Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Potential Annealing Treatments for Tailoring the Starting Microstructure of Low-Enriched U-Mo Dispersion Fuels to Optimize Performance During Irradiation

Low-enriched uranium-molybdenum alloy particles dispersed in aluminum alloy (e.g., dispersion fuels) are being developed for application in research and test reactors. To achieve the best performance of these fuels during irradiation, optimization of the starting microstructure may be required by utilizing a heat treatment that results in the formation of uniform, Si-rich interaction layers between the U-Mo particles and Al-Si matrix. These layers behave in a stable manner under certain irradiation conditions. To identify the optimum heat treatment for producing these kinds of layers in a dispersion fuel plate, a systematic annealing study has been performed using actual dispersion fuel samples, which were fabricated at relatively low temperatures to limit the growth of any interaction layers in the samples prior to controlled heat treatment. These samples had different Al matrices with varying Si contents and were annealed between 450 and 525 C for up to 4 hours. The samples were then characterized using scanning electron microscopy (SEM) to examine the thickness, composition, and uniformity of the interaction layers. Image analysis was performed to quantify various attributes of the dispersion fuel microstructures that related to the development of the interaction layers. The most uniform layers were observed to form in fuel samples that had an Al matrix with at least 4 wt% Si and a heat treatment temperature of at least 475 C.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pu239 Cross-Section Variations Based on Experimental Uncertainties and Covariances

Algorithms and software have been developed for producing variations in plutonium-239 neutron cross sections based on experimental uncertainties and covariances. The varied cross-section sets may be produced as random samples from the multi-variate normal distribution defined by an experimental mean vector and covariance matrix, or they may be produced as Latin-Hypercube/Orthogonal-Array samples (based on the same means and covariances) for use in parametrized studies. The variations obey two classes of constraints that are obligatory for cross-section sets and which put related constraints on the mean vector and covariance matrix that detemine the sampling. Because the experimental means and covariances do not obey some of these constraints to sufficient precision, imposing the constraints requires modifying the experimental mean vector and covariance matrix. Modification is done with an algorithm based on linear algebra that minimizes changes to the means and covariances while insuring that the operations that impose the different constraints do not conflict with each other.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty evaluation for the matrix 'solidified state' of fissionable elements

In case of the analysis of the radioactive liquid samples, no matter the relative physical analysis method used, two impediments act that belong to the behavior in time of the dispersion state of the liquid samples to be analyzed and of the standard used in the analysis. That is, one of them refers to the state of the sample to be analyzed when being sampled, which 'alter' during the time elapsed from sampling up to the analysis of the sample. The other impediment is the natural change of the dispersion state of the standard radioactive solutions, due to the occurrence and evolution in time of the radiocolloidal and pseudo-radiocolloidal states. These radiocolloidal states are states of aggregation and they lead to the destruction of the homogeneity of the solutions. Taking into consideration the advantages offered by the relative physical methods of analysis as against the chemical or the radiochemical ones, different ways of eliminating these impediments have been tried. We eliminated these impediments processing the liquid reference materials (the solutions calibrated in radionuclides of interest), immediately after the preparation. This processing changes the liquid physical state of the reference materials in a 'solidified state'. Through this procedure the dispersion states of the samples, practically, can no longer be essentially modified in time and also ensure the uniform distribution of the radionuclides of interest in the elemental matrix of the samples 'state solidified'. The homogeneity of the distribution of the atoms of the radionuclides from the samples 'solidified state' was checked up through the track micromapping technique of the alpha particles. Through this technique, in the chemically etched track detectors that were put in direct contact with the sample for a determined period of time, the alpha exposure time of the detectors, micromaps of alpha tracks were obtained. These micromaps are retorts through tracks of the distributions atoms of fissionable elements (Thorium e.g.), of which, heavy charged particles, in this case the alpha radiations naturally emitted, were registered in the CR-39 track detectors. The density of alpha track from the obtained track micromaps was studied through common optic microscopy. Micromaps were studied counting the tracks on equal areas, in different measurement points. For the study of the foils prepared within the paper, the studied area was of 4.9 mm2, formed of 10 fields of 0.49 mm2 area each. The estimation of the uncertainty was carried out for all the sizes that were measured within the paper, no matter if they participate, directly or indirectly, in the estimation of the uncertainty regarding the homogeneity of the Thorium atoms distribution in the 'solidified state' foils of the standard solution calibrated in Thorium, such as: i) the weighted masses, ii) the dropped volumes of solution, iii) the alpha duration of exposure of the detectors, iv) the area studied on the surface of the micromap and v) the densities of alpha tracks. The procedure suggested allowed us to considerate that the homogeneity of alpha tracks distribution, on the surface and in thickness, is within the limits of 3.1%.

36 MATERIALS SCIENCE↗

Demonstration of Complete Recycling Processes of Reversible Epoxies Using Solar Energy Conversion

Reversible epoxies using the Diels–Alder chemistry enables recycling processes through depolymerizing the polymer at higher temperature and then repolymerizing upon cooling. Compared to conventional bulk heating, photothermal heating can save time and resource and, consequently, reduce costs to reach an elevated temperature for recycling processes of the reversible epoxies. In previous studies, self‐healing of cracks and reattachments of two broken pieces have been presented using a laser; however, recycling of a sample as a whole is not feasible by using such a point light source. Herein, complete recycling processes are demonstrated utilizing an area light source, i.e., sunlight. Reversible epoxies are incorporated with carbon black and refractory plasmonic titanium nitride nanoparticles (NPs). Under concentrated (10 times) sunlight, they can generate sufficient heat (≈140 °C) to completely liquefy, reprocess, and reshape the samples multiple times. Recycling processes are validated by evaluation of mechanical properties for each cycle. Using an integrated experimental and theoretical approach, photothermal performance is investigated in terms of the dispersion and loading of photothermal NPs in the matrix, as well as the sample thickness. In this study, an insight is provided into the design of polymer/photothermal nanomaterial composites which can be sustainably recycled using abundant solar energy.

14 SOLAR ENERGY↗

The HANDE-QMC Project: Open-Source Stochastic Quantum Chemistry from the Ground State Up

Building on the success of Quantum Monte Carlo techniques such as diffusion Monte Carlo, alternative stochastic approaches to solve electronic structure problems have emerged over the past decade. The full configuration interaction quantum Monte Carlo (FCIQMC) method allows one to systematically approach the exact solution of such problems, for cases where very high accuracy is desired. The introduction of FCIQMC has subsequently led to the development of coupled cluster Monte Carlo (CCMC) and density matrix quantum Monte Carlo (DMQMC), allowing stochastic sampling of the coupled cluster wave function and the exact thermal density matrix, respectively. In this Article, we describe the HANDE-QMC code, an open-source implementation of FCIQMC, CCMC and DMQMC, including initiator and semistochastic adaptations. We describe our code and demonstrate its use on three example systems; a molecule (nitric oxide), a model solid (the uniform electron gas), and a real solid (diamond). An illustrative tutorial is also included.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extraction chromatographic separations of tantalum and tungsten from hafnium and complex matrix constituents

Ta, Hf, and W analyses from complex matrices (including environmental samples) require high purification of these analytes from each other and major/trace matrix constituents, however, current state-of-the-art Ta/Hf/W separations rely on traditional anion exchange approaches that suffer from relatively similar distribution coefficient (Kd) values for these analytes. This work reports assessment of three commercially available extraction chromatographic resins (TEVA, TRU, and UTEVA) for Ta/Hf/W separations. Batch contact studies show differences in Ta/W,Hf Kd values of up to 106, representing an improvement of a factor of 100 and 300 in Ta/Hf and Ta/W Kd values (respectively) over AG1x4 resin. Variations in the Kd values as a function of HCl concentration for TRU resin show that this resin is well suited for Ta/Hf/W separations, with Ta/Hf, Ta/W, and W/Hf Kd value improvements of 10, 200, and 30 (respectively) over AG1x4 resin. Finally, analyses of digested soil samples (NIST 2710a) using TRU resin and tandem TEVA-TRU columns demonstrate the ability to achieve extremely high purification (>99%) of Ta and W from each other and Hf, as well as enabling very high purification of Ta and W from the major and trace elemental constituents present in soils, using a single chromatographic step.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radiation induced amorphization of carbides in additively manufactured and conventional ferritic-martensitic steels: In-situ experiments on extraction replicas

In-situ irradiations using 1 MeV Kr 2+ ions in a transmission electron microscope were performed on extraction replica samples containing M 23 C 6 carbides and MX carbonitrides from two ferritic-martensitic (FM) steels: (i) 9%Cr-1%W-TaV based Eurofer97 and (ii) 9%Cr-1%Mo-VNb (all in wt.%) based additively manufactured (AM) Grade91 steel. The irradiations were performed between 100 and 773 K up to a maximum dose of ~2.4 displacements per atom (dpa). The M 23 C 6 carbides are highly susceptible to radiation induced amorphization (RIA), while the MX type nanoprecipitates are highly amorphization resistant across the entire irradiation temperature range. Between 100 and 423 K, RIA of M 23 C 6 carbides occurs very rapidly with critical amorphization doses ranging between ~0.35 and 0.9 dpa, increasing to higher doses at 573 K. Complete amorphization of the M 23 C 6 carbides up to doses of ~2.4 dpa is not possible at 773 K under the present irradiation conditions. The critical amorphization dose of M 23 C 6 carbides increases nearly exponentially with irradiation temperature. The critical temperature for the crystalline-to-amorphous phase transformation (T c→a ) of M 23 C 6 carbides irradiated as replica samples, i.e. without the surrounding metal matrix, was estimated to be ~812 K. Comparing the present results with neutron irradiation data on bulk samples reveals a decrease in the critical amorphization dose for M 23 C 6 and an increase of T c→a , highlighting the effect of dose rate on the amorphization behavior that is qualitatively consistent with literature on other non-metals. Changes in the minor chemistry of M 23 C 6 , such as presence or absence of W, V, Nb, Mo, seems to have little effect on the amorphization behavior. Here, in-situ irradiations on extraction replica samples provide a novel pathway to explore radiation tolerance of nanoprecipitates in nuclear structural materials

36 MATERIALS SCIENCE↗

Path integral density matrix dynamics: A method for calculating time-dependent properties in thermal adiabatic and non-adiabatic systems

We introduce a new approach for calculating quantum time-correlation functions and time-dependent expectation values in many-body thermal systems; both electronically adiabatic and non-adiabatic cases can be treated. Our approach uses a path integral simulation to sample an initial thermal density matrix; subsequent evolution of this density matrix is equivalent to solution of the time-dependent Schrödinger equation, which we perform using a linear expansion of Gaussian wavepacket basis functions which evolve according to simple classical-like trajectories. Overall, this methodology represents a formally exact approach for calculating time-dependent quantum properties; by introducing approximations into both the imaginary-time and real-time propagations, this approach can be adapted for complex many-particle systems interacting through arbitrary potentials. We demonstrate this method for the spin Boson model, where we find good agreement with numerically exact calculations. We also discuss future directions of improvement for our approach with a view to improving accuracy and efficiency.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-Pressure X-ray Tomography Microscope: Synchrotron Computed Microtomography at High Pressure and Temperature

A new apparatus has been developed for microtomography studies under high pressure. The pressure generation mechanism is based on the concept of the widely used Drickamer anvil apparatus, with two opposed anvils compressed inside a containment ring. Modifications are made with thin aluminum alloy containment rings to allow transmission of x rays. Pressures up to 8 GPa have been generated with a hydraulic load of 25 T. The modified Drickamer cell is supported by thrust bearings so that the entire pressure cell can be rotated under load. Spatial resolution of the high pressure tomography apparatus has been evaluated using a sample containing vitreous carbon spheres embedded in FeS matrix, with diameters ranging from 0.01 to 0.2 mm. Spheres with diameters as small as 0.02 mm were well resolved, with measured surface-to-volume ratios approaching theoretical values. The sample was then subject to a large shear strain field by twisting the top and bottom Drickamer anvils. Imaging analysis showed that detailed microstructure evolution information can be obtained at various steps of the shear deformation, allowing strain partition determination between the matrix and the inclusions. A sample containing a vitreous Mg{sub 2}SiO{sub 4} sphere in FeS matrix was compressed to 5 GPa, in order to evaluate the feasibility of volume measurement by microtomography. The results demonstrated that quantitative inclusion volume information can be obtained, permitting in situ determination of P-V-T equation of state for noncrystalline materials.

43 PARTICLE ACCELERATORS↗

Nanomechanical sampling of material for nanoscale mass spectrometry chemical analysis

The ability to spatially resolve the chemical distribution of compounds on a surface is important in many applications ranging from biological to material science. To this extent, we have recently introduced a hybrid atomic force microscopy (AFM)-mass spectrometry (MS) system for direct thermal desorption and pyrolysis of material with nanoscale chemical resolution. However, spatially resolved direct surface heating using local thermal desorption becomes challenging on material surfaces with low melting points, because the material will undergo a melting phase transition due to heat dissipation prior to onset of thermal desorption. Therefore, here we developed an approach using mechanical sampling and collection of surface materials on an AFM cantilever probe tip for real-time analysis directly from the AFM tip. This approach allows for material to be concentrated directly onto the probe for subsequent MS analysis. We evaluate the performance metrics of the technique and demonstrate localized MS sampling from a candelilla wax matrix containing UV stabilizers avobenzone and oxinoxate from areas down to 250 nm × 250 nm. Overall, this approach removes heat dissipation into the bulk material allowing for a faster desorption and concentration of the gas phase analyte from a single heating pulse enabling higher signal levels from a given amount of material in a single sampling spot.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Influence of MS Imaging Parameters on UV-MALDI Desorption and Ion Yield

Ultraviolet matrix-assisted laser desorption/ionization mass spectrometry imaging (UV-MALDI MSI) is a widely used technique for imaging molecular distributions within biological systems. While much work exists concerning desorption in UV-MALDI MS, the effects of commonly varied parameters for imaging applications (repetition rate, use of continuous raster mode and raster speed), which determine spatial resolution and limits of detection for the technique, remain largely unknown. We use multiple surface characterization modalities to obtain quantitative measurements of material desorption and analyte ion yield in thin film model systems of two matrix compounds, arising from different UV-MALDI MSI sampling conditions. Observed changes in resulting ablation feature point to matrix-dependent spatial resolution and laser-induced matrix modification effects. Analyte ion yields of 10{sup −9} to 10{sup −6} are observed. Complex changes in ion yield, between spot and raster sampling and arising from varied laser repetition rate and raster speed, are observed. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Topological and thermal properties of polypropylene composites based on oil palm biomass

Roughness on pristine and polymer composite surfaces is of enormous practical importance for polymer applications. This study deals with the use of varying quantity of oil palm ash as a nanofiller in a polypropylene based matrix. The oil palm ash sample was preprocessed to break the particles into small diameter by using ultra sonication before using microfluidizer for further deduction in size and homogenization. The oil palm ash was made to undergo many passes through the microfluidizer for fine distribution of particles. Polypropylene based composites containing different loading percentage oil palm ash was granulated by twin screw extruder and then injection molded. The surface morphology of the OPA passed through microfluidizer was analyzed by Tapping Mode - Atomic Force Microscopy (TMAFM). Thermal analysis results showed an increase in the activation energy values. The thermal stability of the composite samples showed improvement as compared to the virgin polymer as corroborated by the on-set degradation temperatures and the temperatures at which 50% degradation occurred.

36 MATERIALS SCIENCE↗

Comparison of experimental methods for estimating matrix diffusion coefficients for contaminant transport modeling

Here, diffusion cell and diffusion wafer experiments were conducted to compare methods for estimating effective matrix diffusion coefficients in rock core samples from Pahute Mesa at the Nevada Nuclear Security Site (NNSS). A diffusion wafer method, in which a solute diffuses out of a rock matrix that is pre-saturated with water containing the solute, is presented as a simpler alternative to the traditional through-diffusion (diffusion cell) method. Both methods yielded estimates of effective matrix diffusion coefficients that were within the range of values previously reported for NNSS volcanic rocks. The difference between the estimates of the two methods ranged from 14 to 30%, and there was no systematic high or low bias of one method relative to the other. From a transport modeling perspective, these differences are relatively minor when one considers that other variables (e.g., fracture apertures, fracture spacings) influence matrix diffusion to a greater degree and tend to have greater uncertainty than effective matrix diffusion coefficients. For the same relative random errors in concentration measurements, the diffusion cell method yields effective matrix diffusion coefficient estimates that have less uncertainty than the wafer method. However, the wafer method is easier and less costly to implement and yields estimates more quickly, thus allowing a greater number of samples to be analyzed for the same cost and time. Given the relatively good agreement between the methods, and the lack of any apparent bias between the methods, the diffusion wafer method appears to offer advantages over the diffusion cell method if better statistical representation of a given set of rock samples is desired.

54 ENVIRONMENTAL SCIENCES↗

Renewable Surface Fluorescence Sandwich Immunoassay Biosensor for Rapid Sensitive Botulinum Toxin Detection in an Automated Fluidic Format

A renewable surface biosensor for rapid detection of botulinum toxin is described based on fluidic automation of a fluorescence sandwich immunoassay, using a recombinant fragment of the toxin heavy chain as a structurally valid simulant. Monoclonal antibodies AR4 and RAZ1 bind to separate epitopes of both this fragment and the holotoxin. The AR4 antibody was covalently bound to Sepharose beads and used as the capture antibody. A rotating rod flow cell was used to capture these beads delivered as a suspension by the sequential injection flow system, creating a 3.6 microliter column. After perfusing the bead column with sample and washing away the matrix, the column was perfused with Alexa 647 dye-labeled RAZ1 antibody as the reporter. Optical fibers coupled to the rotating rod flow cell at a 90 degree angle to one another delivered excitation light from a HeNe laser and collected fluorescent emission light for detection. After each measurement, the used sepharose beads are released and replaced with fresh beads. In a rapid screening approach to sample analysis, the toxin simulant was detected to concentrations of 10 pM in less than 20 minutes.

59 BASIC BIOLOGICAL SCIENCES↗

Studies on the Composite System of Bi-2212 Glass Ceramic and MgB{sub 2} Superconductors

The composites of glass ceramic Bi-2212 and MgB{sub 2} superconductors were prepared at ambient conditions. The transmission electron microscopy images of the composite samples illustrate the presence of glass ceramic inclusions in bulk MgB{sub 2}. Temperature-dependent magnetization of the composite samples shows two superconducting transitions: one at 80 K corresponding to the Bi-2212 phase and a second one at 39 K corresponding to the MgB{sub 2} phase, suggesting that the two superconducting phases are separated with clear boundaries. The critical current density (J{sub c}) and pinning force values are increased in composite systems by an order of magnitude compared to that of individual samples. The pinning mechanism in the composite sample is the same as in the matrix phase. Reduced field maxima (h{sub max}) are observed at 0.15 for composite samples. A low value of h{sub max} for composite samples indicates the random orientation of grain boundaries and repulsive pinning force in the composite samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of the Emissions and Crystalline Silica Content of Airborne Dust Generated from Grinding Natural and Engineered Stones

Abstract In this study, we systematically characterized the airborne dust generated from grinding engineered and natural stone products using a laboratory testing system designed and operated to collect representative respirable dust samples. Four stone samples tested included two engineered stones consisting of crystalline silica in a polyester resin matrix (formulations differed with Stones A having up to 90wt% crystalline silica and Stone B up to 50wt% crystalline silica), an engineered stone consisting of recycled glass in a cement matrix (Stone C), and a granite. Aerosol samples were collected by respirable dust samplers, total dust samplers, and a Micro-Orifice Uniform Deposit Impactor. Aerosol samples were analyzed by gravimetric analysis and x-ray diffraction to determine dust generation rates, crystalline silica generation rates, and crystalline silica content. Additionally, bulk dust settled on the floor of the testing system was analyzed for crystalline silica content. Real-time particle size distributions were measured using an Aerodynamic Particle Sizer. All stone types generated similar trimodal lognormal number-weighted particle size distributions during grinding with the most prominent mode at an aerodynamic diameter of about 2.0-2.3 μm, suggesting dust formation from grinding different stones is similar. Bulk dust from Stone C contained no crystalline silica. Bulk dust from Stone A, Stone B, and granite contained 60, 23, and 30wt% crystalline silica, respectively. In Stones A and B, the cristobalite form of crystalline silica was more plentiful than the quartz form. Only the quartz form was detected in granite. The bulk dust, respirable dust, and total dust for each stone had comparable amounts of crystalline silica, suggesting that crystalline silica content in the bulk dust could be representative of that in respirable dust generated during grinding. Granite generated more dust per unit volume of material removed than the engineered stones, which all had similar normalized dust generation rates. Stone A had the highest normalized generation rates of crystalline silica, followed by granite, Stone B, and Stone C (no crystalline silica), which likely leads to the same trend of respirable crystalline silica (RCS) exposure when working with these different stones. Manufacturing and adoption of engineered stone products with formulations such as Stone B or Stone C could potentially lower or eliminate RCS exposure risks. Combining all the effects of dust generation rate, size-dependent silica content, and respirable fraction, the highest normalized generation rate of RCS consistently occurs at 3.2-5.6 µm for all the stones containing crystalline silica. Therefore, removing particles in this size range near the generation sources should be prioritized when developing engineering control measures.

Public, Environmental & Occupational Health↗

Comparison of Experimental Methods for Estimating Matrix Diffusion Coefficients for Contaminant Transport Modeling

Diffusion cell and diffusion wafer experiments were conducted to compare methods for estimating matrix diffusion coefficients in rock core samples from Pahute Mesa at the Nevada Nuclear Security Site (NNSS). A diffusion wafer method, in which a solute diffuses out of a rock matrix that is pre-saturated with water containing the solute, is presented as a simpler alternative to the traditional through-diffusion (diffusion cell) method. Both methods yielded estimates of matrix diffusion coefficients that were within the range of values previously reported for NNSS volcanic rocks. The difference between the estimates of the two methods ranged from 14 to 30%, and there was no systematic high or low bias of one method relative to the other. From a transport modeling perspective, these differences are relatively minor when one considers that other variables (e.g., fracture apertures, fracture spacings) influence matrix diffusion to a greater degree and tend to have greater uncertainty than diffusion coefficients. For the same relative random errors in concentration measurements, the diffusion cell method yields diffusion coefficient estimates that have less uncertainty than the wafer method. However, the wafer method is easier and less costly to implement and yields estimates more quickly, thus allowing a greater number of samples to be analyzed for the same cost and time. Given the relatively good agreement between the methods, and the lack of any apparent bias between the methods, the diffusion wafer method appears to offer advantages over the diffusion cell method if better statistical representation of a given set of rock samples is desired.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Determination of transition metal ions in fossil fuel associated wastewaters using chelation ion chromatography

Here, this study outlines the development and subsequent validation of a method using chelation ion chromatography (CIC) pretreatment followed by traditional ion chromatography (IC) and post column UV/vis detection to measure transition metals in fossil fuel wastewaters, such as oil & gas (O&G) brines and coal mine drainage (CMD) waters. Measurement of transition metals is often an important characterization step in the research of environmental and energy systems. IC represents one way to measure these metals with the advantages of being versatile, simple and relatively low cost compared to other analytical methods. However, high concentrations of alkali and alkaline earth metals present in fossil fuel wastewaters will decrease IC detectability of transition metals in these waters. In this study, a CIC method was developed for the analysis of transition metal ions (Fe 3+ , Cu 2+ , Ni 2+ , Zn 2+ , Co 2+ , Mn 2+ , and Fe 2+ ) in fossil fuel associated wastewaters such as Appalachian CMD and O&G wastewaters from the Permian and Bakken shale basins in the United States. CIC system incorporated an on-line chelator column (e.g., the MetPac CC-1) with high selectivity for transition metals over alkali and alkaline earth metals for salt matrix removal prior to transition metal separation and detection. Additional method developments also included acidifying all samples to 2% v/v HCl and using gradient elution rather than isocratic. The recoverability of transition metals in simple salt solutions commonly found in CMD and brine samples (e.g. NaCl, Na 2 SO 4 , CaCl 2 ) using CIC was evaluated and compared to that using traditional IC. Our results found that the CIC system significantly improved transition metal recoveries for samples in 10,000 mg/L CaCl 2 matrix, reaching 87%-108% recovery for all analytes, as opposed to 2-323% recovery in traditional IC. The limits of detection in this study achieved 10.09 – 161.2 μg/L, comparable to reported values in similar IC studies. The developed method was also verified with certified water samples, resulting in 89% - 111% recoveries in samples with higher analyte concentrations (i.e. >4x the LoDs). The developed method achieved 87% -112% recoveries for most analytes in CMD samples and 72%-138% recoveries for Bakken shale samples, relative to ICP-MS values. Overall, the current IC method can be a very good screening tool for fast and cheap analysis for transition metals at mg/L level, to facilitate selection of samples for more detailed ICP-MS analysis.

01 COAL, LIGNITE, AND PEAT↗