Search NASA⌕ Search

SEARCH · Search NASA

Results for “infrared detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Identifying Organic Molecules in Space: The AstroBiology Explorer (ABE) Mission Concept

The AstroBiology Explorer (ABE) mission concept consists of a dedicated space observatory having a 60 cm class primary mirror cooled to T < 50 K equipped with medium resolution cross-dispersed spectrometers having cooled large format near- and mid-infrared detector arrays. Such a system would be capable of addressing outstanding problems in Astrochemistry and Astrophysics that are particularly relevant to Astrobiology and addressable via astronomical observation. The mission s observational program would make fundamental scientific progress in establishing the nature, distribution, formation and evolution of organic and other molecular materials in the following extra-terrestrial environments: 1) The Outflow of Dying Stars, 2) The Diffuse Interstellar Medium, 3) Dense Molecular Clouds, Star Formation Regions, and Young StellarPlanetary Systems, 4) Planets, Satellites, and Small Bodies within the Solar System, and 5 ) The Interstellar Media of Other Galaxies. ABE could make fundamental progress in all of these areas by conducting a 1 to 2 year mission to obtain a coordinated set of infrared spectroscopic observations over the 2.5-20 micron spectral range at a spectral resolution of R > 2000 of about 1500 objects including galaxies, stars, planetary nebulae, young stellar objects, and solar system objects. Keywords: Astrobiology, infrared, Explorers, interstellar organics, telescope, spectrometer, space, infrared detectors

Ennico, K. A.↗

Monolithic short wave infrared (SWIR) detector array

A monolithic self-scanned linear detector array was developed for remote sensing in the 1.1- 2.4-micron spectral region. A high-density IRCCD test chip was fabricated to verify new design approaches required for the detector array. The driving factors in the Schottky barrier IRCCD (Pdsub2Si) process development are the attainment of detector yield, uniformity, adequate quantum efficiency, and lowest possible dark current consistent with radiometric accuracy. A dual-band module was designed that consists of two linear detector arrays. The sensor architecture places the floating diffusion output structure in the middle of the chip, away from the butt edges. A focal plane package was conceptualized and includes a polycrystalline silicon substrate carrying a two-layer, thick-film interconnecting conductor pattern and five epoxy-mounted modules. A polycrystalline silicon cover encloses the modules and bond wires, and serves as a radiation and EMI shield, thermal conductor, and contamination seal.

Source record↗

Visible and infrared linear detector arrays for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) instrument uses four separate focal plane assemblies consisting of line array detectors that are multiplexed to a common J-FET preamp using a FET switch multiplexing (MUX) technique. A 32-element silicon line array covers the spectral range from 0.41 to 0.70 microns. Three additional 64-element indium antimonide (InSb) line arrays cover the spectral range from 0.68 to 2.45 microns. The spectral sampling interval per detector element is nominally 9.8 nm, giving a total of 224 spectral channels. All focal planes operate at liquid nitrogen temperature and are housed in separate dewars. Electrical performance characteristics include a read noise of less than 1000 e(-) in all channels, response and dark nonuniformity of 5 percent peak to peak, and quantum efficiency of greater than 60 percent.

Bailey, Gary C.↗

Visible and infrared linear detector arrays for the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

The Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) instrument uses four separate focal plane assemblies consisting of line array detectors that are multiplexed to a common J-FET preamp using a FET switch multiplexing (MUX) technique. A 32-element silicon line array covers the spectral range from 0.41 to 0.70 microns. Three additional 64-element indium antimonide (InSb) line arrays cover the spectral range from 0.68 to 2.45 microns. The spectral sampling interval per detector element is nominally 9.8 nm, giving a total of 224 spectral channels. All focal planes operate at liquid nitrogen temperature and are housed in separate dewars. Electrical performance characteristics include a read noise of less than 1000 e(-) in all channels, response and dark nonuniformity of 5 percent peak to peak, and quantum efficiency of greater than 60 percent.

Bailey, Gary C.↗

High Tc superconducting bolometric and nonbolometric infrared (IR) detectors

The original workplan for the first year of the project includes the following: establishment of a pilot superconductivity application laboratory at UDC to support the research component of the project; research on the source of electrical noise in High Tc superconducting films in order to optimize the film microstructure and lower the NEP; and lay the foundation of an academic support for exposing UDC students to the theory and application of High Tc superconductivity. Attached to this status report are abstracts and the course description for Introduction to Applications of Superconductivity.

Lakeou, Samuel↗

High Tc superconducting bolometric and nonbolometric infrared (IR) detectors

The workplan for the period August 1994 through August 1995 includes the following: (1) expand the Applied Superconductivity Laboratory to include stand-alone optical response and noise measurement setups; (2) pursue studies of the low frequency excess electrical noise in YBCO films; and (3) enhance the academic support component of the project through increased student and faculty participation.

Lakeou, Samuel↗

High Tc superconducting bolometric and nonbolometric infrared (IR) detectors

Activities carried out during the reporting period are summarized. The workplan for the period August 1994 to August 1995 included the following: (1) expansion of the Applied Superconductivity Laboratory to include stand-alone optical response and noise measurement setups; (2) study the low frequency excess electrical noise in YBCO films; and (3) enhancement of the academic support component of the project through increased student and faculty participation. Abstracts of papers submitted for publication during this reporting period are included as attachments.

Lakeou, Samuel↗

Reducing the Read Noise of the James Webb Space Telescope Near Infrared Spectrograph Detector Subsystem

We describe a Wiener optimal approach to using the reference output and reference pixels that are built into Teledyne's HAWAII-2RG detector arrays. In this way, we are reducing the total noise per approximately 1000 second 88 frame up-the-ramp dark integration from about 6.5 e- rms to roughly 5 e- rms. Using a principal components analysis formalism, we achieved these noise improvements without altering the hardware in any way. In addition to being lower, the noise is also cleaner with much less visible correlation. For example, the faint horizontal banding that is often seen in HAWAII-2RG images is almost completely removed. Preliminary testing suggests that the relative gains are even higher when using non flight grade components. We believe that these techniques are applicable to most HAWAII-2RG based instruments.

Rauscher, Bernard↗

Sensor requirements for Earth and planetary observations

Future generations of Earth and planetary remote sensing instruments will require extensive developments of new long-wave and very long-wave infrared detectors. The upcoming NASA Earth Observing System (EOS) will carry a suite of instruments to monitor a wide range of atmospheric and surface parameters with an unprecedented degree of accuracy for a period of 10 to 15 years. These instruments will observe Earth over a wide spectral range extending from the visible to nearly 17 micrometers with a moderate to high spectral and spacial resolution. In addition to expected improvements in communication bandwidth and both ground and on-board computing power, these new sensor systems will need large two-dimensional detector arrays. Such arrays exist for visible wavelengths and, to a lesser extent, for short wavelength infrared systems. The most dramatic need is for new Long Wavelength Infrared (LWIR) and Very Long Wavelength Infrared (VLWIR) detector technologies that are compatible with area array readout devices and can operate in the temperature range supported by long life, low power refrigerators. A scientific need for radiometric and calibration accuracies approaching 1 percent translates into a requirement for detectors with excellent linearity, stability and insensitivity to operating conditions and space radiation. Current examples of the kind of scientific missions these new thermal IR detectors would enhance in the future include instruments for Earth science such as Orbital Volcanological Observations (OVO), Atmospheric Infrared Sounder (AIRS), Moderate Resolution Imaging Spectrometer (MODIS), and Spectroscopy in the Atmosphere using Far Infrared Emission (SAFIRE). Planetary exploration missions such as Cassini also provide examples of instrument concepts that could be enhanced by new IR detector technologies.

Chahine, Moustafa T.↗

Low background spectral response of 30-130-micron detectors from blackbody measurements

Low background far infrared detector responsivity and low background spectral response calibrations can be performed simultaneously with a cooled, temperature-swept blackbody. This makes the use of a cooled, low background spectrometer unnecessary in many applications. Calibrations of a beryllium-doped germanium detector showing unwanted 100-micron response, and of a gallium-doped germanium detector, are described.

Moore, W. J.↗

Infrared temperature maps of EHD lubrication

Technique uses an infrared detector with two specially selected infrared filters, in separately mapping the contact-surface temperature and average oil-film temperature in an elastohydrodynamic conjunction. Apparatus includes conventional four-ball bearing tester and temperature controlled lubricant system.

Sanborn, D. M.↗

Arrays: The Heart and Soul of SIRTIF

This paper describes the status of NASA's Space Infrared Telescope Facility (SIRTF) program. SIRTF will be a cryogenically cooled observatory for infrared astronomy from space and is planned for launch early in the next decade. It will be the first cryogenic observatory to make extensive use of the powerful infrared detector array technology discussed at this conference. We summarize a newly developed SIRTF mission concept and show how the availability of detector arrays has shaped the scientific rationale for SIRTF, and how the arrays themselves have become part of the definition of the SIRTF mission.

SIRTF infrared detector arrays Space Infrared Tele↗

Long-Wavelength Infrared (LWIR) Quantum Dot Infrared Photodetector (QDIP) Focal Plane Array

We have exploited the artificial atomlike properties of epitaxially self-assembled quantum dots for the development of high operating temperature long wavelength infrared (LWIR) focal plane arrays. Quantum dots are nanometer-scale islands that form spontaneously on a semiconductor substrate due to lattice mismatch. QDIPs are expected to outperform quantum well infrared detectors (QWIPs) and are expected to offer significant advantages over II-VI material based focal plane arrays. QDIPs are fabricated using robust wide bandgap III-V materials which are well suited to the production of highly uniform LWIR arrays. We have used molecular beam epitaxy (MBE) technology to grow multi-layer LWIR quantum dot structures based on the InAs/InGaAs/GaAs material system. JPL is building on its significant QWIP experience and is basically building a Dot-in-the-Well (DWELL) device design by embedding InAs quantum dots in a QWIP structure. This hybrid quantum dot/quantum well device offers additional control in wavelength tuning via control of dot-size and/or quantum well sizes. In addition the quantum wells can trap electrons and aide in ground state refilling. Recent measurements have shown a 10 times higher photoconductive gain than the typical QWIP device, which indirectly confirms the lower relaxation rate of excited electrons (photon bottleneck) in QDPs. Subsequent material and device improvements have demonstrated an absorption quantum efficiency (QE) of approx. 3%. Dot-in-the-well (DWELL) QDIPs were also experimentally shown to absorb both 45 deg. and normally incident light. Thus we have employed a reflection grating structure to further enhance the quantum efficiency. JPL has demonstrated wavelength control by progressively growing material and fabricating devices structures that have continuously increased in LWIR response. The most recent devices exhibit peak responsivity out to 8.1 microns. Peak detectivity of the 8.1 micrometer devices has reached approx. 1 x 10(exp 10) Jones at 77 K. Furthermore, we have fabricated the first long-wavelength 640x512 pixels QDP focal plane array. This QDIP focal plane may has produced excellent infrared imagery with noise equivalent temperature difference of 40 mK at 60K operating temperature. In addition, we have managed to increase the quantum efficiency of these devices from 0.1% (according to the data published in literature) to 20% in discrete devices. This is a factor of 200 increase in quantum efficiency. With these excellent results, for the first time QDIP performance has surpassed the QWIP performance. Our goal is to operate these long-wavelength detectors at much higher operating temperature than 77K which can be passively achieved in space. This will be a huge leap in high performance infrared detectors specifically applicable to space science instruments.

infrared imaging↗

Semiconductor Bolometers Give Background-Limited Performance

Semiconductor bolometers that are capable of detecting electromagnetic radiation over most or all of the infrared spectrum and that give background-limited performance at operating temperatures from 20 to 300 K have been invented. The term background-limited performance as applied to a bolometer, thermopile, or other infrared detector signifies that the ability to detect infrared signals that originate outside the detector is limited primarily by thermal noise attributable to the background radiation generated external to the bolometer. The signal-to-noise ratios and detectivities of the bolometers and thermopiles available prior to this invention have been lower than those needed for background-limited performance by factors of about 100 and 10, respectively. Like other electrically resistive bolometers, a device according to the invention exhibits an increase in electrical resistance when heated by infrared radiation. Depending on whether the device is operated under the customary constant- current or constant-voltage bias, the increase in electrical resistance can be measured in terms of an increase in voltage across the device or a decrease in current through the device, respectively. In the case of a semiconductor bolometer, it is necessary to filter out visible and shorter-wavelength light that could induce photoconductivity and thereby counteract all or part of the desired infrared- induced increase in resistance. The basic semiconductor material of a bolometer according to the invention is preferably silicon doped with one or more of a number of elements, each of which confers a different variable temperature coefficient of resistance. Suitable dopants include In, Ga, S, Se, Te, B, Al, As, P, and Sb. The concentration of dopant preferably lies in the range between 0.1 and 1,000 parts per billion.

Goebel, John↗

GaAs Multiplexers for VLWIR Detector Readout Below 10 Kelvin

A multiplexer and buffer based on GaAs JFET technology is presented. This multiplexer operates normally from room temperature down to 4 Kelvin and is suitable for the readout of Very Long Wavelength Infrared Detectors that must be cooled to below 10 Kelvin.

detector arrays GaAs multiplexers↗

Application of infrared radiometers for airborne detection of clear air turbulence and low level wind shear, airborne infrared low level wind shear detection test

The feasibility of infrared optical techniques for the advance detection and avoidance of low level wind shear (LLWS) or low altitude wind shear hazardous to aircraft operations was investigated. A primary feasibility research effort was conducted with infrared detectors and instrumentation aboard the NASA Ames Research Center Learjet. The main field effort was flown on the NASA-Ames Dryden B57B aircraft. The original approach visualized a forward-looking, infrared transmitting (KRS-5) window through which signals would reach the detector. The present concept of a one inch diameter light pipe with a 45 deg angled mirror enables a much simpler installation virtually anywhere on the aircraft coupled with the possibility of horizontal scanning via rotation of the forward directed mirror. Present infrared detectors and filters would certainly permit ranging and horizontal scanning in a variety of methods. CRT display technology could provide a contoured picture with possible shear intensity levels from the infrared detection system on the weather radar or a small adjunct display. This procedure shoud be further developed and pilot evaluated in a light aircraft such as a Cessna 207 or equivalent.

Kuhn, P. M.↗