Quantitative assessment of the accuracy of dose calculation using pencil beam and Monte Carlo algorithms and requirements for clinical quality assurance

To compare the doses calculated using the BrainLAB pencil beam (PB) and Monte Carlo (MC) algorithms for tumors located in various sites including the lung and evaluate quality assurance procedures required for the verification of the accuracy of dose calculation. The dose-calculation accuracy of PB and MC was also assessed quantitatively with measurement using ionization chamber and Gafchromic films placed in solid water and heterogeneous phantoms. The dose was calculated using PB convolution and MC algorithms in the iPlan treatment planning system from BrainLAB. The dose calculation was performed on the patient's computed tomography images with lesions in various treatment sites including 5 lungs, 5 prostates, 4 brains, 2 head and necks, and 2 paraspinal tissues. A combination of conventional, conformal, and intensity-modulated radiation therapy plans was used in dose calculation. The leaf sequence from intensity-modulated radiation therapy plans or beam shapes from conformal plans and monitor units and other planning parameters calculated by the PB were identical for calculating dose with MC. Heterogeneity correction was considered in both PB and MC dose calculations. Dose-volume parameters such as V95 (volume covered by 95% of prescription dose), dose distributions, and gamma analysis were used to evaluate the calculated dose by PB and MC. The measured doses by ionization chamber and EBT GAFCHROMIC film in solid water and heterogeneous phantoms were used to quantitatively asses the accuracy of dose calculated by PB and MC. The dose-volume histograms and dose distributions calculated by PB and MC in the brain, prostate, paraspinal, and head and neck were in good agreement with one another (within 5%) and provided acceptable planning target volume coverage. However, dose distributions of the patients with lung cancer had large discrepancies. For a plan optimized with PB, the dose coverage was shown as clinically acceptable, whereas in reality, the MC showed a systematic lack of dose coverage. The dose calculated by PB for lung tumors was overestimated by up to 40%. An interesting feature that was observed is that despite large discrepancies in dose-volume histogram coverage of the planning target volume between PB and MC, the point doses at the isocenter (center of the lesions) calculated by both algorithms were within 7% even for lung cases. The dose distributions measured with EBT GAFCHROMIC films in heterogeneous phantoms showed large discrepancies of nearly 15% lower than PB at interfaces between heterogeneous media, where these lower doses measured by the film were in agreement with those by MC. The doses (V95) calculated by MC and PB agreed within 5% for treatment sites with small tissue heterogeneities such as the prostate, brain, head and neck, and paraspinal tumors. Considerable discrepancies, up to 40%, were observed in the dose-volume coverage between MC and PB in lung tumors, which may affect clinical outcomes. The discrepancies between MC and PB increased for 15 MV compared with 6 MV indicating the importance of implementation of accurate clinical treatment planning such as MC. The comparison of point doses is not representative of the discrepancies in dose coverage and might be misleading in evaluating the accuracy of dose calculation between PB and MC. Thus, the clinical quality assurance procedures required to verify the accuracy of dose calculation using PB and MC need to consider measurements of 2- and 3-dimensional dose distributions rather than a single point measurement using heterogeneous phantoms instead of homogenous water-equivalent phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Accuracy of Inhomogeneity Corrections in Intensity Modulated Radiation Therapy Planning in Philips Pinnacle System

The degree of accuracy of inhomogeneity corrections in a treatment planning system is dependent on the algorithm used by the system. The choice of field size, however, could have an effect on the calculation accuracy as well. There have been several evaluation studies on the accuracy of inhomogeneity corrections used by different algorithms. Most of these studies, however, focus on evaluating the dose in phantom using simplified geometry and open/static fields. This work focuses on evaluating the degree of dose accuracy in calculations involving intensity-modulated radiation therapy (IMRT) fields incident on a phantom containing both lung- and bone-equivalent heterogeneities using 6 and 10 MV beams. IMRT treatment plans were generated using the Philips Pinnacle treatment planning system and delivered to a phantom containing 55 thermoluminescent dosimeter (TLD) locations within the lung and bone and near the lung and bone interfaces with solid water. The TLD readings were compared with the dose predicted by the planning system. We find satisfactory agreement between planned and delivered doses, with an overall absolute average difference between measurement and calculation of 1.2% for the 6 MV and 3.1% for the 10 MV beam with larger variations observed near the interfaces and in areas of high-dose gradient. The results presented here demonstrate that the convolution algorithm used in the Pinnacle treatment planning system produces accurate results in IMRT plans calculated and delivered to inhomogeneous media, even in regions that potentially lack electronic equilibrium.

61 RADIATION PROTECTION AND DOSIMETRY↗

ASIC Scoping Study Final Report

This report documents the results and findings of a one-year scoping study investigating multichannel readout application specific integrated circuits (ASICs) for interfacing to, and processing data from, silicon photomultiplier (SiPM) arrays. We document ASIC desired and required specifications for four applications supporting national security mission areas: neutron radiography, associated particle imaging, and two versions of kinematic neutron imaging cameras. While each application has a few unique requirements that stress capability, there is generally good agreement among most. Two recently developed ASIC devices were evaluated in a system-like configuration by interfacing these to scintillator crystals exposed to gamma and neutron sources. The 64-channel ORNL device delivered functional capability while meeting most mission requirements for neutron radiography. The Nalu Scientific device, a 32-channel full waveform digitizer, did not demonstrate reliable neutron / gamma separation but it is unclear if this was an ASIC issue or problems with test setup or firmware. A literature survey of other commercial and academic ASICs was undertaken to with the conclusion that existing devices do not meet all requirements.

42 ENGINEERING↗

Shock experiments and numerical simulations on low energy portable electrically exploding foil accelerators

Two low energy (1.6 and 8 kJ) portable electrically exploding foil accelerators are developed for moderately high pressure shock studies at small laboratory scale. Projectile velocities up to 4.0 km/s have been measured on Kapton flyers of thickness 125 {mu}m and diameter 8 mm, using an in-house developed Fabry-Perot velocimeter. An asymmetric tilt of typically few milliradians has been measured in flyers using fiber optic technique. High pressure impact experiments have been carried out on tantalum, and aluminum targets up to pressures of 27 and 18 GPa, respectively. Peak particle velocities at the target-glass interface as measured by Fabry-Perot velocimeter have been found in good agreement with the reported equation of state data. A one-dimensional hydrodynamic code based on realistic models of equation of state and electrical resistivity has been developed to numerically simulate the flyer velocity profiles. The developed numerical scheme is validated against experimental and simulation data reported in literature on such systems. Numerically computed flyer velocity profiles and final flyer velocities have been found in close agreement with the previously reported experimental results with a significant improvement over reported magnetohydrodynamic simulations. Numerical modeling of low energy systems reported here predicts flyer velocity profiles higher than experimental values, indicating possibility of further improvement to achieve higher shock pressures.

43 PARTICLE ACCELERATORS↗

Density functional theory for carbon dioxide crystal

We present a density functional approach to describe the solid−liquid phase transition, interfacial and crystal structure, and properties of polyatomic CO{sub 2}. Unlike previous phase field crystal model or density functional theory, which are derived from the second order direct correlation function, the present density functional approach is based on the fundamental measure theory for hard-sphere repulsion in solid. More importantly, the contributions of enthalpic interactions due to the dispersive attractions and of entropic interactions arising from the molecular architecture are integrated in the density functional model. Using the theoretical model, the predicted liquid and solid densities of CO{sub 2} at equilibrium triple point are in good agreement with the experimental values. Based on the structure of crystal-liquid interfaces in different planes, the corresponding interfacial tensions are predicted. Their respective accuracies need to be tested.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron and X-ray diffraction studies and cohesive interface model of fatigue crack deformation behavior

The crack-tip deformation behavior during a fatigue test with a single overload is studied using (1) neutron diffraction technique, from which both elastic lattice strain and dislocation densities are obtained, and (2) the finite element method that is based on an irreversible and hysteretic cohesive interface model. Neutron strain measurements and finite element simulations show a good qualitative agreement. The large plastic zone induced by the overload and the resulting compressive residual strains, are observed in front of the crack tip after the overload, are the principal reasons for the fatigue crack growth retardation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Molecular beam mass spectrometry measurements of vibrationally excited N 2 in the effluent of an atmospheric plasma jet: a comparison with a state-to-state kinetic model

Vibrationally excited N 2 molecules are suggested to be one of the possible key species responsible for the observed synergistic effects in plasma catalysis for NH 3 synthesis. To assess the impact of vibrationally excited species in plasma-catalysis, quantitative measurements near interfaces are required, which remains challenging. In this letter, we report spatially resolved measurements of vibrationally excited N 2 in the effluent of an atmospheric pressure plasma jet by molecular beam mass spectrometry (MBMS). The mass spectrometry signals as a function of electron energy of the ionizer were fitted with the effective electron-impact ionization cross section of N 2 (v) considering the vibrational distribution function as determined by a detailed vibrational level resolved plasma kinetic calculation. Here, the reported method presented in this letter shows the capability of MBMS to measure vibrationally excited species of N 2 near interfaces when the vibrational distribution function is known or assumed and shows excellent agreement with state-to-state kinetic models of N 2 (v).

42 ENGINEERING↗

GRACC: New generation of the OSG accounting

Throughout the last decade the Open Science Grid (OSG) has been fielding requests from user communities, resource owners, and funding agencies to provide information about utilization of OSG resources. Requested data include traditional accounting - core-hours utilized - as well as users certicate Distinguished Name, their affiliations, and eld of science. The OSG accounting service, Gratia, developed in 2006, is able to provide this information and much more. However, with the rapid expansion and transformation of the OSG resources and access to them, we are faced with several challenges in adapting and maintaining the current accounting service. The newest changes include, but are not limited to, acceptance of users from numerous university campuses, whose jobs are flocking to OSG resources, expansion into new types of resources (public and private clouds, allocation-based HPC resources, and GPU farms), migration to pilot-based systems, and migration to multicore environments. In order to have a scalable, sustainable and expandable accounting service for the next few years, we are embarking on the development of the next-generation OSG accounting service, GRACC, that will be based on open-source technology and will be compatible with the existing system. It will consist of swappable, independent components, such as Logstash, Elasticsearch, Grafana, and RabbitMQ, that communicate through a data exchange. GRACC will continue to interface EGI and XSEDE accounting services and provide information in accordance with existing agreements. Lastly, we will present the current architecture and working prototype.

97 MATHEMATICS AND COMPUTING↗

Numerical Study on Schramm-Loewner Evolution in Nonminimal Conformal Field Theories

The Schramm-Loewner evolution (SLE) is a powerful tool to describe fractal interfaces in 2D critical statistical systems, yet the application of SLE is well established for statistical systems described by quantum field theories satisfying only conformal invariance, the so-called minimal conformal field theories (CFTs). We consider interfaces in Z(N) spin models at their self-dual critical point for N=4 and N=5. These lattice models are described in the continuum limit by nonminimal CFTs where the role of a Z{sub N} symmetry, in addition to the conformal one, should be taken into account. We provide numerical results on the fractal dimension of the interfaces which are SLE candidates for nonminimal CFTs. Our results are in excellent agreement with some recent theoretical predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization and Modeling of 4H-SiC Lateral MOSFETs for Integrated Circuit Design

A new process in 4H-SiC is developed that features n-type buried and inversion channel lateral MOSFETs that are fabricated with several different channel lengths (2-8 mu m) and widths (8-32 mu m) and characterized over a wide temperature range (25 degrees C-225 degrees C). It is shown that the on-resistance of enhancement-mode SiC MOSFETs reduces with temperature despite a reduction in inversion mobility because of the interaction of interface states with temperature. To enable integrated circuit development using the developed MOSFETs, their electrical characteristics are modeled over geometry and temperature using the industry standard PSP MOSFET model. A new mathematical formulation to describe the presence of the interface states is also developed and implemented in the PSP model, and excellent agreement is shown between measurement and simulation using the modified PSP model.

Mudholkar, M↗

SU-F-T-672: A Novel Kernel-Based Dose Engine for KeV Photon Beams

Purpose: Mimicking state-of-the-art patient radiotherapy with high precision irradiators for small animals allows advanced dose-effect studies and radiobiological investigations. One example is the implementation of pre-clinical IMRT-like irradiations, which requires the development of inverse planning for keV photon beams. As a first step, we present a novel kernel-based dose calculation engine for keV x-rays with explicit consideration of energy and material dependencies. Methods: We follow a superposition-convolution approach adapted to keV x-rays, based on previously published work on micro-beam therapy. In small animal radiotherapy, we assume local energy deposition at the photon interaction point, since the electron ranges in tissue are of the same order of magnitude as the voxel size. This allows us to use photon-only kernel sets generated by MC simulations, which are pre-calculated for six energy windows and ten base materials. We validate our stand-alone dose engine against Geant4 MC simulations for various beam configurations in water, slab phantoms with bone and lung inserts, and on a mouse CT with (0.275mm)3 voxels. Results: We observe good agreement for all cases. For field sizes of 1mm{sup 2} to 1cm{sup 2} in water, the depth dose curves agree within 1% (mean), with the largest deviations in the first voxel (4%) and at depths>5cm (<2.5%). The out-of-field doses at 1cm depth agree within 8% (mean) for all but the smallest field size. In slab geometries, the mean agreement was within 3%, with maximum deviations of 8% at water-bone interfaces. The γ-index (1mm/1%) passing rate for a single-field mouse irradiation is 71%. Conclusion: The presented dose engine yields an accurate representation of keV-photon doses suitable for inverse treatment planning for IMRT. It has the potential to become a significantly faster yet sufficiently accurate alternative to full MC simulations. Further investigations will focus on energy sampling as well as calculation times. Research at ICR is also supported by Cancer Research UK under Programme C33589/A19727 and NHS funding to the NIHR Biomedical Research Centre at RMH and ICR. MFF is supported by Cancer Research UK under Programme C33589/A19908.

43 PARTICLE ACCELERATORS↗

Connecting LWRS Human Factor Engineering R&D to NUREG-0711 Elements and Modification Activities in Nuclear Power Plants

This Report documents the connection between DOE INL LWRS HFE R&D activities and the technical content of NUREG-0711 Results Summary Reports. Since the current and most recent LWRS HFE activities are associated with modernization and modification of nuclear power electric generating stations, this Report will limit its scope to these topics. NUREG-0711 Results Summary Reports content is shared with US nuclear generating stations by INL HFE staff through HFE Technical Reports to identify potential HEDs with planned upgrades. With such information, utilities have confidence that their upgraded HMIs, operating procedures, conduct of operations, and training with the upgraded systems will ensure their continued safe control of the nuclear plant. The utilities use the HFE Technical Reports as basis documents in their licensing processes used to modify the plant (LAR or 10CFR50.59). For plant modifications, LWRS HFE R&D activities commence as early as an agreement is reached between the utility and the LWRS Program staff. The multiple interfaces usually result in the two organizations meeting at INL, at the utility’s site, and at the vendor’s facility. Since there generally is a shortage of utility based HFE experience, INL HFE staff supports the HFE related utility modernization & modification (obsolescence) activities whenever requested.

10 CFR 50.59↗

Vortex paradigm for shock-accelerated density-stratified interfaces

Numerical simulations are reported that capture the observations of Haas and Sturtevant (1985) when a planar shock accelerates an inclined planar interface between two media. A vortex paradigm is presented for interpreting the evolution of shock-accelerated density-stratified interfaces beyond early times. The simulations illustrate the paradigm and are in good agreement with the results of Haas and Sturtevant. Color images of space-time diagrams of the one-space integrated vorticity function are given to show the primary and secondary features of the emerging vortex structures.

Hawley, John F.↗

Natural and thermocapillary convection in multiple liquid layers

A numerical and experimental investigation is conducted of the fluid dynamics of immiscible liquid layers, as encountered in the liquid encapsulation of electronic melts. Attention is given to the convective flow in multiple liquid layers that are driven by temperature gradients that are either parallel or perpendicular to the liquid/liquid interfaces. The experimental and theoretical results obtained are noted not to be in agreement for differential side-heating of a three-layer system.

Prakash, A.↗

Performance of a Ka-band transponder breadboard for deep-space applications

This article summarizes the design concepts applied in the development of and advanced Ka-band (34.4 GHz/32 GHz) transponder breadboard for the next generation of space communications systems applications. The selected architecture upgrades the X-band (7.2 GHz/8.4 GHz) deep-space transponder (DST) to provide Da-band up/Ka- and X-band down capability. The Ka-band transponder breadboard incorporates several state-of-the-art components, including sampling mixers, a Ka-band dielectric resonator oscillator, and microwave monolithic integrated circuits (MMICs). The MMICs that were tested in the breadboard include upconverters, downconverters, automatic gain control circuits, mixers, phase modulators, and amplifiers. The measured receiver dynamic range, tracking range, acquisition rate, static phase error, and phase jitter characteristics of the Ka-band breadboard interfaced to the advanced engineering model X-band DST are in good agreement with the expected performance. The results show a receiver tracking threshold of -149 dBm with a dynamic range of 80 dB and a downlink phase jitter of 7 deg rms. The analytical results of phase noise and Allan standard deviation are in good agreement with the experimental results.

Mysoor, N. R.↗

Definition of the Spatial Resolution of X-Ray Microanalysis in Thin Foils

The spatial resolution of X-ray microanalysis in thin foils is defined in terms of the incident electron beam diameter and the average beam broadening. The beam diameter is defined as the full width tenth maximum of a Gaussian intensity distribution. The spatial resolution is calculated by a convolution of the beam diameter and the average beam broadening. This definition of the spatial resolution can be related simply to experimental measurements of composition profiles across interphase interfaces. Monte Carlo calculations using a high-speed parallel supercomputer show good agreement with this definition of the spatial resolution and calculations based on this definition. The agreement is good over a range of specimen thicknesses and atomic number, but is poor when excessive beam tailing distorts the assumed Gaussian electron intensity distributions. Beam tailing occurs in low-Z materials because of fast secondary electrons and in high-Z materials because of plural scattering.

Williams, D. B.↗

Bridgman Growth of Germanium Crystals in a Rotating Magnetic Field

A series of (100)-oriented gallium-doped germanium crystals have been grown by the Bridgman method and under the influence of a rotating magnetic field (RMF). Time-dependent flow instabilities occur when the critical magnetic Taylor number (Tm(sup c) is exceeded, and this can be observed by noting the appearance of striations in the grown crystals. The experimental data indicate that Tm(sup c) increases as the aspect ratio of the melt decreases. Modeling calculations predicting Tm(sup c) as a function of aspect ratio are in reasonable agreement with the experimental data. The RMF has a marked affect on the interface shape, changing it from concave to nearly flat as the RMF strength is increased. Also, by pulsing the RMF on and off, it is shown that intentional interface demarcations can be introduced.

Volz, M. P.↗

Damage Simulation in Non-Crimp Fabric Composite Plates Subjected to Impact Loads

Progressive failure analysis (PFA) of non-crimp fabric (NCF) composite laminates subjected to low velocity impact loads was performed using the COmplete STress Reduction (COSTR) damage model implemented through VUMAT and UMAT41 user subroutines in the frame works of the commercial finite element programs ABAQUS/Explicit and LS-DYNA, respectively. To validate the model, low velocity experiments were conducted and detailed correlations between the predictions and measurements for both intra-laminar and inter-laminar failures were made. The developed material and damage model predicts the peak impact load and duration very close with the experimental results. Also, the simulation results of delamination damage between the ply interfaces, in-plane matrix damages and fiber damages were all in good agreement with the measurements from the non-destructive evaluation data.

Satyanarayana, Arunkumar↗