Search NASA⌕ Search

SEARCH · Search NASA

Results for “nuclear spectral function”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Spectral restoration in high resolution electron energy loss spectroscopy based on iterative semi-blind Lucy-Richardson algorithm applied to rutile surfaces

A new spectral restoration algorithm of reflection electron energy loss spectra is proposed. It is based on the maximum likelihood principle as implemented in the iterative Lucy-Richardson approach. Resolution is enhanced and point spread function recovered in a semi-blind way by forcing cyclically the zero loss to converge towards a Dirac peak. Synthetic phonon spectra of TiO{sub 2} are used as a test bed to discuss resolution enhancement, convergence benefit, stability towards noise, and apparatus function recovery. Attention is focused on the interplay between spectral restoration and quasi-elastic broadening due to free carriers. A resolution enhancement by a factor up to 6 on the elastic peak width can be obtained on experimental spectra of TiO{sub 2}(110) and helps revealing mixed phonon/plasmon excitations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimizing the performance of bandpass photon detectors for inverse photoemission: Transmission of alkaline earth fluoride window crystals

Bandpass photon detectors are widely used in inverse photoemission in the isochromat mode at energies in the vacuum-ultraviolet spectral range. The energy bandpass of gas-filled counters is usually formed by the ionization threshold of the counting gas as high-pass filter and the transmission cutoff of an alkaline earth fluoride window as low-pass filter. The transmission characteristics of the window have, therefore, a crucial impact on the detector performance. We present transmission measurements in the vacuum-ultraviolet spectral range for alkaline earth fluoride window crystals in the vicinity of the transmission cutoff as a function of crystal purity, surface finish, surface contamination, temperature, and thickness. Our findings reveal that the transmission characteristics of the window crystal and, thus, the detector performance depend critically on these window parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectral function for 4 He using the Chebyshev expansion in coupled-cluster theory

Here, we compute spectral function for 4 He by combining coupled-cluster theory with an expansion of integral transforms into Chebyshev polynomials. Our method allows us to estimate the uncertainty of spectral reconstruction. The properties of the Chebyshev polynomials make the procedure numerically stable and considerably lower in memory usage than the typically employed Lanczos algorithm. We benchmark our predictions with other calculations in the literature and with electron-scattering data in the quasi-elastic peak. The spectral function formalism allows one to extend ab initio lepton-nucleus cross sections into the relativistic regime. This makes it a promising tool for modeling this process at higher-energy transfers. The results we present open the door for studies of heavier nuclei, important for the neutrino oscillation programs.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Relation between a three-parameter formula for isotope shifts and staggering parameters

It is noted that the staggering parameters used to describe even-odd effects for isotope shifts can in some cases exhibit very rapidly varying behavior as a function of neutron number. On the other hand, a three-parameter formula (3P) with fixed coefficients can explain the same behavior in the A=40 region.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of Delayed-Particle Emission Signatures for Pyroprocessing. Part 1: ABTR Fuel Assembly

A three-part study is conducted using the MCNP6 Monte Carlo radiation-transport code to calculate delayed-neutron (DN) and delayed-gamma (DG) emission signatures for nondestructive assay (NDA) metal-fuel pyroprocessing. In Part 1, MCNP6 is used to produce irradiation-induced used nuclear fuel (UNF) isotopic inventories for an Argonne National Laboratory (ANL) Advanced Burner Test Reactor (ABTR) preconceptual design fuel assembly (FA) model. The initial fuel inventory consists of uranium mixed with light-water-reactor transuranic (TRU) waste and 10 wt% zirconium (U-LWR-SFTRU-10%Zr). To facilitate understanding, parametric evaluation is done using models for 3% and 5% initial 235 U a% enrichments, burnups of 5, 10, 15, 20, 30, …, 120 GWd/MTIHM, and 3-, 5-, 10-, 20-, and 30- year cooling times. Detailed delayed-particle radioisotope source terms for the irradiate FA are created using BAMF-DRT and SOURCES3A. Using simulation tallies, DG activity ratios (DGARs) are developed for 134 Cs/ 137 Cs 134 Cs/ 154 Eu, and 154 Eu/ 137 Cs markers as a function of (1) burnup and (2) actinide mass, including elemental uranium, neptunium, plutonium, americium, and curium. Spectral-integrated DN emission is also tallied. The study reveals a rich assortment of DGAR behavior as a function of DGAR type, enrichment, burnup, and cooling time. Similarly, DN emission plots show variation as a function of burnup and of actinide mass. Sensitivity of DGAR and DN signatures to initial 235 U enrichment, burnup, and cooling time is evident. Comparisons of the ABTR radiation signatures and radiation signatures previously reported for a generic Westinghouse oxide-fuel assembly indicate that there are pronounced differences in the ABTR and Westinghouse oxide-fuel DN and DG signatures. These differences are largely attributable to the initial TRU inventory in the ABTR fuel. The actinide and nonactinide inventories for the FA models serve as source materials for the pre- and postelectrorefining models to be reported in Parts 2 and 3.

07 ISOTOPE AND RADIATION SOURCES↗

Neutron spectroscopy and spectral unfolding with 4 He fast neutron scintillators

Time-of-flight measurements were performed to determine the 4 He pressurized fast neutron scintillation detectors response function and the ability of the detectors to be applied as a spectrometer. An experimentally validated neutron energy response function was used in conjunction with an iterative least squares unfolding technique to unfold a 252 Cf spontaneous fission spectrum, a PuBe (α, n) spectrum, and a deuterium-deuterium (D-D) fusion reaction spectrum. In conclusion, the ability of the detectors to retain incident neutron energies makes them suitable for applications such as nuclear non-proliferation and spent nuclear fuel monitoring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pair dynamics and the intermolecular nuclear Overhauser effect (NOE) in liquids analysed by simulation and model theories: Application to an ionic liquid

Combining simulation and model theories, this paper analyses the impact of pair dynamics on the intermolecular nuclear Overhauser effect (NOE) in liquids. For the first time, we give a distance resolved NOE. When applied to the ionic liquid 1-ethyl-3-methyl-imidazolium tetrafluoroborate the NOE turns out to be of long-range nature. This behaviour translates to the experimentally measured cross- and longitudinal relaxation rates. We were able to calculate the heteronuclear NOE from simulation data, despite the high computational effort. Model theories are computationally less demanding and cover the complete frequency range of the respective spectral density function, they are usually based on a very simple pair distribution function and the solution of the diffusion equation. In order to model the simulated data sufficiently, these simplifications in structure and dynamics have to be generalised considerably.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of charge inhomogeneities on elementary excitations in La 2-x Sr x CuO₄

Purely local experimental probes of many copper oxide superconductors show that their electronic states are inhomogeneous in real space. For example, scanning tunneling spectroscopic imaging shows strong variations in real space, and according to nuclear quadrupole resonance (NQR) studies, the charge distribution in the bulk varies on the nanoscale. However, the analysis of the experimental results utilizing spatially averaged probes often ignores this fact. We have performed a detailed investigation of the doping dependence of the energy and linewidth of the zone-boundary Cu-O bond-stretching vibration in La 2-x Sr x CuO₄ by inelastic neutron scattering. Both our results as well as previously reported angle-dependent momentum widths of the electronic spectral function detected by angle-resolved photoemission can be reproduced by including the same distribution of local environments extracted from the NQR analysis.

Park, S. R.↗

Impact of Two-Body Currents on Semi-Exclusive Lepton-Nucleus Reactions

We generalize the spectral-function formalism to describe two-nucleon knockout processes in exclusive kinematics. Significant improvements are introduced both in the treatment of the current operators entering the $Δ$-current contribution and in the modeling of correlations between the two struck nucleons, including a consistent treatment of isospin dependence and the explicit incorporation of angular correlations. The framework is validated through comparisons with relativistic Fermi-gas calculations and with semi-exclusive electron-nucleus scattering data. Our results demonstrate that an accurate description of nuclear dynamics plays a crucial role in modeling this reaction mechanism. We further present a study of selected electroweak observables relevant to neutrino-scattering experiments.

Rocco, N. [Fermilab; Valencia U., IFIC] (ORCID:000↗

Impact of Two-Body Currents on Semi-Exclusive Lepton-Nucleus Reactions

We generalize the spectral-function formalism to describe two-nucleon knockout processes in exclusive kinematics. Significant improvements are introduced both in the treatment of the current operators entering the $Δ$-current contribution and in the modeling of correlations between the two struck nucleons, including a consistent treatment of isospin dependence and the explicit incorporation of angular correlations. The framework is validated through comparisons with relativistic Fermi-gas calculations and with semi-exclusive electron-nucleus scattering data. Our results demonstrate that an accurate description of nuclear dynamics plays a crucial role in modeling this reaction mechanism. We further present a study of selected electroweak observables relevant to neutrino-scattering experiments.

Rocco, N. [Fermilab; Valencia U., IFIC] (ORCID:000↗

Impact of Two-Body Currents on Semi-Exclusive Lepton-Nucleus Reactions

We generalize the spectral-function formalism to describe two-nucleon knockout processes in exclusive kinematics. Significant improvements are introduced both in the treatment of the current operators entering the $Δ$-current contribution and in the modeling of correlations between the two struck nucleons, including a consistent treatment of isospin dependence and the explicit incorporation of angular correlations. The framework is validated through comparisons with relativistic Fermi-gas calculations and with semi-exclusive electron-nucleus scattering data. Our results demonstrate that an accurate description of nuclear dynamics plays a crucial role in modeling this reaction mechanism. We further present a study of selected electroweak observables relevant to neutrino-scattering experiments.

Rocco, N. [Fermilab; Valencia U., IFIC] (ORCID:000↗

Impact of Two-Body Currents on Semi-Exclusive Lepton-Nucleus Reactions

We generalize the spectral-function formalism to describe two-nucleon knockout processes in exclusive kinematics. Significant improvements are introduced both in the treatment of the current operators entering the $Δ$-current contribution and in the modeling of correlations between the two struck nucleons, including a consistent treatment of isospin dependence and the explicit incorporation of angular correlations. The framework is validated through comparisons with relativistic Fermi-gas calculations and with semi-exclusive electron-nucleus scattering data. Our results demonstrate that an accurate description of nuclear dynamics plays a crucial role in modeling this reaction mechanism. We further present a study of selected electroweak observables relevant to neutrino-scattering experiments.

Rocco, N. [Fermilab; Valencia U., IFIC] (ORCID:000↗

A synchrotron-radiation-based variable angle ellipsometer for the visible to vacuum ultraviolet spectral range

A rotating analyzer spectroscopic polarimeter and ellipsometer with a wide-range θ-2θ goniometer installed at the Insertion Device Beamline of the Metrology Light Source in Berlin is presented. With a combination of transmission- and reflection-based polarizing elements and the inherent degree of polarization of the undulator radiation, this ellipsometer is able to cover photon energies from about 2 eV up to 40 eV. Additionally, a new compensator design based on a CaF{sub 2} Fresnel rhomb is presented. This compensator allows ellipsometric measurements with circular polarization in the vacuum ultraviolet spectral range and thus, for example, the characterization of depolarizing samples. The new instrument was initially used for the characterization of the polarization of the beamline. The technical capabilities of the ellipsometer are demonstrated by a cohesive wide-range measurement of the dielectric function of epitaxially grown ZnO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-Energy Density science at the Linac Coherent Light Source

The Matter in Extreme Conditions end station at the Linac Coherent Light Source holds great promise for novel pump-probe experiments to make new discoveries in high- energy density science. Recently, our experiments have demonstrated the first spectrally- resolved measurements of plasmons using a seeded 8-keV x-ray laser beam. Forward x-ray Thomson scattering spectra from isochorically heated solid aluminum show a well-resolved plasmon feature that is down-shifted in energy by 19 eV from the incident 8 keV elastic scattering feature. In this spectral range, the simultaneously measured backscatter spectrum shows no spectral features indicating observation of collective plasmon oscillations on a scattering length comparable to the screening length. Moreover, this technique is a prerequisite for Thomson scattering measurements in compressed matter where the plasmon shift is a sensitive function of the free electron density and where the plasmon intensity provides information on temperature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Empirical Refinement of the GADRAS Detector Response Function

The Gamma Detector Response and Analysis Software (GADRAS) was augmented to enable empirical refinement of the Detector Response Function (DRF) for gamma-ray detectors. This capability is included in GADRAS starting with Version 18.8.2, which was released in February 2019 Empirical refinement enables improved computational accuracy for gamma-ray spectra when detectors exhibit characteristics that are essentially unique to a particular sensor. This report discusses how to perform the empirical refinement, and examples are presented for the following scenarios where empirical refinement is appropriate: Large plastic scintillators, which are generally composed of polyvinyl toluene (PVT), often exhibit low-energy peaks that are not associated with incident gamma rays. Regardless of whether they are artifacts produced by poor light collection or pulse processing methods, accurate spectral synthesis requires replication of these features; Some detectors, particularly those using Silicon Photomultipliers (SiPM), exhibit energy shifts of Compton edges and escape peaks relative to the same scintillator material attached to a photomultiplier tube. Empirical refinement compensates for these effects, which derive from nonlinearities in the detector response; The change in the DRF as a function of displacement of the source relative to the detector axis cannot always be replicated adequately using only the few shielding parameters that are used by the response function. Empirical refinement enables improved accuracy for computation of spectra during linear transits or when the detector is close to a large radiation source. This is a particularly important consideration for collimated detectors; and, Gamma-ray imagers exhibit complex relationships between spectral response and spatial locations. Empirical refinement enables substantial improvement of the DRF accuracy for imagers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microscope spectrometer for light scattering investigations

We describe a setup including a microscope to study volumes of a few {mu}m{sup 3} by static and dynamic light scattering (DLS) in a backscattering configuration. Light scattered by individual objects of micrometric size can be analyzed in the 400-800 nm spectral range. This setup can also be employed to study both diluted and concentrated colloidal solutions by DLS measurements. For diluted solutions we found evidence of the fluctuations of the number of particles in a confocal volume. We discuss their contribution to the autocorrelation function of the scattered intensity measured as a function of time.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Waste Characterization Methods Based on Gamma-ray Imaging Spectrometers - 19454

Characterization of LLW, ILW, U, NORM and TENORM is critical to the nuclear industry's bottom line. Accurate measurements enable the disposal of waste at the lowest possible cost. In the past the most accurate technology available involved using HPGe detectors and extensive system modeling to estimate the total source term given what the user knows about the geometry of the source and any shielding between the source and the detectors. Now there are a variety of imaging detectors that are available commercially, including CZT and HPGe detectors that achieve energy resolution ≤1% FWHM at 662 keV. These devices couple the traditional high resolution spectroscopic analysis with next generation gamma-ray imaging information to more accurately characterize the radiation source term. Uncertainties in the source location will result in significant error in the characterization of an object's radioactivity. It is helpful if the object can be spun, such as a barrel, so that any asymmetry in the source distribution is averaged out from the detector's point of view. Even in the case of a spinning barrel it is important to determine if the radiation is concentrated near the center of the barrel or distributed near the edge. The closer one measures to a barrel, which usually dictates the time required to acquire data, the more these spatial variations in the source distribution will affect the calculated activity of each isotope. This paper will focus on showing the use of CZT imaging spectrometers to characterize complicated radiation source terms. The radiation images are used to determine where the source term should be defined in a radiation transport model that calculates the expected number of photopeak counts for each isotope detected. This is used to calculate the activity of the source. The transport model is used to determine the attenuation of the radiation source term through distance and shielding material, but the detection efficiency is based solely on radiation measurement data. These measurements are taken with a robotic source positioning device that allows for detailed directional efficiency calibration. It is a fully automated system where a detector is loaded into the device and all of the efficiency curves are captured as a function of direction by creating new measurements for each location the robot positions the source. These measurements are tagged with the true source location and the efficiency curve is calculated for each measurement. This is used to create a response function matrix as a function of energy and incident direction which is used to convert the direction dependent flux on the detector head determined from the simulation model to the expected number of counts per unit activity of each isotope of interest. The results of these source term reconstructions in both the spatial and spectral domain will be shown. The impact of improper specification of the source term will be shown for a few standard waste characterization scenarios to demonstrate the importance of proper source location determination. Finally, the underlying calibration method and some sample efficiency curves as a function of direction will be shown to demonstrate the importance of calibrating out directional response functions in imaging devices (which often have a strong forward sensitivity bias). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Transitions in eigenvalue and wavefunction structure in (1+2)-body random matrix ensembles with spin

Finite interacting Fermi systems with a mean-field and a chaos generating two-body interaction are modeled by one plus two-body embedded Gaussian orthogonal ensemble of random matrices with spin degree of freedom [called EGOE(1+2)-s]. Numerical calculations are used to demonstrate that, as lambda, the strength of the interaction (measured in the units of the average spacing of the single-particle levels defining the mean-field), increases, generically there is Poisson to GOE transition in level fluctuations, Breit-Wigner to Gaussian transition in strength functions (also called local density of states) and also a duality region where information entropy will be the same in both the mean-field and interaction defined basis. Spin dependence of the transition points lambda{sub c}, lambda{sub F}, and lambda{sub d}, respectively, is described using the propagator for the spectral variances and the formula for the propagator is derived. We further establish that the duality region corresponds to a region of thermalization. For this purpose we compared the single-particle entropy defined by the occupancies of the single-particle orbitals with thermodynamic entropy and information entropy for various lambda values and they are very close to each other at lambda=lambda{sub d}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗