Search NASA⌕ Search

SEARCH · Search NASA

Results for “high precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

High precision attitude determination for Magsat

A two phase approach to attitude determination software development is introduced. The prelaunch planning and software activities connected with the development and testing of the baseline system for processing nominal attitude data for MAGSAT are described and postlaunch analysis and modifications are outlined. Attitude data processing began 5 months after launch so that postlaunch anomalies could be accounted for. Another advantage of the two phase approach is that costs are reduced because the system is not burdened with software dealing with all possible contingencies. A definitive, continuous, time history of the three axis attitude of the spacecraft was generated to a precision of 20 arc sec (one standard deviation), in each axis. Sensor alignment determinations were done continuously because of the deletrious effects of changing alignments on attitude precision.

Abshire, G.↗

Developments in high-precision gamma-ray burst source studies

The source location data analyzed by the first and second interplanetary gamma ray burst spacecraft networks are reviewed. The possibilities of additional networks and of related studies in other disciplines, and the prospects for real time optical transient observations and for the definition of gamma ray burst sources by optical transient astronomy are also reviewed.

Cline, T. L.↗

Developments in high-precision gamma-ray burst source studies

The source location data analyzed by the first and second interplanetary gamma ray burst spacecraft networks are reviewed. The possibilities of additional networks and of related studies in other disciplines, and the prospects for real time optical transient observations and for the definition of gamma ray burst sources by optical transient astronomy are also reviewed. Previously announced in STAR as N82-31290

Cline, T. L.↗

Characteristics and capacities of the NASA Lewis Research Center high precision 6.7- by 6.7-m planar near-field scanner

A very precise 6.7- by 6.7-m planar near-field scanner has recently become operational at the NASA Lewis Research Center. The scanner acquires amplitude and phase data at discrete points over a vertical rectangular grid. During the design phase for this scanner, special emphasis was given to the dimensional stability of the structures and the ease of adjustment of the rails that determine the accuracy of the scan plane. A laser measurement system is used for rail alignment and probe positioning. This has resulted in very repeatable horizontal and vertical motion of the probe cart and hence precise positioning in the plane described by the probe tip. The resulting accuracy will support near-field measurements at 60 GHz without corrections. Subsystem design including laser, electronic and mechanical and their performance is described. Summary data are presented on the scan plane flatness and environmental temperature stability. Representative near-field data and calculated far-field test results are presented. Prospective scanner improvements to increase test capability are also discussed.

Sharp, G. R.↗

High precision active nutation control for a flexible momentum biased spacecraft

The controller design for the Solar Dynamics Observatory (SDO) is presented. SDO is a momentum biased spacecraft with three flexible appendages. Its primary scientific instrument, the solar oscillations imager (SOI), is rigidly attached to the spacecraft bus and has arc-second pointing requirements. Meeting these requirements necessitates the use of an active nutation controller (ANC) which is here mechanized with a small reaction wheel oriented along a bus transverse axis. The ANC does its job by orchestrating the transfer of angular momentum out of the bus transverse axes and into the momentum wheel. A simulation study verifies that the controller provides quick, stable, and accurate response.

Laskin, R. A.↗

High Precision Measurement of Stellar Radial Velocity Variations

A prototype instrument for measurement of stellar radial velocity variations to a precision of a few meters per second is discussed. The instrument will be used to study low amplitude stellar non-radial oscillations, to search for binary systems with large mass ratios, and ultimately to search for extrasolar planetary systems. The instrument uses a stable Fabry-Perot etalon, in reflection, to impose a set of fixed reference absorption lines on the stellar spectrum before it enters the coude spectrograph of the McDonald Observatory 2.7-m telescope. The spectrum is recorded on the Octicon detector, which consists of eight Reticon arrays placed end to end. Radial velocity variations of the star are detected by measuring the shift of the stellar lines with respect the artificial Fabry-Perot lines, and correcting for the known motions in the solar system.

Cochran, W. D.↗

GPS navigation experiment using high precision GPS timing receivers

Global Positioning System (GPS) Time Transfer receivers were developed by the Naval Research Laboratory (NRL) to provide synchronization for the NASA Global Laser Tracking Network (GLTN). The capabilities of the receiver are being expanded mainly through software modification to: Demonstrate the position location capabilities of a single channel receiver unsign the GPS C/A code; and Demonstrate the time/navigation capability of the receiver onboard a moving platform, by sequential tracking of GPS satellites.

Buisson, J. A.↗

High precision GPS orbit determination using March 1985 demonstration data

Preliminary orbit determination for satellites in the U.S. Department of Defense's Global Positioning System has been performed using GPS carrier phase data collected in March-April 1985 at 10 sites in the continental United States. The data were analyzed using a new data processing software package called GIPSY (GPS Inferred Positioning SYstem) and with existing covariance analysis software. Data from one day have been processed with average formal position errors of 1.4 to 3.6 meters. The true errors are probably somewhat larger. Covariance results are presented which suggest that the orbits can be obtained with formal errors under 2 meters after certain software issues are resolved.

Bertiger, W.↗

Method of high-precision microsampled blood and plasma mass densitometry

The reliability of the mechanical oscillator technique for blood and plasma density measurements on samples of volumes less than 0.1 ml is examined, and a precision of 0.001 g/l is found if plasma-isodensic heparin solution and siliconized densitometers are employed. Sources of measurement errors in the density determinations include storage of plasma samples, inhomogeneity of blood samples, and density reading before adequate temperature equilibration. In tests of plasma sample storage, the best reproducibility was obtained with samples kept at 4 C. Linear correlations were found between plasma density and plasma protein concentration, blood density and blood hemoglobin concentration, and erythrocyte density and MCHC.

Hinghofer-Szalkay, H.↗

High precision low resolution spectrophotometry of Comets Giacobini-Zinner and Halley

Optical window (300 to 1000 nm) observations were made of Comet Halley during 12 to 14 Mar. 1986 by a scanning spectrometer. The results provide accurate spectrophotometric measurements of the principal molecular bands from the 308 nm OH through the 918 nm CN emissions. The observations can be used to tie space derived ultraviolet and groundbased infrared observations to the optical observations and to one another. Additional observations were made of comet Giacobini-Zinner on 30 September 1985 of the same OH band and the 388 nm band of CN. The Swan band sequence ratios are used to test the best models of C2, with different ratios favoring different models, calling into question the assumptions of these very complete models.

Odell, C. R.↗

A high-precision ab initio determination of the equilibrium geometry and force field of HOC(+)

The results of an ab initio molecular orbital investigation of the isoformyl cation, HOC(+), shape are reported. The effects of expanding the basis set to near the Hartree-Fock limit and of electron correlation were examined, and the results indicate that near the Hartree-Fock limit the HOC(+) is linear. An analytic potential function is presented, from which the calculated rotational energies are only 0.03 percent different from the experimental values. This represents a nearly two orders of magnitude reduction in error from earlier work.

Defrees, D. J.↗

The Galileo Attitude and Articulation Control System - A radiation-hard, high precision, state-of-the-art control system

The Galileo Mission and Spacecraft design impose tight requirements on the Attitude and Articulation Control System (AACS). These requirements, coupled with the flexible spacecraft, the need for autonomy, and a severe radiation environment, pose a great challenge for the AACS designer. The resulting design and implementation are described, along with the discovery and solution of the Single-Event Upset problem. The status of the testing of the AACS in the Integration and Test Laboratory as well as at the spacecraft level is summarized.

Rhoads Stephenson, R.↗

Flight evaluation of an integrated control and display system for high-precision manual landing flare of powered-lift STOL aircraft

An account is given of the features and performance of a manual landing flare and touchdown system capable of great precision, as demonstrated by its installation in the NASA Quiet Short-haul Research Aircraft (QSRA). The integrated cockpit display and closed-loop control employed constitutes a trajectory-augmentation system that extends QSRA flight control from augmentation of altitude, flight path angle, and airspeed, to the augmentation of the trajectory itself. The + or - 18 ft touchdown dispersion achieved is approximately equal to that obtained during aircraft carrier trials of the same aircraft.

Hynes, Charles S.↗

Tele-autonomous control involving contacts: The applications of a high precision laser line range sensor

The object localization algorithm based on line-segment matching is presented. The method is very simple and computationally fast. In most cases, closed-form formulas are used to derive the solution. The method is also quite flexible, because only few surfaces (one or two) need to be accessed (sensed) to gather necessary range data. For example, if the line-segments are extracted from boundaries of a planar surface, only parameters of one surface and two of its boundaries need to be extracted, as compared with traditional point-surface matching or line-surface matching algorithms which need to access at least three surfaces in order to locate a planar object. Therefore, this method is especially suitable for applications when an object is surrounded by many other work pieces and most of the object is very difficult, is not impossible, to be measured; or when not all parts of the object can be reached. The theoretical ground on how to use line range sensor to located an object was laid. Much work has to be done in order to be really useful.

Volz, R. A.↗

Dating earthquakes with high-precision thorium-230 ages of very young corals

Three corals from Vanuatu Islands, whose ages were known from counting annual growth bands, were analyzed by Th-230 age analysis to asses the accuracy of the Th-230 method. The comparison of Th-230 ages with the growth-band ages showed that the Th-230 ages were accurate within an error of + or - 3-5 y. Th-230 dates were then determined for two adjacent emerged heads from Santo Island; the dates were the same, indicating that the heads died at the same time, and consistent with the theory that they were killed by coseismic emergence around 1865 AD. The difference between this data and the data of the only major historically documented earthquake that caused an uplift (1973) suggests a seismic recurrence interval of 108 + or - 4 y for Santo. It is suggested that this approach may be extended back in time and to other localities.

Edwards, R. Lawrence↗