Search NASA⌕ Search

SEARCH · Search NASA

Results for “maintenance energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Vertically Resolved Analysis of the Madden-Julian Oscillation Highlights the Role of Convective Transport of Moist Static Energy

We simulate the Madden-Julian oscillation (MJO) over an aquaplanet with uniform surface temperature using the multiscale modeling framework (MMF) configuration of the Energy Exascale Earth System Model (E3SM-MMF). The model produces MJO-like features that have a similar spatial structure and propagation behavior to the observed MJO. To explore the processes involved in the propagation and maintenance of these MJO-like features, we perform a vertically resolved moist static energy (MSE) analysis for the MJO (Yao et al., 2022, https://doi.org/10.1175/jas-d-20-0254.1). Unlike the column-integrated MSE analysis, our method emphasizes the local production of MSE variance and quantifies how individual physical processes amplify and propagate the MJO's characteristic vertical structure. We find that radiation, convection, and boundary layer (BL) processes all contribute to maintaining the MJO, balanced by the large-scale MSE transport. Furthermore, large-scale dynamics, convection, and BL processes all contribute to the propagation of the MJO, while radiation slows the propagation. Additionally, we perform mechanism-denial experiments to examine the role of radiation and associated feedbacks in simulating the MJO. We find that the MJO can still self-emerge and maintain its characteristic structures without radiative feedbacks. This study highlights the role of convective MSE transport in the MJO dynamics, which was overlooked in the column-integrated MSE analysis.

54 ENVIRONMENTAL SCIENCES↗

Safety Codes and Standards Review and Gap Analysis for Applicability to Hydrogen Rail Refueling, Defueling, Maintenance, and Storage

Hydrogen-powered locomotives may present an alternative to diesel for achieving transportation-related decarbonization, energy security, and resilience goals. As an emerging technology, hydrogen locomotives may not have adequate representation in current safety codes and standards. NFPA 2 and other appropriate codes and standards were reviewed to identify technical gaps in the code for hydrogen rail defueling, refueling, maintenance, and storage. Several technical gaps pertaining to setback distances, allowable quantities, ventilation rates, and grounding have been identified. Fueling requirements can be informed by road vehicle standards but may need to be revised for larger quantity hydrogen locomotive systems. Since there are no hydrogen-specific locomotive design and safety standards, some aspects of diesel-based locomotive standards may apply. CGA G- 5.5 currently provides the most guidance on height, placement, orientation, and design of vent systems, while other standards emphasize the importance of shielding vent stacks and provide requirements for orientation of their discharge.

08 HYDROGEN↗

An Observational Understanding of Connected Lighting Systems

As part of the Internet of Things (IoT), connected lighting systems provide additional control capabilities and nonlighting-related services (such as communications and data infrastructure) to reduce energy use while increasing both application efficiency and system value. But the positive or negative energy impact of implementing these systems is still largely unknown due to the variety of human factors associated with installation, maintenance, and use. These complications interfere with adoption and acceptance rates of products that will play a significant role in achieving energy savings long-term. Next Generation Lighting Systems, or NGLS, developed and implemented an observational research methodology for connected lighting systems. The methodology was implemented at an indoor (classroom/office) Living Lab at Parsons School of Design in New York City, and an outdoor (parking lot) Living Lab at Virginia Tech Transportation Institute in Blacksburg, Virginia. Although this report focuses on the approach to indoor installations, observational research in both settings provides insight to the type, scale, and frequency of issues across available products as experienced by installing contractors, end users, and other stakeholders.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydropower Flexibility Framework (Final Technical Report)

The Hydropower Flexibility Framework (HFF) tool focuses on providing the hydropower community with an effective means of assessing optimized hydropower plant outcomes. This tool combines both site specific characteristics, which act to constrain plant operation, and the hydrologic and grid characteristics which drive hydropower plant operation. The hydropower community faces a confluence of factors which drive the importance of developing such a capability, including an aging hydropower fleet subject to a range of modernization opportunities, a large number of hydropower plant relicensing activities which may affect operational requirements, an electrical grid with increasing levels of variable resources which must be balanced to maintain grid stability, and climate change influencing riverine hydrologic patterns outside of design characteristics. With support from the hydropower community, the project team developed the HFF tool and demonstrated the tool through a series of Use Cases. This guidance was developed as a part of the larger HFF tool User’s Manual (see Appendix B), a resource designed to inform other users and to empower community uptake of the tool. The HFF tool, hosted at https://hfftool.com/, was developed with the support of the U.S. Department of Energy (DOE) Water Power Technologies Office (WPTO). EPRI is currently exploring alternatives to support the continued maintenance and functionally of the online tool.

13 HYDRO ENERGY↗

Power Electronics Based Self-Monitoring and Diagnosing for Photovoltaics Systems

Self-monitoring and diagnosing technology for photovoltaic (PV) systems is a method to reduce energy production losses. The proposed technology will enable existing panel-level power optimizers and inverters in a PV system to actively perturb the system, measure its response to these small-signal perturbations, and detect any changes in the small-signal impedances. Impedance measurement will be used to identify specific faults and power degradation trends in a PV panel. This information can be used to instantly alert Operations and Maintenance (O&M) personnel of the need for corrective action, thereby reducing energy production losses earlier relative to standard PV systems.

Panchal, Jeet↗

Wave energy in season: a comparative approach to feasibility of seasonal deployments for remote coastal communities

Remote coastal communities, which could be early adopters of wave energy projects, have concerns over costs, conflicts, and potential risks of development. Designers and developers are challenged to address these community concerns as they continue to develop wave energy technologies. One potential means of reducing costs, conflicts, and risks, especially for demonstration and pilot-scale projects, could be planning a deployment that operates for only a portion of the year—a seasonal deployment. Here, in this paper, we examine the impacts of a seasonal deployment in terms of cost, electricity production, operations and maintenance, environmental impacts, and community benefits. We take a holistic, comparative approach to feasibility that can be replicated for other comparative studies. We estimate electricity production using a point absorber WEC modeled near Sitka, AK, USA and optimized for the given sea conditions. We determine that, for remote community sized projects, seasonal deployments could result in small cost savings (less than 10 %), but larger decreases in annual energy production (around 30 % for our case study area). Seasonal deployments could be preferable in places with seasonal energy needs, if failures and device access become a major hindrance to wave energy technology development, or as a cautionary approach to introducing new technology to the oceans. We also determine that a highly seasonal wave resource is not necessarily a requirement for seasonal deployments to be considered. Seasonal deployments are an alternative to year-round deployments that can be considered in places where marine spatial conflict is a seasonal concern.

WEC optimizations↗

A Comprehensive Assessment Tool for Low-TRL Current Energy Converters: Preprint

Along with a market-competitive levelized cost of energy, a current energy converter technology strongly benefits from an extensive consideration of socioeconomic, environmental, and regulatory factors early in the design process. As part of a technology performance level assessment, a series of assessment questions and guidance are developed and presented to evaluate an early-stage current energy technology on holistic criteria considering the entire device lifecycle. The assessment represents an accumulation of industry and research experience to date and relies on regular updates to ensure alignment with industry best-practices, regulatory requirements, and up-to-date technical understanding. A cradle-to-grave (materials, manufacturing, installation and deployment, operations and maintenance, and end-of-life) assessment of capabilities and functional requirements for tidal, river, and ocean current technologies has been completed. This work presents the evaluation questions and qualitative performance criteria for current energy converters deployed in tidal, ocean current, and/or river applications. Key considerations related to manufacturing and installation include supply chain robustness, manufacturability and related job creation in the end-user and/or adjacent communities, and the time-to-repayment of the embodied energy debt. During deployment and maintenance operations, the safety of the device and subsystems during disconnect or grid failure, the difficulty and frequency of offshore heavy-lift activities, the avoidance or mitigation of area use conflicts, the sea-states and weather conditions that permit maintenance access, and the availability of contingency plans (should conditions change unexpectedly) are a portion of the considered assessment criteria. Results include the potential impact of early-stage design decisions on the socioeconomic, environmental, and regulatory performance of a technology that allows developers to increase the product value and probability of success, and minimize costly late-stage design iterations through early and broad consideration of factors affecting overall performance and acceptability.

industry support↗

Generation and representation of synthetic smart meter data

Advanced energy algorithms running at big-data scale will be necessary to identify, realize, and verify energy savings to meet government and utility goals of building energy efficiency. Any algorithm must be well characterized and validated before it is trusted to run at these scales. Smart meter data from real buildings will ultimately be required for the development, testing, and validation of these energy algorithms and processes. However, for initial development and testing, smart meter data are difficult to work with due to privacy restrictions, noise from unknown sources, data accessibility, and other concerns which can complicate algorithm development and validation. This paper describes a new methodology to generate synthetic smart meter data of electricity use in buildings using detailed building energy modeling, which aims to capture the variability and stochastics of real energy use in buildings. The methodology can create datasets tailored to represent specific scenarios with known truth and controllable amounts of synthetic noise. Knowledge of ground truth also allows the development and validation of enhanced processes which leverage building metadata, such as building type or size (floor area), in addition to smart meter data. The methodology described in this paper includes the key influencing factors of real-world building energy use including weather data, occupant-driven loads, building operation and maintenance practices, and special events. Data formats to support workflows leveraging both synthetic meter data and associated metadata are proposed and discussed. Finally, example use cases of the synthetic meter data are described to illustrate potential applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Windfarm Operations and Maintenance cost-Benefit Analysis Tool (WOMBAT)

This report provides technical documentation and background on the newly-developed Wind Operations and Maintenance cost-Benefit Analysis Tool (WOMBAT) software. WOMBAT is an open-source model that can be used to obtain cost estimates for operations and maintenance of land-based or offshore wind power plants. The software was designed to be flexible and modular to allow for implementation of new strategies and technological innovations for wind plant maintenance. WOMBAT uses a process-based simulation approach to model day-to-day operations, repairs, and weather conditions. High-level outputs from WOMBAT, including time-based availability and annual operating costs, are found to agree with published results from other models.

17 WIND ENERGY↗

Scientific challenges to characterizing the wind resource in the marine atmospheric boundary layer

Abstract. With the increasing level of offshore wind energy investment, it is correspondingly important to be able to accurately characterize the wind resource in terms of energy potential as well as operating conditions affecting wind plant performance, maintenance, and lifespan. Accurate resource assessment at a particular site supports investment decisions. Following construction, accurate wind forecasts are needed to support efficient power markets and integration of wind power with the electrical grid. To optimize the design of wind turbines, it is necessary to accurately describe the environmental characteristics, such as precipitation and waves, that erode turbine surfaces and generate structural loads as a complicated response to the combined impact of shear, atmospheric turbulence, and wave stresses. Despite recent considerable progress both in improvements to numerical weather prediction models and in coupling these models to turbulent flows within wind plants, major challenges remain, especially in the offshore environment. Accurately simulating the interactions among winds, waves, wakes, and their structural interactions with offshore wind turbines requires accounting for spatial (and associated temporal) scales from O(1 m) to O(100 km). Computing capabilities for the foreseeable future will not be able to resolve all of these scales simultaneously, necessitating continuing improvement in subgrid-scale parameterizations within highly nonlinear models. In addition, observations to constrain and validate these models, especially in the rotor-swept area of turbines over the ocean, remains largely absent. Thus, gaining sufficient understanding of the physics of atmospheric flow within and around wind plants remains one of the grand challenges of wind energy, particularly in the offshore environment. This paper provides a review of prominent scientific challenges to characterizing the offshore wind resource using as examples phenomena that occur in the rapidly developing wind energy areas off the United States. Such phenomena include horizontal temperature gradients that lead to strong vertical stratification; consequent features such as low-level jets and internal boundary layers; highly nonstationary conditions, which occur with both extratropical storms (e.g., nor'easters) and tropical storms; air–sea interaction, including deformation of conventional wind profiles by the wave boundary layer; and precipitation with its contributions to leading-edge erosion of wind turbine blades. The paper also describes the current state of modeling and observations in the marine atmospheric boundary layer and provides specific recommendations for filling key current knowledge gaps.

17 WIND ENERGY↗

Field Experience Detecting PV Underperformance in Real Time Using Existing Instrumentation

Maintenance at large-scale photovoltaic plants employs a mix of preventative and corrective maintenance practices. Large outages, such as an inverter tripping offline, are often easy to detect. More subtle sub-inverter faults and failures can accumulate and go unnoticed for months or years. A software-based fault detection method has been developed to analyze commonly measured data from large-scale PV plants for more timely detection of subtle underperformance. The method has been demonstrated on eight datasets from large-scale plants with high accuracy of detection. Results are validated using aerial infrared scanning. String outages are detected with a true positive rate of 73 percent and tracker issues are detected with a true positive rate of 88 percent. The developed method can be uniformly applied to photovoltaic plants across a range of scales and configurations to assess performance, quickly detect underperformance, and determine the source and location of failures. The results inform and improve operations and maintenance at PV plants, ultimately aiding in improved affordability, reliability, availability, and resiliency of solar electricity.

14 SOLAR ENERGY↗

Improving energy yield in photovoltaic modules with photonic structures

When installed outdoors, Si solar cells typically operate 20 – 30 K above ambient conditions. These elevated operating temperatures lead to diminished performance, reducing efficiency by ~0.4%/K for crystalline Si cells and decreasing module lifetime. Since much of the elevated temperature of the modules derives from parasitic absorption of sub-bandgap sunlight by the contacts, encapsulants, or other materials, reflectors that remove the sub-bandgap radiation from the module before it is absorbed promise to reduce the operating temperature. However, there are many competing strategies to reject this light: selective reflectors could be integrated into the outer module glass, at the textured Si-encapsulant interface, or on the rear. Furthermore, many of these approaches are complex and expensive to fabricate. The issue of heating can be even more critical in bifacial modules: high fractions of rear irradiance can lead to higher operating temperatures. Prior to this project, relatively little was known about the optical strategies for temperature reduction in bifacial modules. The goal of this project was to quantitatively assess optical strategies for improving the energy yield via a combination of improved anti-reflection and sub-bandgap light rejection. We studied two complementary concepts: the performance of ideal structures to determine the upper limits to performance, and low-complexity structures made from standard materials as cost-effective implementations. We also studied the performance of these reflectors in different types of modules, including Al BSF, PERC, and bifacial. Here we build from our prior accomplishments in developing mirror optimization techniques, and make use of simulation methods that accurately capture the optical properties of the modules throughout the visible and near-infrared spectrum. We connect these optical properties to energy yield under realistic, outdoor conditions. We also experimentally fabricated mirrors, incorporated them into mini-modules, and performed outdoor testing of performance at NREL. We found definitively that spectrally-selective mirrors on the outside of the module cover glass offer the best performance, both under ideal conditions and for realistic, low- complexity mirrors. Mirrors at the Si cell/encapsulant interface are limited by the multiple reflections needed to remove sub-bandgap light. Mirrors at the cell surface and mirrors on the rear also cannot remove all the sub-bandgap light, since parasitic absorption also occurs in the cover glass, encapsulant, and front contacts, depending on the module configuration. Also, cell texturing places higher demands on any cell-surface mirror because multiple interactions with the mirror are required to reject sub bandgap light which compounds losses. For bifacial modules, mirrors on the back do provide additional cooling and energy yield improvements, and the mirrors can have the same structure. In the monofacial case up to 3.3K of cooling is possible for mirrors on the front, compared to 2.2K at the cell surface and 1.2K at the rear. For bifacial modules, up to 2.4K of cooling is possible when mirrors are included at both the front and back. Our realistic designs utilize 4 – 6 layers of common photovoltaic materials such as SiO 2 , TiO 2 , and SiN x , making them more cost effective. Finally, we used our models to study thermal management in bifacial modules with different back lamination materials, finding that glass-glass laminated modules operated hotter than equivalent glass-polymer backsheet modules, due solely to the increased absorption of light incident from the rear of the module. Improving the energy yield by 2%, which is achievable with these realistic designs, would lead to LCOE reductions of $0.03/kWh by 2030. These benefits make photovoltaic panels more accessible to the public and may reduce associated maintenance costs.

14 SOLAR ENERGY↗

Emergency Diesel Generator Reliability and Installation Energy Security

The U.S. Department of Defense’s (DoD’s) fixed installations - or military bases - are a critical element of national security. Military bases support the maintenance and deployment of weapons systems, training and mobilization of combat forces, and provide direct support to combat operations. Fixed installations do not operate without energy and they rely largely on electricity to support critical missions and functions. Installations are dependent on a commercial grid that is vulnerable to disruption due to severe weather, physical attacks, and cyberattacks. This report looks at the impact on the highest priority critical loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Condition-Based Maintenance of a Circulating Water System of a Canadian Nuclear Power Plant using Machine Learning and Statistical Tools

Canada Deuterium Uranium pressurized-heavy-water reactors (PHWR) are a type of nuclear power plant that generate clean and reliable energy. The scope of this work is to automate data analysis methodologies to inform a condition-based maintenance strategy of a circulating water system (CWS) of a PHWR. The multiunit CWS provides a continuous supply of water to cool steam condensers, even during transient scenarios, thereby improving the thermal efficiency. This work aims to develop a machine learning (ML) based approach to detect anomalies in heterogeneous data of a CWS in a PHWR to help inform a predictive maintenance strategy. The heterogeneous data include textual and numeric time series data for a PHWR. Natural-language-processing (NLP)-based models are used to analyze textual data contained in work orders and operator logs and an event-timeseries correlation detection method is applied to assist anomalies diagnoses for CWS. An ML model Robust Linear Model (RLM) is also used to remove the seasonal variations in the system variable distributions based on distributions of environmental variables. A machine learning model, Density-Based Spatial Clustering of Applications with Noise (DBSCAN), trained on both original data and data without any seasonal variations will then be used to detect if an anomaly exists. Thus, by moving to an automated methodology to detect, classify, and forecast anomalies, the maintenance strategy would be based on component condition instead of a time-based schedule.

97 - MATHEMATICS AND COMPUTING↗

The Spherical Tokamak for Energy Production: theme issue introduction

This theme issue collects together papers summarising the conceptual design of the Spherical Tokamak for Energy Production (STEP). In 2019, the UK government funded the first design stages of a prototype fusion powerplant based on a compact toroidal geometry, called STEP. The primary technical aims of STEP are to produce net energy, to be self-sufficient in tritium fuel and to demonstrate a maintenance regime that would extrapolate to appropriate availability for commercial powerplants. After 5 years and over 1000 person-years of detailed scientific and engineering conceptual design, this theme issue acts as a compendium of the current design basis for STEP, noting that this is a snapshot in time and that the design will continue to evolve. This article is part of the theme issue ‘Delivering Fusion Energy – The Spherical Tokamak for Energy Production (STEP)’.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Masking of photovoltaic system performance problems by inverter clipping and other design and operational practices

We describe how performance problems can be “masked,” or not readily evident by several causes: by photovoltaic (PV) system configuration (such as the size of the PV array capacity relative to the size of the inverter and the resultant clipped operating mode); by instrumentation design, installation, and maintenance (such as a misaligned or dirty pyranometer); by contract clauses (when operational availability is transformed to contractual availability, which excludes many factors); and by identified management and operational practices (such as reporting on a portfolio of plants rather than individually). A simple method based on a duration curve is introduced to overcome shortcomings of Performance Ratio based on nameplate capacity and Performance Index based on hourly simulation when quantifying masking effects, and inverter clipping and pyranometer soiling are presented as two examples of the new method. With a better understanding of the non-transparency of masking issues, stakeholders can better interpret performance data and deliver improved AC and DC plant conditions through PV system operation and maintenance (O&M) for improved performance, reduced O&M costs, and a more consistently delivered, and reduced, levelized cost of energy (LCOE).

14 SOLAR ENERGY↗

Review of wake management techniques for wind turbines

Summary The progression of wind turbine technology has led to wind turbines being incredibly optimized machines often approaching their theoretical maximum production capabilities. When placed together in arrays to make wind farms, however, they are subject to wake interference that greatly reduces downstream turbines' power production, increases structural loading and maintenance, reduces their lifetimes, and ultimately increases the levelized cost of energy. Development of techniques to manage wakes and operate larger and larger arrays of turbines more efficiently is now a crucial field of research. Herein, four wake management techniques in various states of development are reviewed. These include axial induction control, wake steering, the latter two combined, and active wake control. Each of these is reviewed in terms of its control strategies and use for power maximization, load reduction, and ancillary services. By evaluating existing research, several directions for future research are suggested.

17 WIND ENERGY↗