Search NASA⌕ Search

SEARCH · Search NASA

Results for “micro level”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Accelerated Near-Threshold Fatigue Crack Growth Behavior of an Aluminum Powder Metallurgy Alloy

Fatigue crack growth (FCG) research conducted in the near threshold regime has identified a room temperature creep crack growth damage mechanism for a fine grain powder metallurgy (PM) aluminum alloy (8009). At very low DK, an abrupt acceleration in room temperature FCG rate occurs at high stress ratio (R = Kmin/Kmax). The near threshold accelerated FCG rates are exacerbated by increased levels of Kmax (Kmax less than 0.4 KIC). Detailed fractographic analysis correlates accelerated FCG with the formation of crack-tip process zone micro-void damage. Experimental results show that the near threshold and Kmax influenced accelerated crack growth is time and temperature dependent.

Piascik, Robert S.↗

Semiselective Optoelectronic Sensors for Monitoring Microbes

Sensor systems are under development for use in real-time detection and quantitation of microbes in water without need for sampling. These systems include arrays of optical sensors; miniature, portable electronic data-acquisition circuits; and optoelectronic interfaces between the sensor arrays and data-acquisition circuits. These systems are intended for original use in long-term, inline monitoring of waterborne micro-organisms in water-reclamation systems aboard future spacecraft. They could also be adapted to similar terrestrial uses with respect to municipal water supplies, stored drinking water, and swimming water; for detecting low-level biological contamination in biotechnological, semiconductor, and pharmaceutical process streams; and in verifying the safety of foods and beverages. In addition, they could be adapted to monitoring of airborne microbes and of surfaces (e.g., to detect and/or quantitate biofilms). The designs of the sensors in these systems are based partly on those of sensors developed previously for monitoring airborne biological materials. The designs exploit molecular- recognition and fluorescence-spectroscopy techniques, such that in the presence of micro-organisms of interest, fluorescence signals change and the changes can be measured. These systems are characterized as semiselective because they respond to classes of micro-organisms and can be used to discriminate among the classes. This semiselectivity is a major aspect of the design: It is important to distinguish between (1) the principle of detection and quantitation of classes of micro-organisms by use of these sensors and (2) the principle of detection and quantitation of individual microbiological species by means of prior immuno-diagnostic and/or molecular-biology techniques. Detection of classes (in contradistinction to species) is particularly valuable when the exact nature of a contaminant is unknown.

Tabacco, Mary Beth↗

Effect of Gravity on the Mammalian Cell Deformation

The effect of human cell immersed in culture liquid under a micro-gravity environment has been investigated. The study is based on the numerical simulation of the configuration of human cell affected by the time dependent variation of gravity acceleration ranging from 10(exp -3) to 2 g(sub o) (g(sub o) = 9.81 m/s(exp 2)) in 15 seconds. Both the free floating cell and the cell contacted to the upper and lower inclined walls imposed by the time-dependent reduced gravity acceleration are considered in this study. The results show that the cell configuration changes from spherical to horizontally elongated ellipsoid for both the free floating cell and the cell sitting on the lower inclined wall while the cell configuration varies from spherical to vertically elongated ellipsoid for the cell hanging to the upper inclined wall when the gravity acceleration increases. Experimental observations, carried out of human cells exposed to the variation of gravity levels, show that the results of experimental observations agree exactly with the theoretical model computation described in this paper. These results sre significant for humans exposed to the micro-gravity environment.

Hung, R. J.↗

Restoring and Maintaining Bone in Osteopenic Female Rat Skeleton: Changes in Bone Mass and Structure - Part 1

This experiment contains the crucial data for the lose, restore, and maintain (LRM) concept, a practical approach for reversing existing osteoporosis. The LRM concept uses anabolic agents to restore bone mass and architecture (+ phase) and then switches to an agent with the established ability to maintain bone mass, to keep the new bone (+/- phase). The purpose of this study was to learn whether switching to an agent known chiefly for its ability to maintain existing bone mass preserves new bone induced by PGE2, in osteopenic,estrogen-depleted rats. The current study had three phases, the bone loss (-), restore (+), and maintain (+/-) phases. We ovariectomized (OX) or sham ovariectomized (sham-OX) 5.5 month-old female rats (- phase). The OX rats were treated 5 months postovariectomy with 1-6 mg PGE2, per kg/day for 75 days to restore lost cancellous bone mass (+ phase), and then PGE2, treatment was stopped and treatment began with 1 or 5 micro-g/kg of risedronate, a bisphosphonate, twice a week for 60 days (+/- phase). During the loss (-) phase, the cancellous bone volume of the proximal tibial metaphysis in the OX rat fell to 19% of initial and 30% of age-matched control levels. During the restore (+) phase, the cancellous bone volume in OX rats doubled. When PGE2 treatment was stopped, however, and no special maintenance efforts were made during the maintain (+/-) phase, the PGE2-induced cancellous bone disappeared. In contrast, the PGE2-induced cancellous bone persisted when the PGE2 treatment was followed by either a 1 or 5 micro-g treatment of risedronate per kg given twice a week for 60 days during the maintain (+/-) phase. The tibial shaft demonstrated very little cortical bone loss during the loss (-) phase in OX rats. The tibial shaft cortical bone fell some 8%. During the restore (+) phase, new cortical bone in OX rats increased by 22%. When PGE2 treatment was stopped and nothing was given during the maintain (+/-) phase, however, all but the PGE2-induced subperiosteal bone disappeared. In contrast, when PGE2 treatment was stopped and 1 micro-g risedronate per kg twice a week for 60 days was administered during the maintenance (+/-) phase, the PGE2-induced subperiosteal bone and some of the subendocortical bone and marrow trabeculae persisted. When 5 micro-g risedronate per kg was given twice a week, all the PGE2-induced bone persisted. The study shows that most of the new cancellous and cortical bone induced by PGE2, can be maintained for at least 60 days after discontinuing PGE2 by administering enough of the resorption inhibitor, risedronate. The lower dose of risedronate was not adequate to save most of the PGE2-induced endocortical bone.

Tang, Li Ya↗

Full Field X-Ray Fluorescence Imaging Using Micro Pore Optics for Planetary Surface Exploration

Many planetary surface processes leave evidence as small features in the sub-millimetre scale. Current planetary X-ray fluorescence spectrometers lack the spatial resolution to analyse such small features as they only provide global analyses of areas greater than 100 mm(exp 2). A micro-XRF spectrometer will be deployed on the NASA Mars 2020 rover to analyse spots as small as 120m. When using its line-scanning capacity combined to perpendicular scanning by the rover arm, elemental maps can be generated. We present a new instrument that provides full-field XRF imaging, alleviating the need for precise positioning and scanning mechanisms. The Mapping X-ray Fluorescence Spectrometer - "Map-X" - will allow elemental imaging with approximately 100μm spatial resolution and simultaneously provide elemental chemistry at the scale where many relict physical, chemical and biological features can be imaged in ancient rocks. The arm-mounted Map-X instrument is placed directly on the surface of an object and held in a fixed position during measurements. A 25x25 mm(exp 2) surface area is uniformly illuminated with X-rays or alpha-particles and gamma-rays. A novel Micro Pore Optic focusses a fraction of the emitted X-ray fluorescence onto a CCD operated at a few frames per second. On board processing allows measuring the energy and coordinates of each X-ray photon collected. Large sets of frames are reduced into 2d histograms used to compute higher level data products such as elemental maps and XRF spectra from selected regions of interest. XRF spectra are processed on the ground to further determine quantitative elemental compositions. The instrument development will be presented with an emphasis on the characterization and modelling of the X-ray focussing Micro Pore Optic. An outlook on possible alternative XRF imaging applications will be discussed.

micro-XRF spectrometer↗

Study of Contact Resistances in Integrated Circuits

Techniques explored in search for rapid, reliable test. Resistances of aluminum/silicon contacts and methods to measure subjects of NASA report. Study with three tasks undertaken to evaluate nature and reliability of large numbers of semiconductor contacts of type now being fabricated in integrated circuits: Develop yield analysis for series strings of contacts using wafer-level electrical measurements, and identify different types of faults by visual inspection; develop wafer-level tests to evaluate reliability of contact strings; and develop mathematical model for current flow in contacts and examine contact region for evidence of micro-alloying.

Buehler, M. G.↗

Containerless protein crystal growth method

A method of growing protein crystals from levitated drops is introduced and unique features of containerless approach in 1-g and micro-G laboratories are discussed. Electrostatic multidrop levitation system which is capable of simultaneous four drop levitation is described. A method of controlling protein saturation level in a programmed way is introduced and discussed. Finally, some of the unique features of containerless approach of protein crystal growth in space are discussed and summarized.

Rhim, Won-Kyu↗

Controller Design for the ST7 Disturbance Reduction System

The Space Technology 7 experiment will perform an on-orbit system-level validation of two specific Disturbance Reduction System technologies: a gravitational reference sensor employing a free-floating test mass and a set of micro-Newton colloidal thrusters. The Disturbance Reduction System is designed to maintain a spacecraft's position with respect to the free-floating test mass to less than 10 nm/ square root of Hz, over the frequency range 10(exp -3) Hz to 10(exp -2) Hz. This paper presents the design and analysis of the coupled drag-free and attitude control system that closes the loop between the gravitational reference sensor and the micro-Newton thrusters while incorporating star tracker data at low frequencies. The effects of actuation and measurement noise and disturbances on the spacecraft and test masses are evaluated in a seven-degree-of-freedom planar model incorporating two translational and one rotational degrees of freedom for the spacecraft and two translational degrees of freedom for each test mass.

Maghami, Peiman↗

Disturbance Reduction Control Design for the ST7 Flight Validation Experiment

The Space Technology 7 experiment will perform an on-orbit system-level validation of two specific Disturbance Reduction System technologies: a gravitational reference sensor employing a free-floating test mass, and a set of micro-Newton colloidal thrusters. The ST7 Disturbance Reduction System is designed to maintain the spacecraft's position with respect to a free-floating test mass to less than 10 nm/Hz, over the frequency range of 1 to 30 mHz. This paper presents the design and analysis of the coupled, drag-free and attitude control systems that close the loop between the gravitational reference sensor and the micro-Newton thrusters, while incorporating star tracker data at low frequencies. A full 18 degree-of-freedom model, which incorporates rigid-body models of the spacecraft and two test masses, is used to evaluate the effects of actuation and measurement noise and disturbances on the performance of the drag-free system.

Maghami, P. G.↗

Control Modes of the ST7 Disturbance Reduction System Flight Validation Experiment

The Space Technology 7 experiment will perform an on-orbit system-level validation of two specific Disturbance Reduction System technologies: a gravitational reference sensor employing a free-floating test mass and a set of micro-Newton colloidal thrusters. The ST7 Disturbance Reduction System is designed to maintain the spacecraft s position with respect to a free-floating test mass to less than 10 nm/the square root of Hz over the frequency range of 1 to 30 mHz. This requirement will help ensure that the residual accelerations on the test masses (beyond gravitational acceleration) will be below the ST7 goal of 300 (1 + [f/3 mHz](sup 2)) pm/s(sup 2)/the square root of Hz. This paper presents the overall design and analysis of the spacecraft drag-free and attitude controllers being designed by NASA s Goddard Space Flight Center. These controllers close the loop between the GRS and the micro-Newton colloidal thrusters. The ST7 DRS comprises three control systems: the attitude control system to maintain a sun-pointing attitude, the drag free control to center the spacecraft about the test masses, and the test mass suspension control. There are five control modes in the operation of the ST7-DRS, starting from the attitude-only mode and leading to the challenging science mode. The design and analysis of each of the control modes are presented. An 18-DOF model is developed to capture the essential dynamics of the ST7-DRS package. It includes all rigid-body dynamics of the spacecraft and two test masses (three translations and three rotations for the spacecraft and each of the test masses). Actuation and measurement noise and major disturbance sources acting on the spacecraft and test masses are modeled.

Maghami, P. G.↗

High relative humidity increases yield, harvest index, flowering, and gynophore growth of hydroponically grown peanut plants

Growth chamber experiments were conducted to study the physiological and growth response of peanut (Arachis hypogaea L.) to 50% and 85% relative humidity (RH). The objective was to determine the effects of RH on pod and seed yield, harvest index, and flowering of peanut grown by the nutrient film technique (NFT). 'Georgia Red' peanut plants (14 days old) were planted into growth channels (0.15 x 0.15 x 1.2 m). Plants were spaced 25 cm apart with 15 cm between channels. A modified half-Hoagland solution with an additional 2 mM Ca was used. Solution pH was maintained between 6.4 and 6.7, and electrical conductivity (EC) ranged between 1100 and 1200 microS cm-1. Temperature regimes of 28/22 degrees C were maintained during the light/dark periods (12 hours each) with photosynthetic photon flux (PPF) at canopy level of 500 micromoles-m-2s-1. Foliage and pod fresh and dry weights, total seed yield, harvest index (HI), and seed maturity were greater at high than at low RH. Plants grown at 85% RH had greater total and individual leaflet area and stomatal conductance, flowered 3 days earlier and had a greater number of flowers reaching anthesis. Gynophores grew more rapidly at 85% than at 50% RH.

NASA Discipline Life Support Systems↗

Canopy Spectral Invariants: Application to Classification of Forest Types from Hyperspectral Data - Part 2

Many studies have been conducted to demonstrate the ability of hyperspectral data to discriminate plant dominant species. Most of them have employed the use of empirically based techniques, which are site specific, requires some initial training based on characteristics of known leaf and/or canopy spectra and therefore may not be extendable to operational use or adapted to changing or unknown land cover. In this paper we propose a physically based approach for separation of dominant forest type using hyperspectral data. The radiative transfer theory of canopy spectral invariants underlies the approach, which facilitates parameterization of the canopy reflectance in terms of the leaf spectral scattering and two spectrally invariant and structurally varying variables - recollision and directional escape probabilities. The methodology is based on the idea of retrieving spectrally invariant parameters from hyperspectral data first, and then relating their values to structural characteristics of three-dimensional canopy structure. Theoretical and empirical analyses of ground and airborne data acquired by Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) over two sites in New England, USA, suggest that the canopy spectral invariants convey information about canopy structure at both the macro- and micro-scales. The total escape probability (one minus recollision probability) varies as a power function with the exponent related to the number of nested hierarchical levels present in the pixel. Its base is a geometrical mean of the local total escape probabilities and accounts for the cumulative effect of canopy structure over a wide range of scales. The ratio of the directional to the total escape probability becomes independent of the number of hierarchical levels and is a function of the canopy structure at the macro-scale such as tree spatial distribution, crown shape and size, within-crown foliage density and ground cover. These properties allow for the natural separation of dominant forest classes based on the location of points on the total escape probability vs the ratio log-log plane.

Schull, M. A.↗

The Celestial Reference Frame at X/Ka-band (8.4/32 GHz)

A celestial reference frame at X/Kaband (8.4/32 GHz) has been constructed using fiftyone 24-hour sessions with the Deep Space Network. We report on observations which have detected 436 sources covering the full 24 hours of right ascension and declinations down to -45 deg. Comparison of this X/Ka-band frame to the S/X-band (2.3/8.4 GHz) ICRF2 shows wRMS agreement of 200 micro-arcsec ( mu as) in alpha cos delta and 290 mu as in delta. There is evidence for zonal errors at the 100 mu as level. Known errors include limited SNR, lack of phase calibration, troposphere mismodelling, and limited southern geometry. The motivations for extending the ICRF to frequencies above 8 GHz are to access more compact source morphology for improved frame stability, to provide calibrators for phase referencing, and to support spacecraft navigation at Ka-band.

interferometry↗

Measuring rapid ocean tidal earth orientation variations with very long baseline interferometry

Ocean tidal effects on universal time and polar motion (UTPM) are investigated at four nearly diurnal (K(sub 1), P(sub 1), O(sub 1), and Q(sub 1)) and four nearly semidiurnal (K(sub 2), S(sub 2), M(sub 2), and N(sub 2)) frequencies by analyzing very long baseline interferometry (VLBI) data extending from 1978 to 1992. We discuss limitations of comparisons between experiment and theory for the retograde nearly diurnal polar motion components due to their degeneracy with prograde components of the nutation model. Estimating amplitudes of contributions to the modeled VLBI observables at these eight frequencies produces a statistically highly significant improvement of 7 mm to the residuals of a fit to the observed delays. Use of such an improved UTPM model also reduces the 14-30 mm scatter of baseline lengths about a time-linear model of tectonic motion by 3-14 mm, also withhigh significance levels. A total of 28 UTPM ocean tidal amplitudes can be unambiguously estimated from the data, with resulting UTI and PM magnitudes as large as 21 micro secs and 270 microarc seconds and formal uncertainties of the order of 0.3 micro secs and 5 microarc secs for UTI and PM, respectively. Empirically determined UTPM amplitudes and phases are com1pared to values calculated theoretically by Gross from Seiler's global ocean tide model. The discrepancy between theory and experiment is larger by a factor of 3 for UTI amplitudes (9 micro secs) than for prograde PM amplitudes (42 microarc secs). The 14-year VLBI data span strongly attenuates the influence of mismodeled effects on estimated UTPM amplitudes and phases that are not coherent with the eight frequencies of interest. Magnitudes of coherent and quasi-coherent systematic errors are quantified by means of internal consistency tests. We conclude that coherent systematic effects are many times larger than the formal uncertainties and can be as large as 4 micro secs for UTI and 60 microarc secs for polar motion. On the basis of such ealistic error estimates, 22 of the 31 fitted UTPM ocean tidal amplitudes differ from zero by more than 2 sigma.

Sovers, O. J.↗

Terahertz Array Receivers with Integrated Antennas

Highly sensitive terahertz heterodyne receivers have been mostly single-pixel. However, now there is a real need of multi-pixel array receivers at these frequencies driven by the science and instrument requirements. In this paper we explore various receiver font-end and antenna architectures for use in multi-pixel integrated arrays at terahertz frequencies. Development of wafer-level integrated terahertz receiver front-end by using advanced semiconductor fabrication technologies has progressed very well over the past few years. Novel stacking of micro-machined silicon wafers which allows for the 3-dimensional integration of various terahertz receiver components in extremely small packages has made it possible to design multi-pixel heterodyne arrays. One of the critical technologies to achieve fully integrated system is the antenna arrays compatible with the receiver array architecture. In this paper we explore different receiver and antenna architectures for multi-pixel heterodyne and direct detector arrays for various applications such as multi-pixel high resolution spectrometer and imaging radar at terahertz frequencies.

direct detector arrays↗

Environmental and Polarization Characterizations of E-Beam Plasma-Based AlF 3 -Passivated Aluminum Mirrors for Astronomical Telescopes

Astronomical space telescopes to study astrophysical phenomena from the far ultraviolet (FUV) to the near infrared (NIR) will require mirror coatings with high reflectance over this entire spectral region. While coatings for the optical and NIR part of the spectrum are fairly well developed with proven performance, the FUV range has presented significant challenges, particularly below 120nm. Recent developments in electron-beam (e-Beam) generated plasma treatment in a SF 6 environments has enabled the effective passivation of aluminum (Al) coatings for applications in the FUV, by native oxide removal and the formation of a AlF 3 passivation layer which could be tuned to any desired AlF 3 thickness. These results have been produced through a collaboration between the Goddard Space Flight Center (GSFC) and the Naval Research Laboratory (NRL). The passivation experiments have been carried out using the Large Area Plasma Processing System (LAPPS) at NRL using bare aluminum samples and provided by the coating group at GSFC. This novel procedure has demonstrated improved Al mirrors with state-of-the-art FUV reflectivity (e.g. R=91% at 121.6nm). In this paper, we will be reporting on environmental testing, micro-roughness, as well as polarization studies of these E-beam treated samples. These characterizations are being done in order to advance the Technology Readiness Level (TRL) for these Al+AlF 3 mirror coatings produced at LAPPS. The ultimate goal is to demonstrate the promise of using this coating technology to deliver reflectance performance plus stability and uniformity over a large area for a future IR/O/UV space telescope observatory.

FUV reflectance↗

WGM Temperature Tracker

This software implements digital control of a WGM (whispering-gallerymode) resonator temperature based on the dual-mode approach. It comprises one acquisition (dual-channel) and three control modules. The interaction of the proportional-integral loops is designed in the original way, preventing the loops from fighting. The data processing is organized in parallel with the acquisition, which allows the computational overhead time to be suppressed or often completely avoided. WGM resonators potentially provide excellent optical references for metrology, clocks, spectroscopy, and other applications. However, extremely accurate (below micro-Kelvin) temperature stabilization is required. This software allows one specifically advantageous method of such stabilization to be implemented, which is immune to a variety of effects that mask the temperature variation. WGM Temperature Tracker 2.3 (see figure) is a LabVIEW code developed for dual-mode temperature stabilization of WGM resonators. It has allowed for the temperature stabilization at the level of 200 nK with one-second integration time, and 6 nK with 10,000-second integration time, with the above room-temperature set point. This software, in conjunction with the appropriate hardware, can be used as a noncryogenic temperature sensor/ controller with sub-micro-Kelvin sensitivity, which at the time of this reporting considerably outperforms the state of the art.

Strekalov, Dmitry V.↗

Lab-On-a-Chip Application Development (LOCAD): Bridging Technology Readiness for Exploration

At Marshall Space Flight Center we have established a capability to investigate the use of microfluidics for space flight. The Lab-On-a-Chip Application Development (LOCAD) team has created a program for advancing Technology Readiness Levels (TRL) of 1 and 2 to TRL 6 and 7, quickly and economically for Lab-On-a-Chip (LOC) applications. Scientists and engineers can utilize LOCAD'S process to efficiently learn about microfluidics and determine if microfluidics is applicable to their needs. Once the applicability has been determined, LOCAD can then perform tests to develop the new fluidic protocols which are different from macro-scale chemical reaction protocols. With this information new micro-fluidic devices can be created and tested. Currently, LOCAD is focused on using microfluidics for both Environmental Monitoring & Control, and Medical Systems. Eventually, handheld portable units utilizing LOC technology will perform rapid tests to determine water quality, and microbial contamination levels. Since LOC technology is drastically reduced in physical size, it thereby reduces power, weight, volume, and sample requirements, a big advantage considering the resource constraints associated with spaceflight. Another one of LOCAD's current activities is the development of a microfluidic system to aid in the search for life on Mars.

Spearing, Scott F.↗