Search NASA⌕ Search

SEARCH · Search NASA

Results for “long term testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Accelerated Corrosion Tests to Evaluate Long-Term Performance of BORAL{sup R} in Spent Fuel Pools

Neutron absorber materials are used to increase storage capacity in spent fuel pools (SFPs) while maintaining criticality safety margins. BORAL{sup R} - a neutron absorber material commonly used in SFPs - is a metal matrix composite containing boron carbide (B{sub 4}C) and Al-1100 mixture. The aluminum (Al) cladding, which is on both sides of the core, serves as a protective barrier. Al cladding is susceptible to corrosion, which can lead to blisters between the core material and the cladding over time. Based on operational experience to date, pits also have been observed via visual examination and microscopy. EPRI has maintained a database containing coupon data spanning more than 25 years, and to date no loss of BORAL{sup R} efficacy has been observed. In the United States, about 50% of the plants use BORAL{sup R} as neutron absorber material in SFPs. BORAL{sup R} is also used in nuclear plants in Mexico, Korea, Taiwan, and other countries. Given that the plant lifetime is increasing-and, hence, the SFP lifetime-EPRI initiated a five-year accelerated corrosion test in 2013 to evaluate and determine the long-term performance of BORAL{sup R} in SFPs. This paper presents an overview of the accelerated corrosion test project. Results from the Year 1 and Year 2 test results are also presented. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Long-Term Evaluation of Remedial Technology Performance in the Laboratory: Multi-year Experimental Test Plan

An understanding of the long-term effectiveness of remediation technologies is central to sustainable environmental cleanup. Long-term experiments are valuable for reducing uncertainty and predicting remediation outcomes at scales required for regulatory compliance. However, these types of tests can be costly and challenging to interpret. Therefore, contaminated sites often rely on short-term laboratory experiments that may not account for the potentially significant effects of gradual, time- dependent processes governing contaminant retention, release, and species transformation. For example, short-term lab experiments (from months to a year) conducted with sediments from the unsaturated and saturated zones at the Hanford Site play an important role in initial evaluations of remediation technologies but cannot capture the full extent of time-dependent reactions, leaving uncertainties in field-scale deployment. Here, long-term testing will be conducted on select technologies based on their performance in short-term testing. The overall objective is to directly address the challenges described above by generating and analyzing data on long-term (2–10 years) efficacy of selected remediation technologies, integrating this understanding into models, and providing critical input for remediation planning, monitoring, and 5-year review cycles for field-implemented remedies. Specific objectives include: 1. Evaluating long-term efficiency of promising remedies under site-specific conditions. 2. Generating robust parameters for modeling, reducing uncertainty in predictive simulations. 3. Advancing integrated monitoring by combining geochemical and geophysical observations. 4. Informing field-scale implementation by incrementally advancing technologies, identifying failure mechanisms early, and prioritizing robust, cost-effective remedies. Through systematic evaluation of technologies in laboratory-scale column experiments, integrated monitoring, and modeling support, this project is designed to bolster confidence in the long-term robustness of selected technologies. The ultimate outcome is the identification and deployment of more reliable, cost-effective remedies that safeguard human health and the environment while reducing the uncertainties that have historically hindered cleanup progress at Hanford Site. An experimental approach was developed and initiated for long-term testing potentially up to 10 years. The table below summarizes the experimental approach developed for testing select technologies and presented in this multi-year experimental test plan.

54 ENVIRONMENTAL SCIENCES↗

LONG-TERM GRADIENT TEMPERATURE STRESS RELAXATION TESTING AND MODELING OF CERAMIC INSULATION MATERIALS

Testing was carried out to characterize and predict the long-term thermomechanical properties of Thermal Ceramics Min-K 1400TE thermal insulation material, hereafter referred to as Min-K. In particular, the high temperature compressive strength and stress relaxation behavior of Min-K up to 900 C was evaluated under various thermal gradients and a helium atmosphere for test times of up to over two years. Additionally, finite element and mathematical models were formulated to predict the mechanical behavior exhibited by Min-K out to 35,000 hours (4 years) based on this testing. This presentation will discuss the design and construction of unique test equipment to carry out this testing, along with the results of the testing and the subsequent modeling.

36 MATERIALS SCIENCE↗

Enhanced Oxidation Catalysts for Water Reclamation

This effort seeks to develop and test high-performance, long operating life, physically stable catalysts for use in spacecraft water reclamation systems. The primary goals are to a) reduce the quantity of expendable water filters used to purify water aboard spacecraft, b) to extend the life of the oxidation catalysts used for eliminating organic contaminants in the water reclamation systems, and c) reduce the weight/volume of the catalytic oxidation systems (e.g. VRA) used. This effort is targeted toward later space station utilization and will consist of developing flight-qualifiable catalysts and long-term ground tests of the catalyst prior to their utilization in flight. Fixed -bed catalytic reactors containing 5% platinum on granular activated carbon have been subjected to long-term dynamic column tests to measure catalyst stability vs throughput. The data generated so far indicate that an order of magnitude improvement can be obtained with the treated catalysts vs the control catalyst, at only a minor loss (approx 10%) in the initial catalytic activity.

Jolly, Clifford D.↗

Lithium battery discharge tests

The long term discharge of a variety of lithium cells was characterized and the susceptibility of the cells to chemical variation during the slow discharge was tested. A shunt resistor was set across the terminals to monitor the voltage as a function of time. Failures were identified by premature voltage drops.

Johnson, C. J.↗

Chemical cleaning of porous stainless steel cross-flow filter elements for nuclear waste applications

The Waste Treatment and Immobilization Plant (WTP) currently under construction for treatment of High-Level Waste (HLW) at the Hanford Site will rely on cross-flow ultrafiltration to provide solids-liquid separation as a core part of the treatment process. To optimize process throughput, periodic chemical cleaning of the porous stainless steel filter elements has been incorporated into the design of the plant. It is currently specified that chemical cleaning with nitric acid will occur after significant irreversible membrane fouling is observed. Irreversible fouling is defined as fouling that cannot be removed by backpulsing the filter. PNNL has investigated chemical cleaning processes as part of integrated tests with HLW simulants and with actual Hanford tank wastes. To quantify the effectiveness of chemical cleaning, the residual membrane resistance after cleaning was compared against the initial membrane resistance for each test in a series of long-term fouling tests. The impact of the small amount of residual resistance in these tests could not be separated from other parameters and the historical benchmark of >1 GPM/ft2 for clean water flux was determined to be an adequate metric for chemical cleaning. Using the results from these tests, a process optimization strategy is presented suggesting that for the simulant material under test, the value of chemical cleaning may be suspect. The period of enhanced filtration may not be enough to offset the down time required for chemical cleaning, without respect to the other associated costs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Examination of Cavity Formation in Cold-Worked Alloy 690

Although stress corrosion cracking (SCC) has not been reported in Alloy 690 components after more than 30 years of pressure water reactor (PWR) service, susceptibility to SCC growth in PWR primary water has been reported by many labs for highly CW Alloy 690 along with isolated observations of crack initiation. Post-test examinations on SCC initiation specimens suggested a key role of creep by inducing the formation and growth of grain boundary cavities at carbide interfaces leading to intergranular cracking. However, it is clear that high levels of cold work can produce grain boundary voids and complicates the quantitative evaluation of damage evolution during testing in high-temperature water. Therefore, it is crucial to understand how to properly examine and classify this type of damage in the pre-test condition and establish its evolution with time. This paper outlines our observational protocols on how to best prepare sample surfaces to avoid inducing artifacts, and to perform subsequent examinations utilizing scanning electron microscopy, transmission electron microscopy and focused ion beam milling to assess the formation and development of grain boundary cavities. Detailed examinations will be reviewed on several commercial Alloy 690 heats in the pre-test CW condition and after long-term initiation testing at constant load in 360°C simulated PWR primary water to effectively document grain boundary cavity formation and growth leading to crack initiation.

Olszta, Matthew J.↗

Validation of Lifetime Models for Recuperator Foils Through Long-Term Laboratory and Engine Testing

For the next-generation of turbine-based combined heat & power (CHP) systems, materials development can enable lower costs and higher efficiency, particularly for alloy foils used in the recuperator. To quantify the potential benefits, lifetime models are being developed for current chromia-forming alloys such as 625, 120, 310 and 709 (also called 2025Nb) as well as new alumina-forming austenitic (AFA) steels, which are much more oxidation resistant in exhaust gas. A combination of long-term laboratory (up to 30 kh) and field exposure data (up to 100 kh) are being used to develop and validate the model for operation at 650°–800°C.

Dryepondt, Sebastien↗

Reliability Testing Beyond Qualification as a Key Component in Photovoltaic's Progress Toward Grid Parity: Preprint

This paper discusses why it is necessary for new lower cost PV modules to be tested using a reliability test sequence that goes beyond the Qualification test sequence now utilized for modules. Today most PV modules are warranted for 25 years, but the Qualification Test Sequence does not test for 25-year life. There is no accepted test protocol to validate a 25-year lifetime. This paper recommendsthe use of long term accelerated testing to compare now designs directly with older designs that have achieved long lifetimes in outdoor exposure. If the new designs do as well or better than the older ones, then it is likely that they will survive an equivalent length of time in the field.

14 SOLAR ENERGY↗

Compaction of crushed salt for safe containment – a summary of the KOMPASS projects

Abstract. For the underground disposal of high-level nuclear waste in rock salt formations, the safety concept includes the backfilling of open cavities with crushed salt. For the prognosis of the sealing function of the backfill for the safe containment of the radioactive waste, it is crucial to have a comprehensive process understanding of the crushed-salt compaction behavior. The crushed-salt compaction process is influenced by internal properties (e.g., grain size, mineralogy, and moisture content) and boundary conditions (e.g., temperature, stress state, and compaction rate) and, therefore, involves several coupled thermal–hydro–mechanical (THM) processes (Hansen et al., 2014; Kröhn et al., 2017). With the paradigm shift from the limited release of radionuclides to safe containment due to the German Repository Site Selection Act passed in 2017, the importance of crushed salt as geotechnical barrier has increased, with a focus on the evolution of its hydraulic properties. Based on the knowledge gaps in the current process understanding, the “Compaction of crushed salt for safe containment” (KOMPASS) projects were initiated to improve the scientific basis behind using crushed salt for the long-term isolation of high-level nuclear waste within rock salt repositories. The efforts to improve the prediction of crushed-salt compaction begun during the first phase of the KOMPASS projects (Czaikowski et al., 2020) and were followed up in a second phase ending in June 2023. The primary achievements of the projects are as follows (Czaikowski et al., 2020; Friedenberg et al., 2022): specification of the KOMPASS reference material, an easily available and reproducible synthetic crushed-salt material, for generic investigations; development of pre-compaction methods and successful production of samples in the short term and under in situ loading conditions; formulation of an extended laboratory program addressing the isolated investigation of known relevant factors influencing the compaction behavior of crushed salt (Düsterloh et al., 2022); execution of long-term compaction tests addressing isotropic and deviatoric load changes, temperature, and compaction state; construction of a backfill body using the KOMPASS reference material in the Sondershausen mine through collaboration with the SAVER (Entwicklung eines salzgrusbasierten Versatzkonzepts unter der Option Rückholbarkeit) project (Schaarschmidt and Friedenberg, 2022); advancement of the tools for microstructure investigation methods (Svensson and Laurich, 2022); generation (first stages) of a microphysical process list combining literature research with our own findings; benchmarking of long-term compaction test for model development and optimization of various existing models as well as the development of new models; application of a virtual demonstrator (2D model representing a backfilled drift in rock salt) for the visualization of developments and the quantification of the models (Rabbel, 2022). In summary, the KOMPASS projects contributed to the reduction of uncertainties and the strengthening of the safety case for using crushed salt within rock salt repositories.

Friedenberg, Larissa↗

The EGS Collab Project: Status and Accomplishments

The EGS Collab project, supported by the US Department of Energy, is addressing challenges in implementing enhanced geothermal systems (EGS). This includes improving understanding of the stimulation of crystalline rock to create appropriate flow pathways, and the ability to effectively simulate both the stimulation and the flow and transport processes in the resulting fracture network. The project is performing intensively monitored rock stimulation and flow tests at the 10-m scale in an underground research laboratory. Data and observations from the field test are compared to simulations to understand processes and to build confidence in numerical modeling of the processes. In Experiment 1, we examined hydraulic fracturing an underground test bed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, at a depth of approximately 1.5 km. We drilled eight sub-horizontal boreholes in a well-characterized phyllite. Six of the boreholes were instrumented with many sensor types to allow careful monitoring of stimulation events and flow tests, and the other two boreholes were used for water injection and production. We performed a number of stimulations and flow tests in the testbed. Our monitoring systems allowed detailed observations and collection of numerous data sets of processes occurring during stimulation and during dynamic flow tests. Long-term ambient temperature and chilled water flow tests were performed in addition to many tracer tests to examine system behavior. Data were rapidly analyzed, allowing adaptive control of the tests. Numerical simulation was used to answer key experimental design questions, to forecast fracture propagation trajectories and extents, and to analyze and evaluate results. Many simulations were performed in near-real-time in conjunction with the field experiments, with more detailed process study simulations performed on a longer timeframe. Experiment 2 will examine hydraulic shearing in a test bed being built at the SURF at a depth of about 1.25 km in amphibolite under a different set of stress and fracture conditions than Experiment 1. Five sets of fracture orientations were considered in design, and three orientations seem to be consistently observed.

EGS Collab↗

Creep Property Characterization of Potential Brayton Cycle Impeller and Duct Materials

Cast superalloys have potential applications in space as impellers within closed-loop Brayton cycle nuclear power generation systems. Likewise wrought superalloys are good candidates for ducts and heat exchangers transporting the inert working gas in a Brayton-based power plant. Two cast superalloys, Mar-M247LC and IN792, and a NASA GRC powder metallurgy superalloy, LSHR, have been screened to compare their respective capabilities for impeller applications. Mar-M247LC has been selected for additional long term evaluations. Initial tests in helium indicate this inert environment may debit long term creep resistance of this alloy. Several wrought superalloys including Hastelloy(Registered TradeMark) X, Inconel(Registered TradeMark) 617, Inconel(Registered TradeMark) 740, Nimonic(Registered TradeMark) 263, Incoloy(Registered TradeMark) MA956, and Haynes 230 are also being screened to compare their capabilities for duct applications. Haynes 230 has been selected for additional long term evaluations. Initial tests in helium are just underway for this alloy. These proposed applications would require sufficient strength and creep resistance for long term service at temperatures up to 1200 K, with service times to 100,000 h or more. Therefore, long term microstructural stability is also being screened.

Gabb, Timothy P.↗

Preliminary Testing of Electrolytic Silver Ion Generation for Spacecraft Potable Water Systems

Anodic dissolution of silver electrodes, or “silver electrolysis,” is being investigated as a means of imparting biocidal silver into potable water on exploration spacecraft. This method of water disinfection is used commercially in hospitals and marine vessels, but the spacecraft application poses unique challenges such as low water conductivity, increased importance of electrode longevity, and an interface with other systems that may be sensitive to any particles released in the electrolysis process. Testing has shown that due to the low conductivity of the water, the electroactive area of the cell can be scaled linearly to achieve a target electrolysis current despite the general non-linearity of electrochemical systems. More importantly, however, the low conductivity dictates that a large electroactive area and minimal electrode gap be employed in the design. Furthermore, thermodynamic considerations suggest that a low applied voltage is necessary to avoid undesired electrode reactions that could negatively impact long-term performance. Preliminary testing of long-term electrode health suggests that anodic oxide formation may not present as significant a challenge as anticipated; however, further testing in a system closed to the atmosphere is required to rule out the influence of atmospheric CO2 on the pH of the process water. Comparison of filtered and unfiltered silver concentration measurements indicates that release of particles larger than 0.2 μm was negligible in this preliminary test. A test article has been developed to facilitate further testing of silver electrolysis, which continues to be a candidate technology for spacecraft potable water disinfection.

silver↗

“Ni-Less” Cathodes for High Energy Density, Intermediate Temperature Na-NiCl 2 Batteries

Among various battery technologies being considered for stationary energy storage applications, sodium-metal halide (Na-MH) batteries have become one of the most attractive candidates because of the abundance of raw materials, long cycle life, high energy density, and superior safety. However, one of issues limiting its practical application is the relatively expensive nickel (Ni) used in the cathode. In the present work, we focus on of efforts to develop new Ni-based cathodes, and demonstrate that a much higher specific energy density of 405 Wh/kg (23% higher than state-of-the-art Na-MH batteries) can be achieved at an operating temperature of 190oC. Furthermore, 15% less Ni is used in the new cathode than that in conventional Na-NiCl2 batteries. Long-term cycling tests also show stable electrochemical performance for over 300 cycles with excellent capacity retention (~100%). The results in this work indicate that these advances can significantly reduce the raw material cost associated with Ni (a 31% reduction) and promote practical applications of Na-MH battery technologies in stationary energy storage systems.

Chang, Hee-Jung↗

Long term behavior of silicon germanium thermoelectric generators

Results of tests of the long term performance of SiGe radioisotope thermoelectric generators (RTG) are presented. Three modules were monitored for 17,000-32,300 hr at hot junction temperatures of 1,085, 1,055, and 1,000 C; coating the unicouples with a 12,000 A thick layer of Si3N4 protected the modules from Si sublimation. Output degraded less than 0.3-0.4%/1,000 hr over the testing period. Life tests on a multihundredwatt (MHW) SiGe generator with 312 couples at a hot shoe temperature of 1,040 C dealt with power of 150 W at 30 V, with 0.5%/1,000 hr performance degradation. Si deposition on the insulation was found to enhance electrical conductance until a saturation point was reached. Disassembly of a test module after 16,750 hr revealed a Mo build-up, SiN4 coating deterioration, and Ti diffustion from the hot shoe to cooler regions of the junction. The presence of an Al2O3 insulator was recognized as preventing coating loss. Performance records from the Voyager and Les-8 satellites' RTG's are compared and show similar, 0.25%/1,000 hr degradation rates; RTG storage is judged to be feasible and the tests lead to projections of a 600,000 hr lifetime for a SiGe RTG.

Shields, V.↗

Long-term high-velocity oxidation and hot corrosion testing of several NiCrAl and FeCrAl base oxide dispersion strengthened alloys

Several oxide dispersion strengthened (ODS) alloys have been tested for cyclic, long-term, high gas-velocity resistance to oxidation at 1100 C and hot corrosion at 900 C. Both nominally Ni-16Cr-4Al and Fe-20Cr-4.5Al ODS alloys were subjected up to about 2500 cycles, where each cycle consisted of 1 hr in a hot, Mach 0.3 combusted gas stream followed by a 3-min quench in an ambient temperature, Mach 0.3 air blast. For comparison to existing technology, a coated superalloy was simultaneously tested. The ODS iron alloy exhibited clearly superior behavior, surviving 3800 oxidation and 2300 hot corrosion cycles essentially unscathed. While the ODS nickel alloys exhibited adequate oxidation resistance, the long-term hot corrosion resistance could be marginal, since the best life for such alloys under these conditions was only about 1100 cycles. However, the hot corrosion resistance of the ODS Ni-base alloys is excellent in comparison to that of traditional superalloys.

Lowell, C. E.↗

Cr Field Testing

This is a summary of CR Project Field Tests including: Borehole Dilution Tracer Tests (Point Estimates of Flow Velocity), Push-Pull Tracer Tests at R-42 and R-28 (Flow Velocity and Dual-Porosity), Long Term Pump Test Trends, Carbonate/Bicarbonate Injection in R-42 (Cr desorption?), Cross-Hole Tracer Test (CrPZ-2a, CrPZ-2b, R-28 Injections; CrEX-3 Pumping), and Long-Term Trends in Plume Periphery Monitoring Wells.

58 GEOSCIENCES↗

Balanced interferometric system for stability measurements

We describe two different, double-sided interferometer designs for measuring material stability. Both designs are balanced interferometers where the only optical path difference is the sample and the reference beams are located within the interferometer. One interferometer is a double-pass design, whereas the other is a single-pass system. Based on a tolerancing analysis, the single-pass system is less susceptible to initial component misalignment and motions during experiments. This single-pass interferometer was tested with an 86 nm thin-film silver sample for both short-term repeatability and long-term stability. In 66 repeatability tests of 30 min each, the mean measured drift rate was less than 1 pm/h rms. In two long-term tests (>9 h), the mean drift rate was less than 1.1 pm/h, which shows good agreement between the short- and long-term measurements. In these experiments, the mean measured length change was 2 nm rms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗