Search NASA⌕ Search

SEARCH · Search NASA

Results for “load changes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Thermal conductivity of evacuated perlite at low temperatures as a function of load and load history

Perlite, a powdered insulation, is commonly used in large cryogenic storage dewars. When these dewars are thermally cycled, the perlite in the evacuated space between the inner and outer vessels of the dewar experiences a changing mechanical load due to thermal expansion and contraction of the inner vessel. Thermal conductivity data were obtained using a boil-off calorimeter. The apparent thermal conductivity of evacuated perlite increases strongly with applied load. Hysteretic behavior of the conductivity was observed when perlite was subjected to cyclic mechanical loading.

Dube, W. P.↗

Adsorption mechanism of alkyl hydroxamic acid onto bastnäsite: Fundamental steps toward rational collector design for rare earth elements

Rare earth element (REE) production is limited in part by inefficient strategies for beneficiation. Hydroxamic acid ligands are promising reagents for the selective flotation of bastnäsite [(Ce,La)FCO 3 ], a major REE ore mineral, but the mechanism and energetics of adsorption are not understood, interfering with the design of new, more efficient reagents. In this work, the adsorption of octyl hydroxamic acid onto bastnäsite was calculated using a combination of experimental and computational methods. In-situ attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy revealed changes in the hydroxamate functional group vibrational frequencies, corresponding to chelation with cerium cations at the bastnäsite surface. The results indicate a monodentate chemisorption mechanism at low surface loading that changes to bidentate chemisorption at higher concentrations. This interpretation is supported by molecular vibrational frequency shifts calculated using density functional theory (DFT), and orientation of the hydrocarbon chain measured by sum frequency generation (SFG) vibrational spectroscopy. The binding enthalpies of octyl hydroxamic acid interacting with La and Ce-bastnäsite surfaces were measured using isothermal titration calorimetry (ITC) revealing a stronger coordinating ability with bastnäsite than with a common gangue mineral, calcite (CaCO 3 ). Because octyl hydroxamate favors monodentate adsorption at low surface coverages, the relative chelating strength of metal ions could be a poor predictor for selectivity under monolayer adsorption conditions. At higher surface loadings, where the bidentate mode of adsorption is active, selectivity is likely to be limited by increased flotation of gangue ores.

58 GEOSCIENCES↗

Thermal Cycle and Capacitance Testing of Mezzo Industries Phase Changer Material Heat Capacitor

Effective Thermal management is essential for the safety and performance of human spacecraft, especially during long-duration missions with fluctuating heat loads. Phase Change Material (PCM) heat exchangers offer a compact, efficient solution by storing and releasing thermal energy through latent heat during phase transitions. This allows PCM systems to buffer transient thermal loads without immediate heat rejection, reducing the need for oversized radiators – particularly critical during ascent and re-entry when radiators are stowed. By maintaining stable temperatures in crew cabins and equipment bays, PCM technology enhances crew comfort, protects sensitive systems, and supports long-term mission sustainability with minimal mass and volume impact. A phase change material heat capacitor prototype, designed and built under a NASA Small Business Innovation Research grant by Mezzo Technologies, utilizes a laser welding microtube manufacturing process that promises increased reliability and performance over current manufacturing methods like brazing. This heat exchanger was tested through coolant thermal cycling within the expected flow rates and temperature range of the Orion spacecraft, the crewed spacecraft taking NASA astronauts to the moon under the Artemis Program. The useful heat storage capacitance was measured and compared to Orion spacecraft requirements.

Active Thermal Control Systems↗

Role of insulin-like growth factor-I in the regulation of skeletal muscle adaptation to increased loading

Adaptations in muscle mass stimulated by changes in muscle loading state entail alternations in the synthesis and degradation of myofiber proteins and the modulation of myonuclear number such that the ratio between the number of myonuclei and the size of the myofibers remains relatively constant. As depicted schematically in Figure 2.6, the literature regarding the role of IGF-in mediating muscle adaptation to alterations in loading state suggests the following conclusions: During periods of increased loading, myofibers upregulate the expression and secretion of IGF-I. Acting as an autocrine and/or paracrine growth factor, IGF-I stimulates myofiber anabolic processes. Acting as a paracrine growth factor, IGF-I also stimulates adjacent satellite cells to enter the cell cycle and proliferate. Continued myofiber production of IGF-I stimulates some satellite cells to differentiate and then fuse with myofibers, thus providing additional myonuclei in order to maintain or reestablish the myonucleus to myofiber size ratios of the enlarged myofibers.

Review, Academic↗

A Large-Scale Hardware Experiment Demonstration of Operating High Inverter-Based Resource Power Systems With Grid-Forming Inverters

This paper presents experimental hardware results from a microgrid system as the penetration level of grid-forming (GFM) inverters increases. The experiment aims to showcase the advantages of GFM inverters in enhancing system stability and to investigate the operational challenges in systems relying entirely on inverter-based resources (IBRs). Five test scenarios are devised to progressively increase GFM inverter penetration levels: 0% (S1), 19% (S2), 37% (S3), 68% (S4), and 100% (S5). To ensure consistency, identical loading conditions and dynamic events are applied across all scenarios. The conducted tests include load step changes, output variation of grid-following (GFL) inverters during islanded mode, transition operations (such as synchronization to the grid and islanding), and rateof- change-of-frequency (ROCOF) and voltage jump tests during grid-connected mode. Key findings from the tests are summarized as follows: (1) Scenario S1 proved most challenging for load steps, and GFL variations because of insufficient GFM capacity, leaving the diesel generator unable to handle transient ridethrough; (2) Scenario S5 was the most difficult for transition operations, because the lack of a diesel generator to maintain stiff bus voltage resulted in unexpected reactive power flows during synchronization, causing the point of common coupling (PCC) breaker to trip; (3) Scenarios S4 and S5 were particularly challenging for ROCOF tests because of minimal system inertia, leading to large transients that triggered breaker trips; and (4) Scenario S4 exhibited the strongest voltage recovery capability because of the presence of the diesel generator and a higher number of GFM inverters, both of which possess the highest capacity for reactive power injection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demand Side Management in the Smart Grid: Information Processing for the Power Switch

In this article we discuss the most recent developments in the area of load management, and consider possible interaction schemes of novel architectures with distributed energy resources (DER). In order to handle the challenges faced by tomorrow’s smart grid, which are caused by volatile load and generation profiles (from the large number of plug-in EVs and from renewable integration), the conventional grid operating principle of load-following needs to be changed into load-shaping or generation-following. Demand Side Management will be a most promising and powerful solution to the above challenges. However, many other issues such as load forecasting, pricing structure, market policy, renewable integration interface, and even the AC/DC implementation at the distribution side, need to be taken into the design in order to search for the most effective and applicable solution.

Demand Response↗

The effects of inherent flaws on the time and rate dependent failure of adhesively bonded joints

Inherent flaws, as well as the effects of rate and time, are shown by tests on viscoelastic adhesive-bonded single lap joints to be as critical in joint failure as environmental and stress concentration effects, with random inherent flaws and loading rate changes resulting in an up to 40% reduction in joint strength. It is also found that the asymptotic creep stress, below which no delayed failure may occur, may under creep loading be as much as 45% less than maximum adhesive strength. Attention is given to test results for the case of titanium-LARC-3 adhesive single-lap specimens.

Sancaktar, E.↗

Effect of Body Nose Shape on the Propulsive Efficiency of a Propeller

Report presents the results of an investigation of the propulsive efficiency of three adjustable propellers of 10-foot diameter operated in front of four body nose shapes, varying from streamline nose that continued through the propeller plane in the form of a large spinner to a conventional open-nose radial-engine cowling. One propeller had airfoil sections close to the hub, the second had conventional round blade shanks, and the third differed from the second only in pitch distribution. The blade-angle settings ranged from 20 degrees to 55 degrees at the 0.75 radius. The effect of the body nose shape on propulsive efficiency may be divided into two parts: (1) the change in the body drag due to the propeller slipstream and (2) the change in propeller load distribution due to the change in velocity caused by the body. For the nose shape tested in the report, the first effect is shown to be very small; therefore, the chief emphasis of the report is confined to the second effect.

Stickle, George W↗

Use of Flexible Body Coupled Loads in Assessment of Day of Launch Flight Loads

A Day of Launch flight loads assessment technique that determines running loads calculated from flexible body coupled loads was developed for the Ares I-X Flight Test Vehicle. The technique was developed to quantify DOL flight loads in terms of structural load components rather than the typically used q-alpha metric to provide more insight into the DOL loads. In this technique, running loads in the primary structure are determined from the combination of quasi-static aerodynamic loads and dynamic loads. The aerodynamic loads are calculated as a function of time using trajectory parameters passed from the DOL trajectory simulation and are combined with precalculated dynamic loads using a load combination equation. The potential change in aerodynamic load due to wind variability during the countdown is included in the load combination. In the event of a load limit exceedance, the technique allows the identification of what load component is exceeded, a quantification of how much the load limit is exceeded, and where on the vehicle the exceedance occurs. This technique was used to clear the Ares I-X FTV for launch on October 28, 2009. This paper describes the use of coupled loads in the Ares I-X flight loads assessment and summarizes the Ares I-X load assessment results.

Starr, Brett R.↗

Analysis of a nuclear hybrid energy system using absorption chillers and stratified chilled-water storage with an mPower reactor - 187

The intermittency of renewable energy technology, such as wind and solar power, puts strain on electric grids, often forcing carbon-based and nuclear sources of energy to operate in a load follow mode. Operating nuclear reactors in a load-follow fashion is undesirable due to the associated thermal and mechanical stresses placed on the fuel and reactor components. Various methods of Thermal Energy Storage (TES) can be coupled to nuclear (or renewable) power sources to help absorb grid instabilities caused by daily load demand changes and renewable intermittency. This is known as a Nuclear Hybrid Energy System (NHES). Previous research has found that a stratified chilled-water storage tank can help displace peak cooling loads to off-peak hours. In this study, a dynamic single effect, lithium bromide absorption chiller model was developed as a callable FORTRAN subroutine. Cooling towers, a stratified chilled-water storage tank, and cooling loads characteristic of a large campus were included to form a comprehensive TES model. This TES model was coupled to a high-fidelity mPower sized Small Modular Reactor (SMR) FORTRAN code that provides the transient behavior of primary and secondary-side components. Control algorithms based on excess capacity and conditions in the stratified chilled-water storage tank were used to determine when to divert low-pressure steam from the turbines to the absorption chillers in order to keep reactor power near steady-state. Simulation results depict how the TES system and SMR interact, and demonstrate that stratified chilled-water storage is a viable TES technology for an SMR in a NHES. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Influence of Alternating Short-Cycle Bending on the Mechanical Properties of Copper, α-Titanium and the Mild Steel DC01

The influence of alternating bending loads as they occur during roller levelling on the mechanical properties of sheet metals is not yet fully understood. A detailed knowledge of the influence of the commonly used levelling process on the resulting properties of sheet material is needed in particular for the design of subsequent processes with narrow process windows. To investigate the mechanical property changes during loading conditions similar to roller levelling, sheet samples of mild steel DC01, α-titanium and pure copper (CU-DHP) were subjected to alternating bending loads with different amplitudes for up to 9.5 bending cycles. An isotropic hardening behavior according to a Voce description could be shown for the DC01 deep drawing steel with a strong dependence on the load amplitude applied per cycle. A strengthening behavior that depends on the loading amplitude could be observed for α-titanium as well. In contrast, pure copper featured minor changes with a tendency to soften. For all three materials, changes in springback were present after one bending cycle.

36 MATERIALS SCIENCE↗

Chemical Feedback in the Self-Assembly and Function of Air–Liquid Interfaces: Insight into the Bottlenecks of CO 2 Direct Air Capture

As fossil fuels remain a major source of energy throughout the world, developing efficient negative emission technologies, such as direct air capture (DAC), which remove carbon dioxide (CO 2 ) from the air, becomes critical for mitigating climate change. Although all DAC processes involve CO 2 transport from air into a sorbent/solvent, through an air–solid or air–liquid interface, the fundamental roles the interfaces play in DAC remain poorly understood. In this work, we study the interfacial behavior of amino acid (AA) solvents used in DAC through a combination of vibrational sum frequency generation spectroscopy and molecular dynamics simulations. This study revealed that the absorption of atmospheric CO 2 has antagonistic effects on subsequent capture events that are driven by changes in bulk pH and specific ion effects that feedback on surface organization and interactions. Among the three AAs (leucine, valine, and phenylalanine) studied, we identify and separate behaviors from CO 2 loading, chemical changes, variations in pH, and specific ion effects that tune structural and chemical degrees of freedom at the air–aqueous interface. The fundamental mechanistic findings described here are anticipated to enable new approaches to DAC based on exploiting interfaces as a tool to address climate change.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

LANDSAT-1 data as it has been applied for land use and water quality data by the Virginia State Water Control Board. 1: The state project. 2: Monitoring water quality from LANDSAT

LANDSAT-1 imagery has been used for water quality and land use monitoring in and around the Swift Creek and Lake Chesdin Reservoirs in Virginia. This has proved useful by (1) helping determine valid reservoir sampling stations, (2) monitoring areas not accessible by land or water, (3) giving the State a viable means of measuring Secchi depth readings in these inaccessible areas, (4) giving an overview of trends in changing sedimentation loadings over a given time period and classifying these waters into various categories, (5) enabling the State to inventory all major lakes and reservoirs and computing their acreage, (6) monitoring land use changes in any specific area, (7) evaluating possible long-term environmental effects of nearby developments, and (8) monitoring and predicting population shifts with possible impact on water quality problems. The main problems in the long-term use of such imagery appear to be cost and lack of consistency due to cloud cover limitations.

Trexler, P. L.↗

Using the Enhanced Daily Load Stimulus Model to Quantify the Mechanical Load and Bone Mineral Density Changes Experienced by Crew Members on the International Space Station

Despite the use of exercise countermeasures during long-duration space missions, bone mineral density (BMD) and predicted bone strength of astronauts continue to show decreases in the lower extremities and spine. This site-specific bone adaptation is most likely caused by the effects of microgravity on the mechanical loading environment of the crew member. There is, therefore, a need to quantify the mechanical loading experienced on Earth and on-orbit to define the effect of a given "dose" of loading on bone homeostasis. Gene et al. recently proposed an enhanced DLS (EDLS) model that, when used with entire days of in-shoe forces, takes into account recently developed theories on the importance of factors such as saturation, recovery, and standing and their effects on the osteogenic response of bone to daily physical activity. This algorithm can also quantify the tinting and type of activity (sit/unload, stand, walk, run or other loaded activity) performed throughout the day. The purpose of the current study was to use in-shoe force measurements from entire typical work days on Earth and on-orbit in order to quantify the type and amount of loading experienced by crew members. The specific aim was to use these measurements as inputs into the EDLS model to determine activity timing/type and the mechanical "dose" imparted on the musculoskeletal system of crew members and relate this dose to changes in bone homeostasis.

Genc, K. O.↗

A Review of Transformer Aging and Control Strategies

Transformer aging is an important challenge in power system. Distribution transformers themselves are minimally controllable, but smart meters provide excellent, new insights into electrical loads, which insights can be used to understand and mitigate transformer aging. The nature of transformer loads is changing with the integration of distributed energy resources (DERs) and electric vehicles (EVs). This paper first reviews factors that influence the aging of distribution transformers, including root causes of transformer failure. Existing and proposed load control methods are then discussed. A distribution model is introduced to help evaluate potential control methods.

Gourisetti, Sri Nikhil Gup↗

Effects of loading rate and temperature on dynamic fracture of ceramic matrix composites

A hybrid experimental-numerical procedure was used to determine the dynamic fracture initiation toughnesses and the dynamic stress intensity factors of alumina, TiB2-particulate/SiC-matrix, and SiC(w)/Al2O3-matrix composites at room and elevated temperatures under static and impact loadings. The dynamic fracture initiation toughnesses at room and elevated temperatures were greater than the corresponding static fracture toughness. The crack velocity versus the dynamic stress intensity factor relations showed minor differences due to temperature changes but significant differences due to the change in loading rates.

Yang, K. H.↗

Damage Tolerance Testing of a NASA TransHab Derivative Woven Inflatable Module

Current options for Lunar habitat architecture include inflatable habitats and airlocks. Inflatable structures can have mass and volume advantages over conventional structures. Inflatable structures are perceived to carry additional risk because they are at a lower Technical Readiness Level (TRL) than conventional metallic structures. One of the risks associated with inflatable structures is understanding the tolerance to component damage and the resulting behavior of the system after the damage is introduced. The Damage Tolerance Test (DTT) is designed to study the structural integrity of an expandable structure during and subsequent to induced damage. The TransHab Project developed an experimental inflatable module developed at Johnson Space Center in the 1990's. The TransHab design was originally envisioned for use in Mars Transits but was also studied as a potential habitat for the International Space Station (ISS). The design of the TransHab module was based on a woven design using an Aramid fabric. Testing of this design demonstrated a high level of predictability and repeatability and good correlation with analytical predictions of stresses and deflections. Based on JSC's experience with the design and analysis of woven inflatable structures, the Damage Tolerance Test article was designed and fabricated using a woven design. The Damage Tolerance Test Article consists of a load bearing restraint layer, a bladder or gas barrier, and a structural metallic core. The test article restraint layer is fabricated from one inch wide Kevlar webbing that is woven in a basket weave pattern. Underneath the structural restraint layer is the bladder or gas barrier. For this test the bladder was required to maintain pressure for testing only and was not representative of a flight design. The bladder and structural restraint layer attach to the structural core of the module at steel bulkheads at each end. The two bulkheads are separated by a 10 foot center tube which provides the structural support for the module when in a non-inflated state as well as resists a portion of the axial load when pressurized. The longitudinal members of the structural restraint layer are attached to the bulkheads using a series of clevises that are bolted to the bulkheads. Strain gages are placed on the clevises that can measure change in load when the structural restraint is inflated. The test module is 88 inches in diameter and 120 inches in height. The objectives of the DTT are to (1) verify the structural integrity of the assembled and pressurized structure when a section of the structural restraint layer is cut by a foreign object, and (2) verify the load distribution of the structural restraint layer during pressurization, before and after the structural restraint layer is severed. For this test, a longitudinal structural restraint strap will be severed using a linear shape charge. The linear shape charge was designed specifically for this application to cut only a single longitudinal strap, while not damaging the bladder. An array of strain gages were located at the bulkhead mounted clevises where the longitudinal restraint layer straps are attached. The DTT article was inflated to 45 psig, 25% of the ultimate design pressure, and one of the one-inch wide longitudinal structural members was severed. Strain gage measurements of loading in an array of longitudinal straps were taken throughout pressurization of the module to 45 psig, before firing of the linear shape charge, and after firing of the shape charge and separation of the strap. During testing not only were the original objectives met but better than expected results occurred. This paper will discuss space inflatable structures, damage tolerance analysis, test results, and applicability to the Lunar architecture.

Edgecombe, John↗

Load insensitive electrical device

A class of power converters is described for supplying direct current at one voltage from a source at another voltage. It includes a simple passive circuit arrangement of solid-state switches, inductors, and capacitors by which the output voltage of the converter tends to remain constant in spite of changes in load. The switches are sensitive to the current flowing in the circuit and are employed to permit the charging of capacitance devices in accordance with the load requirements. Because solid-state switches (such as SCR's) may be used with relatively high voltage and because of the inherent efficiency of the invention that permits relatively high switching frequencies, power supplies built in accordance with the invention, together with their associated cabling, can be substantially lighter in weight for a given output power level and efficiency of operation than systems of the prior art.

Schwarz, F. C.↗