Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Shared aperture antenna array

A shared aperture antenna array including an array of antennas is disclosed. Elements of neighboring antennas are shared to create additional antennas. The shared elements include radiating patches and apertures. Each antenna shares an aperture with neighboring antennas. The array of antennas may be linear or two-dimensional. A phase shifting network with single-pole-single-throw reflective switches may be coupled to the antennas.

Tedeschi, Jonathan R.↗

SU-F-T-458: Tracking Trends of TG-142 Parameters Via Analysis of Data Recorded by 2D Chamber Array

Purpose: With increasing QA demands of medical physicists in clinical radiation oncology, the need for an effective method of tracking clinical data has become paramount. A tool was produced which scans through data automatically recorded by a 2D chamber array and extracts relevant information recommended by TG-142. Using this extracted information a timely and comprehensive analysis of QA parameters can be easily performed enabling efficient monthly checks on multiple linear accelerators simultaneously. Methods: A PTW STARCHECK chamber array was used to record several months of beam outputs from two Varian 2100 series linear accelerators and a Varian NovalisTx−. In conjunction with the chamber array, a beam quality phantom was used to simultaneously to determine beam quality. A minimalist GUI was created in MatLab that allows a user to set the file path of the data for each modality to be analyzed. These file paths are recorded to a MatLab structure and then subsequently accessed by a script written in Python (version 3.5.1) which then extracts values required to perform monthly checks as outlined by recommendations from TG-142. The script incorporates calculations to determine if the values recorded by the chamber array fall within an acceptable threshold. Results: Values obtained by the script are written to a spreadsheet where results can be easily viewed and annotated with a “pass” or “fail” and saved for further analysis. In addition to creating a new scheme for reviewing monthly checks, this application allows for able to succinctly store data for follow up analysis. Conclusion: By utilizing this tool, parameters recommended by TG-142 for multiple linear accelerators can be rapidly obtained and analyzed which can be used for evaluation of monthly checks.

61 RADIATION PROTECTION AND DOSIMETRY↗

Characterization of responses of 2d array seven29 detector and its combined use with octavius phantom for the patient-specific quality assurance in rapidarc treatment delivery

A commercial 2D array seven29 detector has been characterized and its performance has been evaluated. 2D array ionization chamber equipped with 729 ionization chambers uniformly arranged in a 27 Multiplication-Sign 27 matrix with an active area of 27 Multiplication-Sign 27 cm{sup 2} was used for the study. An octagon-shaped phantom (Octavius Phantom) with a central cavity is used to insert the 2D ion chamber array. All measurements were done with a linear accelerator. The detector dose linearity, reproducibility, output factors, dose rate, source to surface distance (SSD), and directional dependency has been studied. The performance of the 2D array, when measuring clinical dose maps, was also investigated. For pretreatment quality assurance, 10 different RapidArc plans conforming to the clinical standards were selected. The 2D array demonstrates an excellent short-term output reproducibility. The long-term reproducibility was found to be within {+-}1% over a period of 5 months. Output factor measurements for the central chamber of the array showed no considerable deviation from ion chamber measurements. We found that the 2D array exhibits directional dependency for static fields. Measurement of beam profiles and wedge-modulated fields with the 2D array matched very well with the ion chamber measurements in the water phantom. The study shows that 2D array seven29 is a reliable and accurate dosimeter and a useful tool for quality assurance. The combination of the 2D array with the Octavius phantom proved to be a fast and reliable method for pretreatment verification of rotational treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Performance parameters of a liquid filled ionization chamber array

Purpose: In this work, the properties of the two-dimensional liquid filled ionization chamber array Octavius 1000SRS (PTW-Freiburg, Germany) for use in clinical photon-beam dosimetry are investigated.Methods: Measurements were carried out at an Elekta Synergy and Siemens Primus accelerator. For measurements of stability, linearity, and saturation effects of the 1000SRS array a Semiflex 31013 ionization chamber (PTW-Freiburg, Germany) was used as a reference. The effective point of measurement was determined by TPR measurements of the array in comparison with a Roos chamber (type 31004, PTW-Freiburg, Germany). The response of the array with varying field size and depth of measurement was evaluated using a Semiflex 31010 ionization chamber as a reference. Output factor measurements were carried out with a Semiflex 31010 ionization chamber, a diode (type 60012, PTW-Freiburg, Germany), and the detector array under investigation. The dose response function for a single detector of the array was determined by measuring 1 cm wide slit-beam dose profiles and comparing them against diode-measured profiles. Theoretical aspects of the low pass properties and of the sampling frequency of the detector array were evaluated. Dose profiles measured with the array and the diode detector were compared, and an intensity modulated radiation therapy (IMRT) field was verified using the Gamma-Index method and the visualization of line dose profiles.Results: The array showed a short and long term stability better than 0.1% and 0.2%, respectively. Fluctuations in linearity were found to be within ±0.2% for the vendor specified dose range. Saturation effects were found to be similar to those reported in other studies for liquid-filled ionization chambers. The detector's relative response varied with field size and depth of measurement, showing a small energy dependence accounting for maximum signal deviations of ±2.6% from the reference condition for the setup used. The σ-values of the Gaussian dose response function for a single detector of the array were found to be (0.72 ± 0.25) mm at 6 MV and (0.74 ± 0.25) mm at 15 MV and the corresponding low pass cutoff frequencies are 0.22 and 0.21 mm{sup −1}, respectively. For the inner 5 × 5 cm{sup 2} region and the outer 11 × 11 cm{sup 2} region of the array the Nyquist theorem is fulfilled for maximum sampling frequencies of 0.2 and 0.1 mm{sup −1}, respectively. An IMRT field verification with a Gamma-Index analysis yielded a passing rate of 95.2% for a 3 mm/3% criterion with a TPS calculation as reference.Conclusions: This study shows the applicability of the Octavius 1000SRS in modern dosimetry. Output factor and dose profile measurements illustrated the applicability of the array in small field and stereotactic dosimetry. The high spatial resolution ensures adequate measurements of dose profiles in regular and intensity modulated photon-beam fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tungsten quasispherical wire loads with a profiled mass

Wire arrays made from micrometer tungsten wires with linear mass profiled along their height are developed for experiments on the generation of X-ray radiation upon pinch compression with a current of ∼3 MA at a pulse duration of ∼100 ns. Wires are imaged with a scanning electron microscope, and their diameter is determined. It is shown that the arrays have such a profile of height distribution of linear mass that allows for compact spherical compression upon current implosion.

36 MATERIALS SCIENCE↗

Real-time scintillation array dosimetry for radiotherapy: The advantages of photomultiplier detectors

Purpose: In this paper, a photomultiplier tube (PMT) array dosimetry system has been developed and tested for the real-time readout of multiple scintillation signals from fiber optic dosimeters. It provides array dosimetry with the advantages in sensitivity provided by a PMT, but without the need for a separate PMT for each detector element. Methods: The PMT array system consisted of a multianode PMT, a multichannel data acquisition system, housing and optic fiber connections suitable for clinical use. The reproducibility, channel uniformity, channel crosstalk, acquisition speed, and sensitivity of the PMT array were quantified using a constant light source. Its performance was compared to other readout systems used in scintillation dosimetry. An in vivo HDR brachytherapy treatment was used as an example of a clinical application of the dosimetry system to the measurement of dose at multiple sites in the rectum. The PMT array system was also tested in the pulsed beam of a linear accelerator to test its response speed and its application with two separate methods of Cerenkov background removal. Results: The PMT array dosimetry system was highly reproducible with a measurement uncertainty of 0.13% for a 10 s acquisition period. Optical crosstalk between neighboring channels was accounted for by omitting every second channel. A mathematical procedure was used to account for the crosstalk in next-neighbor channels. The speed and sensitivity of the PMT array system were found be superior to CCD cameras, allowing for measurement of more rapid changes in dose rate. This was further demonstrated by measuring the dose delivered by individual photon pulses of a linear accelerator beam. Conclusions: The PMT array system has advantages over CCD camera-based systems for the readout of scintillation light. It provided a more sensitive, more accurate, and faster response to meet the demands of future developments in treatment delivery.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

One dimensional spatial resolution optimization on a hybrid low field MRI-gamma detector

Hybrid systems like Positron Emission Tomography/Magnetic Resonance Imaging (PET/MRI) and MRI/gamma camera, offer advantages combining the resolution and contrast capability of MRI with the better contrast and functional information of nuclear medicine techniques. However, the radiation detectors are expensive and need an electronic set-up, which can interfere with the MRI acquisition process or viceversa. In order to improve these drawbacks, in this work it is presented the design of a low field NMR system made up of permanent magnets compatible with a gamma radiation detector based on gel dosimetry. The design is performed using the software FEMM for estimation of the magnetic field, and GEANT4 for the physical process involved in radiation detection and effect of magnetic field. The homogeneity in magnetic field is achieved with an array of NbFeB magnets in a linear configuration with a separation between the magnets, minimizing the effect of Compton back scattering compared with a no-spacing linear configuration. The final magnetic field in the homogeneous zone is ca. 100 mT. In this hybrid proposal, although the gel detector do not have spatial resolution per se, it is possible to obtain a dose profile (1D image) as a function of the position by using a collimator array. As a result, the gamma detector system described allows a complete integrated radiation detector within the low field NMR (lfNMR) system. Finally we present the better configuration for the hybrid system considering the collimator parameters such as height, thickness and distance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of BCF-10, BCF-12, and BCF-20 Scintillating Fibers for Use in a 1-Dimensional Linear Sensor

One-dimensional fiber-bundle arrays may prove useful in a number of radiation sensing applications where radiation detection over large areas is needed. Tests have been performed to evaluate the light generation and transmission characteristics of 15-meter long, 10-fiber bundles of BCF-10, BCF-12, and BCF-20 scintillating fibers (Saint Gobain) exposed to collimated gamma-ray sources. The test set-up used one R9800 (Hamamatsu) photomultiplier tube (PMT) at each end, with a high-speed waveform digitizer to collect data. Time constraints were imposed on the waveform data to perform time-of-flight analysis of the events in the fiber bundles, eliminating spurious noise pulses in the high gain PMTs and also allowing 1-dimensional localization of interactions along the lengths of the fiber bundles. This paper will present the results of these measurements including the attenuation coefficients of the two fiber types and the timing resolution (position uncertainty) possible for each fiber bundle when using the R9800 PMTs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THE ABUNDANCE OF C{sub 3}H{sub 2} AND OTHER SMALL HYDROCARBONS IN THE DIFFUSE INTERSTELLAR MEDIUM

Hydrocarbons are ubiquitous in the interstellar medium, observed in diverse environments ranging from diffuse to molecular dark clouds and strong photon-dominated regions near H II regions. Recently, two broad diffuse interstellar bands (DIBs) at 4881 A and 5450 A were attributed to the linear version of propynylidene l-C{sub 3}H{sub 2}, a species whose more stable cyclic conformer c-C{sub 3}H{sub 2} has been widely observed in the diffuse interstellar medium at radio wavelengths. This attribution has already been criticized on the basis of indirect plausibility arguments because the required column densities are quite large, N(l-C{sub 3}H{sub 2})/E{sub B-V} =4 Multiplication-Sign 10{sup 14} cm{sup -2} mag{sup -1}. Here we present new measurements of N(l-C{sub 3}H{sub 2}) based on simultaneous 18-21 GHz Very Large Array absorption profiles of cyclic and linear C{sub 3}H{sub 2} taken along sight lines toward extragalactic radio-continuum background sources with foreground Galactic reddening E{sub B-V} = 0.1-1.6 mag. We find that N(l-C{sub 3}H{sub 2})/N(c-C{sub 3}H{sub 2}) Almost-Equal-To 1/15-1/40 and N(l-C{sub 3}H{sub 2})/E{sub B-V} Almost-Equal-To (2 {+-} 1) Multiplication-Sign 10{sup 11} cm{sup -2} mag{sup -1}, so that the column densities of l-C{sub 3}H{sub 2} needed to explain the DIBs are some three orders of magnitude higher than what is observed. We also find N(C{sub 4}H)/E{sub B-V} <1.3 Multiplication-Sign 10{sup 13} cm{sup -2} mag{sup -1} and N(C{sub 4}H{sup -})/E{sub B-V} <1 Multiplication-Sign 10{sup 11} cm{sup -2} mag{sup -1} (3{sigma}). Using available data for CH and C{sub 2}H we compare the abundances of small hydrocarbons in diffuse and dark clouds as a guide to their ability to contribute as DIB carriers over a wide range of conditions in the interstellar medium.

74 ATOMIC AND MOLECULAR PHYSICS↗

Characterization and use of a 2D-array of ion chambers for brachytherapy dosimetric quality assurance

The two-dimensional (2D) ionization chamber array MatriXX Evolution is one of the 2D ionization chamber arrays developed by IBA Dosimetry (IBA Dosimetry, Germany) for megavoltage real-time absolute 2D dosimetry and verification of intensity-modulated radiation therapy (IMRT). The purpose of this study was to (1) evaluate the performance of ion chamber array for submegavoltage range brachytherapy beam dose verification and quality assurance (QA) and (2) use the end-to-end dosimetric evaluation that mimics a patient treatment procedure and confirm the primary source strength calibration agrees in both the treatment planning system (TPS) and treatment delivery console computers. The dose linearity and energy dependence of the 2D ion chamber array was studied using kilovoltage X-ray beams (100, 180 and 300 kVp). The detector calibration factor was determined using 300 kVp X-ray beams so that we can use the same calibration factor for dosimetric verification of high-dose-rate (HDR) brachytherapy. The phantom used for this measurement consists of multiple catheters, the IBA MatriXX detector, and water-equivalent slab of RW3 to provide full scattering conditions. The treatment planning system (TPS) (Oncentra brachy version 3.3, Nucletron BV, Veenendaal, the Netherlands) dose distribution was calculated on the computed tomography (CT) scan of this phantom. The measured and TPS calculated distributions were compared in IBA Dosimetry OmniPro-I'mRT software. The quality of agreement was quantified by the gamma ({gamma}) index (with 3% delta dose and distance criterion of 2 mm) for 9 sets of plans. Using a dedicated phantom capable of receiving 5 brachytherapy intralumenal catheters a QA procedure was developed for end-to-end dosimetric evaluation for routine QA checks. The 2D ion chamber array dose dependence was found to be linear for 100-300 kVp and the detector response (k{sub user}) showed strong energy dependence for 100-300 kVp energy range. For the Ir-192 brachytherapy HDR source, dosimetric evaluation k{sub user} factor determined by photon beam of energy of 300 kVp was used. The maximum mean difference between ion chamber array measured and TPS calculated was 3.7%. Comparisons of dose distribution for different test plans have shown agreement with >94.5% for {gamma} {<=}1. Dosimetric QA can be performed with the 2D ion chamber array to confirm primary source strength calibration is properly updated in both the TPS and treatment delivery console computers. The MatriXX Evolution ionization chamber array has been found to be reliable for measurement of both absolute dose and relative dose distributions for the Ir-192 brachytherapy HDR source.

61 RADIATION PROTECTION AND DOSIMETRY↗

Airfoil Computational Fluid Dynamics - 9k shapes, 2 AoA's

This dataset contains aerodynamic quantities - including flow field values (momentum, energy, and vorticity) and summary values (coefficients of lift, drag, and momentum) - for 8,996 airfoil shapes, computed using the HAM2D CFD (computational fluid dynamics) model. The airfoil shapes were designed using the separable shape tensor parameterization that encodes two-dimensional shapes as elements of the Grassmann manifold. This data-driven approach learns two independent spaces of parameter from a collection of sample airfoils. The first captures large-scale, linear perturbations, and the second defines small-scale, higher-order perturbations. For this data, we used the G2Aero database of over 19,000 airfoil shapes to learn a parameter space that captured a wide array of shape characteristics. We fixed the linear deformations to be the mean over the database and sampled new shapes over a four-dimensional parameter space of higher-order perturbation. This sampling approaches allows for isolated analysis of non-linear airfoil shape deformations while holding other aspects (e.g., airfoil thickness) approximately constant. The aerodynamic quantities for the generated airfoil were obtained using the HAM2D code, which is a finite-volume Reynolds-averaged Navier-Stokes (RANS) flow solver. We employ a fifth-order WENO scheme for spatial reconstruction with Roe's flux difference scheme for inviscid flux and second-order central differencing for viscous flux. A preconditioned GMRES method is applied for implicit integration. The Spalart-Allmaras 1-eq turbulence model is used for the turbulence closure, and the Medida-Baeder 2-eq transition model is applied to account for the effects of laminar turbulent transition. The airfoil grid is generated with a total of 400 points on the airfoil surface, the initial wall-normal spacing of y+ = 1, and an outer boundary located at 300 chord lengths away from the wall. The CFD simulations are performed at a freestream Mach number of 0.1, Reynolds number of 9M, and at two angles of attack, 4 deg. and 12 deg. The simulations were performed using the Bridges-2 system at the Pittsburgh Supercomputing Center in February 2023 as part of the INTEGRATE project funded by the Advanced Research Projects Agency - Energy in the U.S. Department of Energy. The data was collected, reformatted, and preprocessed for this OEDI submission in July 2023 under the Foundational AI for Wind Energy project funded by the U.S. Department of Energy Wind Energy Technologies Office. This dataset is intended to serve as a benchmark against which new artificial intelligence (AI) or machine learning (ML) tools may be tested. Baseline AI/ML methods for analyzing this dataset have been implemented, and a link to their repository containing those models has been provided. The .h5 data file structure can be found in the GitHub Repository resource under explore_airfoil_9k_data.ipynb.

9k↗

Research of sensing characteristic and dynamic measurement of graphene oxides modified flexible arrayed RuO2 chlorine ion sensor

Highlights: • Sensitivity of the flexible arrayed RuO2/GO chlorine ion sensor was improved with optimal GO concentration, which could increase the reaction area between the chlorine ion and chlorine sensing membrane. • The electrochemical impedance spectroscopy (EIS) and atomic force microscope (AFM) were utilized to explain the relationships among the electron transfer resistance, GO modified amount and sensitivity. • The 30 μL/min flow rate of dynamic measurement for flexible arrayed RuO2/0.010 wt% GO chlorine ion sensor was obtained the best sensitivity and linearity 66.673 mV/pCl and 0.998, respectively. - Abstract: In this study, we used the graphene oxide (GO) solution, in which the concentration was from 0.005 wt% to 0.500 wt%, to modify the flexible arrayed ruthenium dioxide (RuO{sub 2}) chlorine ion sensor. It is found that the flexible arrayed RuO{sub 2}/0.010 wt% GO chlorine ion sensor had the best sensitivity (44.445 mV/pCl) and the linearity was 0.971. The electrochemical impedance spectroscopy (EIS) and atomic force microscope (AFM) were utilized to explain the relationships among the electron transfer resistance, GO modified amount and sensitivity. After that, we used the flexible arrayed RuO{sub 2}/0.010 wt% GO chlorine ion sensor and the microfluidic measurement system to investigate the dynamic sensing characteristics with different flow rates from 5 μL/min to 40 μL/min. According to the experimental results, the best sensitivity and linearity of flexible arrayed RuO{sub 2}/0.010 wt% GO chlorine ion sensor were 66.673 mV/pCl and 0.992 at 30 μL/min.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Geometrically Tunable Beamed Light Emission from a Quantum‐Dot Ensemble Near a Gradient Metasurface

Abstract Optical metasurfaces have been widely investigated in recent years as a means to tailor the wavefronts of externally incident light for passive device applications. At the same time, their use in active optoelectronic devices such as light emitters is far less established. This work explores their ability to control the radiation properties of a nearby continuous ensemble of randomly oriented incoherent dipole sources via near‐field interactions. Specifically, a film of colloidal quantum dots is deposited on a plasmonic metasurface consisting of a 1D array of metallic nanoantennas on a metal film. The array is designed to introduce a linear phase profile upon reflection, and a bi‐periodic nanoparticle arrangement is introduced to ensure adequate sampling of the desired phase gradient. Highly directional radiation patterns are correspondingly obtained from the quantum dots at an enhanced emission rate. The underlying radiation mechanism involves the near‐field excitation of surface plasmon polaritons at the metal film, and their selective diffractive scattering by the metasurface into well‐collimated beams along predetermined geometrically tunable directions. These results underscore the distinctive ability of metasurfaces to control radiation properties directly at the source level, which is technologically significant for the continued miniaturization and large‐scale integration of optoelectronic devices.

Wang, Xiaowei↗

High power laser coupling to carbon nano-tubes and ion Coulomb explosion

Linear and non linear interaction of laser with an array of carbon nanotubes is investigated. The ac conductivity of nanotubes, due to uneven response of free electrons in them to axial and transverse fields, is a tensor. The propagation constant for p-polarization shows resonance at a specific frequency that varies with the direction of laser propagation. It also shows surface plasmon resonance at ω=ω{sub p}/√(2), where ω{sub p} is the plasma frequency of free electrons inside a nanotube, assumed to be uniform plasma cylinder. The attenuation constant is also resonantly enhanced around these frequencies. At large laser amplitude, the nanotubes behave as thin plasma rods. As the electrons get heated, the nanotubes undergo hydrodynamic expansion. At an instant when plasma frequency reaches ω{sub p}=√(2)ω, the electron temperature rises rapidly and then saturates. For a Gaussian laser beam, the heating rate is maximum on the laser axis and falls off with the distance r from the axis. When the excursion of the electrons Δ is comparable or larger than the radius of the nanotube r{sub c}, the nanotubes undergo ion Coulomb explosion. The distribution function of ions turns out to be a monotonically decreasing function of energy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of material composition of diamond field emission array cathodes on quality of transversely shaped beams

Diamond field emitter array field emission cathodes (DFEA FECs) are attractive for the next generation of injectors due to their ability to produce transversely shaped beams without the need for complex masking or laser schemes. However, reliability of this cathode technology remains a challenging issue as principal mechanisms guiding and allowing for output beam shaping remained poorly understood. Here, this paper reports the results of testing two DFEA FECs with the same pattern and emitter tip geometry. Although both cathodes were able to sustain gradients of 44 MV/m and produce maximum output integral charge of 0.5 nC per radio frequency pulse, their emission patterns were different. One cathode did not produce a shaped beam, while the other one did. This difference was explained by the extent of the local variations of the diamond material across the arrays as discovered by spatially resolved Raman spectroscopy. The main practical takeaways were (i) tip sharpness was not a prerequisite for producing a shaped beam and instead (ii) material characteristics resulting in different cathode ballast resistance affected emission spatial uniformity across the array and hence the beam shaping.

36 MATERIALS SCIENCE↗

Demonstration of a two-dimensional divertor Thomson scattering system on DIII-D

Recent upgrades providing two-dimensional divertor Thomson scattering (DTS-2D) measurements of T e and n e during a DIII-D plasma shot and a thorough description of system components and their functionality are presented. This system expands the capabilities of the existing single divertor Floor measurement location by introducing seven additional laser beam path options in the poloidal plane, spanning major radii from 1.062 to 1.335 m. The system redirects ~1 J, 50 Hz Nd:YAG laser pulses to the new beam paths within 20 ms, stepping through each path on the divertor Floor every 200 ms during a plasma shot. The laser is redirected using an ex-vessel, fast-steering mirror to one of eight in-vessel beam paths oriented underneath the vessel tiles. Up to eleven measurement positions per beam path, from –1.35 to –1.13 m below the machine midplane, are available by dynamically refocusing the ex-vessel collection fiber array using a high-speed linear stage. As a result, current measurement positions above the divertor Shelf are retained via a hole in the fixed, in-vessel mirror, allowing laser pass through.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

PyTorch Circuit-Aware Bit-Cell Modeling

SAND2024-08549O PyTorch Circuit-Aware Bit-Cell Modeling, a Python library, demonstrates circuit-aware training for analog machine learning accelerators. Built upon PyTorch, this software provides hardware-aware versions of common neural network layers to mitigate non-ideal behavior from novel hardware. The software provides accurate forward and backward pass estimates for hardware-mapped neural networks that are implemented in crossbars (arrays) that contain a non-linear transistor selector device. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Bennett, Christopher↗