Search NASA⌕ Search

SEARCH · Search NASA

Results for “navigation accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Pathfinder - Accuracy improvement of comet Halley trajectory for Giotto navigation

The 'Pathfinder' project uses the resources of NASA, ESA and Intercosmos to support the Giotto space probe flyby of comet Halley. The required 500-km approach to comet Halley on the sunward side was so uncertain as to preclude the trajectory's realization with sufficient accuracy on the basis of ground-based astronomical observations alone. Spaceborne observations by the two Vega satellites were accordingly conducted; these, in combination with a very accurate determination of the Vega trajectories using VLBI, allowed a flyby distance of 600 km to be achieved with only + or - 40 km uncertainty.

Muench, R. E.↗

Autonomous navigation using lunar beacons

The concept of using lunar beacon signal transmission for on-board navigation for earth satellites and near-earth spacecraft is described. The system would require powerful transmitters on the earth-side of the moon's surface and black box receivers with antennae and microprocessors placed on board spacecraft for autonomous navigation. Spacecraft navigation requires three position and three velocity elements to establish location coordinates. Two beacons could be soft-landed on the lunar surface at the limits of allowable separation and each would transmit a wide-beam signal with cones reaching GEO heights and be strong enough to be received by small antennae in near-earth orbit. The black box processor would perform on-board computation with one-way Doppler/range data and dynamical models. Alternatively, GEO satellites such as the GPS or TDRSS spacecraft can be used with interferometric techniques to provide decimeter-level accuracy for aircraft navigation.

Khatib, A. R.↗

Integrated Precision Landing Performance and Technology Assessments of a Human-Scale Mars Lander Using a Generalized Simulation Framework

Human-scale missions to Mars will likely require multiple landers delivered precisely to designated locations. The current NASA human Mars reference architecture assumes delivery of three 25 t payloads from a 1- or 5-Sol orbit to the surface with a landing precision of 50 m to ensure logistics are located near the habitat. While initial navigation estimates improve with on-orbit ground tracking, errors increase during post-deorbit coast. Likewise, Mars atmospheric variability and forecasting uncertainty means that the entry vehicle guidance, navigation, and control systems must be robust to accommodate landing during any time of day or Mars year, including during dust storms. Precision landing technologies are currently being assessed to determine if onboard navigation sensors are sufficient to enable the landing accuracy required or if additional navigation aids such as surface or orbiting beacons will be needed. This study evaluates the system performance requirements to meet the desired landing accuracy for the reference vehicle design and entry, descent, and landing concept of operations. A detailed six degree-of-freedom integrated performance simulation framework is used to perform the assessment and demonstrate that under current assumptions, onboard navigation sensors are sufficient to support precision landing.

spacecraft navigation↗

Integrated Precision Landing Performance and Technology Assessments of a Human- Scale Mars Lander Using a Generalized Simulation Framework

Human-scale missions to Mars will likely require multiple landers delivered precisely to designated locations. The current NASA human Mars reference architecture assumes delivery of three 25 t payloads from a 1- or 5-Sol orbit to the surface with a landing precision of 50 m to ensure logistics are located near the habitat. While initial navigation estimates improve with on-orbit ground tracking, errors increase during post-deorbit coast. Likewise, Mars atmospheric variability and forecasting uncertainty means that the entry vehicle guidance, navigation, and control systems must be robust to accommodate landing during any time of day or Mars year, including during dust storms. Precision landing technologies are currently being assessed to determine if onboard navigation sensors are sufficient to enable the landing accuracy required or if additional navigation aids such as surface or orbiting beacons will be needed. This study evaluates the system performance requirements to meet the desired landing accuracy for the reference vehicle design and entry, descent, and landing concept of operations. A detailed six degree-of-freedom integrated performance simulation framework is used to perform the assessment and demonstrate that under current assumptions, onboard navigation sensors are sufficient to support precision landing.

Chen, Po-Ting↗

SU-E-T-154: Establishment and Implement of 3D Image Guided Brachytherapy Planning System

Purpose: Cannot observe the dose intuitionally is a limitation of the existing 2D pre-implantation dose planning. Meanwhile, a navigation module is essential to improve the accuracy and efficiency of the implantation. Hence a 3D Image Guided Brachytherapy Planning System conducting dose planning and intra-operative navigation based on 3D multi-organs reconstruction is developed. Methods: Multi-organs including the tumor are reconstructed in one sweep of all the segmented images using the multiorgans reconstruction method. The reconstructed organs group establishs a three-dimensional visualized operative environment. The 3D dose maps of the three-dimentional conformal localized dose planning are calculated with Monte Carlo method while the corresponding isodose lines and isodose surfaces are displayed in a stereo view. The real-time intra-operative navigation is based on an electromagnetic tracking system (ETS) and the fusion between MRI and ultrasound images. Applying Least Square Method, the coordinate registration between 3D models and patient is realized by the ETS which is calibrated by a laser tracker. The system is validated by working on eight patients with prostate cancer. The navigation has passed the precision measurement in the laboratory. Results: The traditional marching cubes (MC) method reconstructs one organ at one time and assembles them together. Compared to MC, presented multi-organs reconstruction method has superiorities in reserving the integrality and connectivity of reconstructed organs. The 3D conformal localized dose planning, realizing the 'exfoliation display' of different isodose surfaces, helps make sure the dose distribution has encompassed the nidus and avoid the injury of healthy tissues. During the navigation, surgeons could observe the coordinate of instruments real-timely employing the ETS. After the calibration, accuracy error of the needle position is less than 2.5mm according to the experiments. Conclusion: The speed and quality of 3D reconstruction, the efficiency in dose planning and accuracy in navigation all can be improved simultaneously.

60 APPLIED LIFE SCIENCES↗

Deep-space navigation applications of improved ground-based optical astrometry

Improvements in ground-based optical astrometry will eventually be required for navigation of interplanetary spacecraft when these spacecraft communicate at optical wavelengths. Although such spacecraft may be some years off, preliminary versions of the astrometric technology can also be used to obtain navigational improvements for the Galileo and Cassini missions. This article describes a technology-development and observational program to accomplish this, including a cooperative effort with U.S. Naval Observatory Flagstaff Station. For Galileo, Earth-based astrometry of Jupiter's Galilean satellites may improve their ephemeris accuracy by a factor of 3 to 6. This would reduce the requirements for onboard optical navigation pictures, so that more of the data transmission capability (currently limited by high-gain antenna deployment problems) can be used for science data. Also, observations of European Space Agency (ESA) Hipparcos stars with asteroid 243 Ida may provide significantly improved navigation accuracy for a planned August 1993 Galileo spacecraft encounter.

Null, G. W.↗

Enhanced character sizes for the VDM-1 video display board

Use of a microprocessor for providing navigation information from the inherent hyperbolic geometries of Loran-C was discussed. The advantages Loran-C offers over VOR/DME as a primary navigation aid are identified. These advantages include long range coverage by several stations, coverage at low altitudes, and the capability to have nonprecision approaches at airports not already served by landing aids. Modern digital electronic technology is used to produce a device to convert Loran-C data to useful pilot information using simple software algorithms and low cost microprocessor devices. The cost and lack of availability of suitable processors to execute these algorithms have prevented a Loran-C navigator from being developed. Results indicate that the microprocessor based Loran-C navigator has an accuracy of 1.0 nm or less over an area typically covered by a triad of Loran-C stations and can execute a position update in less than 0.2 seconds.

Novacki, S. M., III↗

A Multi-Function Guidance, Navigation and Control System for Future Earth and Space Missions

Over the past several years the Guidance, Navigation and Control Center (GNCC) at NASA's Goddard Space Flight Center (GSFC) has actively engaged in the development of advanced GN&C technology to enable future Earth and Space science missions. The Multi-Function GN&C System (MFGS) design presented in this paper represents the successful coalescence of several discrete GNCC hardware and software technology innovations into one single highly integrated, compact, low power and low cost unit that simultaneously provides autonomous real time on-board attitude determination solutions and navigation solutions with accuracies that satisfy many future GSFC mission requirements. The MFGS is intended to operate as a single self-contained multifunction unit combining the functions now typically performed by a number of hardware units on a spacecraft. However, recognizing the need to satisfy a variety of future mission requirements, design provisions have been included to permit the unit to interface with a number of external remotely mounted sensors and actuators such as magnetometers, sun sensors, star cameras, reaction wheels and thrusters. The result is a highly versatile MFGS that can be configured in multiple ways to suit a realm of mission-specific GN&C requirements. It is envisioned that the MFGS will perform a mission enabling role by filling the microsat GN&C technology gap. In addition, GSFC believes that the MFGS could be employed to significantly reduce volume, power and mass requirements on conventional satellites.

Gambino, Joel↗

Covariance Analysis Tool (G-CAT) for Computing Ascent, Descent, and Landing Errors

G-CAT is a covariance analysis tool that enables fast and accurate computation of error ellipses for descent, landing, ascent, and rendezvous scenarios, and quantifies knowledge error contributions needed for error budgeting purposes. Because GCAT supports hardware/system trade studies in spacecraft and mission design, it is useful in both early and late mission/ proposal phases where Monte Carlo simulation capability is not mature, Monte Carlo simulation takes too long to run, and/or there is a need to perform multiple parametric system design trades that would require an unwieldy number of Monte Carlo runs. G-CAT is formulated as a variable-order square-root linearized Kalman filter (LKF), typically using over 120 filter states. An important property of G-CAT is that it is based on a 6-DOF (degrees of freedom) formulation that completely captures the combined effects of both attitude and translation errors on the propagated trajectories. This ensures its accuracy for guidance, navigation, and control (GN&C) analysis. G-CAT provides the desired fast turnaround analysis needed for error budgeting in support of mission concept formulations, design trade studies, and proposal development efforts. The main usefulness of a covariance analysis tool such as G-CAT is its ability to calculate the performance envelope directly from a single run. This is in sharp contrast to running thousands of simulations to obtain similar information using Monte Carlo methods. It does this by propagating the "statistics" of the overall design, rather than simulating individual trajectories. G-CAT supports applications to lunar, planetary, and small body missions. It characterizes onboard knowledge propagation errors associated with inertial measurement unit (IMU) errors (gyro and accelerometer), gravity errors/dispersions (spherical harmonics, masscons), and radar errors (multiple altimeter beams, multiple Doppler velocimeter beams). G-CAT is a standalone MATLAB- based tool intended to run on any engineer's desktop computer.

Boussalis, Dhemetrios↗

Camera Calibration and Alignment Metrology at Johnson Space Center’s Electro-Optics Laboratory

It is increasingly common to see spacecraft equipped with cameras for the purpose of navigation. Images are either sent to Earth or processed autonomously on-board to provide information about the vehicle’s position, velocity, and/or attitude. These can be images of stars or celestial bodies for absolute navigation, or images of another spacecraft for relative navigation. While monocular cameras do not provide range information, the images they capture can be processed to determine bearing vectors to target objects within the camera’s field of view. For a camera to be effective in navigation, it must be carefully calibrated and aligned. This involves accurately modeling the optical effects that govern the projection of line-of-sight directions onto the camera’s pixels and determining the camera’s orientation relative to the spacecraft’s reference frame. Engineers at Johnson Space Center’s Electro-Optics Lab regularly perform camera inspection, calibration, and alignment metrology. This was done for the Orion Optical Navigation (OpNav) Camera, the Orion Docking Camera (DCAM), and for numerous cameras belonging to commercial partners. The nature of optical navigation means that cameras must be well-calibrated and their attitude well understood to provide high accuracy bearing measurements to the navigation filter. The stringent accuracy requirements for Orion could not have been met using traditional checkerboard camera calibration or by simply relying on design drawings. This paper details the hardware, software, techniques, and algorithms used by the EOL team to achieve this level of accuracy.

Paul D Mckee↗

Camera Calibration and Alignment Metrology at Johnson Space Center’s Electro-Optics Laboratory

It is increasingly common to see spacecraft equipped with cameras for the purpose of navigation. Images are either sent to Earth or processed autonomously on-board to provide information about the vehicle’s position, velocity, and/or attitude. These can be images of stars or celestial bodies for absolute navigation, or images of another spacecraft for relative navigation. While monocular cameras do not provide range information, the images they capture can be processed to determine bearing vectors to target objects within the camera’s field of view. For a camera to be effective in navigation, it must be carefully calibrated and aligned. This involves accurately modeling the optical effects that govern the projection of line-of-sight directions onto the camera’s pixels and determining the camera’s orientation relative to the spacecraft’s reference frame. Engineers at Johnson Space Center’s Electro-Optics Lab regularly perform camera inspection, calibration, and alignment metrology. This was done for the Orion Optical Navigation (OpNav) Camera, the Orion Docking Camera (DCAM), and for numerous cameras belonging to commercial partners. The nature of optical navigation means that cameras must be well-calibrated and their attitude well understood to provide high accuracy bearing measurements to the navigation filter. The stringent accuracy requirements for Orion could not have been met using traditional checkerboard camera calibration or by simply relying on design drawings. This paper details the hardware, software, techniques, and algorithms used by the EOL team to achieve this level of accuracy.

Paul McKee↗

Flight evaluation of differential GPS aided inertial navigation systems

Algorithms are described for integration of Differential Global Positioning System (DGPS) data with Inertial Navigation System (INS) data to provide an integrated DGPS/INS navigation system. The objective is to establish the benefits that can be achieved through various levels of integration of DGPS with INS for precision navigation. An eight state Kalman filter integration was implemented in real-time on a twin turbo-prop transport aircraft to evaluate system performance during terminal approach and landing operations. A fully integrated DGPS/INS system is also presented which models accelerometer and rate-gyro measurement errors plus position, velocity, and attitude errors. The fully integrated system was implemented off-line using range-domain (seventeen-state) and position domain (fifteen-state) Kalman filters. Both filter integration approaches were evaluated using data collected during the flight test. Flight-test data consisted of measurements from a 5 channel Precision Code GPS receiver, a strap-down Inertial Navigation Unit (INU), and GPS satellite differential range corrections from a ground reference station. The aircraft was laser tracked to determine its true position. Results indicate that there is no significant improvement in positioning accuracy with the higher levels of DGPS/INS integration. All three systems provided high-frequency (e.g., 20 Hz) estimates of position and velocity. The fully integrated system provided estimates of inertial sensor errors which may be used to improve INS navigation accuracy should GPS become unavailable, and improved estimates of acceleration, attitude, and body rates which can be used for guidance and control. Precision Code DGPS/INS positioning accuracy (root-mean-square) was 1.0 m cross-track and 3.0 m vertical. (This AGARDograph was sponsored by the Guidance and Control Panel.)

Mcnally, B. David↗

Relative Navigation Algorithms for Phase 1 of the MMS Formation

This paper evaluates several navigation approaches for the first phase of the Magnetospheric Multiscale (MMS) mission, which consists of a tetrahedral formation of four satellites in highly eccentric Earth orbits of approximately 1.2 by 12 Earth radii at an inclination of 10 degrees. The inter-satellite separation is approximately 10 kilometers near apogees. Navigation approaches were studied using ground station m g e =d two-way Doppler measurements, Global Positioning System (GPS) pseudorange measurements, crosslink range measurements among the members flying in formation, and various combinations of these measurement types. An absolute position accuracy of 10 kilometers or better can be achieved with most of the approaches studied and a relative position accuracy of 100 meters or better can be achieved at apogee in some cases. Among the various approaches studied, the approaches that use a combination of GPS and crosslink measurements were found to be more reliable in terms of absolute and relative navigation accuracies and operational flexibility.

Kelbel, David↗

Impact of tether cutting on onboard navigation during the Tethered Satellite Mission-1

The first Tethered Satellite System mission (TSS-1) is manifested for Shuttle Flight STS-44 in January of 1991. The TSS mission presents a new challenge to engineers, requiring advanced guidance, navigation and control concepts. Current NASA flight rules require that the navigational state of the Orbiter at deorbit burn be known to an accuracy of 20 nautical miles. Response of the Shuttle crew to this contingency may involve cutting the tether prior to a complete retrieval. The degradation of the navigational state accuracy as modelled by Shuttle navigation system is examined. Responses to the loss of communication scenario are proposed for two cases. The first case examines navigational performance during a nominal attitude profile. The second case is identical to the first, with the inclusion of modelled tether electrodynamical forces. Comparisons of trajectories propagated from the onboard navigational state vector and a reference ephemeris state vector were performed, with the tether cut simulated at various points during the mission. Additionally, updates to the onboard navigational state via ground uplinks were provided prior to the assumed loss of communication. Through these comparisons, the onboard navigation state error was determined. Alternative responses result from efforts to minimize this error during the various phases of TSS-1 deployment. These results demonstrated existing NASA flight rules could be violated by cutting the tether, and suggests reponses to a loss of communications contingency to maintain a more accurate navigational state.

Pirker, Dana M.↗

Mapping of sea ice and measurement of its drift using aircraft synthetic aperture radar images

Side-looking radar images of Arctic sea ice were obtained as part of the Arctic Ice Dynamics Joint Experiment. Repetitive coverages of a test site in the Arctic were used to measure sea ice drift, employing single images and blocks of overlapping radar image strips; the images were used in conjunction with data from the aircraft inertial navigation and altimeter. Also, independently measured, accurate positions of a number of ground control points were available. Initial tests of the method were carried out with repeated coverages of a land area on the Alaska coast (Prudhoe). Absolute accuracies achieved were essentially limited by the accuracy of the inertial navigation data. Errors of drift measurements were found to be about + or - 2.5 km. Relative accuracy is higher; its limits are set by the radar image geometry and the definition of identical features in sequential images. The drift of adjacent ice features with respect to one another could be determined with errors of less than + or - 0.2 km.

Leberl, F.↗

Furthering Precision in Sentinel Node Navigational Surgery for Oral Cancer: a Novel Triple Targeting System

To describe an innovative sentinel lymph node (SLN) guidance approach using a radionuclide tracer, 3D augmented reality-guided imaging, and near infrared (NIR) fluorescence over-lay imaging with hand-held probes to optimize accuracy, efficiency, and precise navigation for sentinel node (SN) localization in head and neck cancer. In a cT1N0M0 squamous cell carcinoma of the tongue, pre-operative radionuclide lymphoscintigraphy was performed with a sentinel node-specific radiolabeled tracer. Intraoperatively, a 3D hand-held augmented reality (AR) scanning SPECT probe assessed concordance of the SN with pre-operative SPECT-CT images. The real-time optical video was linked to the SPECT-CT images for added precision. Final guidance to the SN was performed using ICG fluorescence imaging. Dynamic and SPECT-CT showed bilateral lymphatic drainage from the tumor. The 3D hand-held AR SPECT probe SN localization was concordant with pre-operative imaging. The optical video successfully demonstrated the lymphatic drainage in real-time through a unique overlay fluorescence image. The ICG localized to the same nodes identified by both the SPECT-CT and hand-held SPECT images. The use of dual radiation and fluorescence tracers improved SN detection, especially for SN close to the injection site. The hand-held probes allowed the surgeon to dissect continuously, without needing to change tools. The combination of augmented reality, nuclear medicine, and over-lay fluorescence imaging allowed greater accuracy for matching the preoperative imaging with intraoperative identification and precisely guiding the dissection. This method uniquely permitted the surgeon to efficiently dissect the SN with accurate visualization and optimal precision.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Near Rectilinear Halo Orbit Determination with Simulated DSN Observations

This paper presents the results of a high-fidelity simulation of spacecraft orbit determination in a near rectilinear halo orbit (NRHO). Others in the literature have examined this problem with linear covariance analysis, but the highly-nonlinear dynamics of this orbit challenge the assumptions underlying such analyses. The present work builds on similar analysis performed by other authors to contribute a fuller understanding of the operational requirements for NRHO navigation. The present work serves as a check to the assumptions of previous studies and an independent verification of those results. The results from the literature are extended by quantifying the space of orbital states from which a spacecraft with given control authority can safely return to the nominal path. Spacecraft state uncertainty estimates are evaluated as a function of time. Simulated range and range-rate measurements with the Deep Space Network (DSN) ground stations are used to model orbit determination accuracy. Orbit maintenance maneuvers are performed using both short-horizon and long-horizon stationkeeping targeting. Monte Carlo analysis of orbit determination and stationkeeping is performed. This paper quantifies the achievable state uncertainty with deep space network (DSN)-only range and range-rate observations. This paper also addresses requirements on the frequency of DSN observation periods and correlates ground contact frequency with navigation accuracy. The results of several related studies are presented and discussed: the effect of missing ground station passes, the effect of missing stationkeeping maneuvers, the sensitivity of the spacecraft state estimate to realistic error sources, and stationkeeping propellant budget.

Nathan L Parrish↗