Search NASA⌕ Search

SEARCH · Search NASA

Results for “ion trap”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Latitudinal plasma distribution in the dusk plasmaspheric bulge - Refilling phase and quasi-equilibrium state

Very low-energy trapped ions, mostly protons, have been observed in a region of moderate density characteristic of the plasmapause boundary and of the plasmaspheric bulge. The present paper is concerned with an examination of the latitudinal structure of the bulge under quasi-steady conditions and the conditions of the recovery phase. Details regarding the data base are considered along with observations of the morphology and dynamics of the bulge, the latitudinal density distribution in the expanded bulge, the convection scenario during the replenishment phase, and latitudinal effects on plasma characteristics during plasmasphere refilling. The data utilized have been mainly provided by the DE 1 and GEOS 2 spacecraft traveling in two perpendicular planes. It is found that the bulge is a dynamic region, where no reasonable interpretation of the observed density distribution can be achieved without taking into account the mechanism of magnetospheric convection.

Decreau, P. M. E.↗

Monitoring of space station life support systems with miniature mass spectrometry and artificial intelligence

The combination of quadrupole ion trap tandem mass spectroscopy with artificial intelligence is a promising approach for monitoring the performance of the life support systems in the space station. Such an analytical system can provide the selectivity, sensitivity, speed, small size, and decision making intelligence to detect, identify, and quantify trace toxic compounds which may accumulate in the space station habitat.

Yost, Richard A.↗

Lignin Sensor Based On Flash-Pyrolysis Mass Spectrometry

New lignin sensor takes only few minutes to measure lignin content of specimen of wood, pulp, paper, or similar material. Includes flash pyrolizer and ion-trap detector that acts as mass spectrometer. Apparatus measures amount of molecular fragments of lignin in pyrolysis products of samples. Helpful in controlling digestors in paper mills to maintain required lignin content, and also in bleaching plants, where good control of bleaching becomes possible if quick determination of lignin content made.

Kwack, Eug Y.↗

Ion microprobe elemental analyses of impact features on interplanetary dust experiment sensor surfaces

Hypervelocity impact features on several of the electro-active dust sensors utilized in the Interplanetary Dust Experiment (IDE) were subjected to elemental analysis using an ion microprobe. The negatively biased dust sensor surfaces acted as ion traps for cations produced in the plasma plumes of impacting particles. Impactor residue surrounds most impact features to two or three feature diameters. After etching away a layer of carbonaceous/silicaceous surface contamination, low mass resolution elemental survey scans are used to tentatively identify the presence of impactor debris. High mass resolution two-dimensional elemental maps and three dimensional depth profiling of the feature and surrounding area show the distribution and relative composition of the debris. The location of these sensors on the six primary Long Duration Exposure Facility (LDEF) sides provides a unique opportunity to further define the debris environment. Researchers applied the same techniques to impact and contaminant features on a set of ultra-pure, highly polished single crystal germanium wafer witness plates that were mounted on row 12 and exposed to the environment during the entire mission.

Hunter, Jerry L.↗

Keynote address: The past, present, and future of atomic time

The early history of atomic time and frequency standards is reviewed. The most accurate and stable present standards are described. Prospective future improvements are discussed, particularly those with laser cooling and with trapped ions and atoms.

Ramsey, Norman F.↗

Proceedings of the 23rd Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

A compilation of technical papers, from the 23rd annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting, is presented. Papers were given in the following categories: (1) developments in rubidium, cesium, and hydrogen-based frequency standards, and in cryogenic and trapped-ion technology; (2) international and transnational applications of PTTI technology with emphasis on satellite laser tracking networks, GLONASS timing, comparison of national time scales and international communications; (3) applications of PTTI technology to the telecommunications, power distribution, platform positioning, and geophysical survey industries; (4) applications of PTTI technology to evolving military communications and navigation systems; and (5) dissemination of precise time and frequency by means of GPS, GLONASS, MILSTAR, Loran, and synchronous communications satellites.

Richard L. Sydnor↗

Transition probabilities for the 3s2 3p(2P0)-3s3p2(4P) intersystem lines of Si II

Intensity ratios of lines of the spin-changing 'intersystem' multiplet of S II (4P yields 2P0) at 234 nm have been used to determine electron densities and temperatures in a variety of astrophysical environments. However, the accuracy of these diagnostic calculations have been limited by uncertainties associated with the available atomic data. We report the first laboratory measurement, using an ion-trapping technique, of the radiative lifetimes of the three metastable levels of the 3s3p2 4P term of Si II. Our results are 104 +/- 16, 406 +/- 33, and 811 +/- 77 micro-s for lifetimes of the J = 1/2, 5/2, and 3/2 levels, respectively. A-values were derived from our lifetimes by use of measured branching fractions. Our A-values, which differ from calculated values by 30 percent or more, should give better agreement between modeled and observed Si II line ratios.

Calamai, Anthony G.↗

The 24th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

A compilation of technical papers presented at the 24th Precise Time and Time Interval (PTTI) Applications and Planning Meeting held in Dec. 1992 is presented. Papers are in the following categories: recent developments in rubidium, cesium, and hydrogen-based frequency standards, and in cryogenic and trapped-ion technology; international and transnational applications of PTTI technology with emphasis on satellite laser tracking networks, GLONASS timing, intercomparison of national time scales, and international telecommunications; applications of PTTI technology to the telecommunications, power distribution, and platform positioning, and geophysical survey industries; applications of PTTI technology to evolving military communications and navigation systems; and dissemination of precise time and frequency by means of GPS, GLONASS, MILSTAR, Loran, and synchronous communications satellites.

Sydnor, Richard L.↗

Time scale algorithms for an inhomogeneous group of atomic clocks

Through the past 17 years, the time scale requirements at the National Research Council (NRC) have been met by the unsteered output of its primary laboratory cesium clocks, supplemented by hydrogen masers when short-term stability better than 2 x 10(exp -12)tau(sup -1/2) has been required. NRC now operates three primary laboratory cesium clocks, three hydrogen masers, and two commercial cesium clocks. NRC has been using ensemble averages for internal purposes for the past several years, and has a realtime algorithm operating on the outputs of its high-resolution (2 x 10(exp -13) s at 1 s) phase comparators. The slow frequency drift of the hydrogen masers has presented difficulties in incorporating their short-term stability into the ensemble average, while retaining the long-term stability of the laboratory cesium frequency standards. We report on this work on algorithms for an inhomogeneous ensemble of atomic clocks, and on our initial work on time scale algorithms that could incorporate frequency calibrations at NRC from the next generation of Zacharias fountain cesium frequency standards having frequency accuracies that might surpass 10(exp -15), or from single-trapped-ion frequency standards (Ba+, Sr+,...) with even higher potential accuracies. The requirements for redundancy in all the elements (including the algorithms) of an inhomogeneous ensemble that would give a robust real-time output of the algorithms are presented and discussed.

Jacques, C.↗

The 25th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

Papers in the following categories are presented: recent developments in rubidium, cesium, and hydrogen-based frequency standards, and in cryogenic and trapped-ion technology; international and transnational applications of precise time and time interval (PTTI) technology with emphasis on satellite laser tracking networks, GLONASS timing, intercomparison of national time scales and international telecommunication; applications of PTTI technology to the telecommunications, power distribution, platform positioning, and geophysical survey industries; application of PTTI technology to evolving military communications and navigation systems; and dissemination of precise time and frequency by means of GPS, GLONASS, MILSTAR, LORAN, and synchronous communications satellites.

Sydnor, Richard L.↗

Frequency standards from industry over the next 25 years

Present and possible future performance for many of the existing and new commercial frequency standards is presented here. Recent progress in the gas cell atomic standards with regards to size and cost is significant and considerable improvement is expected. Cesium beam standards will benefit in stability and accuracy from optical pumping. Cooled hydrogen masers will offer extremely good stability. Advances in trapped ion and cesium fountain technologies make them good high performance candidates for the future. The quartz oscillator field is more mature and consequently performance improvements for the future are going to be less spectacular. Oscillators stabilized to GPS will have many applications. Recent performance of cooled microwave dielectric resonator oscillators is very good and they offer the promise of serving as flywheel oscillators for advanced performance atomic standards.

Cutler, Leonard S.↗

SAMPEX special pointing mode

A new pointing mode has been developed for the Solar, Anomalous, and Magnetospheric Particle Explorer (SAMPEX) spacecraft. This pointing mode orients the instrument boresights perpendicular to the field lines of the Earth's magnetic field in regions of low field strength and parallel to the field lines in regions of high field strength, to allow better characterization of heavy ions trapped by the field. The new mode uses magnetometer signals and is algorithmically simpler than the previous control mode, but it requires increased momentum wheel activity. It was conceived, designed, tested, coded, uplinked to the spacecraft, and activated in less than seven months.

Markley, F. Landis↗

The 26th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

This document is a compilation of technical papers presented at the 26th Annual PTTI Applications and Planning Meeting. Papers are in the following categories: (1) Recent developments in rubidium, cesium, and hydrogen-based frequency standards, and in cryogenic and trapped-ion technology; (2) International and transnational applications of Precise Time and Time Interval technology with emphasis on satellite laser tracking, GLONASS timing, intercomparison of national time scales and international telecommunications; (3) Applications of Precise Time and Time Interval technology to the telecommunications, power distribution, platform positioning, and geophysical survey industries; (4) Applications of PTTI technology to evolving military communications and navigation systems; and (5) Dissemination of precise time and frequency by means of GPS, GLONASS, MILSTAR, LORAN, and synchronous communications satellites.

Sydnor, Richard↗

Middle- and low-latitude emissions from energetic neutral atom precipitation seen from ATLAS 1 under quiet magnetic conditions

During the ATLAS 1 mission spectral observations were made at middle and low latitudes of features expected from the precipitation of energetic neutral atoms. The Imaging Spectrometric Observatory was used at night in the UV and visible with maximum gain. The tangent ray heights of the look directions ranged from near 100 km to near 200 km, and the geomagnetic conditions were quiet during the observations, which were made March 28 to April 3, 1992. The N2(+) 1N 391.4-nm and O I 130.4 and 135.6-nm emissions were observed at all latitudes, with lower emission rates at lower magnetic dip latitudes, except that enhancements in the O I lines were seen within 30 deg of the dip equator to radiative recombination of ionospheric plasma. The latitude profile observed for the N2(+) 1N emission did not show an equatorial or midlatitude peak. This implies that the source of energetic neutrals is more consistent with prompt charge exchange loss of freshly injected trapped ions with relatively low mirror heights (i.e., ions on higher L shells with equatorial pitch angle distributions nearly isotropic to the loss cone) than loss of highly eroded populations of particles with high mirror heights (i.e., ions on lower L shells with pancake equatorial pitch angle distributions). The N2(+) 1N emission rates have been compared with models of atmospheric emission due to fluxes of O/O(+) and H/H(+) in the thermosphere, as produced by energetic neutral oxygen or hydrogen atom precipitation. Energy deposition rates are inferred.

Tinsley, B. A.↗

STS-76 Flight Day 1

On this first day of the STS-76 mission, the flight crew, Cmdr. Kevin P. Chilton, Pilot Richard A Searfoss, and Mission Specialists Shannon W. Lucid, Linda M. Godwin, Michael R. Clifford, and Ronald M. Sega, are shown performing prelaunch and launch activities for the night launch of the Space Shuttle Atlantis. The primary objective of this mission is the third docking between the Mir Space Station and Atlantis and a crew transfer. Lucid will remain onboard the Mir for about four months. Other activities include an EVA by Godwin and Clifford, logistics operations, and scientific research with a SPACEHAB module, some middeck experiments, and a Get Away Special (GAS) canister. Also, almost a ton of equipment and supplies will be transferred to the Mir. Experiments include the Mir Electric Field Characterization (MEFC), European Space Agency (ESA) Biorack life sciences experiment, Queens University Experiment in Liquid Diffusion (QUELD), Optizone Liquid Phase Sintering Experiment (OLIPSE), and a Naval Research Laboratory (NRL) GAS payload Trapped Ions in Space (TRIS), which will measure low-energy particle radiation in the inner magnetosphere. This mission also will include a KidSat, a prototype of Earth viewing cameras and instruments, that allow students in grades K-12 to see and direct the capture of pictures from space. Footage from Mission control is also included.

Source record↗

Magnetospheric space plasma investigations

The discussion in this final report is limited to a summary of important accomplishments. These accomplishments include the generalized semikinetic (GSK) model, O(+) outflows in the F-region ionosphere, field-aligned flows and trapped ion distributions, ULF wave ray-tracing, and plasmasphere-ionosphere coupling.

Comfort, Richard H.↗

27th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

This document is a compilation of technical papers presented at the 27th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting, held November 29 - December 1, 1995 at San Diego, CA. Papers are in the following categories: Recent developments in rubidium, cesium, and hydrogen-based frequency standards; and in cryogenic and trapped-ion technology; International and transnational applications of PTTI technology with emphasis on satellite laser tracking, GLONASS timing, intercomparison of national time scales and international telecommunications; Applications of PTTI technology to the telecommunications, power distribution, platform positioning, and geophysical survey industries; Applications of PTTI technology to evolving military communications and navigation systems; and Dissemination of precise time and frequency by means of Global Positioning System (GPS), Global Satellite Navigation System (GLONASS), MILSTAR, LORAN, and synchronous communications satellites.

Sydnor, Richard L.↗