Search NASA⌕ Search

SEARCH · Search NASA

Results for “langley”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Exploratory study to induce fan noise in the test section of the NASA Langley full-scale wind tunnel

Measures to reduce the intensity of fan noise in the NASA Langley 30 ft x 60 ft subsonic wind tunnel were sought. Measurements were first performed to document existing aerodynamic and acoustic conditions. The purpose of these experiments was to (1) obtain the transfer function between the sound power output of the fan and the sound pressure on the test platform, (2) evaluate the sound attenuation around the tunnel circuit, (3) measure simultaneously the flow profile and the turbulence spectrum of the inflow to the fan and the noise on the test platform, and (4) perform flow observations and identify secondary noise sources. Subsequently, these data were used to predict (1) the relative contribution of the major aerodynamic parameters to total fan noise and (2) the effect of placing a dissipative silencer in the collector duct upstream of the fan. Promising noise control measures were identified and recommendations were made on how to evaluate them.

Ver, I. L.↗

Publications in acoustics and noise control from the NASA Langley Research Center during 1940 - 1974

This document contains reference lists of published Langley Research Center papers in various areas of acoustics and noise control for the period 1940-1974. The research work was performed either in-house by the center staff or by other personnel supported entirely or in part by grants or contracts. The references are listed chronologically and are grouped under the following general headings: (1) Duct acoustics, (2) Propagation and operations, (3) Rotating blade noise, (4) Jet noise, (5) Sonic boom, (6) Flow-surface interaction noise, (7) Human response, and (8) Structural response.

Smith, G. C.↗

Recent progress on new facilities at the NASA Langley Research Center

A new fan-driven high Reynolds number transonic cryogenic tunnel the National Transonic Facility is being planned for the United States. This tunnel will provide an order of magnitude increase in Reynolds number capability over existing tunnels. Theoretical studies and experience with the Langley 1/3 Meter Transonic Cryogenic Tunnel indicate that the cryogenic concept allows the attainment of full-scale Reynolds number at reasonable levels of dynamic pressure. The unique modes of operation which are available only in a cryogenic tunnel make possible the separation of Mach number, Reynolds number possible the separation of Mach number, Reynolds number, and aeroelastic effects. By reducing the drive power requirements to a level where a conventional fan drive system may be used, the cryogenic concept makes possible a tunnel with high productivity and run times sufficiently long to allow for all types of tests at reduced capital costs and, reduced total energy consumption.

Kilgore, R. A.↗

Comparisons of flight measurements with predictions from aeroelastic models in the NASA Langley Transonic Dynamics Tunnel

The NASA Langley Transonic Dynamics Tunnel, which has a variable density Freon-12 (or air) test medium, was designed for the study of dynamics and aeroelastic problems of aerospace vehicles. During the 15 years of operation of this facility there have been various opportunities to compare wind tunnel and flight test results. Some of these opportunities arise from routine flight checks of the prototype, others from carefully designed comparative wind tunnel and flight experiments. Data obtained from various sources is presented. The topics covered are: gust and buffet response, control surface effectiveness, flutter, and active control of aeroelastic effects. Some benefits and shortcomings of Freon-12 as a test medium are also discussed. Although areas of uncertainly are evident and there is a continuing need for improvements in model simulation and testing techniques, the results indicate that predictions from aeroelastic model tests are, in general, substantiated by full scale flight tests.

Reed, W. H., III↗

Review of drag cleanup tests in Langley full-scale tunnel (from 1935 to 1945) applicable to current general aviation airplanes

Results of drag cleanup tests conducted in the Langley full-scale tunnel during the period from 1935 to 1945 are summarized for potential application to current propeller-driven general aviation airplanes. Data from tests on 23 airplanes indicate that the drag increments produced by many individual configuration features - such as, power plant installation, air leakage, cockpit canopies, control surface gaps, and antenna installations - are not large; however, when the increments are summed, the resulting total drag increase is significant. On the basis of results of the investigation, it appears that considerable reduction in drag can be obtained by proper attention to details in aerodynamic design and by adherence to the guidelines discussed.

Coe, P. L., Jr.↗

Aeroheating (pressure) characteristics on a 0.10-scale version of the vehicle 3 space shuttle configuration (26-OTS) in the Langley Research Center 4-foot wind tunnel (IH4)

Results of wind tunnel tests, conducted at the Langley Research Center Unitary Plan Wind Tunnel, are presented. The model tested was an 0.010-scale version of the Vehicle 3 Space Shuttle Configuration. Pressure measurements were made on the launch configuration, Orbiter alone, external tank alone, and solid rocket booster alone, to provide heat transfer pressure data. The tests were conducted for a Mach number range from 2.36 to 4.6 and Reynolds number range from 1.2 to 5 million per foot. The model was tested at angles of attack from -10 to 20 deg for a sideslip angle range from -5 to +5 deg, and at sideslip angles from -5 to 48 deg for 0 deg angle of attack. Tabulated data are given and photographs of the test configuration are shown.

Kingsland, R. B.↗

Feasibility of making sound power measurements in the NASA Langley V/STOL tunnel test section

Based on exploratory acoustic measurements in Langley's V/STOL wind tunnel, recommendations are made on the methodology for making sound power measurements of aircraft components in the closed tunnel test section. During airflow, tunnel self-noise and microphone flow-induced noise place restrictions on the amplitude and spectrum of the sound source to be measured. Models of aircraft components with high sound level sources, such as thrust engines and powered lift systems, seem likely candidates for acoustic testing.

Brooks, T. F.↗

Low-subsonic stability and control characteristics of a 0.015-scale remotely controlled elevon model (44-0) of the space shuttle orbiter in the Langley Research Center low turbulence pressure tunnel (LA61B)

A Langley-built 0.015-scale SSV orbiter configuration with remote independently operated left and right elevon surfaces was tested in the NASA/Langley Research Center Low Turbulence Pressure Tunnel. A detailed aerodynamic data base was obtained for the current shuttle orbiter configuration. Special attention was directed to definition of Reynolds number effects on nonlinear aerodynamic characteristics of the orbiter. Small increments in angle of attack, sideslip, and elevon/aileron position were studied in order to better define areas where nonlinearities may occur. Force and moment, and elevon position data were recorded over an angle of attack range -2 deg to 20 deg at angles of sideslip of 0 deg , + or - 2 deg, and + or - 4 deg. Tests were also made over an angle of sideslip range of -6 deg to 6 deg at selected angles of attack and elevon/aileron position. The test Mach numbers were from 0.15 to 0.30 at Reynolds numbers from 2.0 to 13.5 million per foot.

Source record↗

The Langley thermal protection system test facility: A description including design operating boundaries

A description of the Langley thermal protection system test facility is presented. This facility was designed to provide realistic environments and times for testing thermal protection systems proposed for use on high speed vehicles such as the space shuttle. Products from the combustion of methane-air-oxygen mixtures, having a maximum total enthalpy of 10.3 MJ/kg, are used as a test medium. Test panels with maximum dimensions of 61 cm x 91.4 cm are mounted in the side wall of the test region. Static pressures in the test region can range from .005 to .1 atm and calculated equilibrium temperatures of test panels range from 700 K to 1700 K. Test times can be as long as 1800 sec. Some experimental data obtained while using combustion products of methane-air mixtures are compared with theory, and calibration of the facility is being continued to verify calculated values of parameters which are within the design operating boundaries.

Klich, G. F.↗

Acoustical Evaluation of the NASA Langley V/STOL Wind Tunnel

The results are presented of the acoustical measurements made to supply NASA Langley operating personnel with the acoustical characteristics of the tunnel test section needed for the planning of acoustical measurements and to identify the major noise sources. The results of the preliminary measurements of the spatial distribution of the sound field in the closed tunnel configuration indicate that the total sound power output of an unknown sound source placed in the test section could most probably be evaluated by measuring the sound pressure in two properly chosen locations in the duct - one upstream and one downstream of the test section. However, it is recommended that the practicability of this method of sound power output measurements be further investigated, preferably in a small scale model of the V/STOL Tunnel.

Ver, I. L.↗

Design features and operational characteristics of the Langley 0.3-meter transonic cryogenic tunnel

Experience with the Langley 0.3 meter transonic cryogenic tunnel, which is fan driven, indicated that such a tunnel presents no unusual design difficulties and is simple to operate. Purging, cooldown, and warmup times were acceptable and were predicted with good accuracy. Cooling with liquid nitrogen was practical over a wide range of operating conditions at power levels required for transonic testing, and good temperature distributions were obtained by using a simple liquid nitrogen injection system. To take full advantage of the unique Reynolds number capabilities of the 0.3 meter transonic tunnel, it was designed to accommodate test sections other than the original, octagonal, three dimensional test section. A 20- by 60-cm two dimensional test section was recently installed and is being calibrated. A two dimensional test section with self-streamlining walls and a test section incorporating a magnetic suspension and balance system are being considered.

Kilgore, R. A.↗

Mated aerodynamic characteristics investigation for the 0.04 scale model TE 1065 (Boeing 747-100) of the 747 CAM and the 0.0405 scale model (43-0) of the space shuttle orbiter in the NASA Langley V/STOL transition research wind tunnel (CA8), volume 1

Aerodynamic force data are presented in tables and graphs for the NASA Langley V/STOL Transition Research Wind Tunnel tests on a 0.04 scale model of the 747 with a 0.0405 scale Orbiter space shuttle. The investigation included the effects of flap setting, stabilizer angle, elevator angle, ground proximity, and Orbiter tailcone fairing. Data were obtained in the pitch plane only. The test was run at M = 0.15, with a dynamic pressure of 35 psf. Six static pressures were measured on each side of the 747 CAM nose to determine the effects of the Orbiter on the 747 airspeed and altitude indicators.

Source record↗

Description and operating performance of a parallel-rail electric-arc system with helium driver gas for the Langley 6-inch expansion tube

A parallel-rail arc-discharge system to heat and pressurize the initial helium driver gas of the Langley 6-inch expansion tube is described. This system was designed for a 2.44-m-long driver vessel rated at 138 MPa, with a distance between rails of 20.3 cm. Electric energy was obtained from a capacitor storage system rated at 12,000 V with a maximum energy of 5 MJ. Tests were performed over a range of energy from 1.74 MJ to the maximum value. The operating experience and system performance are discussed, along with results from a limited number of expansion-tube tests with air and carbon dioxide as test gases.

Moore, J. A.↗

Structural mechanics research at the Langley Research Center

The contributions of NASA's Langley Research Center in areas of structural mechanics were traced from its NACA origins in 1917 to the present. The developments in structural mechanics technology since 1940 were emphasized. A brief review of some current research topics were discussed as well as anticipated near-term research projects.

Stephens, W. B.↗

Correlation with flight of some aeroelastic model studies in the NASA Langley transonic dynamics tunnel

The NASA Langley transonic dynamics tunnel, which has a variable density Freon-12 (or air) test medium, was designed specifically for the study of dynamics and aeroelastic problems of aerospace vehicles. During the 15 years of operation of this facility, there have been various opportunities to compare wind tunnel and flight test results. Some of these opportunities arise from routine flight checks of the prototypes; others, from carefully designed comparative wind-tunnel and flight experiments. Such data obtained from various published and unpublished sources are presented. The topics covered are: gust and buffet response, control surface effectiveness, flutter, and active control of aeroelastic effects. Some benefits and shortcomings of Freon-12 as a test medium are also discussed. Although areas of uncertainty are evident and there is a continuing need for improvements in model simulation and testing techniques, the results presented indicate that predictions from aeroelastic model tests are, in general, substantiated by full scale flight tests.

Reed, W. H., III↗

Evaluation of initial collector field performance at the Langley Solar Building Test Facility

The thermal performance of the solar collector field for the NASA Langley Solar Building Test Facility is given for October 1976 through January 1977. A 1,180 square meter solar collector field with seven collector designs helped to provide hot water for the building heating system and absorption air conditioner. The collectors were arranged in 12 rows with nominally 51 collectors per row. Heat transfer rates for each row were calculated and recorded along with sensor, insolation, and weather data every five minutes using a minicomputer. The agreement between the experimental and predicted collector efficiencies was generally within five percentage points.

Boyle, R. J.↗

Holographic flow visualization at the Langley CF4 tunnel

A holographic flow visualization system was used to obtain shadowgraph, schlieren, and interferograms of the flow field at Langley's hypersonic (Mach 6) CF4 tunnel. The dual hologram technique which was used makes it possible to vary focusing, knife-edge position, and the orientation and spacing of the interference fringes after a tunnel run. The experimental arrangement necessary to produce high quality interferograms is discussed. Typical shadowgraphs, schlieren pictures, and interferograms are presented.

Burner, A. W.↗

NASA Langley Research Center outreach in astronautical education

The Langley Research Center has traditionally maintained an active relationship with the academic community, especially at the graduate level, to promote the Center's research program and to make graduate education available to its staff. Two new institutes at the Center - the Joint Institute for Acoustics and Flight Sciences, and the Institute for Computer Applications - are discussed. Both provide for research activity at the Center by university faculties. The American Society of Engineering Education Summer Faculty Fellowship Program and the NASA-NRC Postdoctoral Resident Research Associateship Program are also discussed.

Duberg, J. E.↗