The Atmospheres of Titan and Saturn in the Infrared from Cassini: The Interplay Between Observation and Laboratory Studies

The Composite Infrared Spectrometer (CIRS) aboard the Cassini spacecraft has been recording spectra of Saturn and Titan since its arrival in the Saturn system in 2004. CIRS, a Fourier transform spectrometer, observes the thermal infrared spectrum of both atmospheres from 10 to 1500/cm with resolutions up to 0.5/cm (Flasar et al. 2004). From these data CIRS provides global coverage of the molecular composition of the stratosphere and troposphere, as well as maps of temperature and winds. From such studies CIRS helps reveal the chemistry and evolutionary history of Saturn and Titan and their relationships to other Solar System bodies. The Cassini mission is continuing until 2017, permitting CIRS to search for atmospheric changes during more than a Saturnian season. By combining with results from Voyager (1980, 1981) the baseline becomes more than one Saturnian year (Coustenis et al. 2011). CIRS spectroscopy of the atmospheres of Saturn and Titan has raised a variety of questions that require new laboratory studies. A complete understanding of the CIRS high-resolution atmospheric spectra cannot be fully achieved without new or improved line positions and intensities for some trace molecules (e.g., Nixon et al. 2009). Isotopic variants of some of the more abundant species often need improved line parameters in order to derive isotopic ratios (e.g., Coustenis et al. 2008 and Fletcher et a!. 2009). Isotopic ratios contain information about the history of an atmosphere if experimental fractionation rates are available (Jennings et al. 2009). Some aerosol and haze features continue to defy identification and will not be explained without better knowledge of how these materials are formed and until we obtain their laboratory spectra. The interaction between CIRS investigations and laboratory research has been productive and has already led to new discoveries.

Jennings, D. E.↗

Scanning Laser Infrared Molecular Spectrometer (SLIMS)

This prototype innovation is a novel design that achieves very long, effective laser path lengths that are able to yield ppb (parts per billion) and sub-ppb measurements of trace gases. SLIMS can also accommodate multiple laser channels covering a wide range of wavelengths, resulting in detection of more chemicals of interest. The mechanical design of the mirror cell allows for the large effective path length within a small footprint. The same design provides a robust structure that lends itself to being immune to some of the alignment challenges that similar cells face. By taking a hollow cylinder and by cutting an elliptically or spherically curved surface into its inner wall, the basic geometry of a reflecting ring is created. If the curved, inner surface is diamond-turned and highly polished, a surface that is very highly reflective can be formed. The surface finish can be further improved by adding a thin chrome or gold film over the surface. This creates a high-quality, curved, mirrored surface. A laser beam, which can be injected from a small bore hole in the wall of the cylinder, will be able to make many low-loss bounces around the ring, creating a large optical path length. The reflecting ring operates on the same principle as the Herriott cell. The difference exists in the mirror that doesn't have to be optically aligned, and which has a relatively large, internal surface area that lends itself to either open air or evacuated spectroscopic measurements. This solid, spherical ring mirror removes the possibility of mirror misalignment caused by thermal expansion or vibrations, because there is only a single, solid reflecting surface. Benefits of the reflecting ring come into play when size constraints reduce the size of the system, especially for space missions in which mass is at a premium.

Scott, David C.↗

Near Real Time Prospecting for Lunar Volatiles: Demonstrating RESOLVE Science in the Field

The Regolith and Environment Science and Oxygen & Lunar Volatile Extraction (RESOLVE) project aims to demonstrate the utility of "in situ resource utilization". In situ resource utilization (ISRU) is a way to rebalance the economics of spaceflight by reducing or eliminating materials that must be brought up from Earth and placed on the surface of the Moon for human use. RESOLVE is developing a rover-borne payload that (1) can locate near subsurface volatiles, (2) excavate and analyze samples of the volatile-bearing regolith, and (3) demonstrate the form, extractability and usefulness of the materials. Such investigations are important not only for ISRU but are also critically important for understanding the scientific nature of these intriguing lunar polar volatile deposits. Temperature models and orbital data suggest near surface volatile concentrations may exist at briefly lit lunar polar locations outside persistently shadowed regions. A lunar rover could be remotely operated at some of these locations for the 4-7 days of expected sunlight at relatively low cost. In July 2012 the RESOLVE project conducted a full-scale field demonstration. In particular, the ability to perform the real-time measurement analysis necessary to search for volatiles and the ability to combine the various measurement techniques to meet the mission measurement and science goals. With help from the Pacific International Space Center for Exploration Systems (PISCES), a lunar rover prototype (provided by the Canadian Space Agency) was equipped with prospecting instruments (neutron spectrometer and near-infrared spectrometer), subsurface access and sampling tools, including both an auger and coring drill (provided by CSA) and subsurface sample analysis instrumentation, including a sample oven system, the Oxygen and Volatile Extraction Node (OVEN), and Gas Chromatograph / Mass Spectrometer system, the Lunar Advanced Volatile Analysis (LAVA) system. Given the relatively short time period this lunar mission is being designed to, prospecting needs to occur in near real-time. The two prospecting instruments are the neutron and NIR spectrometers. In the field demo a small radioactive source was provided the neutron flux. The NIR spectrometer, which includes its own light source, looks at surface reflectance for signatures of bound H20/0H and general mineralogy. Once a "hot spot" was found by the prospecting instruments, the drill could either auger or core. The auger drill worked to a depth of 50 cm and is monitored with a drill camera and the NIR spectrometer. As cuttings are brought up the NIR spectra is monitored. If a particular location is considered of high -interest then the decision to core could be made. The coring drill (a push-tube) allowed a meter sample to be acquired processed by the OVEN/LAVA sys-tem. This presentation will provide details as how these instruments worked together and how and if the planned measurements and science was obtained.

Elphic, Richard↗

Extending MGS-TES Temperature Retrievals in the Martian Atmosphere up to 90 Km: Retrieval Approach and Results

This paper describes a methodology for performing a temperature retrieval in the Martian atmosphere in the 50-90 km altitude range using spectrally integrated 15 micrometers C02 limb emissions measured by the Thermal Emission Spectrometer (TES), the thermal infrared spectrometer on board the Mars Global Surveyor (MGS). We demonstrate that temperature retrievals from limb observations in the 75-90 km altitude range require accounting for the non-local thermodynamic equilibrium (non-LTE) populations of the C02(v2) vibrational levels. Using the methodology described in the paper, we have retrieved approximately 1200 individual temperature profiles from MGS TES limb observations in the altitude range between 60 and 90 km. 0ur dataset of retrieved temperature profiles is available for download in supplemental materials of this paper. The temperature retrieval uncertainties are mainly caused by radiance noise, and are estimated to be about 2 K at 60 km and below, 4 K at 70 km, 7 K at 80 km, 10 K at 85 km, and 20 K at 90 km. We compare the retrieved profiles to Mars Climate Database temperature profiles and find good qualitative agreement. Quantitatively, our retrieved profiles are in general warmer and demonstrate strong variability with the following values for bias and standard deviations (in brackets) compared to the Martian Year 24 dataset of the Mars Climate Database: 6 (+/-20) K at 60 km, 7.5 (+/-25) K at 65 km, 9 (+/-27) K at 70 km, 9.5 (+/-27) K at 75 km, 10 (+/-28) K at 80 km, 11 (+/-29) K at 85 km, and 11.5 (+/-31) K at 90 km. Possible reasons for the positive temperature bias are discussed. carbon dioxide molecular vibrations

temperature retrievals↗

The Volatiles Investigating Polar Exploration Rover (VIPER) Near Infrared Volatile Spectrometer System (NIRVSS).

NASA’s VIPER mission is planned for delivery to the lunar surface in late 2023 [1]. VIPER’s science objectives are to: 1) characterize the distribution and physical state of lunar polar water and other volatiles in lunar cold traps and regolith to under-stand their origin and 2) provide the data necessary for NASA to evaluate the potential return of relying upon in-situ resource utilization from the lunar polar regions [1]. The NIRVSS instrument, matured through several R&D programs to TRL 6 [2,3,4], has been chosen as part of the VIPER science payload [5].

T. L. Roush↗

Spectral Monitoring of Volatiles During Drilling into Frozen Lunar Simulant

NASA's Resource Prospector (RP) project intends to characterize the 3D distribution of volatiles in permanently shadowed regions at the lunar poles. One RP remote sensing instrument is a near-infrared spectrometer with an associated camera and radiometer, called the Near-InfraRed Volatile Spectrometer System (NIRVSS). In May 2016, NIRVSS, a Honeybee Robotics drill, and an Inficon mass spectrometer were placed in a vacuum chamber at Glenn Research Center. Also inside was a tube (1.2 m high x 25 cm diameter) filled with lunar simulant NU-LHT-3M, initially doped with a homogeneous water abundance of ~5%, chilled to cryogenic temperatures and exposed to a vacuum (~10e-6 Torr). During drilling, the NIRVSS instruments observed the cuttings pile as subsurface materials were emplaced on the surface. Spectral features associated with water ice, near 2000 and 3000 nm, were measured by the spectrometer during drilling. The spectral data documents development of a desiccated soil layer in the tube down to ~25-30 cm (confirmed by post-test soil analyses), formed during the initial pump down to vacuum. Drilling occurred in 10 cm segments, with the drill stem extracted and flutes brushed after each 10 cm depth. One exception to this was the 40 cm depth segment where the soil was delivered to a sample capture mechanism, and sealed for post-test analyses. To ~30 cm depth the greatest 2000 and 3000 nm signatures were associated with brushing of the drill flutes above the surface. At depths >40 cm the strongest ice signatures were associated with the drill clearing soil from the existing hole, or beginning to encounter new material. For these greater depths, brushing the flutes after extraction produced much weaker ice signatures than for shallower depths. This suggests that the soil may remain trapped in the exit funnel and is not emplaced on the surface. After each event creating strong ice signatures, these signatures decreased to near background levels in 5 minutes or less, due to surface exposure to vacuum.

lunar poles↗

Infrared Low-Cloud Detection

Traditional down-looking infrared techniques for the detection and study of clouds have difficulties when clouds are within approximately 200 mbar of the surface. This is because of the lack of thermal contrast between the surface and a low cloud. We present a technique that, using a prior knowledge of the total water column, allows a down-looking high spectral resolution infrared spectrometer to recognize when a significant fraction of its field-of-view contains optically thick clouds (low-altitute or not).

clouds total water column down-looking high-spectr↗