At least 253 records · Page 14

Miniature implantable ultrasonic echosonometer

A miniature echosonometer adapted for implantation in the interior of an animal for imaging the internal structure of a organ, tissue or vessel is presented. The echosonometer includes a receiver/transmitter circuit which is coupled to an ultrasonic transducer. Power is coupled to the echosonometer by electromagnetic induction through the animal's skin. Imaging signals from the echosonometer are electromagnetically transmitted through the animal's skin to an external readout apparatus.

Kojima, G. K.↗

Miniature interferometer terminals for earth surveying

A system of miniature radio interferometer terminals was proposed for the measurement of vector baselines with uncertainties ranging from the millimeter to the centimeter level for baseline lengths ranging, respectively, from a few to a few hundred kilometers. Each terminal would have no moving parts, could be packaged in a volume of less than 0.1 cu m, and would operate unattended. These units would receive radio signals from low-power (10 w) transmitters on earth-orbiting satellites. The baselines between units could be determined virtually instantaneously and monitored continuously as long as at least four satellites were visible simultaneously.

Counselman, C. C., III↗

Miniature flow-direction and airspeed sensor for airplanes and radio controlled models in spin studies

A miniature flow direction and airspeed sensor was developed for use on 1/10- to 1/15 scale models and on full-scale airplanes engaged in spin research. The range of flow angles encountered in spinning flight (+ or - 120 degrees in angle of attack and + or - 55 degrees in sideslip) is larger than that of normal flight. These angles, along with an effective airspeed range of 9 to 90 m/sec, were measured with static accuracies of + or - 0.35 degrees for angle of attack, + or - 0.25 degrees for sideslip angle, and + or - 1 m/sec for airspeed. The dynamic accuracy is adequate to measure the rapidly changing flow angles and airspeed without singificant distortion. The sensor is rugged enough to withstand both the airplane environment and that of the radio-controlled, unpowered models.

Kershner, D. D.↗

Miniature cyclotron resonance ion source using small permanent magnet

An ion source using the cyclotron resonance principle is described. A miniaturized ion source device is used in an air gap of a small permanent magnet with a substantially uniform field in the air gap of about 0.5 inch. The device and permanent magnet are placed in an enclosure which is maintained at a high vacuum (typically 10 to the minus 7th power) into which a sample gas can be introduced. The ion beam end of the device is placed very close to an aperture through which an ion beam can exit into the apparatus for an experiment.

Anicich, V. G.↗

Miniature drag-force anemometer

A miniature drag force anemometer is described which is capable of measuring unsteady as well as steady state velocity head and flow direction. It consists of a cantilevered beam with strain gages located at the base of the beam as the force measuring element. The dynamics of the beam are like those of lightly damped second order system with a natural frequency as high as 40 kilohertz depending on beam geometry and material. The anemometer is used in both forward and reversed flow. Anemometer characteristics and several designs are presented along with discussions of several applications.

Krause, L. N.↗

Personal miniature electrophysiological tape recorder

The use of a personal miniature electrophysiological tape recorder to measure the physiological reactions of space flight personnel to space flight stress and weightlessness is described. The Oxford Instruments Medilog recorder, a battery-powered, four-channel cassette tape recorder with 24 hour endurance is carried on the person and will record EKG, EOG, EEG, and timing and event markers. The data will give information about heart rate and morphology changes, and document adaptation to zero gravity on the part of subjects who, unlike highly trained astronauts, are more representative of the normal population than were the subjects of previous space flight studies.

Green, H.↗

Miniature drag-force anemometer

A miniature drag-force anemometer is described which is capable of measuring unsteady as well as steady-state velocity head and flow direction. It consists of a cantilevered beam with strain gages located at the base of the beam as the force measuring element. The dynamics of the beam are like those of a lightly damped second-order system with a natural frequency as high as 40 kilohertz depending on beam geometry and material. The anemometer can be used in both forward and reversed flow. Anemometer characteristics and several designs are presented along with discussions of several applications.

Krause, L. N.↗

Miniature Temperature-Control Circuit

Operates on any power supply voltage from 6 to 28 volts. Miniature thermostate circuit controls electric heating element to maintain constant temperature in oven or other thermal environment.

Couch, R. H.↗

Miniature Airflow Sensor

Miniature flow-angle and airspeed sensor quickly mounted on light aircraft wing with two-sided tape since conventional sensors are restricted to large aircraft. Sensor operates as free-trailing wind vane selfalineing in airstream through two independent axes. Vane attached to wing surface through hollow mounting boom that fits on mounting plate attached to wing with two-sided neoprene-foam tape. Method shown strong enough for loads of low-speed flight.

Kershner, D. D.↗

Miniature spectrally selective dosimeter

A miniature spectrally selective dosimeter capable of measuring selected bandwidths of radiation exposure on small mobile areas is described. This is achieved by the combination of photovoltaic detectors, electrochemical integrators (E-cells) and filters in a small compact case which can be easily attached in close proximity to and substantially parallel to the surface being measured. In one embodiment two photovoltaic detectors, two E-cells, and three filters are packaged in a small case with attaching means consisting of a safety pin. In another embodiment, two detectors, one E-cell, three filters are packaged in a small case with attaching means consisting of a clip to clip over a side piece of an eye glass frame.

Adams, R. R.↗

A miniature, directional surface-fence gage for three-dimensional turbulent boundary layer measurements

A new miniature (3.175 mm overall diameter) surface-fence gage was developed to measure simultaneously the magnitude and direction of wall shear stress under three-dimensional turbulent boundary layers. Two fence elements were placed orthogonal to each other on the end surface of the gage. The gage was calibrated for its directional and magnitude sensitivities. It was then tested under an axisymmetric swirling boundary layer, subject to a sudden transverse strain. The advantage of the gage was demonstrated, and excellent agreement was obtained with the results from surface oil flow interferometry and velocity field measurements. The results also compared well with numerical computations.

Higuchi, H.↗

A miniature tilting pad gas lubricated bearing

This paper describes the design and development of a miniature tilting pad gas bearing developed for use in very small turbomachines. The bearings have been developed for cryogenic turboexpanders with shaft diameters down to about 0.3 cm and rotational speeds up to one million rpm. Cryogenic expansion turbines incorporating this type of bearing should be suitable for refrigeration rates down to about 10 w.

Sixsmith, H.↗

Preliminary concept of a 100-kilowatt miniaturized Cassegrainian concentrator solar array

A miniaturized Cassegrainian concentrator (MCC) solar array system is examined to assess the practicality of assembling the basic MCC element into a total array system capable of producing multi-hundred kilowatts of power for Space Platform/Space Station or other low Earth orbit long lifetime missions. Preliminary mechanical and electrical subsystems are developed in order to determine first order performance characteristics. Results of the study support the feasibility of a 100-kilowatt MCC array system with beginning-of-life (BOL) performance of 160 watts per square meter and 28 W/kg. The performance numbers are based on 20 percent efficient (at operating temperature) solar cells and 0.25-millimeter thick electroformed nickel optics. These performance numbers can be improved upon significantly with the development of higher efficiency solar cells and/or lighter weight optics.

Patterson, R. E.↗

Development of a miniature scanning electron microscope for in-flight analysis of comet dust

A description is presented of an instrument which was developed with the original goal of being flown on the International Comet Mission, scheduled for a 1985 launch. The Scanning Electron Microscope and Particle Analyzer (SEMPA) electron miniprobe is a miniaturized electrostatically focused electron microscope and energy dispersive X-ray analyzer for in-flight analysis of comet dust particles. It was designed to be flown on board a comet rendezvous spacecraft. Other potential applications are related to asteroid rendezvous and planetary lander missions. According to the development objectives, SEMPA miniprobe is to have the capability for imaging and elemental analysis of particles in the size range of 0.25 microns and larger.

Conley, J. M.↗

A miniature tactical Rb frequency standard

Work on an innovative design for miniature rubidium frequency standards has reached the pre-production demonstration stage at Litton Guidance and Control Systems. Pre-production units were built and tested under contract to the Rome Air Development Center of the U.S. Air Force Systems Command. The units, which are designed for use in tactical military applications, feature fast warm-up, low power consumption, and vibration insensitivity. The output stability under vibration is maintained without the need for external shock-mounts. The design objectives and test results are discussed.

Kwon, T. M.↗

An experimental study for a miniature Stirling refrigerator

Experimental results of a miniature two-stage Stirling cryocooler are introduced. The influence of filling gas pressure and refrigeration temperature on the refrigerating capacity along with the relationship between parameters was measured. The valley pressure corresponding to the lowest refrigeration temperature and the cooldown time versus operating pressure are discussed. The coefficient of performance and thermodynamic efficiency of the cryocooler are calculated based on experimental data.

Li, S.↗

Design, performance investigation and delivery of a miniaturized Cassegrainian concentrator solar array

A miniaturized Cassegrainian concentrator (MCC) solar array concept is being developed with the objective of significantly reducing the recurring cost of multikilowatt solar arrays. The desired cost reduction is obtained as a result of using very small high efficiency solar cells in conjunction with low-cost optics. In the MCC single element concept and panel concept, incident solar radiation is reflected from a primary parabolic reflector to a secondary hyperbolic reflector and finally to a 4-millimetr diameter solar cell. A light catcher cone is used to improve off-axis performance. An element is approximately 13-millimeters thick which permits efficient launch stowage of the concentrator system panels without complex optical component deployments or retractions. The MCC elements are packed in bays within graphite epoxy frames and are electrically connected into appropriate series-parallel circuits. A MCC single element with a 21 sq cm entrance aperture and a 20 percent efficient, 0.25 sq cm gallium arsenide solar cell has the same power output as 30-sq cm of 11-percent efficiency (at 68 C) silicon solar cells. The MCC concept provides the potential for a significant reduction in array cost due to a 99 percent reduction in required cell area and a 30 percent reduction in array area relative to planar array of equivalent power.

Patterson, R. E.↗

A miniature remote deadweight calibrator

A miniature, computer-controlled, deadweight calibrator was developed to remotely calibrate a force transducer mounted in a cryogenic chamber. This simple mechanism allows automatic loading and unloading of deadweights placed onto a skin friction balance during calibrations. Equipment for the calibrator includes a specially designed set of five interlocking 200-milligram weights, a motorized lifting platform, and a controller box taking commands from a microcomputer on an IEEE interface. The computer is also used to record and reduce the calibration data and control other calibration parameters. The full-scale load for this device is 1,000 milligrams; however, the concept can be extended to accommodate other calibration ranges.

Supplee, Frank H., Jr.↗