Search NASA⌕ Search

SEARCH · Search NASA

Results for “index modulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Spectator field models in light of spectral index after Planck

We revisit spectator field models including curvaton and modulated reheating scenarios, specifically focusing on their viability in the new Planck era, based on the derived expression for the spectral index in general spectator field models. Importantly, the recent Planck observations give strong preference to a red-tilted power spectrum, while the spectator field models tend to predict a scale-invariant one. This implies that, during inflation, either (i) the Hubble parameter varies significantly as in chaotic inflation, or (ii) a scalar potential for the spectator field has a relatively large negative curvature. Combined with the tight constraint on the non-Gaussianity, the Planck data provides us with rich implications for various spectator field models.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The incommensurately modulated structures of low-temperature labradorite feldspars: a single-crystal X-ray and neutron diffraction study

Labradorite feldspars of the plagioclase solid solution series have been known for their complicated subsolidus phase relations and enigmatic incommensurately modulated structures. Characterized by the irrationally indexed e -reflections in the diffraction pattern, e -labradorite shows the largest variation in the incommensurate ordering states among the e -plagioclase structures. The strongly ordered low-temperature e -labradorite is one of the last missing pieces of the e -plagioclase puzzle. Nine plutonic and metamorphic labradorite feldspar samples from Canada, Ukraine, Minnesota (USA), Tanzania and Greenland with compositions ranging from An 52.5 to An 68 were studied with single-crystal X-ray diffraction. Two crystals from Labrador, Canada, and Duluth, MN, USA, with wide enough twin lamellae were analyzed with single-crystal neutron diffraction. The incommensurately modulated structures of e -plagioclase are refined for the first time with neutron diffraction data, which confirmed that the T—O distance modulation in the low-temperature e -plagioclase results from the Al–Si ordering in the framework. Detailed configurations of the M site are also observed in the structures refined from neutron diffraction data, which were not possible to see with X-ray diffraction data. The relation between the q -vectors and the mole% An composition is revealed for the entire compositional range of e -plagioclase, from An 25 to An 75 . The previously proposed two-trend relation depending on the cooling rate and phase transition path is confirmed. A new classification of e -plagioclase ( e α , e β and e γ ) is proposed based on the q -vector of the structure, which makes it an independent character from the presence/absence of density modulation. New parameters are proposed to quantify the ordering states of these complicated aperiodic structures of e -plagioclases, such as the difference between $\langle$T 1 o—O$\rangle$ and $\langle$T 1 m—O$\rangle$ at phase t = 0.2 or the normalized intensity of the (071\bar 1) reflection.

36 MATERIALS SCIENCE↗

Effect of self-phase modulation and cross-phase modulation on OFDM signals in fibre-optic access networks

We consider a passive fibre-optic transmission system using orthogonal subcarriers in channels with quadrature phase-shift keying and quadrature-amplitude modulation formats. A technique is proposed for estimating the signal quality index in orthogonal frequency division multiplexing, based on the transformation of phase distortions of channel carriers into distortions of signal levels. The deterioration in the quality index is found to be due to nonlinear phenomena (self-phase modulation and cross-phase modulation) and noise of the optical amplifier. Relations are given that allow an optimum power level of the optical signal to be chosen as a function of the modulation format of the channels. (fibre-optic communication)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Global Modeling of Mineral Dust and its Optical Thickness

Global distribution of dust in the atmosphere has been simulated using the NASA Goddard chemical transport model (GEOS-CTM) to help retrieve the aerosol optical thickness from TOMS absorbing aerosol index. The model contains a dust module which accounts for sources and removal processes. The transport is driven by the assimilated meteorological fields generated by the NASA Goddard Earth Observing System Data Assimilation System (GEOS DAS). One of the key parameters, in the retrieval algorithm of optical thickness from Total Ozone Mapping Spectrometer (TOMS) data, is the vertical profile of aerosols. During the period 10- 19 September 1994, Lidar on-space Technology Experiment (LITE) was flown on space shuttle Discovery. The 53 hours of data collected cover the lower atmosphere from the earth surface to 20 kilometers altitude and from 57 N to 57 S with a high resolution of about 15 meters. The model results are compared with LITE data over the source regions of dust (Africa, Middle East, Asia, Australia) and in the remote troposphere (Atlantic and Pacific). The simulated horizontal distribution is compared with TOMS absorbing aerosol index. Finally the calculated optical thickness will be assessed with ground based sun-photometers (AERONET).

Ginoux, Paul A.↗

BL LAC OBJECT PKS B1144-379: AN EXTREME SCINTILLATOR

Rapid variability in the radio flux density of the BL Lac object PKS B1144-379 has been observed at four frequencies, ranging from 1.5 to 15 GHz, with the Very Large Array and the University of Tasmania's Ceduna antenna. Intrinsic and line-of-sight effects were examined as possible causes of this variability, with interstellar scintillation best explaining the frequency dependence of the variability timescales and modulation indices. This scintillation is consistent with a compact source 20-40 {mu}as or 0.15-0.3 pc in size. The inferred brightness temperature for PKS B1144-379 (assuming that the observed variations are due to scintillation) is 6.2 Multiplication-Sign 10{sup 12} K at 4.9 GHz, with approximately 10% of the total flux in the scintillating component. We show that scintillation surveys aimed at identifying variability timescales of days to weeks are an effective way to identify the active galactic nuclei with the highest brightness temperatures.

79 ASTRONOMY AND ASTROPHYSICS↗

Two-dimensional distributed feedback lasers based on static and dynamic Bragg structures

In order to increase the output power of DFB lasers, we consider the possibility of using two-dimensional distributed feedback. Within the framework of this scheme, the feedback circuit includes four partial wave fluxes propagating in mutually orthogonal directions, which makes it possible to provide coherent radiation from a spatially extended planar active medium characterised by large values of the Fresnel parameter. By analogy with the onedimensional distributed feedback, the wave coupling can be ensured by using both the structures with a periodically varying effective refractive index (static two-dimensional Bragg structures) and the gain modulation (photo-induced two-dimensional Bragg structures). Within the semiclassical approximation, the initial conditions and nonlinear dynamics of lasers with the above-described two-dimensional Bragg structures are analysed. Self-similarity conditions are found, allowing one to scale the laser parameters with increasing active region size, which is accompanied by an increase in the integrated output power.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-F-T-528: Relationship Between Tumor Size and Plan Quality Using FFF and Non-FFF Modes in Rapidarc

Purpose: For a give PTV dose, beam-on time is shorter in the FFF than the non-FFF mode because of higher MU/min. Larger tumors usually require more complex intensity modulation, which might affect plan quality and total MU. We investigated the relationship between PTV size and plan quality using FFF and non-FFF modes. Methods: Two different PTV volumes (PTV and PTV+1 cm margin) were drawn in brain, lung and liver. 3-full to 7-partial arc (Rapidarc) of 6 MV, 1400 MU/min were studied. Plan quality was evaluated by: (a) DVH for PTV and normal tissues, (b) total MU and beam-on time, and (c) passing rate for IMRT plan QA. Results: For the same PTV coverage, DVH for normal tissue was the same or slightly lower in the FFF compared with non-FFF. Total MU was 13% higher in FFF than non-FFF in the 3-arc, 7 Gy treatment, but the difference became smaller when arc number increased to 6–7 for 10–24 Gy. Larger PTV did not affect the difference in the total MU. FFF required a short beam-on time and the ratio of FFF and non-FFF was 0.34 to 0.88 for 7- and 3-arc, respectively. For larger PTV, the ratio increased to 0.45–0.90. Ratio of total MU for large PTV was 3–8% lower in the non-FFF plans. Although the small difference in MU, beam-on time was 1.1 to-1.6 times longer in the 3- and 7-arc non-FFF plans. Plan verification showed the similar gamma index passing rate. Conclusion: While total MU was similar with FFF and non-FFF modes, the beam-on time was shorter in the FFF treatment. The advantage of FFF was greater in treatments with high dose per fraction using more arc numbers. For dose less than 10 Gy, using FFF and non-FFF modes, tumor size did not affect the relationship of total MU, beam-on time.

60 APPLIED LIFE SCIENCES↗

Accelerated Partial Breast Irradiation With IMRT: New Technical Approach and Interim Analysis of Acute Toxicity in a Phase III Randomized Clinical Trial

Purpose: To evaluate with a randomized clinical trial the possibility of treating the index quadrant with external intensity-modulated radiotherapy (IMRT) in a selected group of patients with early-stage breast cancer and to analyze the acute toxicity. Methods and Materials: From September 2005, a randomized Phase III clinical trial has been conducted to compare conventional (tangential field) fractionated whole breast treatment (Arm A) with accelerated partial breast irradiation plus intensity-modulated radiotherapy (Arm B). For intensity-modulated radiotherapy, the clinical target volume was drawn with a uniform 1-cm margin around the surgical clips in three dimensions. The ipsilateral and contralateral breast, ipsilateral and contralateral lung, heart, and spinal cord were contoured as organs at risk. All the regions of interest were contoured according to the International Commission on Radiation Units and Measurements reports 50 and 62 recommendations. Results: In September 2008, 259 patients were randomized and treated. The mean clinical target volume in Arm B was 44 cm{sup 3} and the mean planning target volume was 123 cm{sup 3}. The mean value of the ratio between the planning target volume and the ipsilateral breast volume was 21%. The rate of Grade 1 and Grade 2 acute skin toxicity was 22% and 19% in Arm A (Radiation Therapy Oncology Group scale), respectively. The tolerance in Arm B was excellent with only 5% Grade 1 and 0.8% Grade 2 acute skin toxicity. The planning constraints were fully satisfied in most patients. In a very few cases, this was not possible because of very unfavorable anatomy. Quality assurance procedures were performed according to our internal quality assurance protocol, with excellent results. Conclusion: In the present preliminary analysis, we have demonstrated that accelerated partial breast irradiation is feasible, with very low acute toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Airborne measurements of laser backscatter from the ocean surface

The data are taken with three different pulsed laser sources, one each in the ultraviolet (337.1 nm), visible (532.1 nm) and infrared (9.5 microns). The principal instrument is the airborne oceanographic lidar of the NASA Wallops Flight Facility. The data on mean laser backscatter and its variation with angle off nadir are found to be consistent with previous analytical work and some previous experimental work. The absolute calibration of this backscatter in terms of an effective Lambertian reflectance is less precise, but the data support values near nadir of approximately 0.20 for low wind speeds. It is noted that these values are 1 order of magnitude larger than the Fresnel reflectance for an air/water discontinuity in the refractive index. Whereas the normalized standard deviation (modulation factor) of backscatter is less well understood analytically, it is defined by these measurements to range from a few percent to over 50 percent at nadir and to increase off nadir as the tangent of theta or faster. The data are uncertain beyond 15 deg off nadir owing to a dynamic range limitation.

Bufton, J. L.↗

Omnidirectional mirror based on Bragg stacks with a periodic gain-loss modulation

In this work we demonstrate that a Bragg Stack with a periodic gain-loss modulation can function as an Omnidirectional Mirror (OM) with complete reflection at any angle of incidence irrespective of the light polarization. The Bragg Stack is composed by the periodic variation of two layers with the same value of the real part of the refractive index (n{sub r}) and a periodic modulation in the imaginary part (n{sub i}). The origin of the band gaps is due to the interference of complex waves with propagating and evanescent fields in each layer. It is found that the band gaps are wider as the contrast n{sub i}/n{sub r} increases. We have found the ambient conditions to obtain an OM considering an auxiliary medium n{sup ′} external to the Bragg Stack.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

EFFECT OF INTERACTING RAREFACTION WAVES ON RELATIVISTICALLY HOT JETS

The effect of rarefaction acceleration on the propagation dynamics and structure of relativistically hot jets is studied through relativistic hydrodynamic simulations. We emphasize the nonlinear interaction of rarefaction waves excited at the interface between a cylindrical jet and the surrounding medium. From simplified one-dimensional (1D) models with radial jet structure, we find that a decrease in the relativistic pressure due to the interacting rarefaction waves in the central zone of the jet transiently yields a more powerful boost of the bulk jet than that expected from single rarefaction acceleration. This leads to a cyclic in situ energy conversion between thermal and bulk kinetic energies, which induces radial oscillating motion of the jet. The oscillation timescale is characterized by the initial pressure ratio of the jet to the ambient medium and follows a simple scaling relation, {tau}{sub oscillation}{proportional_to}(P{sub jet,0}/P{sub amb,0}){sup 1/2}. Extended two-dimensional simulations confirm that this radial oscillating motion in the 1D system manifests as modulation of the structure of the jet in a more realistic situation where a relativistically hot jet propagates through an ambient medium. We find that when the ambient medium has a power-law pressure distribution, the size of the reconfinement region along the propagation direction of the jet in the modulation structure {lambda} evolves according to a self-similar relation {lambda}{proportional_to}t{sup {alpha}/2}, where {alpha} is the power-law index of the pressure distribution.

79 ASTRONOMY AND ASTROPHYSICS↗

Tomotherapy treatment plan quality assurance: The impact of applied criteria on passing rate in gamma index method

Purpose: Pretreatment patient plan verification with gamma index (GI) metric analysis is standard procedure for intensity modulated radiation therapy (IMRT) treatment. The aim of this paper is to evaluate the variability of the local and global gamma index obtained during standard pretreatment quality assurance (QA) measurements for plans performed with Tomotherapy unit. The QA measurements were performed with a 3D diode array, using variable passing criteria: 3%/3 mm, 2%/2 mm, 1%/1 mm, each with both local and global normalization.Methods: The authors analyzed the pretreatment QA results for 73 verifications; 37 were prostate cancer plans, 16 were head and neck plans, and 20 were other clinical sites. All plans were treated using the Tomotherapy Hi-Art System. Pretreatment QA plans were performed with the commercially available 3D diode array ArcCHECK™. This device has 1386 diodes arranged in a helical geometry spaced 1 cm apart. The dose measurements were acquired on the ArcCHECK™ and then compared with the calculated dose using the standard gamma analysis method. The gamma passing rate (%GP), defined as the percentage of points satisfying the condition GI < 1, was calculated for different criteria (3%/3 mm, 2%/2 mm, 1%/1 mm) and for both global and local normalization. In the case of local normalization method, the authors set three dose difference threshold (DDT) values of 2, 3, and 5 cGy. Dose difference threshold is defined as the minimum absolute dose error considered in the analysis when using local normalization. Low-dose thresholds (TH) of 5% and 10% were also applied and analyzed.Results: Performing a paired-t-test, the authors determined that the gamma passing rate is independent of the threshold values for all of the adopted criteria (5%TH vs 10%TH, p > 0.1). Our findings showed that mean %GPs for local (or global) normalization for the entire study group were 93% (98%), 84% (92%), and 66% (61%) for 3%/3 mm, 2%/2 mm, and 1%/1 mm criteria, respectively. DDT was equal to 2 cGy for the local normalization analysis cases. The authors observed great variability in the resulting %GP. With 3%/3 mm gamma criteria, the overall passing rate with local normalization was 4.6% less on the average than with global one, as expected. The wide difference between %GP calculated with global or local approach is also confirmed by an unpaired t-test statistical analysis.Conclusions: The variability of %GP obtained confirmed the necessity to establish defined agreement criteria that could be universal and comparable between institutions. In particular, while the gamma passing rate does not depend on the choice of threshold, the choice of DDT strongly influences the gamma passing rate for local calculations. The difference between global and local %GP was statistically significant for prostate and other treatment sites when DDT was changed from 2 to 3 cGy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Measurements of Holographic Properties of Bacteriorhodopsin Films

Several different bacteriorhodopsin (BR) films are characterized with respect to general holographic properties. Experimental measurements include diffraction efficiency and sensitivity as functions of writing intensity and grating frequency, hologram thermal decay behavior, diffraction efficiency as a function of grating tilt within the film and modulation depth, and estimates of the refractive index change from the diffraction efficiency data. The films studied include those made from wildtype BR and the genetic variants D96N and D96N/T46V. The maximum diffraction efficiency measured was just over 3% for a hydrated wildtype BR film. The films' holographic properties were found to be relatively insensitive to grating frequency and grating tilt angle. The diffraction efficiency dropped off more sharply as a function of modulation depth than a purely linear medium, and only the hydrated wildtype film exhibited significant behavior variation with different writing intensities.

Downie, John D.↗

Magnetospheric Accretion in PSR 1259-63

We report the results from X-ray and hard X-ray observations of the PSR B1259-63/SS 2883 system with the ASCA and the CGRO satellites, performed between 1995 February and 1996 January when the pulsar was near apastron. The system was clearly detected in each of the two ASCA observations with luminosity in the 1-10 keV band of L(sub X) = (9 +/- 3) x 10(exp 32) (d/2 kpc) erg/ s, while OSSE did not detect significant hard X-rays from the system. X-ray spectra obtained with ASCA show a single power-law spectrum with a photon index of 1.6 +/- 0.3. No pulsations were detected in either the ASCA nor the OSSE data. Combined with previous results from X-ray and hard X-ray observations, we obtained binary modulation in X-ray luminosity and photon index of high energy emission from the system for the entire orbit. The results are in agreement with predictions based on synchrotron emission model from relativistic particles in a shocked pulsar wind interacting with the gaseous outflow from the Be star.

Cominsky, Lynn R.↗

NEW PHOTOMETRICALLY VARIABLE MAGNETIC CHEMICALLY PECULIAR STARS IN THE ASAS-3 ARCHIVE

The magnetic Ap or CP2 stars are natural atomic and magnetic laboratories. Strictly periodic changes are observed in the spectra and brightness of these stars, which allow the derivation of rotational periods. Related to this group of objects are the He-weak (CP4) and He-rich stars, some of which also undergo brightness changes due to rotational modulation. Increasing the sample size of known rotational periods among CP2/4 stars is important and will contribute to our understanding of these objects and their evolution in time. We have compiled an extensive target list of CP2/4 stars from the General Catalog of Ap, HgMn, and Am stars, including several early-type (spectral types B/A) variables of undetermined type from the International Variable Star Index. We investigated our sample stars using publicly available observations from the ASAS-3 archive. Our previous efforts in this respect led to the discovery of 323 variable stars. Using a refined analysis approach, we were able to identify another 360 stars exhibiting photometric variability in ASAS-3 data. Summary data, folded light curves and, if available, information from the literature are presented for our final sample, which is composed of 334 bona-fide α{sup 2} Canum Venaticorum (ACV) variables, 23 ACV candidates, and 3 eclipsing binary systems. Interesting and unusual objects are discussed in detail. In particular, we call attention to HD 66051 (V414 Pup), which is an eclipsing binary system showing obvious rotational modulation of the light curve due to the presence of an ACV variable in the system.

79 ASTRONOMY AND ASTROPHYSICS↗

Solitonic Bloch oscillations in two-dimensional optical lattices

A theoretical description for nonlinear beam propagation in a two-dimensional optical lattice in the presence of a refractive-index gradient has been developed. This problem is associated with nonlinear Bloch oscillations; it has been reduced to a nonlinear Schroedinger equation with a varying dispersion coefficient. It is shown that, if the periodicity of longitudinal modulation coincides with the transverse gradient of the refractive index, a stationary oscillatory picture emerges in the nonlinear regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental Investigation of a Multiplex Fuel Injector Module With Discrete Jet Swirlers for Low Emission Combustors

A low-NOx emissions combustor concept has been demonstrated in flame-tube tests. A lean-direct injection (LDI) concept was used where the fuel is injected directly into the flame zone and the overall equivalence ratio of the mixture is lean. The LDI concept described in this report is a multiplex fuel injector module containing multipoint fuel injection tips and multi-burning zones. The injector module comprises 25 equally spaced injection tips within a 76 by 76 mm area that fits into the flame-tube duct. The air swirlers were made from a concave plate on the axis of the fuel injector using drilled holes at an angle to the axis of the fuel injector. The NOx levels were quite low and are greater than 70 percent lower than the 1996 ICAO standard. At an inlet temperature of 810 K, inlet pressure of 2760 kPa, pressure drop of 4 percent and a flame temperature of 1900 K with JP8 fuel, the NOx emission index was 9. The 25-point injector module exhibited the most uniform radial distribution of fuel-air mixture and NOx emissions in the flame tube when compared to other multipoint injection devices. A correlation is developed relating the NOx emissions to inlet temperature, inlet pressure, equivalence ratio and pressure drop.

Tacina, Robert↗

Dosimetric study of volumetric arc modulation with RapidArc and intensity-modulated radiotherapy in patients with cervical cancer and comparison with 3-dimensional conformal technique for definitive radiotherapy in patients with cervical cancer

Introduction: For patients with cervical cancer, intensity-modulated radiation therapy (IMRT) improves target coverage and allows dose escalation while reducing the radiation dose to organs at risk (OARs). In this study, we compared dosimetric parameters among 3-dimensional conformal radiotherapy (3D-CRT), “step-and-shoot” IMRT, and volumetric intensity-modulated arc radiotherapy (VMAT) in a series of patients with cervical cancer receiving definitive radiotherapy. Computed tomography (CT) scans of 10 patients with histologically proven cervical cancer treated with definitive radiation therapy (RT) from December 2008 to March 2010 at our department were selected for this study. The gross tumor volume (GTV) and clinical target volume (CTV) were delineated following the guidelines of the Gyn IMRT consortium that included cervix, uterus, parametrial tissues, and the pelvic nodes including presacral. The median age was 57 years (range: 30 to 85 years). All 10 patients had squamous cell carcinoma with Federation of Gynecology and Obstetrics (FIGO) stage IB-IIIB. All patients were treated by VMAT. OAR doses were significantly reduced for plans with intensity-modulated technique compared with 3D-CRT except for the dose to the vagina. Between the 2 intensity-modulated techniques, significant difference was observed for the mean dose to the small intestine, to the benefit of VMAT (p < 0.001). There was no improvement in terms of OARs sparing for VMAT although there was a tendency for a slightly decreased average dose to the rectum: − 0.65 Gy but not significant (p = 0.07). The intensity modulation techniques have many advantages in terms of quality indexes, and particularly OAR sparing, compared with 3D-CRT. Following the ongoing technologic developments in modern radiotherapy, it is essential to evaluate the intensity-modulated techniques on prospective studies of a larger scale.

61 RADIATION PROTECTION AND DOSIMETRY↗