Search NASA⌕ Search

SEARCH · Search NASA

Results for “instructions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Experimental system for the control of surgically induced infections, operating and maintenance instructions D203613-004

An experimental portable system used to control surgically induced infections is described. The system consists of a portable clean room comprised of a laminar flow filter system consistent with Federal standards; a helmet-shoulder pad assembly; a communication system; a helmet ventilation system; a transparent walled enclosure; and surgical gowns. Guidelines for the set up and operation of such equipment are given along with corrective steps to use in case of system malfunctions. Cleaning procedures, maintenance requirements, and disassembly and transfer particulars are included.

Tevebaugh, M. D.↗

Handbook of operation and maintenance instructions for Model 5208A bit synchronizer unit

Electrical/mechanical characteristics, operation, theory of operation, parts list, and electrical diagrams for the model 5208A bit synchronizer unit are provided. The unit is capable of performing the functions of bit synchronization and signal conditioning on demodulated wave trains containing amplitude, frequency, and phase distortions, as well as additive noise. Operating frequencies in the 1 to 27 MHz bit rate range are accommodated through the use of discrete frequency plug-in subunits. The unit provides 0 and 180 degree clocks and either a single signal hard decision, or a three bit quantized soft decision data output.

Source record↗

Instructions for the use of the FORTRAN 4 program COMPT

The programming manual for the program COMPT which computes the non-steady two dimensional flow field resulting from the interaction of two successive blade rows is presented. The manual is designed to provide guidance in running the program and a brief description of some of the numerical details. A brief review of the main features of the program is given.

Alzner, E.↗

A method for determining the response of space shuttle to atmospheric turbulence. Volume 2: Computer program description and usage instructions

A description is given of a computer program which calculates the response of an elastic aerospace vehicle to random and discrete turbulence. The program uses vibration modes as generalized coordinates. Inputs to the program include modal information, generalized aerodynamic forces, flight data, stability augmentation system description, and description of the disturbing function. Program outputs include tabulations of the ratio of root-mean-square response to root-mean-square turbulence and response upward zero crossings per second, and SC4020 plots of transfer functions, response power spectral densities, and Nyquist stability traces.

Huntington, R.↗

Implementing instructions for KSC systems and safety training

The requirements for the safety training program are reported for KSC including transportation, inspection, checkout operations, maintenance of launch vehicles, spacecraft, ground support equipment, and launch teams. The responsibilities and mechanics for implementing the program are outlined.

Source record↗

Development of a long wavelength spectrometer for the 24-channel multispectral scanner: Instructions for installation, start-up, and adjustment

The basic information is presented, which is required for start-up and operation of two long-wavelength focal-plane and cooler assemblies, including the amplifiers and temperature control systems. The focal plane systems, referred to as the long wavelength spectrometer (LWS) were developed for direct replacement of Arrays 3 and 4 into the multispectral scanner presently being operated by the NASA Manned Spacecraft Center Facility, and Laboratory Support Branch. The equipment is comprised of two major sub-assemblies: Array 3 with three indium antimonide detector channels and Array 4 with seven mercury doped Germanium detector channels. Each array is mounted on a cryogenic cooler and includes the vacuum housings, mounting hardware (x, y, z translation and rotation stages) and detector signal conditioning, temperature control and monitoring electronics. The two arrays were designed to operate independently and do not share common equipment (viz power supplies, housings, mounts, etc.).

Source record↗

Hybrid 3-D rocket trajectory program. Part 1: Formulation and analysis. Part 2: Computer programming and user's instruction

Models utilizing various sub-sets of the six degrees of freedom are used in trajectory simulation. A 3-D model with only linear degrees of freedom is especially attractive, since the coefficients for the angular degrees of freedom are the most difficult to determine and the angular equations are the most time consuming for the computer to evaluate. A computer program is developed that uses three separate subsections to predict trajectories. A launch rail subsection is used until the rocket has left its launcher. The program then switches to a special 3-D section which computes motions in two linear and one angular degrees of freedom. When the rocket trims out, the program switches to the standard, three linear degrees of freedom model.

Huang, L. C. P.↗

Instruction manual, optical effects module electronic controller and processor, model OEMCP

The OEM-1 electronic module is discussed; it is comprised of four subsystems: the signal processing and display; the stepper motor controls; the chopper controls; and the dc-dc invertor. The OEM-1 module controls the sample wheel so that the relative transmittance of the samples can be compared to the clear aperture position. The 3-1/2 digit digital voltmeter displays the clear aperture signal level as well as the ratio of the remaining sample positions relative to the clear aperture position. The sample wheel position is decoded so that the signals and ratios can be correlated to the data. The OEM is automatically reset to the I sub o on initial turn-on and can be reset to the '0' position by actuating a front panel switch. The sample wheel can be interrupted to change samples or induce a longer integration time if desired by a front panel command. Integration times from 1 - 50 seconds are provided at the front panel, and BCD data for external interfacing is provided.

Source record↗

Instruction manual, Optical Effects Module, Model OEM

The Optical Effects Module Model OEM-1, a laboratory prototype instrument designed for the automated measurement of radiation transmission and scattering through optical samples, is described. The system comprises two main components: the Optical Effects Module Enclosure (OEME) and the Optical Effects Module Electronic Controller and Processor (OEMCP). The OEM is designed for operation in the near UV at approximately 2540A, corresponding to the most intense spectral line activated by the mercury discharge lamp used for illumination. The radiation from this source is detected in transmission and reflection through a number of selectable samples. The basic objective of this operation is to monitor in real time the accretion of possible contamination on the surface of these samples. The optical samples are exposed outside of the OEME proper to define exposure conditions and to separate exposure and measurement environments. Changes in the transmissivity of the sample are attributable to surface contamination or to bulk effects due to radiation. Surface contamination will increase radiation scattering due to Rayleigh-Gans effect or to other phenomena, depending on the characteristics size of the particulate contaminants. Thus, also scattering from the samples becomes a part of the measurement program.

Source record↗

LUMIS Interactive graphics operating instructions and system specifications

The LUMIS program has designed an integrated geographic information system to assist program managers and planning groups in metropolitan regions. Described is the system designed to interactively interrogate a data base, display graphically a portion of the region enclosed in the data base, and perform cross tabulations of variables within each city block, block group, or census tract. The system is designed to interface with U. S. Census DIME file technology, but can accept alternative districting conventions. The system is described on three levels: (1) introduction to the systems's concept and potential applications; (2) the method of operating the system on an interactive terminal; and (3) a detailed system specification for computer facility personnel.

Bryant, N. A.↗

Users' instructions for the NASA/MSFC cloud-rise preprocessor program, version 6, and the NASA/MSFC multilayer diffusion program, version 6: Research version for Univac 1108 system

The cloud-rise preprocessor and multilayer diffusion computer programs were used by NASA in predicting concentrations and dosages downwind from normal and abnormal launches of rocket vehicles. These programs incorporated: (1) the latest data for the heat content and chemistry of rocket exhaust clouds; (2) provision for the automated calculation of surface water pH due to deposition of HCl from precipitation scavenging; (3) provision for automated calculation of concentration and dosage parameters at any level within the vertical grounds for which meteorological inputs have been specified; and (4) provision for execution of multiple cases of meteorological data. Procedures used to automatically calculate wind direction shear in a layer were updated.

Bjorklund, J. R.↗

User's instructions for the Grodins' respiratory control model using the UNIVAC 1110 remote batch and demand processing

The transient and steady state response of the respiratory control system for variations in volumetric fractions of inspired gases and special system parameters are modeled. The program contains the capability to change workload. The program is based on Grodins' respiratory control model and can be envisioned as a feedback control system comprised of a plant (the controlled system) and the regulating component (controlling system). The controlled system is partitioned into 3 compartments corresponding to lungs, brain, and tissue with a fluid interconnecting patch representing the blood.

Source record↗

User's instructions for the 41-node thermoregulatory model (steady state version)

A user's guide for the steady-state thermoregulatory model is presented. The model was modified to provide conversational interaction on a remote terminal, greater flexibility for parameter estimation, increased efficiency of convergence, greater choice of output variable and more realistic equations for respiratory and skin diffusion water losses.

Leonard, J. I.↗

User's instructions for the erythropoiesis regulatory model

The purpose of the model provides a method to analyze some of the events that could account for the decrease in red cell mass observed in crewmen returning from space missions. The model is based on the premise that erythrocyte production is governed by the balance between oxygen supply and demand at a renal sensing site. Oxygen supply is taken to be a function of arterial oxygen tension, mean corpuscular hemoglobin concentration, oxy-hemoglobin carrying capacity, hematocrit, and blood flow. Erythrocyte destruction is based on the law of mass action. The instantaneous hematocrit value is derived by integrating changes in production and destruction rates and accounting for the degree of plasma dilution.

Source record↗