Search NASA⌕ Search

SEARCH · Search NASA

Results for “nanosecond pulse”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

FLASH-therapy suitable single-pulse proton generation using TiH 2 under nanosecond laser irradiation

We investigated proton emission from titanium hydride (TiH 2 ) targets irradiated in vacuum by a 6-ns, 1064-nm Nd:YAG laser. Time-of-flight measurements with a Faraday cup and an electrostatic ion analyzer resolved distinct proton peaks at high pulse energies, with yields on the order of 10 9 protons per shot. Systematic scans over pulse energy and up to 1000 repeated shots showed that, while the peak amplitude gradually decreased, the integrated proton number remained nearly constant. This behavior is consistent with surface-induced broadening of the plasma expansion while bulk hydrogen is replenished by diffusion and repeated ablation of fresh TiH 2 layers. Using the measured proton numbers and pulse widths, a simple direct-plasma-injection-style scaling indicates peak currents of ∼100 mA and sub-microsecond pulse durations. The pulse structure and yield satisfy key ultra-high-dose-rate criteria and, together with sustained output over 1000 shots, support TiH 2 -based laser ion sources as practical candidates for FLASH-therapy (ultra-high-dose-rate)-oriented studies and injector development using direct plasma injection.

43 PARTICLE ACCELERATORS↗

Nanosecond Transient Validation of Surge Arrester Models to Predict Electromagnetic Pulse Response

The impact of high-altitude electromagnetic pulse events on the electric grid is not fully understood, and validated modeling of mitigations, such as lightning surge arresters (LSAs) is necessary to predict the propagation of very fast transients on the grid. Experimental validation of high frequency models for surge arresters is an active area of research. Further, this article serves to experimentally validate a previously defined ZnO LSA model using four metal-oxide varistor pucks and nanosecond scale pulses to measure voltage and current responses. The SPICE circuit models of the pucks showed good predictability when compared to the measured arrester response when accounting for a testbed inductance of approximately 100 nH. Additionally, the comparatively high capacitance of low-profile arresters show a favorable response to high-speed transients that indicates the potential for effective electromagnetic pulse mitigation with future materials design.

42 ENGINEERING↗

Dopant Optimization of Donors in Semiconductor Opening Switches to Eliminate Prepulse

Semiconductor opening switches are solid-state devices capable of delivering nanosecond, hundreds of kilovolts pulses by interrupting kiloamps of current. The interruption of the current occurs in a moderately doped p-region when a high electric field region (HFR) is formed. The HFR occurs because the reverse pumping current cannot be supported by the saturation velocity and majority carrier concentration of the doping level. However, the donor profile also significantly affects the pulse performance. A secondary prepulse occurs if a secondary HFR is formed at the interface of the background n-doping and N+ doping (X n ) . By moving the location of X n deeper into the diode, the effect of the prepulse is reduced. This article investigates the effect of the donor doping profile on the performance metrics of semiconductor opening switches through technology computer-aided design (TCAD) simulations and experimental results. Through a SILVACO TCAD optimization, we designed a P + /p/n - base/n/N + where the intersection of the moderate p-region and intrinsic n-base region (X p ) is at 160 μm and X n is at 220 μm. This profile is fabricated via silicon epitaxy. Experimentally, it is shown that a deep X n (220 μm) compared with a shallow X n (300 μm) reduces the rise time by >5× . In addition, the magnitude of current density during interruption affects the prepulse foot and pulse shape. At lower current densities without the graded donor profile, high peak voltages are not achieved. Comparing the experimental results to the TCAD simulations shows that the model is predictive under high-current densities in the semiconductor opening switch (SOS) regime.

nanosecond pulse power↗

Response of silicon solar cell to pulsed laser illumination

The response of silicon solar cell(s) to pulsed laser illumination is discussed. The motivation was due to the interest of Earth to space/Moon power beaming applications. When this work began, it was not known if solar cells would respond to laser light with pulse lengths in the nanosecond range and a repetition frequency in the kHz range. This is because the laser pulse would be shorter than the minority carrier lifetime of silicon. A 20-nanosecond (ns) full width half max (FWHM) pulse from an aluminum-gallium/arsenide (Al-Ga-As) diode laser was used to illuminate silicon solar cells at a wavelength of 885 nanometers (nm). Using a high-speed digital oscilloscope, the response of the solar cells to individual pulses across various resistive loads was observed and recorded.

Willowby, D.↗

Towards a Counting Point Detector for Nanosecond Coherent X-ray Science

We present the technical realization of a high-speed hard X-ray single-photon counting-detection scheme based on a commercial avalanche silicon photodiode and high-speed oscilloscope. The development is motivated by the need to perform pulse-resolved photon-correlation and pump-probe studies at synchrotron sources with densely packed pulse patterns that result in high repetition rate pulses on the order of hundreds of MHz. Commissioning experiments are performed at the 1C PAL-KRISS beamline at PLS-II of South Korea operating at a burst mode maximum repetition rate of 500 MHz. In such a high count-rate measurement, detector dead-time can lead to a distortion of counting statistics. We are able to model the counting behavior of our detector under these conditions with a detector dead-time comparable to time between X-ray pulses, implying that nanosecond X-ray photon correlation spectroscopy should be possible at diffraction-limited light sources.

36 MATERIALS SCIENCE↗

Demonstration of sub-GV/m accelerating field in a photoemission electron gun powered by nanosecond 𝑋-band radio-frequency pulses

Radio-frequency (rf) photoemission electron guns operating at higher accelerating gradients offer a pathway to produce brighter electron bunches. Brighter beams are expected to revolutionize many areas of science: they could form the backbone of next-generation compact x-ray free-electron lasers or provide coherent ultrafast quantum electron probes. We report on the experimental demonstration of an rf photoemission electron source supporting an accelerating field close to 400 MV/m at the photocathode surface without major rf breakdown or significant dark current over a 3-week experimental run. This unprecedented gradient was achieved by operating the gun in a new regime with short rf pulses, ~9ns X-band (11.7 GHz). The demonstrated paradigm provides a viable path to form relativistic electron beams with unprecedented brightness.

43 PARTICLE ACCELERATORS↗

Plasma assisted NH 3 /H 2 /air ignition in nanosecond discharges with non-equilibrium energy transfer

Ammonia (NH 3 ), with its high energy density and easiness to store and transport as a hydrogen carrier, has become a promising alternative green fuel. However, its adoption in power generation is hindered by challenges such as low burning velocity, slow low-temperature oxidation, high NO x emissions, and ignition difficulty. Here, this work computationally investigates the effects of non-equilibrium energy transfer by nanosecond discharges on NH 3 ignition and flame propagation in an NH 3 /H 2 /air flow at 700 K and 1 atm. The simulation results demonstrate that NH 3 /air mixtures require a large ignition energy due to their large critical ignition radius. It is shown that adding 30 % hydrogen significantly reduces the critical ignition radius and minimum ignition energy. Two-dimensional modeling further shows a non-monotonic dependence of ignition kernel volume on the applied voltage and reduced electric field. The optimum ignition enhancement occurs at 200 Td where the generation of electronically excited species and radicals including N 2 (B), O( 1 D) and OH becomes most efficient. Higher voltages divert electron energy toward ionization, which makes it less effective for NH 3 ignition. The study also identifies an optimal electrode gap size for a given pulse energy. Smaller gap sizes increase deposited energy density, raising temperature and radical concentrations. However, excessive reduction of the gap distance reduces flame propagation speed due to the flame stretch effect in rich mixtures with the effective Lewis number greater than unity. A nonlinear relationship between pulse repetition frequency and ignition kernel volume is observed in a nanosecond pulsed high frequency discharge (NPHFD). An optimal frequency range of 200 kHz to 2 MHz is found when two pulses are used. In addition, an optimal number of pulses exists for each pulse repetition frequency, with higher frequencies requiring more pulses to maximize the overlap region. These findings provide critical insights on developing controlled plasma discharge techniques for efficient NH 3 ignition in reactive flows within internal combustion engines and gas turbines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pulse-length dependence of the laser-induced damage behavior of a fused-silica antireflective metasurface

A broadband, antireflective metasurface optic on a silica substrate is subjected to laser-induced damage-threshold measurements to quantify its performance under exposure to high-intensity/fluence laser pulses in the near-infrared at four pulse durations, ranging from 20 fs to 1.4 ns. The performance of the metasurface is benchmarked against that obtained from an equivalent bare fused-silica substrate that did not receive reactive-ion-etching metasurface treatment. Results showed that the damage threshold of the antireflective metasurface was always lower than the input-surface damage threshold of the untreated substrate. The damage initiations with nanosecond and picosecond pulses resulted in localized modification and removal of the nanostructures, whereas the onset of laser-induced modification with 20-fs pulses in a vacuum environment manifested as changes in the optical and electronic properties without significant material removal. The broader goal of this work is to develop a preliminary understanding of the laser-induced failure mechanisms of silica-based metasurface optics.

antireflection↗

Single-shot, double-pulse determination of the detonation energy in nanosecond-laser ablation using the blast model

We demonstrate a novel single-shot method to determine the detonation energy of laser-induced plasma and investigate its performance. This approach can be used in cases where there are significant shot-to-shot variations in ablation conditions, such as laser fluctuations, target inhomogeneity, or multiple filamentation with ultrashort pulses. The Sedov blast model is used to fit two time-delayed shadowgrams measured with a double-pulse laser. We find that the reconstruction of detonation parameters is insensitive to the choice of interpulse delay in double-pulse shadowgraphy. In contrast, the initial assumption of expansion dimensionality has a large impact on the reconstructed detonation energy. The method allows for a reduction in the uncertainties of blast wave energy measurements as a diagnostic technique employed in various laser ablation applications.

42 ENGINEERING↗

Intense cavitation-assisted electric discharge as a promising tool for water treatment

This study investigates interrelations between one-electrode Cavitation-Assisted Electric Discharge (CAED), two-electrode CAED, and recently discovered Intense CAED (I-CAED). The one-electrode CAED is a self-triggered nanosecond discharge with pulse energy in the micro-Joule range, which can be generated even by a DC voltage. I-CAED consists of a non-equilibrium part within a low-pressure cavitating region and a micro-spark traversing a liquid film. We hypothesize that CAED propagates from the high-voltage electrode as an ionization wave through bubbles of saturated vapor. Subsequently, the streamer-like discharges in the bubbles may form a continuous plasma channel. Inside the cavitating region, the plasma is strongly non-equilibrium, providing an ideal environment for generating chemically unstable species such as hydrogen peroxide (H 2 O 2 ). Plasma of I-CAED spark is characterized by high electron density and near-thermal equilibrium, emitting a continuous ultraviolet spectrum. The combination of these different discharge parts makes I-CAED in water a highly effective tool for the Advanced Oxidation Process, particularly in water disinfection. Experimentally demonstrated Electric Energy per Order value for disinfection of E. coli-contaminated water is as low as 0.135 ± 0.035 kWh/m 3 /order. Estimates show that the implementation of “dry electrodes” configuration reduces the erosion rate of the electrode material by at least one order of magnitude. Spectral analysis reveals that the continuum emission generated by I-CAED in proximity to metal electrodes deviates from the spectra of discharges spatially decoupled from the electrodes. We assume that this spectral divergence is attributable to blackbody-like emission originating from metallic nanoparticles form during the electrode's erosion process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dye laser traveling wave amplifier

A flash lamp pumped dye laser suitable for use as an amplifier stage was developed. The desired output laser pulses are of nanosecond duration, tunable in center frequency, and of good optical quality. Its usefulness as a laser oscillator is emphasized, because it constitutes a compact, relatively efficient source of tunable dye laser light.

Davidson, F.↗

Measurement of temperature and density fluctuations in turbulence using an ultraviolet laser

Noninvasive measurement of density and temperature fluctuations in turbulent air flow was examined. The approach used fluorescence of oxygen molecules which are selectively excited by a tunable vacuum ultraviolet laser beam. The strength of the fluorescence signal and its dependence on laser wavelength vary with the density and temperature of the air in the laser beam. Because fluorescence can be detected at 90 degrees from the beam propagation direction, spatial resolution in three dimensions, rather than path-integrated measurements can be achieved. With spatial resolutions of the order of a millimeter and at supersonic air velocities it is necessary to perform each measurement in a time of the order of a microsecond; this is possible by by using laser pulses of ten nanosecond duration. In this method atmospheric O2 is excited by the emission of a tunable ArF excimer laser, and the fluorescence, which spans the 210 to 420 range, is detected by an ultraviolet phototube.

Massey, G. A.↗

Exploration of Options for Ultra-Fast Mass Spectroscopy for Pulsed Power Applications

Mega-ampere class pulsed power machines drive intense currents into small volumes to study high energy and density environments. Power lost during these events is a difficult and paramount problem to solve. For example, facilities such as Sandia National Laboratories’ Z machine experience meaningful power loss, which can be linked to non-linear ohmic heating at high currents (i.e., 26 MA on Z) leading to thermal desorption of contaminants and subsequent shunt plasma formation. Characterizing and understanding this type of thermal desorption is key to design optimizations necessary to minimize current loss, which will be even more important for next generation pulsed power. This type of characterization requires the ability to identify and determine concentration of analytes with nanosecond resolution given the pulse width of Z is on the order of 100 ns. This report summarizes progress on a small exploratory project focused on investigating options to meet this challenge using mass spectrometry. The main focus of these efforts utilized an Energy and Velocity Analyzer for Distributions of Electric Rockets intending to determine how quickly transient data could be resolved. This probe combines an electrostatic analyzer with a Wien velocity filter (ExB) to obtain ion energy and velocity distributions. Primary results from this exploratory project indicate significant additional work is needed to demonstrate a nanosecond time scale mass spectrometer for this application and also highlight that alternative detection methods such as laser-based diagnostics should be considered to meet the need for ultra-fast detection.

42 ENGINEERING↗

Laser damage of HR, AR-coatings, monolayers and bare surfaces at 1064 nm

Laser induced damage thresholds and morphologies were investigated in a variety of uncoated and coated surfaces, including monolayers and multi-layers of different chemical compositions. Both antireflective (AR) and highly reflective (HR) were tested. Testing was done at 1064 nm with 25 picosecond and 8 nanosecond YAG/Nd laser single pulses. Spot diameter in the experiments varied from 0.09 to 0.22 mm. The laser damage measurement procedure consisted of 1-on-1 (single laser pulse in the selected site) and N-on-1 experiments including repeated irradiation by pulses of the same fluence and subsequently raised from pulse to pulse fluence until damage occurred. The highest picosecond damage thresholds of commercially available coatings averaged 12 - 14 J/sq cm, 50 percent less than thresholds obtained in bare fused silica. Some coatings and bare surfaces revealed a palpable preconditioning effect (an increase in threshold of 1.2 to 1.8 times). Picosecond and nanosecond data were compared to draw conclusions about pulse width dependence. An attempt was made to classify damage morphologies according to the type of coating, class of irradiating, and damage level.

Garnov, S. V.↗

Exploration of Defect Dynamics and Color Center Qubit Synthesis with Pulsed Ion Beams

Short-pulse ion beams have been developed in recent years and now enable applications in materials science. A tunable flux of selected ions delivered in pulses of a few nanoseconds can affect the balance of defect formation and dynamic annealing in materials. We report results from color center formation in silicon with pulses of 900 keV protons. G-centers in silicon are near-infrared photon emitters with emerging applications as single-photon sources and for spin-photon qubit integration. G-centers consist of a pair of substitutional carbon atoms and one silicon interstitial atom and are often formed by carbon ion implantation and thermal annealing. Here, we report on G-center formation with proton pulses in silicon samples that already contained carbon, without carbon ion implantation or thermal annealing. The number of G-centers formed per proton increased when we increased the pulse intensity from 6.9 × 10 9 to 7.9 × 10 10 protons/cm 2 /pulse, demonstrating a flux effect on G-center formation efficiency. We observe a G-center ensemble linewidth of 0.1 nm (full width half maximum), narrower than previously reported. Pulsed ion beams can extend the parameter range available for fundamental studies of radiation-induced defects and the formation of color centers for spin-photon qubit applications.

43 PARTICLE ACCELERATORS↗

Digital Time-Resolved Spot Diagnostic

The digital time-resolved spot diagnostic (D-TRSD) is intended to be a fast-response, time-dependent beam diagnostic for measuring the spot size emitted from radiographic x-ray sources. It will measure spot sizes from submillimeters up to several millimeters for photon energies in the range of 150 keV to 20 MeV with doses as low as 0.03 rad up to 500 rad. The D-TRSD performs fast data acquisition as radiographic x-ray sources typically produce pulses in the tens of nanosecond ranges. The system will be optimized to capture multiple individual pulses in time within the same data record. The data collected will be used to support beam tuning and source optimization with on-the-fly evaluation of radiographic source performance. The diagnostic is based on penumbral imaging techniques. A scintillating fiber array of parallel aligned fibers is positioned in the beam path with a high-Z rolled edge inserted between the source and the array, thereby creating the penumbral x-ray signal that is captured by the D-TRSD system. The light from the scintillation conversion is recorded by individual avalanche photodiode detectors integrated into custom digitizer electronics. The penumbra is used to calculate the spot of the beam on the axis orthogonal to the fiber array based on the magnification from the rolled edge, the resolution of the spaced fibers, and the rotation of the array normal to the beam path. Many arrays can be used to capture additional spot widths about different rotations. The D-TRSD system is modular, software-driven, and easier to use than legacy TRSD systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Preliminary Design of a New Pulsed-Neutron Die--Away Experiments with Absorbers (IER-552 CED-1)

This report presents the preliminary design (CED-1) of IER-552, pulsed-neutron die-away (PNDA) experiments with absorbers, to be conducted by Lawrence Livermore National Laboratory (LLNL). The goal of the PNDA experiments with absorbing materials is to produce high-quality, low-cost integral benchmarks that can be used to validate cross sections that are high priority nuclear data for the Department of Energy’s Nuclear Criticality Safety Program (NCSP). PNDA experiments can be used to generate nuclear data validation benchmarks quickly and cheaply, as they do not require fissile material or a nuclear facility to conduct them. The original PNDA experiments were set up at LLNL under IER-501. Extending the PNDA experiments to include absorbing materials leverages existing facilities and resources at LLNL to validate cross sections, with a basic experiment design that uses a neutron generator to impinge a short, mono-energetic neutron pulse on a poisoned, moderating target sample. The neutron pulse lasts 100 µs, after which the neutron population in the sample reaches thermal equilibrium and later spatial equilibrium. In this fully equilibrized state, the neutron population has a characteristic decay-time eigenvalue. The eigenvalue can be used as an integral parameter to validate nuclear data involved with neutron scattering and absorption. Two observables can be measured: the neutron population and the population of secondary γ-rays produced by inelastic and capture reactions. This report explores the feasibility of both approaches. For γ-ray measurements, this allows for direct measurement of reactions of interest for validation. During the neutron burst time, inelastic (prompt) γ-rays dominate, and these data can be isolated for validation of neutron inelastic scattering data. After the pulse ends, neutron capture (delayed) γ-rays dominate and are produced by many reaction channels as neutrons slow down to thermal energies. Two sets of γ-ray spectra (inelastic, capture) can be produced for validation. Additionally, the time-dependent decay of the capture γ-ray population when the neutron population is thermalized and in its fundamental mode can be used for validation. Two experiments can be imagined where pulsed neutrons are used to validate the nuclear data of absorbing materials. The first integrates well into the existing PNDA testbed at LLNL. The absorber material would be introduced into a moderating target and the same neutron generator, neutron detectors, electronics, and shielding box used for IER-501 would be employed. From the same experimental setup, many absorbing materials can be validated by simply changing the neutron poison in the moderator. The only significant modification would be the introduction of a γ-ray detector. Such an experiment would primarily serve to validate nuclear data in the thermal energy range. The second kind of experiment would validate the fast and epithermal energy range. It would involve pulsing neutron into a bare assembly of the absorber material and measuring the die-away of neutrons. The fast leakage of such an assembly requires nanosecond neutron-generator pulse widths and fast detectors/electronics that could measure ~200 ns die-away curves. This kind of experiment would ideally be performed at a cyclotron, like that available at Lawrence Berkeley National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radar altimetry over sea ice

To study the sea-ice interactive region in the Bering and Greenland Seas a series of experimental compaigns, the Marginal Ice Zone Experiment (MIZEX) has been planned. A major objective of MIZEX is the development of a capability to relate the morphology and distribution of the sea ice to atmospheric and oceanographic parameters in an overall model. During the first part of the MIZEX, a 13.7 GHz microwave radar altimeter/scatterometer having a pulse length of 16 nanoseconds was flown over the Bering Sea Marginal ice zone. On the same aircraft were the NASA GSFC 19 GHz Electronically Scanning Microwave Radiometer (ESMR), scanning radiometers and an infrared, nadir pointing, temperature sounder. The altimeter/scatterometer was operated in nadir pointing and conically scanning modes to collect measurements of reflectivity and pulse shapes. These will be related to sea-ice classifications, ocean wave spectra and coincident microwave and infrared radiometric measurements and laser profilometer surface roughness estimates.

Powell, J.↗