Search NASA⌕ Search

SEARCH · Search NASA

Results for “microscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Electron Energy-Loss Spectroscopy and Differential Phase Contrast Imaging with Active Decision in Multimodal Electron Microscopy: Isotopic detection at the atomic scale

Isotopic engineering provides a powerful route to control phonon behavior in crystalline solids, enabling fundamental studies of lattice dynamics and heat transport at the atomic scale. Here, we directly visualize isotope-dependent phonon propagation in epitaxial Cr 2 O 3 using aberration-corrected scanning transmission electron microscopy (STEM) combined with monochromated, high-energy-resolution electron energy-loss spectroscopy (EELS). Guided by ab initio phonon calculations, we demonstrate that optical phonon modes above 70 meV are predominantly oxygen-derived and exhibit measurable redshifts upon substitution of natural 16 O by enriched 18 O. Spatially resolved vibrational spectrum imaging reveals isotope-enriched tracer layers within Cr 2 O 3 thin films, correlating isotope concentration with phonon intensity variations and vibrational energy shifts. At the nanometer and atomic scales, vibrational EELS mapping uncovers coherent phonon propagation across isotopic interfaces, consistent with theoretical phonon density of states and dispersion relations. These results establish vibrational EELS as a quantitative probe for isotope-dependent phonon transport in materials, opening new possibilities for studying energy dissipation and lattice dynamics.

36 MATERIALS SCIENCE↗

Understanding Mechanisms of Selective Crystal Nucleation and Growth Using In Situ Electron Microscopy

Separation processes are essential for purifying and isolating critical materials, but are challenging due to the natural tendency of systems to mix. This project explores far-from-equilibrium separation methods using external electric and magnetic fields to drive selective nucleation and crystal growth. Using in situ electrochemical transmission electron microscopy (TEM), we observed ion transport and crystallization behavior under applied electric fields. We found that ions migrate toward the working electrode, where nucleation preferentially occurs. These findings advance our understanding of non-equilibrium separation mechanisms and support the development of efficient, sustainable methods for extracting critical materials from unconventional domestic sources.

36 MATERIALS SCIENCE↗

Automation of Laser Plasma Focused Ion Beam Microscopy for Next-Gen Energy Materials

Automation can revolutionize the use of ultrafast laser ablation and plasma-focused ion beam (PFIB) techniques for high-throughput, reproducible cross-sectioning and various sample preparation in materials characterization. As these methods become essential for analyzing complex energy materials and next-generation devices, efficient, standardized workflows are needed to minimize variability and enhance precision. This work highlights our advancements in developing automated processes for sample preparation that integrates machine learning, workflow optimization, and large-scale data acquisition to improve efficiency and scalability in applications such as electrolyzers, photovoltaic cells, and microelectronics. To streamline cross-sectioning and lamella fabrication, we have implemented fully automated workflows that standardize laser ablation and PFIB milling sequences. These workflows incorporate pre-programmed protocols for material removal, alignment, and thinning, reducing user intervention and ensuring consistency across different sample types. Machine learning algorithms further enhance automation by predicting optimal milling strategies and adapting parameters based on material properties and sectioning requirements. This approach significantly improves throughput while maintaining the structural integrity of prepared samples for high-resolution imaging and analysis, including transmission electron microscopy. Beyond sample preparation, our automation platform enables the acquisition of large, high-resolution datasets through serial sectioning, image alignment, and 3D reconstruction. These automated routines facilitate multi-scale characterization, capturing structural and compositional details from the nanoscale to the device level. By reducing variability and increasing efficiency, our automated approach enhances defect analysis, failure diagnostics, and process optimization, accelerating advancements in materials research and device engineering.

36 MATERIALS SCIENCE↗

Developing affordable and efficient heating devices for enhanced live cell imaging in confocal microscopy

Temperature control is crucial for live cell imaging, particularly in studies involving plant responses to high ambient temperatures and thermal stress. This study presents the design, development, and testing of two cost-effective heating devices tailored for confocal microscopy applications: an aluminum heat plate and a wireless mini-heater. The aluminum heat plate, engineered to integrate seamlessly with the standard 160 mm × 110 mm microscope stage, supports temperatures up to 36°C, suitable for studies in the range of non-stressful warm temperatures (e.g., 25-27°C forArabidopsis thaliana) and moderate heat stress (e.g., 30-36°C forA. thaliana). We also developed a wireless mini-heater that offers rapid, precise heating directly at the sample slide, with a temperature increase rate over 30 times faster than the heat plate. The wireless heater effectively maintained target temperatures up to 50°C, ideal for investigating severe heat stress and heat shock responses in plants. Both devices performed well in controlled studies, including the real-time analysis of heat shock protein accumulation and stress granule formation inA. thaliana. Our designs are effective and affordable, with total construction costs lower than $300. This accessibility makes them particularly valuable for small laboratories with limited funding. Future improvements could include enhanced heat uniformity, humidity control to mitigate evaporation, and more robust thermal management to minimize focus drift during extended imaging sessions. These modifications would further solidify the utility of our heating devices in live cell imaging, offering researchers reliable, budget-friendly tools for exploring plant thermal biology.

Plant Sciences↗

Intrinsic Defect-Induced Local Semiconducting-to-Metallic Regions Within Monolayer 1T-TiS2 Displayed by First-Principles Calculations and Scanning Tunneling Microscopy

Using density functional theory (DFT) and scanning tunneling microscopy (STM), the intrinsic point defects, formation energy, and electronic structure of 1T-TiS2 were investigated. Defect systems include single-atom vacancies, interstitial and adatom additions, and direct atomic substitution. Using a collective approach for analyzing realistic systems for point defect investigation, we provide a more straightforward comparison to the experimental measurements, reproducing more realistic environmental conditions related to thin film growth. STM images are compared to computationally simulated electron density images to identify specific geometries that result from favorable point defects. DFT suggests that titanium interstitials are the most energetically favorable intrinsic defect, and sulfur vacancies are more likely to form than titanium vacancies within this realistic analysis, which is in agreement with STM data. A pristine, stoichiometric monolayer system is calculated to have a direct band gap of 0.422 eV, which varies based on local point defects. Local semiconducting-to-metallic electronic transitions are predicted to occur based on the presence of Ti interstitials.

Keeney, P. J.↗

Effective Polarizability in Near-Field Microscopy of Phonon-Polariton Resonances

We investigate the resonant characteristics of planar surfaces and distinct edges of structures with the excitation of phonon-polaritons. We analyze two materials supporting phonon-polariton excitations in the mid-infrared spectrum: silicon carbide, characterized by an almost isotropic dielectric constant, and hexagonal boron nitride, notable for its pronounced anisotropy in a spectral region exhibiting hyperbolic dispersion. We formulate a theoretical framework that accurately captures the excitations of the structure involving phonon-polaritons, predicts the response in scattering-type near-field optical microscopy, and is effective for complex resonant geometries where the locations of hot spots are uncertain. We account for the tapping motion of the probe, perform analysis for different heights of the probe, and demodulate the signal using a fast Fourier transform. Using this Fourier demodulation analysis, we show that light enhancement across the entire apex is the most accurate characteristic for describing the response of all resonant excitations and hot spots. We demonstrate that computing the demodulation orders of light enhancement in the microscope probe accurately predicts its imaging.

Chemistry↗

Ultra-high Information-content Chemical Imaging with Broadband Coherent Anti-Stokes Raman and Two-photon Fluorescence Lifetime Microscopy

Raman fingerprint spectroscopy and fluorescence lifetime imaging are emerging tools for studying metabolic profiles of biological specimens. While Raman fingerprint spectroscopy detects intrinsic molecular vibrations that reflect the molecular composition and chemical environment of a sample, fluorescence lifetime imaging measures changes in the excited-state lifetime of fluorophores that are sensitive to their microenvironments. Here, we present a multimodal imaging platform combining broadband coherent anti-Stokes Raman scattering (BCARS) and two-photon fluorescence lifetime imaging (2p-FLIM) microscopy that can acquire biologically relevant Raman fingerprint spectra and fluorescence lifetime signals in vivo and simultaneously. The tremendous chemical information obtained from spatially co-registered BCARS and 2p-FLIM images allows us to characterize the subtle differences between sub-cellular compartments and verify the potential false-positive results generated by fluorescence imaging alone. This is demonstrated by directly comparing the BCARS, 2p-FLIM, and two-photon excitation fluorescence(TPEF) signals simultaneously obtained from the same dye-stained organelle in the live, intact C. elegans expressing a green fluorescent protein (GFP) marker. In this work, we introduce the BCARS/2p-FLIM/TPEF setup scheme, the image acquisition steps, data processing, and representative results showing that the cross-modality imaging method enables rigorous characterization and in vivo detection at sub-cellular resolution. Furthermore, this protocol provides a framework for simultaneous chemical and fluorescence lifetime imaging to improve the accuracy of biological interpretation in complex living systems.

Xu, Haoyu [Georgia Institute of Technology, Atlant↗

Transmission electron microscopy of ion irradiated ODS MA956 samples

Oxide dispersion strengthened (ODS) alloys are promising candidate materials for the next generation advanced nuclear reactors due to their superior irradiation resistance and mechanical properties. To better understand the effect of irradiation on MA956, it is essential to study higher dose (50-100 dpa) samples, so that the general trend of microstructural evolution and the resulting radiation-hardening can be deduced. Currently, ion irradiations are considered the only way to achieve doses beyond ~50 dpa in a practical time frame relevant to alloy and welding development programs. This dataset contains TEM characterization results of ODS MA956 samples that were ion irradiated under different conditions: Sample #5 (1.25 dpa at 190℃); Sample #9 (50 dpa at 190℃); Sample #15 (1.25dpa under 320℃); and Sample 17 (25 dpa at 320℃). TEM characterization focused on the irradiation induced defects (dislocation lines and loops) using the on-zone axis bright field STEM technique. These data were collected using a FEI Tecnai G2 F30 S/TEM at Microscopy and Characterization Suite (MaCS) at Center for Advanced Energy Studies (CAES), Idaho Falls, ID. This project (ion irradiation and TEM studies) was supported by the U.S. Department of Energy, Office of Nuclear Energy under DOE Idaho Operations Office Contract DE-AC07-05ID14517 as part of Nuclear Science User Facilities award #18-14784 (PI: Ramprashad Prabhakaran, PNNL).

Prabhakaran, Ramprashad↗

Ghost imaging second harmonic generation microscopy

A system and methods for ghost imaging second harmonic generation microscopy. Imaging data is collected in parallel, providing faster imagine reconstruction and enabling reconstruction in scattering environments. Ghost imaging, split light beam interacting with a target and a second light beam unimpeded and not required to pass through the same background. A second harmonic generation image is reconstructed from the detected photons.

Wiederrecht, Gary P.↗

Learning and Controlling Silicon Dopant Transitions in Graphene Using Scanning Transmission Electron Microscopy

A machine learning approach is introduced to determine the transition dynamics of silicon atoms on a single layer of carbon atoms, when stimulated by the electron beam of a scanning transmission electron microscope (STEM). This method is data-centric, leveraging data collected on a STEM. The data samples are processed and filtered to produce symbolic representations, which is used to train a neural network to predict transition probabilities. These learned transition dynamics are then leveraged to guide a single silicon atom throughout the lattice to pre-determined target destinations. Empirical analyses are presented that demonstrate the efficacy and generality of the approach.

36 MATERIALS SCIENCE↗

Nanoscale Imaging and Measurements of Grain Boundary Thermal Resistance in Ceramics with Scanning Thermal Wave Microscopy

Material thermal conductivity is a key factor in various applications, from thermal management to energy harvesting. With microstructure engineering being a widely used method for customizing material properties, including thermal properties, understanding and controlling the role of extended phonon-scattering defects, like grain boundaries, is crucial for efficient material design. However, systematic studies are still lacking primarily due to limited tools. In this study, we demonstrate an approach for measuring grain boundary thermal resistance by probing the propagation of thermal waves across grain boundaries with a temperature-sensitive scanning probe. The method, implemented with a spatial resolution of about 100 nm on finely grained Nb-substituted SrTiO 3 ceramics, achieves a detectability of about 2 × 10 –8 K m 2 W –1 , suitable for chalcogenide-based thermoelectrics. The measurements indicated that the thermal resistance of the majority of grain boundaries in the STiO 3 ceramics is below this value. While there are challenges in improving sensitivity, considering spatial resolution and the amount of material involved in the detection, the sensitivity of the scanning probe method is comparable to that of optical thermoreflectance techniques, and the method opens up an avenue to characterize thermal resistance at the level of single grain boundaries and domain walls in a spectrum of microstructured materials.

36 MATERIALS SCIENCE↗

Transmission electron microscopy with in-situ ion irradiation: Facilities and community

Whilst there is a clear scientific and technological need for the technical capabilities of transmission electron microscopes with in-situ ion irradiation, it also requires a collaborative community of international researchers to support such facilities in successfully meeting this demand. Instruments of this type serve to provide fundamental understanding of the mechanisms which drive changes in materials important to nuclear fission and fusion energy, the semiconductor industry, quantum information systems, space travel, astronomy, geology and many more applications. As these areas continue to evolve and the instrumentation possibilities expand, the capacity of in-situ ion irradiation facilities must also develop hand-in-hand with the user community to deliver an ever-greater diversity of high-fidelity extreme-environment experimentation. Future directions for the field, such as miniaturization from MEMS/microfluidic devices and advanced controls with ML-based analysis, continuously emerge to advance both the hardware and software which support the coupling of TEMs with ion beams. This review sets out to provide up-to-date insights into the community and advancement of current, and development of future, facilities which have the potential to further unlock access to the nanoscale exploration of coupled extreme environments crucial to many of the important science and engineering challenges we face today.

In-situ irradiation↗

Single-Molecule Fluorescence Microscopy Reveals Energy Transfer Active versus Inactive Nanocrystal/Dye Conjugate Pairs

Defect-mediated energy transfer (EnT) is a radiative process that occurs between donor defect states in the forbidden bandgap of semiconductor nanocrystals (NCs) and dye molecules bound to their surfaces. The EnT efficiency depends on the number of dye molecules attached to each NC, the donor–acceptor distance, and the dipole orientation factor between the donor and acceptor, all of which vary across all individual NCs in a sample. While ensemble-level fluorescence spectroscopy measurements have provided average values for donor–acceptor distances, dye-to-NC ratios, and EnT rate constants, questions remain about the impact of donor/acceptor heterogeneity on observed EnT efficiencies. Notably, ensemble-level measurements cannot distinguish between bare NCs and EnT-active versus inactive NC/dye pairs in the same sample batch, limiting the ability to design systems with 100% EnT efficiency. To address this, we studied defect-mediated EnT between AlexaFluor 555 dye acceptors chemically bound to ZnO NC donors at the level of single molecules and single NCs. Interestingly, 20% of bound NC/dye pairs are EnT-inactive, likely contributing to residual defect photoluminescence (PL) observed in ensemble-level measurements and reducing overall EnT efficiency. Single particle-level ZnO defect PL and acceptor fluorescence trajectories exhibited distinct microfluctuations, which are absent in bare ZnO NCs. We hypothesized that our observations can be explained with a competitive dye fluorescence quenching pathway, possibly due to charge transfer between the excited state dye and the ZnO NC. Numerical simulations of single-molecule PL traces for this scenario produced microfluctuations consistent with the experimental results. These findings highlight the impact of sample heterogeneity on EnT processes and provide insights for designing light-harvesting systems with optimized EnT efficiency.

25 ENERGY STORAGE↗