Search NASA⌕ Search

SEARCH · Search NASA

Results for “multilayers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

One-dimensional numerical analysis of the transient thermal response of multilayer insulative systems

A one-dimensional numerical analysis of the transient thermal response of multilayer insulative systems has been developed. The analysis can determine the temperature distribution through a system consisting of from one to four layers, one of which can be an air gap. Concentrated heat sinks at any interface can be included. The computer program based on the analysis will determine the thickness of a specified layer that will satisfy a temperature limit criterion at any point in the insulative system. The program will also automatically calculate the thickness at several points on a vehicle and determine total system mass.

Pittman, C. M.↗

Purging of multilayer insulation by gas diffusion

An experimental investigation was conducted to determine the time required to purge a multilayer insulation (MLI) panel with gaseous helium by means of gas diffusion to obtain a condensable (nitrogen) gas concentration of less than 1 percent within the panel. Two flat, rectangular MLI panel configurations, one incorporating a butt joint, were tested. The insulation panels consisted of 15 double-aluminized Mylar radiation shields separated by double silk net spacers. The test results indicated that the rate which the condensable gas concentration at the edge or at the butt joint of an MLI panel was reduced was a significant factor in the total time required to reduce the condensable gas concentration within the panel to less than 1 percent. The experimental data agreed well with analytical predictions made by using a simple, one-dimensional gas diffusion model in which the boundary conditions at the edge of the MLI panel were time dependent.

Sumner, I. E.↗

Prevention of thermal bending of multilayered beams and plates

By adding an extra layer to multilayer beams or plates of different isotropic materials, it is possible to prevent the thermal bending of these materials. With the proper selection of thermoelastic properties the curvature produced prior to this addition would be eliminated. Several numerical examples are presented for various temperature distributions. A simple experiment was conducted, involving the addition of a brass strip to a bimetallic strip made of aluminum and steel at room temperature. The trimetal strip was placed in a furnace and remained straight for varying temperatures.

Yang, J. C. S.↗

Purging of a multilayer insulation with dacron tuft spacer by gas diffusion

The time and purge gas usage required to purge a multilayer insulation (MLI) panel with gaseous helium by means of gas diffusion to obtain a condensable gas (nitrogen) concentration of less than 1 percent within the panel are stipulated. Two different, flat, rectangular MLI panels, one incorporating a butt joint, were constructed of of 11 double-aluminized Mylar (DAM) radiation shields separated by Dacron tuft spacers. The DAM/Dacron tuft concept is known commercially as Superfloc. The nitrogen gas concentration as a function of time within the MLI panel could be adequately predicted by using a simple, one dimensional gas diffusion model in which the boundary conditions at the edge of the MLI panel were time dependent. The time and purge gas usage required to achieve 1 percent nitrogen gas concentration within the MLI panel varied from 208 to 86 minutes and 34.1 to 56.5 MLI panel purge volumes, respectively, for gaseous helium purge rates from 10 to 40 MLI panel volumes per hour.

Sumner, I. E.↗

Purging of a tank-mounted multilayer insulation system by gas diffusion

The investigation was conducted on a multilayer insulation (MLI) system mounted on a spherical liquid hydrogen propellant tank. The MLI consisted of two blankets of insulation each containing 15 double-aluminized Mylar radiation shields separated by double silk net spacers. The gaseous nitrogen initially contained within the MLI system and vacuum chamber was purged with gaseous helium introduced both underneath the MLI and into the vacuum chamber. The MLI panels were assumed to be purged primarily by means of gas diffusion. Overall, test results indicated that nitrogen concentrations well below 1 percent could be achieved everywhere within the MLI system. Typical times to achieve 1 percent nitrogen concentration within the MLI panels ranged from 69 minutes at the top of the tank to 158 minutes at the bottom of the tank. Four space-hold thermal performance tests indicated no significant thermal degradation of the MLI system had occurred due to the purge tests conducted. The final measured heat input attributed to the MLI was 7.23 watts as compared to 7.18 watts for the initial baseline thermal performance test.

Sumner, I. E.↗

Users' instructions for the NASA/MSFC cloud-rise preprocessor program, version 6, and the NASA/MSFC multilayer diffusion program, version 6: Research version for Univac 1108 system

The cloud-rise preprocessor and multilayer diffusion computer programs were used by NASA in predicting concentrations and dosages downwind from normal and abnormal launches of rocket vehicles. These programs incorporated: (1) the latest data for the heat content and chemistry of rocket exhaust clouds; (2) provision for the automated calculation of surface water pH due to deposition of HCl from precipitation scavenging; (3) provision for automated calculation of concentration and dosage parameters at any level within the vertical grounds for which meteorological inputs have been specified; and (4) provision for execution of multiple cases of meteorological data. Procedures used to automatically calculate wind direction shear in a layer were updated.

Bjorklund, J. R.↗

Thermal performance of gaseous-helium-purged tank-mounted multilayer insulation system during ground-hold and space-hold thermal cycling and exposure to water vapor

An experimental investigation was conducted to determine (1) the ground-hold and space-hold thermal performance of a multilayer insulation (MLI) system mounted on a spherical, liquid-hydrogen propellant tank and (2) the degradation to the space-hold thermal performance of the insulation system that resulted from both thermal cycling and exposure to moisture. The propellant tank had a diameter of 1.39 meters (4.57ft). The MLI consisted of two blankets of insulation; each blanket contained 15 double-aluminized Mylar radiation shields separated by double silk net spacers. Nineteen tests simulating basic cryogenic spacecraft thermal (environmental) conditions were conducted. These tests typically included initial helium purge, liquid-hydrogen fill and ground-hold, ascent, space-hold, and repressurization. No significant degradation of the space-hold thermal performance due to thermal cycling was noted.

Sumner, I. E.↗

Evaluation of a hybrid, anisotropic, multilayered, quadrilateral finite element

A multilayered finite element with bending-extensional coupling is evaluated for: (1) buckling of general laminated plates; (2) thermal stresses of laminated plates cured at elevated temperatures; (3) displacements of a bimetallic beam; and (4) displacement and stresses of a single-cell box beam with warped cover panels. Also, displacements and stresses for flat and spherical orthotropic and anisotropic segments are compared with results from higher order plate and shell finite-element analyses.

Robinson, J. C.↗

A simple element for multilayer beams in NASTRAN thermal stress analysis

In the application of NASTRAN, structural members are usually represented by bar elements with multipoint constraint cards to enforce the interface conditions. While this is a very powerful method in principle, it was found that in practice the process for specification of constraints became tedious and error prone, unless the geometry was simple and the number of grid points low. An alternative approach was found within the framework of the NASTRAN program. This approach made use of the idea that a thermal distortion in a multilayer beam may be similar to a homogeneous beam with a thermal gradient across the cross section. The exact mathematical derivation for the equivalent beam, and all the necessary formulae for the equivalent parameters in NASTRAN analysis are presented. Some numerical examples illustrate the simplicity and ease of this approach for finite element analysis.

Chen, W. T.↗

Wave tilt sounding of multilayered structures

The relationship between the wave tilt and the electrical parameters of a multilayered structure is investigated. Particular emphasis is placed on the inverse problem associated with the sounding planetary surfaces. An inversion technique, based on multifrequency wave tilt, is proposed and demonstrated with several computer models. It is determined that there is close agreement between the electrical parameters used in the models and those in the inversion values.

Warne, L.↗

A current access, self-structured, multilayered bubble domain memory

Preliminary experimental results are reported on a self-structured, multilayer bubble memory with buried data layer. Stripe domains are used to move carrier bubbles by magnetostatic coupling. An expression is derived for that coupling as a function of thickness of the GGG separation layer. Experimental values of coupling are given as a function of bias field. An expression for stripe curvature as a function of bias field is derived. The performance of seven different current access stripe propagation circuits is reported.

Stermer, R. L., Jr.↗

Study of noise reduction characteristics of multilayered panels and dual pane windows with Helmholtz resonators

The experimental noise attenuation characteristics of flat, general aviation type, multilayered panels are discussed. Experimental results of stiffened panels, damping tape, honeycomb materials and sound absorption materials are presented. Single degree of freedom theoretical models were developed for sandwich type panels with both shear resistant and non-shear resistant core material. The concept of Helmholtz resonators used in conjunction with dual panel windows in increasing the noise reduction around a small range of frequency was tested. It is concluded that the stiffening of the panels either by stiffeners or by sandwich construction increases the low frequency noise reduction.

Navaneethan, R.↗

Accelerated life testing and reliability of high K multilayer ceramic capacitors

The reliability of one lot of high K multilayer ceramic capacitors was evaluated using accelerated life testing. The degradation in insulation resistance was characterized as a function of voltage and temperature. The times to failure at a voltage-temperature stress conformed to a lognormal distribution with a standard deviation approximately 0.5.

Minford, W. J.↗

Evacuation-induced pressure differentials in multilayer insulation systems

The pressure differentials induced across three types of multilayer insulation systems during evacuation have been measured and compared with values predicted using an idealized parallel plate geometric model. The systems tested were double-aluminized Mylar with a Tissuglas or silk net spacer and crinkled single-aluminized Mylar. Test samples were circular. The influence of purge gas type, layer density, sample diameter, and temperature was systematically investigated. The experimental approach was to measure the absolute pressure history and corresponding pressure differential induced across the insulation during evacuation. The measured pressure differentials were nondimensionalized and compared with those predicted by the parallel plate model as a function of Knudsen number. It was concluded that the parallel plate model is adequate for making engineering analyses. The influence of all parameters, except layer density, is well represented by the model. Representation of the influence of layer density is less satisfactory, but can be improved by modification of the flat plate model to allow for the more obvious practical nonidealities, such as crinkling, or the presence of a net spacer.

Glassford, A. P. M.↗

A multilayer model of time dependent deformation following an earthquake on a strike-slip fault

A multilayer model of the Earth to calculate finite element of time dependent deformation and stress following an earthquake on a strike slip fault is discussed. The model involves shear properties of an elastic upper lithosphere, a standard viscoelastic linear solid lower lithosphere, a Maxwell viscoelastic asthenosphere and an elastic mesosphere. Systematic variations of fault and layer depths and comparisons with simpler elastic lithosphere over viscoelastic asthenosphere calculations are analyzed. Both the creep of the lower lithosphere and astenosphere contribute to the postseismic deformation. The magnitude of the deformation is enhanced by a short distance between the bottom of the fault (slip zone) and the top of the creep region but is less sensitive to the thickness of the creeping layer. Postseismic restressing is increased as the lower lithosphere becomes more viscoelastic, but the tendency for the width of the restressed zone to growth with time is retarded.

Cohen, S. C.↗

Improved multilayer insulation applications

Multilayer insulation blankets used for the attenuation of radiant heat transfer in spacecraft are addressed. Typically, blanket effectiveness is degraded by heat leaks in the joints between adjacent blankets and by heat leaks caused by the blanket fastener system. An approach to blanket design based upon modular sub-blankets with distributed seams and upon an associated fastener system that practically eliminates the through-the-blanket conductive path is described. Test results are discussed providing confirmation of the approach. The specific case of the thermal control system for the optical assembly of the Space Telescope is examined.

Mikk, G.↗

Investigation of multilayer magnetic domain lattice file

A theoretical and experimental investigation determined that current accessed self structured bubble memory devices have the potential of meeting projected data density and speed requirements. Device concepts analyzed include multilayer ferrimagnetic devices where the top layer contains a domain structure which defines the data location and the second contains the data. Current aperture and permalloy assisted current propagation devices were evaluated. Based on the result of this work more detailed device research was initiated. Detailed theoretical and experimental studies indicate that the difference in strip and threshold between a single bubble in the control layer and a double bubble which would exist in both the control layer and data layer is adequate to allow for detection of data. Detailed detector designs were investigated.

Torok, E. J.↗

Thermomechanical loading of multilayered cylindrical geometries in thermal cycling from 300 to 1300 K

The principal of multiple material layering is well known as an effective method of reducing heat transfer; however, thermal gradients can impose significant loads and lead to delamination and subsequent component failure. An analysis is developed and experimental data are discussed for the thermomechanical effects of multilayered materials on a heat sink substrate of cylindrical geometry subject to thermal cycling. The geometry is heated in cross-flow by a high-velocity flame and cooled in crossflow by ambient-temperature air from a critical flow orifice. Each layer of material possesses a threshold beyond which small changes in temperature or mechanical loading greatly influence the life in thermal cycling of the layered materials. Comparisons are made between the thermomechanical loads predicted by various numerical codes for the linear case and by a simplified analytic model.

Hendricks, R. C.↗