as implemented within the multi-physics code called ALE3D (Arbitrary Lagrangian and Eulerian in 2D and 3D), developed at Lawrence Livermore National Laboratory (LLNL), is used. This fully implicit, L-stable method accurately captures the compressible nature of the ow in the limit of very low Mach number. It has been widely accepted that above the critical point, only one phase is observed. However, recent research has indicated the existence of the distinct gas-like and liquid-like regions separated by the Widom line, the locus of the maxima of the specific heat. Along the Widom line, density decreases 6-fold, viscosity drops by a factor of 2, while specific heat spikes by an order of magnitude. These variations, specifically in density and viscosity, produce a thick pseudo-interface and flow dynamics behavior akin to film boiling. A pseudo-film at the heated wall of the cavity and the horizontal channel is observed where buoyancy forces induce mixing through the specific configurations. Further the local Rayleigh and Richardson numbers provide maps of the flow field and the buoyancy forces driving the microscopic mixing. In the first chapter, I describe a background of supercritical fluid and the various applications. The second chapter focuses on the mathematical model and numerical method used for simulations, where a description of the equation of state for supercritical water is described. The third chapter focuses on the natural convection cavity with a heated bottom wall. In this cavity a gas-like and a liquid-like flow within the supercritical thermodynamic regime are observed. The fourth chapter focuses on a forced convection, horizontal channel, distinguishing between the gas-like, liquid-like, and mixed flow regimes. Mixed convection flow, with the addition of gravitational forces in the horizontal channel show the influence of variable properties on the hydrodynamic development, heat transfer, and rising instabilities. The last chapter of this research focuses on characterizing the unstable hydrodynamics through time-averaging processes and analysis of the movement of energy through the developing plumes.

42 ENGINEERING↗

Modeling of the effects of non-equilibrium excitation and electrode geometry on H 2 /air ignition in a nanosecond plasma discharge

In this work, we present the results of two-dimensional modeling of the effects of non-equilibrium excitation and electrode geometry on H 2 /air ignition in a nanosecond plasma discharge. A multiscale adaptive reduced chemistry solver for plasma assisted combustion (MARCS-PAC) based on PASSKEy discharge modeling package and compressible multi-component reactive flow solver ASURF+ is developed and validated. This model is applied to simulate the impact of non-equilibrium plasma excitation and electrode geometry and heat loss on the dynamics of the discharge from streamer to spark and ignition kernel development in a H 2 /air mixture with a pair of cylindrical electrodes. The results show that the plasmagenerated species (N 2 (A), N 2 (B), N 2 (a'), N 2 (C), O( 1 D), O and H) in the spark and afterglow significantly accelerate the ignition kernel development. The increase of discharge voltage at the same total discharge energy promotes the non-equilibrium active species production. It is found that the production of electronically excited species at higher reduced electric field strength is more efficient in enhancing ignition in comparison to the vibrational excitation and heating. Moreover, the 2D simulation clearly reveals that the electric field and active species distribution are highly non-uniform. The streamers are initiated at the sharp outer edges of the negative and positive electrodes by a strong electric field while the electric field is much weaker at the centerline of the electrodes. Furthermore, the simulations reveal that the ignition enhancement is sensitive to the variation of electrode shape, diameter, and gap size due to the changes of electric field distribution and location of streamer formation. A cylindrical electrode produces a larger discharge volume and ignition kernel than the parabolic and spherical electrodes, when the discharge is localized near the axis of the gap. It is found that there is a non-monotonic dependence of ignition kernel size on the electrode diameter and inter-electrode distance. The increase of electrode diameter and gap size above the optimal conditions leads to the reduction of ignition kernel volume, due to the decrease of active species concentration and gas temperature. At a larger electrode surface area and electrode diameter as well as smaller electrode gap size, the heat loss to electrode plays a greater role in reducing the ignition kernel size and slowing ignition kernel development. This work provides insights and guidance to understand the kinetic enhancement of non-equilibrium plasma and the effects of electrode geometries on ignition for the optimization ignitors in advanced engines.

42 ENGINEERING↗

Experimental Study of the Effect of Start of Injection and Blend Ratio on Single Fuel Reformate RCCI

Abstract A new concept of single fuel reactivity-controlled compression ignition (RCCI) has been proposed through the catalytic partial oxidation (CPOX) reformation of diesel fuel. The reformed fuel mixture is then used as the low reactivity fuel and diesel itself is used as the high reactivity fuel. In this paper, two reformate mixtures from the reformation of diesel were selected for further analysis. Each reformate fuel mixture contained a significant fraction of inert gases (89% and 81%). The effects of the difference in the molar concentrations of the reformate mixtures were studied by experimenting with diesel as the direct injected fuel in RCCI over a varying start of injection timings and different blend ratios (i.e., the fraction of low and high reactivity fuels). The reformate mixture with the lower inert gas concentration had earlier combustion phasing and shorter combustion duration at any given diesel start of injection timing. The higher reactivity separation between reformate mixture and diesel, compared with gasoline and diesel, causes the combustion phasing of reformate-diesel RCCI to be more sensitive to the start of injection timing. The maximum combustion efficiency was found at a CA50 before top dead center (TDC), whereas the maximum thermal efficiency occurs at a CA50 after TDC. The range of energy-based blend ratios in which reformate-diesel RCCI is possible is between 25% and 45%, limited by ringing intensity (RI) at the low limit of blend ratios, and coefficient of variance (COV) of net indicated mean effective pressure (IMEPn) and combustion efficiency at the high limit. Intake boosting becomes necessary due to the oxygen deficiency caused by the low energy density of the reformate mixtures as it displaces intake air.

Engineering↗

Analytical Modeling of Biomass Transport and Feeding Systems

The processing of biomass solids in a biorefinery consists of pretreatment, enzyme hydrolysis / concurrent fermentation of sugars to ethanol, product recovery, and drying. Sustainable operation requires a front end that transforms wet solids into a pumpable slurry. Otherwise the biorefinery will suffer unscheduled shut-downs and inefficient operation due to solids that obstruct pumps and other equipment and resist mixing in a bioreactor. Downtime in pioneer biorefineries due to interruptions from materials handling problems has been 50% or more, leading to unsustainable manufacturing processes. This work addresses new technology, predictive computational models, and definition of operational conditions that result in formation of slurries of corn stover at up to 300 g/L using low enzyme loadings (1 to 3 FPU cellulase/g) before the biomass (corn stover) enters the pretreatment step. A team of researchers from Purdue University, Idaho National Laboratory (INL), Forest Concepts, AdvanceBio, Argonne National Laboratory, and DOE BETO have combined their knowledge in agricultural and biological engineering, bioprocess engineering, mechanical engineering, chemical engineering, agricultural economics, materials engineering and enzyme and microbial technology to address the challenge of making lignocellulose flow. This team effort has resulted in the development and validation of conditions that employ low levels of commercial enzyme in an agitated bioreactor to which corn stover pellets are added resulting in formation of slurries at high solids loadings, before pretreatment. This approach overcomes challenges caused by handling of dry, particulate biomass materials at the front end of the biorefinery. The subsequent materials handling issues cause obstruction at pumps, pipes and valves. Formation of high loadings slurries with low yield stress, as reported here, significantly decreases the potential for process interruption and enhances plant operability. Key advances in the knowledge of how slurry formation occurs is reported here and in recently published journal papers. We found that pellets are needed to achieve high solids loading, and that commercial enzymes are effective in forming slurries of corn stover particles from pellets that have not been pretreated. Our work has resulted in models that predict solids behavior for formation of compressed solids and pellets that in turn facilitate slurries made of high concentrations of corn stover particles. A computational model was developed that gives mechanistic insights into properties of particles and mixing process that gives the slurry rheology needed to facilitate pumping. Hence, the corn stover may be pumped into a pretreatment reactor in place of auguring in solids against high pressure which is a root cause of interruptions at the front end of a biorefinery. Subsequent mixing in enzyme and microbial bioreactors results in conversion of lignocellulose to sugars in a biorefinery in agitated bioreactors, with flows in and out of the vessels being less likely to be interrupted due to plugging or materials handling problems. The obtained data coupled to process models, techno-economic assessment (TEA) and Life Cycle Analysis (LCA) were used to assess whether this approach is practical. These results are based on a foundation of laboratory characterization and pilot runs. The NREL biochemical sugar model was utilized to carry out techno-economic analysis of enzyme catalyzed liquefaction followed by enzyme hydrolysis. The minimum sugar selling price was between 17.5 and 18.3 ¢/pound or about the same as calculated by the NREL model for dilute acid pretreatment followed by enzyme hydrolysis. Life cycle analysis (LCA) based on Argonne’s Greet Model showed the enzyme catalyzed route had the lowest greenhouse gas emissions of the three combinations studied (i.e., enzyme, enzyme mimetic, and enzyme + mimetic combined). GHG emissions for enzyme-based corn stover liquefaction step, alone, were about 21 g CO 2 -equivalent/kg of liquefied slurry. We believe this approach will further enhance operability of a pioneer biorefinery, and bring large-scale conversion of lignocellulosic biomass to low carbon footprint biofuels closer to implementation.

09 BIOMASS FUELS↗

Cryogenic Carbon Capture™ (CCC) Status Report

The Cryogenic Carbon Capture™ (CCC) process separates CO2 from light gases in essentially any continuous process. CCC cools the gases to the frost or desublimation point of CO2 (-100 to -135 °C), separates and pressurizes the solids, and warms all streams to produce a CO2-depleted stream at ambient pressure and a pure (99+%) pressurized liquid CO2 stream typically to about 150 bar, both at ambient temperature. The process also recovers all gas moisture and most gas impurities less volatile than CO2 (NOx, SOx, Hg, PM, UHC, CCC, etc.) in separable streams. CCC nearly eliminates refrigeration energy for sensible temperature changes through heat integration. CCC does require energy to change the CO2 phase from a mixed vapor to a pressurized fluid, which represents the minimum energy required of any process for this separation. CCC uses additional energy for turbomachinery inefficiencies, heat losses, moisture removal and overall process pressure drop. Aside from these real-world energy demands, CCC operates near the minimum energy required to perform this gas separation by minimizing stream recycling. CCC compresses CO2 as a liquid, which is one of several reasons it costs about about half as much and consumes about half as much energy as an amine process when using flue gases with about 15% CO2. The process also has several major additional advantages, including (a) it is a bolt-on retrofit technology that does not need steam or any modification of existing equipment, (b) it recovers water and nearly all pollutants in addition to CO2 from the flue gas, (c) it enables highly efficient and cost effective energy storage at grid scale and on time scales of minutes, (d) it enables NG storage if the energy storage option is used, and (d) it has a small footprint and is minimally disruptive to existing plants, requiring only electrical power and a gas source to operate. Sustainable Energy Solutions (SES) has scaled this technology through several levels, the largest of which captures nominally 1 tonne of CO2/day and is called the skid system. Skid system field tests include utility-scale power plants, cement plants, heating plants, and other utility or industrial sites that burn natural gas, biomass, coal, shredded tires, municipal waste, and combinations of these fuels. These field tests produced 95-99% CO2 capture with CO2 purities of 99+% and initial CO2 contents that range from 4 to 28%. SES currently seeks to scale the system to merchant scale (10-80 tonnes of CO2 per day). In the process of doing so, SES has demonstrated the potential for CCC to contribute to energy storage and direct air capture in innovative and cost-effective ways. This presentation discusses the overall process and highlights results from field and in-house tests. These include (a) measured CO2 capture rates and operating conditions from in-house and field tests, and (b) predicted utility-scale costs and energy demands. This discussion also includes the application of the CCC technology to energy storage and direct air capture.

20 FOSSIL-FUELED POWER PLANTS↗

Epoxy-based vitrimeric semi-interpenetrating network/MXene nanocomposites for hydrogen gas barrier applications

Herein, we report MXene-filled epoxy-based vitrimeric nanocomposites featuring a semi-interpenetrating network (S-IPN) to develop a hydrogen gas (H 2 ) barrier coating with self-healing characteristics for compressed H 2 storage applications. The reversible epoxy network was formed by synthesizing linear epoxy chains with pendent bis-hydroxyl groups using amino diol, which were then crosslinked with 1,4-benzenediboronic acid to generate dynamic boronic ester linkages. To achieve the S-IPN-type molecular arrangement, the epoxy chains were in situ crosslinked in the presence of poly(ethylene-co-vinyl alcohol) (EVOH), giving rise to a self-healing network (EEP) with a healing efficiency of 87%. Into the S-IPN vitrimer (EEP), a 2D platelet-type nanofiller MXene was incorporated to introduce a tortuous path for H 2 gas diffusion along with improved mechanical properties. The nanocomposite coating was applied to nylon 6 liner material, which is conventionally used in all-composite H 2 storage vessels. Further, the application of a 2 wt% MXene/EEP nanocomposite coating showed a permeability coefficient of 0.062 cm 3 mm m -2 d -1 atm -1 exhibiting ~96% reduction in gas permeability compared to uncoated nylon 6. The same nanocomposite exhibited a healing efficiency of 79%. Increasing the MXene loading to 10 wt% further reduced the permeability coefficient to 0.002 cm 3 mm m -2 d -1 atm -1 ; however, the healing efficiency decreased due to restricted chain mobility. In essence, the current work highlights the potential of vitrimeric S-IPN nanocomposite coatings for H 2 gas-barrier applications, enhancing safety and performance.

42 ENGINEERING↗

RePED 250: A Revolutionary, High Drilling Rate, High-T Geothermal Drilling System and Companion Power Electronics

Geothermal drilling in the United States is drastically slower and more costly than Oil and Gas (O&G) drilling, primarily due to the additional challenges in geothermal wells: hard rock types and high temperatures. The Repetitive Pulsed Electric Drill (250°C) (RePED-250), developed by Tetra Corporation has the potential to change this with a novel electro-crushing technology. RePED-250 releases pulses of electricity through the rock, which causes it to break in tension, instead of compression like conventional rotary drilling. The tensile strength of hard rocks like granite is only ~5% of their compressive strength, requiring less energy, time, and wear on the bit compared to conventional drilling. The RePED drill bit has no moving parts, uses drilling mud to remove rock fragments, and uses standard drill pipe, enabling a direct transition from conventional drilling systems. The objective of this project is to move RePED technology towards commercial readiness for high-temperature geothermal applications. This involves: 1) Creating high-temperature, high power electronic components for the RePED drill capable of operating at the high temperatures of a geothermal well. The target is a 250°C ambient environment. Specifically, capacitors, high voltage switches, and a downhole generator capable of generating the necessary power. 2) Demonstrating RePED’s effectiveness drilling through hard rock (granite) and examining its pathway to commercialization and effect on the US geothermal market. Work on this project has led to significant improvement over the state-of-the-art for all the examined electronics, through design, modeling, and testing of these novel components, though some additional development is still needed to deploy these high-temperature parts in a geothermal well. Besides their use in RePED-250, each component has applications in other industries where the stability of electronics at high-temperature is needed. To address the second barrier to commercialization, a 9” hole was drilled through a sample block of granite, demonstrating the tool’s effectiveness in hard rock. The team investigated RePED-250’s effect on well cost and the geothermal industry, through various techno-economic models described in the report.

15 GEOTHERMAL ENERGY↗

Chemical kinetic interactions of NO with a multi-component gasoline surrogate: Experiments and modeling

Here this work reports an experimental and modeling study on the chemical kinetic interactions of NO with a multi-component gasoline surrogate, namely PACE-20, using a twin-piston rapid compression machine at a stochiometric fuel loading with 20% EGR (exhaust gas recirculation) by mass, pressures of 20 and 40 bar, and temperatures from 700 to 930 K. Five NO concentrations are investigated, namely 0, 20, 50, 70 and 150 ppm, where NO addition effects are characterized through changes in PACE-20 ignition reactivity and heat release characteristics. Experiments indicate that within the low-temperature regime, NO promotes low-temperature heat release rate and main ignition reactivity at low addition levels, with saturation or even inhibiting effects observed at >50 ppm NO addition, while within the NTC/intermediate-temperature regime, adding NO only promotes reactivity. A recently updated, detailed chemical kinetic model with chemistry specific to NOx/hydrocarbons interaction incorporated is used to simulate the experiments, and reasonable agreement is obtained. In-depth sensitivity and rate of production analyses are further performed. The results indicate that NO interacts with PACE-20 via two types of interaction: (a) direct interactions between NO and PACE-20 derivatives, primarily through NO+HO 2 ↔NO 2 +OH and RO 2 +NO↔RO+NO 2 , and (b) indirect interactions between PACE-20 derivatives and NO 2 produced from the direct interactions, primarily through R+NO 2 ↔RO+NO. The observed NO inhibiting effect at low temperatures and 150 ppm NO addition is attributed to the lack of HO 2 radicals to sustain NO consumption via NO+HO 2 ↔NO 2 +OH, and the take-up of inhibiting pathways via RO 2 +NO↔RO+NO 2 . The results also indicate that even with the presence of multiple fuel components, NOx/hydrocarbons interactions are highly selective, and are mainly initiated by the interactions between NO and RO 2 radicals from cyclopentane and ethanol, as well as between NO 2 and R radicals from toluene, 1,2,4-trimethylbenzene and 1-hexene. Further studies on these interactive reactions are therefore highly recommended.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unraveling the role of EGR olefins at advanced combustion conditions in the presence of nitric oxide: Ethylene, propene and isobutene

We report the role of EGR (exhaust gas recirculation) olefinic constituents at advanced combustion conditions in the presence of nitric oxide is unraveled in this study through experimental and modeling efforts using a twin-piston rapid compression machine operating at a stochiometric fuel loading with 20% EGR by mass, pressures of 20 and 40 bar, and temperatures from 680 to 950 K. Five different levels of olefin addition, focusing on ethylene, propene and isobutene, with a fixed amount of NO at 70 ppm are doped into test mixtures of PACE-20, a multi-component gasoline surrogate, where olefin addition effects are characterized through changes in ignition times and heat release rates. Experiments indicate that all three EGR olefins inhibit autoignition reactivity and low-temperature heat release at Tc < 850 K, with isobutene exhibiting the greatest impact, while at Tc > 850 K, low ethylene and propene additions promote reactivity. A recently updated chemical kinetic model, with detailed gasoline/NO x interacting and olefin/NO x interacting chemistry incorporated, is adopted to simulate the experiments. Simulation results are somewhat inconsistent with the experiments, where the model captures the inhibiting effects of all olefins on first-stage ignition reactivity, while consistently predicting a promoting effect on main ignition reactivity. Sensitivity and rate of production analyses reveal that adding olefins greatly alters the role of the consuming pathways for the olefins and their primary derivatives at the initial stage of the oxidation process, particularly with the presence of NO, where the olefins and their derivatives interact with both NO x species such as NO 2 and other species such as OH and HO 2 . The olefin/NO x interactions are particularly pronounced with propene and isobutene addition, where these lead to increased ignition reactivity by facilitating NO production and are mostly responsible for the disagreement between the model and experiments. Further investigations of olefin interacting chemistry, particularly those with NOx species, are needed for chemistry models to accurately predict the complicated effects of EGR.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Methane Mitigation Thermoelectric Generator (MMTEG) (Final Scientific/ Technical Report)

Gas Technology Institute (GTI) has completed a $1.815M (plus $500K cost share), 54-month Co-operative agreement with the Department of Energy’s National Energy Technology Laboratory to develop a Methane Mitigation Thermoelectric Generator (MMTEG) system for gas field applications. This novel system uses fugitive gas to produce electrical power and consists of Thermoelectric Generators (TEG) driven by a linear burner, an air compressor, an accumulator, valves, batteries, and power electronics. The electrical power generated by the system is used to compress air and, in turn, the air is used to operate the pneumatic valves at the well site instead of using natural gas (NG) which would then be vented. The team completed the project objectives which included (1) Design, fabricate and test an integrated 6We nominal MMTEG prototype system, (2) Design a “retrofit kit” MMTEG system capable of being field tested at a gas well production site, and (3) build and test the field MMTEG system in a laboratory environment. Multiple system options were developed prior to selecting a “Passive” system which meets cost, NG savings, and greenhouse gas (GHG) reduction targets although not as efficient as initially planned. The MMTEG system is built primarily from commercial off-the-shelf parts (in some cases re-purposed) including the heat exchanger, heat rejection, electronic components, and also the TEGs. The team developed and implemented a novel system including the control system developed by Morrison Applied Sciences (MAS). The team completed incremental demonstrations of the hardware prior to the MMTEG system demonstration. A one-year simulation of the air delivery and battery charging subsystems was completed prior to the integration into the MMTEG system. In addition, the team simulated two-years of thermal cycles for integrated Burner/TEG/heat rejection subsystem. Finally, the entire MMTEG system was assembled, and troubleshooting was completed over a two-week period. Next, the MMTEG system was tested to simulate over 15 weeks of entire system operation over approximately four weeks in an accelerated test fashion with minimal intervention (such as changing fuel tanks). The MMTEG system met the key goals of a unit cost of under $1500 while saving 97% of NG expended today (including leakage) on average by pneumatic systems venting to the atmosphere. The MMTEG system reduced GHG emissions by 1000X (using the methane intensification factor of 28 relative to CO2). GTI is currently pursuing a field test of the MMTEG system. Interfacing with producers has provided additional insight into system improvements. Planned improvements include additional weather protection and control system improvements including the implementation of a long- range radio capability to notify operators if there is a fault.

03 NATURAL GAS↗

Density variance dynamics in disparate shock tubes

This report discusses two experiments which investigate thin layer, heavy curtain fragmentation from the perspective of a Reynolds-Averaged mix model, in drastically disparate experimental regimes. The first, the centimeter/millisecond-scale “Horizontal Shock Tube” (HST) is a compressed-gas piston-driven shock tube experiment. The second, the “Multishock thin layer” (Mshock) experiment performed at the National Ignition Facility, is a micrometer/nanosecond-scale laser-driven shock tube experiment. Both are situations in which a heavy plane layer (a ‘curtain’) is initially suspended in a lighter medium. After being shocked from at least one side, the layer translates while its interfaces evolve due to the excitation of the Richtmyer-Meshkov instability at its surfaces. The evolution of density variance, which initially exists only on the surface of the layer, as it comes to encompass the whole layer interior is used as a description of layer fragmentation and dissolution. These experiments have each been simulated in the Los Alamos National Laboratory multi-physics code xRAGE, which includes fundamental hydrodynamics, extended plasma physics and radiation effects which are important to drive the high-energy density experiment, and the Besnard-Harlow-Rauenzahn (BHR) turbulence model. In each, the principal diagnostic for comparison is an experimental metric for the density (co)variance, b, which tracks the moments of the density field at the curtain interfaces and body. Due to experimental constraints in different regimes (i.e. optical diagnostics can be deployed on conventional shock tubes, while the plasma shock tubes must be imaged by x-rays; interfaces can be imposed to specification on laser-driven experiments, which are stored in the solid phase, while conventional experiments have imperfect control of the flow fields which separate the layer, etc.) the experiments are not designed to be perfect scaled cognates of one another. However, despite the separation of six orders of magnitude of scaling in time, and four in space, we are able to demonstrate that the same turbulence model, operating in the same fashion in the same computer code, is able to reproduce results in each experiment, by tracking evolution due to common relevant physics. Additionally, we will present preliminary work toward density variance comparisons in a single-interface Richtmyer-Meshkov configuration, the conventional fluid “Vertical Shock Tube” (VST) experiment, and the Modal Initial Conditions (ModCons) campaign fielded at the OMEGA-EP laser facility.

42 ENGINEERING↗

Cost-Optimized Cold Climate Heat Pump Development and Field Test

Cold climate heat pumps (CCHPs) expand the heat pump market to climates where heating demand is dominant. They can achieve more than 70% energy savings compared with electric resistance heating and operate at lower cost than using tank-stored propane to fuel a furnace. A high-efficiency heat pump with a heating seasonal performance factor (HSPF)—as defined by the Air-Conditioning, Heating, and Refrigeration Institute (AHRI 2008)—greater than 10.0 would be more efficient than gas heating in terms of source energy. However, developing a cost-effective CCHP involves some challenges. A typical single-speed, air-source heat pump (ASHP) with an HSPF of 7.7 Btu/Wh does not work well under cold outdoor temperature conditions typical of cold climate locations for four major reasons: 1. Discharge temperature is too high—The low suction pressure and high compression pressure ratio at low ambient temperatures causes high compressor discharge temperatures in excess of the maximum limit for many of the compressors on the market. Furthermore, system charge of a heat pump is usually optimized in the cooling mode, which leads to overcharge conditions in the heating mode, further increasing the discharge temperature. 2. Heating capacity is insufficient if sized to meet the building design cooling load— Heating capacity of a single-speed heat pump decreases with ambient temperature. The heating capacity at -13°F (-25°C) typically decreases to 20%–40% of the rated heating capacity at 47°F (8.3°C) (~equivalent to the rated cooling capacity at 95°F [35°C]). Therefore, a single-speed heat pump, typically sized to match the building design cooling load, cannot provide adequate heating capacity to match the building heating load at low ambient temperatures. The capacity deficit is filled by inefficient resistance heat, thus lowering the system efficiency and significantly increasing power demand. 3. Cyclic loss is significant if sized to meet the building design heating load—If a single-speed heat pump is sized to meet the heating load, it will be significantly oversized relative to the cooling load in many cold climates. This will cause excessive on/off cyclic loss during the cooling and heating operations at moderately low ambient temperatures. Thus, capacity modulation capability (e.g., using a variable-speed or multi-stage compressor) is necessary for a CCHP, which uses its full capacity to meet the peak heating load and partial capacity to meet the cooling and part-load heating loads. 4. Coefficient of performance (COP) is low—Heating COP degrades significantly at low ambient temperatures owing to the large temperature difference between the heat source and sink. A target CCHP should be sized to meet the building design heating load while minimizing the cyclic loss for the cooling and heating operations at moderate ambient temperatures.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cryogenic Carbon Capture™ Technoeconomic Analysis

The Cryogenic Carbon Capture™ (CCC) process significantly decreases cost and energy demands for CO 2 separation and pressurization to 150 bar compared to alternatives. The process is a post-combustion technology that cools CO 2 -laden flue gas to desublimation temperatures (-100 to -135 °C), separates solid CO 2 —that forms from the flue gas—from the light gases, uses the cold products to cool incoming gases in a recuperative heat exchanger, compresses the solid/liquid CO 2 to final pressures (100–200 bar), and delivers a compressed CO 2 stream separated from an atmospheric pressure light-gas stream. The overall energy and economic costs are about 30-50% lower than most competing processes that involve air separation units (ASUs), solvents, or similar technologies. In addition, the CCC process enjoys several ancillary benefits, including (a) it is a minimally invasive Bolton technology, (b) it provides highly efficient removal of most pollutants (Hg, SOx, NO 2 , HCl, etc.), and (c) possible energy storage capacity. This report outlines the process details and economic and energy comparisons relative to other well-documented alternatives. This paper presents the results of a detailed techno-economic comparison of CCC with amine-based systems. The comparison uses identical financial and economic assumptions similar process assumptions as the detailed analyses published by US DOE in the greenfield analysis. Specifically, the comparison assumes power plants that produce the same net output, one equipped with and a second without carbon capture. Separately, the paper compares similar analyses for retrofitting existing systems using typical plant characteristics in the US (initial capital costs have been paid, high plant utilization), though there are no DOE estimates available for direct comparison. Financial and technical assumptions for all comparisons are maintained as close to the DOE reference studies as possible. The results demonstrate about 30-50% lower costs and energy demands for capture from greenfield coal plants. Natural gas plants produce substantially lower CO 2 concentrations which makes the cost of capturing a ton of CO 2 at the same capture rate as the coal plant higher for all processes while the cost of CO 2 capture per unit of power generation is lower. However, CCC maintains about the same absolute energy and cost advantages for NG as for coal compared to amine systems. Finally, the costs of retrofitting a station are compared to those of building a new station with and without capture. The retrofit costs are comparable to (slightly lower than) new plant costs without capture. In all cases operating and capital cost comparisons show that the CCC process can be retrofitted to a variety of plants to cost effectively reduce CO 2 emissions. Further process integration into the upstream processes and unique process features like water recovery, and integrated energy storage bring the effective cost of carbon capture using the CCC process down further and increase its advantages over alternatives. This technoeconomic analysis shows that the CCC process has the potential to the be lowest cost carbon capture technology under development today.

20 FOSSIL-FUELED POWER PLANTS↗

Recent Cryogenic Carbon Capture™ Field Test Results

Sustainable Energy Solutions (SES) has been developing Cryogenic Carbon Capture™ (CCC) since 2008. In that time, two processes have been developed, the External Cooling Loop and Compressed Flue Gas CCC processes (CCC-ECL and CCC-CFG, respectively). The CCC-ECL process cools the flue gas with an external refrigerant loop. This process currently captures up to 1 tonne of CO2 per day (TPD). SES has tested CCC-ECL on real flue gas slip streams from subbituminous coal, bituminous coal, biomass, natural gas, shredded tires, and municipal waste fuels at field sites that include utility power stations, heating plants, cement kilns, and pilot-scale research reactors. The CO2 concentrations from these tests ranged from 5 to 22% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2 and PMxx at 95+%. NO was also captured at a modest rate. The CCC-CFG process has been scaled up to a 0.25 ton per day system. This system has been tested on real flue gas streams including subbituminous coal, bituminous coal, and natural gas at field sites that include utility power stations, heating plants, and pilot-scale research reactors. CO2 concentrations for these tests ranged from 5 to 15% on a dry basis. CO2 capture ranged from 95-99+% during these tests. Several other condensable species were also captured including NO2, SO2, and PMxx at 95+%. NO was also captured at 90+%. Hg capture was also verified and the resulting effluent from CCC-CFG was below a 1ppt concentration. This paper will focus on discussion of the capabilities of CCC generally, the results of CCC-ECL field testing, and future steps surrounding the development of this technology. Test results that will be presented have been collected during 9 months of testing at a commercial power plant under funding from the US Department of Energy (DOE) and the host utility. Testing of one of the systems at a commercial cement plant in the United States will also be discussed. During this testing, the system captured CO2 from the cement plant and stored the CO2 in pressurized tanks. These tanks were provided to a partner company that later used the CO2 in a CO2 utilization demonstration. The CO2 was utilized to cure concrete manufactured using cement from the same plant where the CO2 was captured. This integrated capture and utilization demonstration was the first time that the cement industry has shown in the field that it can sequester its CO2 emissions in its main product stream. This represents a potential game changing solution for industrial CO2 emissions. Operational data and host-site feedback indicate that the CCC process is ideally suited for deployment into a variety of commercial environments. A few areas of de-risking remain to make sure the technology can meet very strict industrial reliability standards. These areas of de-risking are identified and discussed. The product CO2 is shown to meet specification for many uses including industrial and merchant applications. The technology is nearing readiness for deployment at commercial scale and several initial target markets have been identified.

20 FOSSIL-FUELED POWER PLANTS↗

Emissions mitigation technology for advanced water-lean solvent-based CO 2 capture processes

This technical final report submitted to DOE/NETL presents all the research activities performed during the entirety of DE-FE0031660 project-Emissions Mitigation Technology for Advanced Water-Lean Solvent-Based CO 2 Capture Processes which spans from October 2018 through March 2022. RTI International has been conducting studies from fundamental and operational aspects to reduce the overall amine emissions from the advanced Water-Lean Solvent (WLS) systems, specifically RTI’s Non-Aqueous Solvent (NAS). This technical final report will highlight the key findings from project which align closely to the project objectives which are: Identify the contribution of vapor loss, entrainment, and aerosols to the overall emissions of water-lean systems; Determine the significance of CO 2 capture system operating parameters to the amine emissions; Develop an emissions model based on critical operating parameters; Evaluate the effectiveness of emissions mitigation devices to reduce the amine emissions to <1 ppm under flue coal-fired flue gas; and, Determine the contribution of the ECTs to the overall CO 2 capture cost. The following are the key findings based on numerous tests using both lab-scale setups and parametric testing performed at RTI’s Bench-scale Gas Absorption System (BsGAS). During the BP1, the aerosol generation system and monitoring equipment were installed at BsGAS to produce and determine the aerosol characteristics during the NAS CO 2 capture process. The aerosol produced by this setup produced aerosols with the peak diameter and concentration of 50 micron and 1.2E10 7 cm -3 , respectively. These particle sizes and concentrations are matched to those observed in the actual coal-fired power plant flue gases and expected to be found at the absorber inlet of the CO 2 capture system. Over 1,300 hours of parametric testing have been conducted to evaluate the impact of the aerosols and operating conditions during the CO 2 capture with NAS on the overall amine emissions in the treated flue gas. At the worse condition tested, the presence of the aerosols in the flue gas could increase the overall emissions by 10X compared to the baseline emissions from NAS’s vapor pressure. CO 2 capture rate was found to be a main factor impacting the overall emissions as well as aerosol size and concentrations in the absorber off-gas. The higher CO 2 capture rate, the higher amine emissions in the treated gas. The temperature difference between the temperature bulge seen in the absorber and the water wash temperature also impacts the particle growth where the larger the temperature difference, the more amine emissions from aerosols in the treated gas. The majority of the aerosols did not grow substantially in the system, and the particle concentrations remained nearly constant between the absorber inlet and wash outlet. Only a small portion of the particles were found to grow significantly. The high efficiency demister with mesh size of 5-10 micron can be installed to remove a portion of the aerosols from the gas stream leaving the water wash. Overall, these results from parametric testing have established the emission baseline and validate our assumption on the need of emission control technologies (ECT) in order to minimize the emissions from the baseline NAS CO 2 capture process. Over 2,000 of BsGAS operating hours was used to investigate a handful of process improvements which led to a selection of the vital few changes that effectively control the amine emissions. These process improvements are lime-coated-filters for absorber gas inlet, advanced demister at the top of the absorber, a second water wash with amine recovery unit were designed, installed, and tested at BsGAS at the end of BP1. The result showed that the NAS CO 2 capture process with these additional emission control devices could lower the amine emission in the treated gas to about 1 ppm using a simulated coal-fire flue gas stream. The main contributor in lowering the amine emission came from the second water wash with amine recovery unit where the amine concentration in the scrubbing water was kept below 2 wt% through a continuous amine removal via an adsorbent bed, resulting in a low amine vapor pressure. The adsorbent bed was regenerated via a direct steam regeneration and the recover amine was returned to the absorber to minimize wastewater and makeup amine. A flue gas generation system was designed and installed during the first half of BP2 to support the emission testing using a real coal-derived flue gas. The system is capable of generating both coal- and natural gas- derived flue gases with the composition of the gaseous species highly resemble to that of the power plant flue gases. The particulates detected in the coal-derived flue gas showed the mean diameter of 1 micron. The CO 2 capture operating was then proceed using the real coal-derived flue gas where the amine emission was controlled to be about 0-3 ppm for the total run time of about 200 hours. Similar testing was conducted with natural gas-derived flue gas and the result showed a highly amine emission of 30 ppm under the total run time of 200 hours. The Principal Component Analysis (PCA) and the Partial Least Squares Projection to Latent Structures (PLS) techniques were applied to the parametric testing data to derive a multivariate statistical model. The model was validated and trained with half of the data collected, and the predictive ability of the model was evaluated using the remaining half of the data. The resulting empirical model was capable of predicting the overall emissions from the NAS process without the ECTs with ±15% accuracy (average absolute deviation, AAD) in BP1. As more emission data were obtained under the real coal-flue gas in the BP2, the model incorporated these new set of data to reflect the final process configuration, operating parameters, and amine emission. This results in the updated empirical model predicting the amine emission from the NAS CO 2 capture process with 84% goodness-of-fit (R 2 ), 85% predictability (Q 2 ), and 15% AAD. The study evaluates the use of RTI’s Non-Aqueous Solvent technology for 90% CO 2 capture from a net 650 MWe pulverized coal power plant, downstream of the flue-gas desulfurization unit. The captured CO 2 has a purity of > 95% CO 2 , and is dried, compressed to 15.3 MPa (2,215 psia), ready for sequestration. The analysis uses Case B12B from the DOE Baseline study on Bituminous Coal, Revision 4 where the Cansolv CO 2 capture plant is replaced by the RTI CO 2 Capture plant. The CO 2 capture plant has been sized to capture >90% CO 2 from flue gas derived from a net 650 MWe supercritical pulverized coal power plant. The CO 2 capture plant is equipped with emission control technologies that limits the amine emissions to < 1 ppm. Two different cases were evaluated for the technoeconomic study. The key difference between the two cases is the regenerator pressure. In Case 1, the regenerator operates at 0.195 MPa (28.3 psia), whereas in Case 2, the regenerator pressure is 0.44 MPa (64 psia) thus removing the need for the first stage of compression of the eight-stage compression train. Results from the TEA are compared against the DOE reference cases for SCPC plant with and without CO 2 Capture (Case B12A and Case B12B of the DOE Baseline study, respectively). Case 2 with CO 2 regeneration at higher pressure results in the lower cost of CO 2 capture. The total capital cost of the capture process has been estimated using 2018 dollars in Aspen Process Economic Analyzer and was estimated to be $579 MM. The capture plant operation leads to a total parasitic power loss rate of 96 MWe, resulting in a decrease in pulverized coal power plant efficiency of 7.8% points. The resulting cost of electric power increases from 64.4 mills/kWh, for no capture, to 97.5 mills/kWh, with 90% capture, an increase of 51% in the COE. The cost of capturing 90% CO 2 was estimated to be $38.2/tonne-CO 2 , and meets the DOE target of $40/t-CO 2 . Emission control technologies (ECT) investigated in this project includes a second water wash with use of activated carbon beds for removal of amine from the wash water prior to recirculation in the water wash. These ECT allow operation of the CO 2 capture plant with < 1 ppm amine emissions with the treated flue gas and contributes to $2.4/t-CO 2 captured. Amine emissions derived from thermal and oxidative degradations were investigated under this project along with the emissions derived from aerosols for the NAS system. The thermally degraded of the lean NAS showed less than 4% decreased of the original total amine content in the NAS at 150 °C while the result obtained at 120 °C showed no drop in total amine content, suggesting that thermal degradation of the NAS is minimal. These results also suggested that the thermally degraded species are not likely formed and contributed to the emissions due to the low regeneration temperature of the NAS at 90-105 °C. The oxidative degradation, on the other hand, could become problematic as some of these oxidative degraded species were observed during the NAS-5 testing at National Carbon Capture Center (NCCC) and SINTEF in our previous project. The rapid screening of selected inhibitors suggested that oxidative degradation of NAS can be suppressed using thiol containing compounds in amounts of at least 1 mol%. The detailed mechanistic degradation pathway was conceived for a specific amine used in NAS formulation during BP2. he reduction of the nitrosamines caused by the NO x present in the flue gas was also examined. The study suggested that the thermo-chemical treatment of the NAS solvent would be a more effective and economically viable compared to removing NO x at the DCC.

01 COAL, LIGNITE, AND PEAT↗