Search NASA⌕ Search

SEARCH · Search NASA

Results for “neutron techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

The measurement of trace elements in interplanetary dust and cometary particles by ultra-high sensitivity INAA

Today the major elemental composition of interplanetary dust particles (IDPs) is routinely determined in many laboratories. These and mineralogical studies have revealed the presence of at least two major types of IDPs, chondritic and refractory. Preliminary results of a successful attempt to determine abundances of a large suite of trace elements from both chondritic and refractory IDPs are reported. The analytical procedure can be used in the grain-by-grain analysis of returned cometary samples. Chondritic and refractory IDPs are characterized by standard scanning electron microscopy and energy dispersive x ray spectroscopy (SEM-EDX) techniques. With this system, detection limits for many elements are well below picogram levels, and some approach femtogram levels. This technique is non-destructive, although some sample handling is required, so particles can be analyzed by other techniques after instrument neutron activation analysis (INAA) is completed. Data is presently being reduced from the analyses of 7 IDPs. These are U2015E10, U2015F1, W7029-A2, W7029-A3, W7013A8, LACl (all chondritic) and 705 (refractory). So far, 17 different major and trace elements were detected and measured in these particles, including rare earths and some very volatile elements (Br and Zn).

Zolensky, M. E.↗

Nonequilibrium magnons studied by inelastic neutron scattering

In this work, we explore time-resolved dynamics of non-equilibrium magnons in Rb2MnF4, a model two-dimensional square lattice Heisenberg antiferromagnet using a novel laser-neutron pump-probe technique. This technique uses a nanosecond pulsed laser to periodically excite magnons to out-of-equilibrium states and then probe the resulting dynamics using INS.

36 MATERIALS SCIENCE↗

Real-time neutron multiplicity and source localization for criticality safety during fuel debris removal

Advancing neutron detection and analysis techniques for complex radiation environments is an ongoing focus in nuclear instrumentation and monitoring. This proposal presents research and development of a generalized real-time neutron monitoring and analysis system, applicable to any detector capable of producing time-tagged neutron count data. While the work is demonstrated using the Neutron Multiplication Analysis Detector (NoMAD), a modular 15-tube helium-3 (He-3) array, due to its availability, spatial resolution, and flexible deployment, the methods developed are extensible to other systems, including organic scintillators and fast digital detectors. This research investigates two complementary analytical techniques for real-time characterization of neutron emitting sources: neutron multiplicity estimation based on the Hage-Cifarelli formalism and spatial localization using supervised machine learning applied to spatial count rate patterns. These methods are designed to operate under dynamic, evolving conditions such as fuel debris retrieval or reactor startup, where neutron-emitting material geometries may be partially unknown or changing over time. By integrating statistical neutron emission data with spatial localization, this research aims to develop and evaluate methods for real time neutron monitoring, source characterization, and material verification. Key contributions include implementation of a low-latency data pipeline for continuous neutron multiplicity analysis, development and validation of machine learning models for spatial inference, and experimental evaluation of system performance under variable measurement conditions. The outcomes are intended to support applications in nuclear safeguards, verification, emergency response, and reactor startup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical Studies of the On-Line Reactivity Monitoring Techniques in Subcritical Systems: Revisit of the Area-Ratio Method, the Neutron Source-Modulation Method, and the Flux-to-Current Ratio Method

In the subcritical systems, the subcriticality level must be monitored continuously to ensure the safe operation of the systems. Techniques such as the neutron source-modulation method and the flux-to-current ratio method have been proposed for on-line reactivity measurements of the subcritical systems. However, the accuracy of these methods is unknown in the actual applications. In this report, the fundamental concepts of these techniques are visited, with numerical simulation techniques developed to validate these on-line reactivity monitoring methodologies. Specifically, the Monte Carlo numerical simulation results show that the neutron source-modulation method is not accurate in determining the reactivity of the subcritical systems. The flux-to-current ratio method can provide on-line reactivity measurements, and its spatial effects have been studied and well understood through the numerical simulations of the fuel loading of the neutron source facility of Ukraine. In addition, a modified version of the area-ratio method is proposed for the on-line measurements of the absolute reactivity of the subcritical systems. Monte Carlo numerical simulations showed that this method can provide the absolute reactivity of the subcritical systems within ~5% error, if the neutron detectors are placed close to the fuel assembly interface with the reflector zone or in the reflector zones away from the neutron source.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of Organic Electron Materials using Neutron Scattering (Final Report)

Neutron scattering is a powerful suite of measurement techniques that enable unique analysis of structure and dynamics of a wide variety of materials. Specifically, neutrons interact strongly with protons, which enables excellent contrast in light element organic materials that cannot be obtained with any other measurements. This series of three proposals focused on using inelastic neutron scattering (INS) to study the vibrations (dynamics) of the organic molecules involved in organic electronic devices. Our main goals were to demonstrate that INS is capable of elucidating new, useful, and unique knowledge about organic electronic samples that could be used to improve the function of devices or to solve outstanding problems that could not be solved using other measurement techniques. Since all of the goal involved using INS or other neutron techniques to do something “new” a large part of the effort was focused on complex data interpretation and development of modeling workflows that could be used by other members of the organic electronics community to study their materials. To facilitate the goal of making INS measurements more accessible to a broader community and for a wider range of materials, we optimized and engineered the computational workflows to be well documented, publicly available, and user friendly. The individual titles of the three sequential DOE-BES awards are: (1) Engineering doping profiles in organic semiconducting materials, (2) Measurement and modeling of molecular dopant structure and dynamics, and (3) Quantification of Dynamic Disorder in Electronic and Excitonic Organic Materials. For readability, this report is organized to highlight the progress of the research thematically. Many of the ideas started in one grant period and then spilled over into later awards and collaborative research.

36 MATERIALS SCIENCE↗

Neutron time of flight (nToF) detectors for inertial fusion experiments

Neutrons generated in Inertial Confinement Fusion (ICF) experiments provide valuable information to interpret the conditions reached in the plasma. The neutron time-of-flight (nToF) technique is well suited for measuring the neutron energy spectrum due to the short time (100 ps) over which neutrons are typically emitted in ICF experiments. By locating detectors 10s of meters from the source, the neutron energy spectrum can be measured to high precision. Here, we present a contextual review of the current state of the art in nToF detectors at ICF facilities in the United States, outlining the physics that can be measured, the detector technologies currently deployed and analysis techniques used.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Small scale tensile testing technique for measuring grain boundary strength of neutron-irradiated materials in focused ion beam systems

Irradiation induced defects on grain boundaries (GBs) can lead to GB strength degradation and cause intergranular cracking in structural materials, affecting the safe operation and service life of nuclear reactors. Establishing the quantitative relationship between the strength and character/microchemistry for individual GB in an effort of integrating experimental measurements and multiscale simulations.

36 MATERIALS SCIENCE↗

A study of the radiation environment on board the space shuttle flight STS-57

A joint NASA-Russian study of the radiation environment inside a SPACEHAB 2 locker on space shuttle flight STS-57 was conducted. The shuttle flew in a nearly circular orbit of 28.5 deg inclination and 462 km altitude. The locker carried a charged particle spectrometer, a tissue equivalent proportional counter (TEPC), and two area passive detectors consisting of combined NASA plastic nuclear track detectors (PNTD's) and thermoluminescent detectors (TLD's), and Russian nuclear emulsions, PNTD's, and TLD's. All the detector systems were shielded by the same shuttle mass distribution. This makes possible a direct comparison of the various dose measurement techniques. In addition, measurements of the neutron energy spectrum were made using the proton recoil technique. The results show good agreement between the integral LET spectrum of the combined galactic and trapped particles using the tissue equivalent proportional counter and track detectors between about 15 keV/micron and 200 keV/micron. The LET spectrum determined from nuclear emulsions was systematically lower by about 50%, possibly due to emulsion fading. The results show that the TEPC measured an absorbed dose 20% higher than TLD's, due primarily to an increased TEPC response to neutrons and a low sensitivity of TLD's to high LET particles under normal processing techniques. There is a significant flux of high energy neutrons that is currently not taken into consideration in dose equivalent calculations. The results of the analysis of the spectrometer data will be reported separately.

Badhwar, G. D.↗

Nondestructive property and defect characterization using X-rays and neutrons

As advanced manufacturing (AM) continues to mature as a fabrication technique, interest in its use for the fabrication of nuclear components continues to grow. AM nuclear parts offer the ability to create parts with complex and non-standard geometries that cannot be produced using traditional manufacturing techniques, circumvention of supply chain issues, and reduction of time from design to implementation. However, components fabricated with AM techniques must undergo nondestructive examination (NDE) to ensure they are fabricated to the required specifications to ensure safe and proper operation. The Advanced Materials and Manufacturing Technologies (AMMT) program has undertaken initial exploratory studies on several NDE techniques to evaluate their feasibility for research and development (R&D), as well as Quality Assurance and Quality Control (QA/QC), and in-service inspections of AM parts. This work describes research results on several techniques, including X-ray and neutron tomography and scattering, as well as photothermal radiometry. The experimental results are described and an overview for each techniques’ potential use on AM parts in the various phases of part development and lifetime is given. Finally, future directions for technique development and application to AM nuclear components are described.

36 MATERIALS SCIENCE↗

Modeling of a spatially resolved ion temperature diagnostic for inertial confinement fusion

Here, the performance of modern laser-driven inertial confinement fusion (ICF) experiments is degraded by contamination of the deuterium–tritium (DT) fuel with high-Z material during compression. Simulations suggest that this mix can be described by the ion temperature distribution of the implosion, given that such contaminants deviate in temperature from the surrounding DT plasma. However, existing neutron time-of-flight (nTOF) diagnostics only measure the spatially integrated ion temperature. This paper describes the techniques and forward modeling used to develop a novel diagnostic imaging system to measure the spatially resolved ion temperature of an ICF implosion for the first time. The technique combines methods in neutron imaging and nTOF diagnostics to measure the ion temperature along one spatial dimension at yields currently achievable on the OMEGA laser. A detailed forward model of the source and imaging system was developed to guide instrument design. The model leverages neutron imaging reconstruction algorithms, radiation hydrodynamics and Monte Carlo simulations, optical ray tracing, and more. The results of the forward model agree with the data collected on OMEGA using the completed diagnostic. The analysis of the experimental data is still ongoing and will be discussed in a separate publication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced manufacturing of 3D custom boron-carbide collimators designed for complex environments for neutron scattering

Scattered-beam collimation is a very useful method to reduce unwanted backgrounds and to boost the desired sample signal instead. This approach is of particular interest for samples contained within a complex environment that gives rise to much unwanted parasitic scatter. As neutron scattering instrument and techniques advances, small samples are becoming of more and more interest, which necessitates optimized collimation. Here, in this work, we describe a concept for the design and fabrication of advanced scattered-beam collimation 3D printed from B 4 C specifically tailored for samples contained within a complex environment. This concept is demonstrated through the use of a diamond anvil cell for high pressure experimentation, a technique that very typically requires small samples. The collimators here are designed through a modeling procedure via Monte Carlo neutron ray tracing that encompasses the entire system: the instrument, the complex environment and the collimator. Since the first approach of simply scaling up of the print-size was not successful, a novel concept of a multi-part alternate-blade collimator was developed. This approach addresses printing constraints but gives greater flexibility in design. Its performance is computationally compared against an unprintable progressively tighter blade collimator to assess the effect of alternating blades. No strong difference was observed. Its performance was validated through experimentation at the Spallation Neutron Source. The results emphasize the critical importance of ultra-high precision alignment while showing good overall agreement between simulation and experiment and underscore the feasibility of the method and its real-world application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spot size measurement of a deuterium–tritium dense plasma focus using neutron radiography

Neutron radiography is a technique uniquely suited to applications in nuclear diagnostics, non-destructive testing, and subcritical experiments. The spatial resolution of neutron radiographs is degraded by optical blur in the imaging system and the neutron source size, where the ideal source is point-like to optimize the point-spread function. A potential neutron source for radiography is the dense plasma focus (DPF), a coaxial Z-pinch that produces thermonuclear and beam-target neutrons. To assess if the source size is suitable for radiography, a neutron imaging system was used to measure the source size of the 4 MA Sodium DPF at the Nevada National Security Site operating with deuterium–tritium gas-fill. The source size was measured using the edge-spread function of tungsten objects, each having a rolled (convex) edge. The spot size was found to be 7–12 mm full-width at half-max (FWHM) assuming a Gaussian source, though comparison is presented for Lorentzian and Bennett distributions. The average FWHM was found to be 8.6 ± 1.2 mm vertically and 10.8 ± 1.2 mm horizontally with respect to the image plane, averaging over varied edges and alignments. The results were sensitive to source alignment and edge metrology, which introduced notable uncertainties. These results are consistent with separate experimental measurements as well as magnetohydrodynamics simulations of this DPF, which suggest that neutron production can originate from pinches ∼5–7 mm off-axis. These results suggest that the DPF should be used for radiography at low magnification (M < 1) where spot size does not dominate spatial blur.

47 OTHER INSTRUMENTATION↗

Optimising Foil Selection for Neutron Activation Systems

Abstract Neutron spectrum unfolding using activation foils is currently the primary technique planned for measuring the neutron energy spectrum at the first wall of power-generating fusion reactors. Room for improvement in the effectiveness of current foil selection was identified, and a program produced to select foils procedurally in order to maximise the accuracy of the unfolding procedure. Using Kullback–Leibler Divergence to quantify the accuracy, the spectrum unfolded by the procedurally selected set of foils is found to be more accurate than the spectrum unfolded by a set of foils used in the literature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced techniques for determining long term compatibility of materials with propellants

A method for the prediction of propellant-material compatibility for periods of time up to ten years is presented. Advanced sensitive measurement techniques used in the prediction method are described. These include: neutron activation analysis, radioactive tracer technique, and atomic absorption spectroscopy with a graphite tube furnace sampler. The results of laboratory tests performed to verify the prediction method are presented.

Green, R. L.↗

High-order harmonics and the reverse of the squaring up process in the triangular-lattice magnet HoPdAl 4 ⁢Ge 2

We uncover high-order harmonics and the reverse of the squaring-up process, in terms of analyzing the evolution of magnetic orders in a centrosymmetric layered triangular-lattice magnet HoPdAl 4 ⁢Ge 2 , based on a detailed study of the crystal structure, magnetic susceptibility, magnetization, heat capacity, and magnetic structure. Temperature dependencies of magnetic susceptibility and heat capacity show two magnetic transitions at T N = 10.5 K and T t = 5.5 K. Below T N , Ho 3+ spins order antiferromagnetically as a transverse spin-density wave with the propagation vector k 1 = (001.5 – δ) with δ ≈ 0.18. Upon further cooling through T t , the high-order harmonics with k n = (001.5 – nδ), n = 3, 5, 7 develop, suggesting a squaring-up process. It is surprising that the squaring-up process does not continue down to 0 K but reverses the trend below 3 K. Magnetic-field-induced metastable transitions were observed in M⁡(H) curves with the fields applied both parallel and perpendicular to the triangular-lattice plane. Neutron-diffraction results suggest that the magnetization process in HoPdAl 4 ⁢Ge 2 involves the conversion of k n = (001.5 – n⁢δ) with n = 1, 3, 5, 7, to a ferromagnetic k F = (000) component. It is worth noting that the already weak seventh harmonic magnetic peak is enhanced by applying a small magnetic field in the ab plane at 1.5 K or warming up to 3 K, accompanied by a slight decrease of δ.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Gantryless Associated-Particle Neutron Radiography

The present work reports on the development of techniques for in-field fast-neutron radiography measurements using the associated-particle imaging (API) method. The API method employs alpha-neutron coincidences from the d+t→α+n reaction to enable fast neutron transmission imaging with excellent contrast using a wide cone beam. However, for field radiography applications, the API method is burdened by the need for the relative positions of the source and detector to be known. Fortunately, these relative positions can be inferred from transmission data. The inferred positions also enable accurate stitching of multiple images into a composite image even when using a low-resolution detector panel and acquiring images having few overlapping pixels. The developed techniques address analysis of measurements where (1) the source and detector panel are separately hand positioned rather than held in registration by a gantry, (2) multiple detector panel positions within the “coincident cone” of tagged neutrons are required to piece together an image of an item of interest, and (3) normalization measurements that have identical source-detector positioning but without the inspected object are not possible. The present work will describe the system calibrations (including timing calibrations and neutron direction calibrations) necessary for subsequent analyses, the method of locating the detector in the coincident cone of neutrons with millimeter precision using the timing and directions of coincident neutrons, the method of calculating a normalization image for a given detector panel position, and the method used to project multiple images into a common image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗