Experimental Study of Nonane and Nonane/Hexanol Fuel Droplet Combustion in Microgravity

In this presentation we review experiments carried out on nonane droplets, and a nonane/hexanol droplet, burning in microgravity to promote spherical symmetry. The nonane/hexanol combination was selected for the following reasons: 1) the spherically symmetric burning history of nonane and nonane/hexanol mixtures has not been previously studied; 2) measurements of the burning history of pure nonane droplets in air extend the existing data base of spherical droplet flames of soot-producing fuels which are useful for testing detailed chemical kinetic models of the spherically symmetric droplet burning process; 3) nonane and hexanol have almost identical boiling points so heterogeneous nucleation on a support fiber is unlikely; 4) hexanol does not have a strong propensity for water vapor absorption; 5) hexanol produces less soot than nonane so that mixtures of nonane and hexanol should show an effect of composition on soot formation. The far-field gas was atmospheric pressure air at room temperature. The evolution of droplet diameter was measured using high speed cine photography of spark-ignited droplets within a confined volume in a drop tower. The importance of soot formation during droplet combustion is derived from the fact that soot is the basic component of the particulate emission process that occurs in spray combustion. The complexity of soot formation motivates a one-dimensional transport condition which is advantageous for modeling. Recent numerical studies of droplet combustion have assumed spherical symmetry when incorporating such aspects as detailed chemistry and radiation, though soot formation itself has not yet been included in any droplet combustion modeling effort. If radiation is not important as would be the case for'small' droplets (i.e., droplets with initial diameters less than about ]mm), soot formation can lead to a nonlinear burning process and a time-varying burning rate, (non-linear burning of a non-sooting fuel like methanol is due to water vapor absorption on the droplet. The classical quasi-steady droplet burning theory predicts a linear evolution of droplet diameter in scaled coordinates for any fuel type.

Avedisian, C. T.↗

Orientation Effects in Two-Phase Microgap Flow

The high power density of emerging electronic devices is driving the transition from remote cooling, which relies on con-duction and spreading, to embedded cooling, which extracts dissipated heat on-site. Two-phase microgap coolers employ the forced flow of dielectric fluids undergoing phase change in a heated channel within or between devices. Such coolers must work reliably in all orientations for a variety of applications (e.g., vehicle-based equipment), as well as in microgravity and high-g for other applications (e.g., spacecraft and aircraft). The lack of acceptable models and correlations for orientation- and gravity-independent operation has limited the use of two-phase coolers in such applications. Previous research has revealed that gravita-tional acceleration plays a diminishing role in establishing flow regimes and transport rates as the channel size shrinks, but there is considerable variation among the proposed microscale criteria and limited research on two-phase flows in low aspect ratio mi-crogap channels. Reliable criteria for achieving orientation- and gravity-independent flow boiling would enable emerging sys-tems to exploit this thermal management technique and streamline the technology development process. As a first step toward understanding the effect of gravity on two-phase microgap flow and transport, in the present effort the authors have studied the effect of evaporator orientation and mass flux on near-saturated flow boiling of HFE7100 in a 1.01 mm tall by 13.0 mm wide by 12.7 mm long microgap channel. Orientation-independence, defined as achieving similar critical heat fluxes, heat transfer coefficients, and flow regimes across evaporator orientations, was achieved for mass fluxes of 400 kg/m2-s and greater. The present results are compared to pub-lished criteria for achieving gravity-independence.

orientation↗

Automated bubble analysis of high-speed subcooled flow boiling images using U-net transfer learning and global optical flow

Capturing and analyzing the bubble dynamics is crucial to improving the understanding of boiling heat transfer mechanisms and predicting boiling heat transfer coefficient and boiling crisis. High speed video (HSV) imaging has been used for decades towards this end. Still, there is no universal approach to quantitatively analyze bubble dynamics from HSV images. In this study, we propose a data-driven post-processing approach to segment, track, and identify wall-attached vapor bubbles from HSV images of the boiling process in subcooled flow conditions. Firstly, we employ a transfer learning framework with a U-Net-based convolution neural network (CNN) architecture to detect and segment bubbles in HSV images of diverse contrast and surface texture using very little data (e.g., 10 images) for training. Then, we evaluate the trained CNN model with 100 ground-truth images, and the validation results show that the model accuracy and precision in detecting the optical footprint of bubbles are higher than 90%. Finally, we suggest a criterion to identify a condensing bubble based on the divergence of the bubble displacement, which is calculated from sequential segmented bubble images using a global optical flow code. Using this combination of machine learning and optical flow, we can identify nucleation sites and track the growth of bubbles nucleating at each site to quantify nucleation site density, nucleation frequency, and other fundamental boiling parameters. The proposed system is validated using results obtained on a special heater, which enables both infrared (IR) thermometry and HSV imaging on a metallic surface. We compare the fundamental boiling parameters obtained by the two different diagnostics. The results show good agreement. In conclusion, the difference between the measurements of nucleation site density, averaged nucleation frequency, and averaged growth time performed with the two techniques is always within ± 20% and mostly ± 10% of the values measured with IR thermometry.

42 ENGINEERING↗

Effect of PVD-coated chromium on the subcooled flow boiling performance of nuclear reactor cladding materials

Here we elucidate the separate effect of a thin Cr coating deposited by physical vapor deposition (PVD) on the subcooled flow boiling performance of zircaloy-4. First, we run flow boiling experiments on prototypical zircaloy-4 surfaces mimicking the scratch pattern and surface roughness of nuclear reactor claddings. Then, we PVD-coat a 0.3 µm thick chromium layer on the same exact surface and repeat the same flow boiling investigations. All experiments are run using deionized water at atmospheric pressure, flowing on a 1 × 3 cm 2 rectangular cross section channel at a rate of 1000 kg/m 2 /s and a subcooling of 10 K. We measure the average temperature of the boiling surface at increasing surface heat fluxes, covering a wide range of heat transfer regimes, from single-phase forced convection to the boiling crisis. We also record high-speed videos of the boiling process, which we postprocess to measure bubble nucleation site density, growth time, departure diameter and frequency. The surface analysis reveals that, while the chromium coating does not seem change the surface roughness and morphology, it improves surface wettability. However, it decreases the critical heat flux. The chromium coating causes an increase of nucleation temperature, bubble departure diameter and growth time, and a reduction of the nucleation site density. The concurrence of these observations indicates that a size reduction of the nucleation sites, conformally covered by the chromium coating, may be the cause of the boiling performance deterioration. We confirm this hypothesis repeating the same analysis on a FeCrAl sample prepared and tested using the same protocol as the zircaloy-4 sample, but with a different initial surface texture.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Orientation Effects in Two-Phase Microgap Flow

The high power density of emerging electronic devices is driving the transition from remote cooling, which relies onconduction and spreading, to embedded cooling, which extracts dissipated heat on-site. Two-phase microgap coolersemploy the forced flow of dielectric fluids undergoing phase change in a heated channel within or between devices. Such coolers must work reliably in all orientations for a variety of applications (e.g., vehicle-based equipment), as well as in microgravity and high-g for other applications (e.g., spacecraft and aircraft). The lack of acceptable models andcorrelations for orientation- and gravity-independent operation has limited the use of two-phase coolers in suchapplications. Previous research has revealed that gravitational acceleration plays a diminishing role in establishing flow regimes and transport rates as the channel size shrinks, but there is considerable variation among the proposed microscale criteria and limited research on two-phase flows in low aspect ratio microgap channels. Reliable criteria for achieving orientation- and gravity-independent flow boiling would enable emerging systems to exploit this thermal management technique and streamline the technology development process.

orientation↗

Pool boiling on metal-foam enhanced tube bundle: heat transfer characteristics and flow visualization

A flooded evaporator configuration is common in large central air conditioning or process cooling systems. It is basically a shell and tube heat exchanger, in which a secondary fluid (brine or water) circulates inside the tube bundle and is cooled by the vaporization of the refrigerant on the outside surface of the tubes. The enhanced pool boiling process enables the compact design of flooded evaporators, which substantially reduces the refrigerant charge. High-porosity metal foam, with a large surface-area-to-volume ratio, could provide an extended heat transfer area and a high-density of nucleation sites. This study experimentally investigated the pool boiling heat transfer and flow characteristics on metal-foam enhanced tube bundles. The enhanced bundle consists of four aluminum tubes with aluminum foam brazed around the outer surface, which are horizontally mounted in a staggered arrangement. The results showed that the metal-foam enhanced tube bundles improved the heat transfer coefficient by 100-160% with a lower wall temperature difference of 1-10°C, compared to the baseline. In addition, the tube pitch played a significant role in determining the pool boiling behavior of the tube bundles.

Yang, Cheng-Min↗

Investigating the Role π -Rich Solvents Play in the Growth of Cesium Lead Bromide Nanocrystals

In this report, the role that a high-boiling-point solvent type plays on the nucleation and growth, morphology, and crystal-phase transformation of cesium lead bromide nanocrystals (CsPbBr 3 ) is studied. The CsPbBr 3 products were compared between a one-pot growth mechanism at room temperature (RT) versus a hot-injection mechanism (HI) control using dibenzyl ether (DBE), diphenyl ether (DPE), dioctyl ether (DOE), or 1- octadecene (ODE). The coordination between these solvents and the PbBr 2 salt precursors resulted in different plumbate [PbSBr n ] 2−n precursors being formed. The S-to-Pb 2+ coordination within [PbSBr n ] 2−n was probed by UV−vis and solvent-phase 207 Pb NMR, both of which showed considerable coordination between [PbSBr n ] 2−n and the π-rich DBE and DPE, whose reactivity affected CsPbBr 3 growth. The effect was more pronounced for CsPbBr 3 prepared via RT, where the morphology was tunable, with π-rich solvents producing thin rod-like CsPbB r3 with a blue emission, compared to the green-emitting thicker platelets formed via HI. While XRD showed crystalline products for both RT and HI, with orthorhombic and cubic forms, respectively, the RT products had considerable surface defects, as was indicated by lower quantum yields, and to understand this the photoluminescent lifetimes were measured by time-correlated single photon counting.

207Pb NMR↗

Numerical analysis of coalescence-induced bubble departure for enhanced boiling heat transfer

Boiling heat transfer plays a crucial role in a wide range of applications, such as power generation, refrigeration, electronics cooling, and pharmaceutics. Among the various factors that influence boiling heat transfer, the dynamics of vapor bubble nucleation, growth, and departure from the heated surface stand out as particularly important. An emerging phenomenon that can promote the departure of bubbles smaller than the Fritz diameter is coalescence-induced departure. If the dynamics of this process are fully understood, then surfaces can be engineered to promote faster bubble departure and substantially increase the performance of boiling heat transfer. Further, this work expands on published results by presenting a detailed numerical analysis of bubble coalescence and departure for a range of initial bubble diameters and size ratios between coalescing bubbles. Analysis of the results is focused on explaining how the release of surface energy and bubble surface dynamics lead to bubble departure, as well as fundamentally distinguishing capillary–inertial jumping and buoyant–inertial departure mechanisms across different bubble sizes and size ratios. The results show that both the initial sizes of the coalescing bubbles and the ratio between their sizes can determine whether the merged bubble will leave the surface through capillary–inertial jumping or buoyant departure. Below a certain bubble size, the release of surface energy by the merger is not sufficient to propel the merged bubble from the surface.

42 ENGINEERING↗

Analysis of the Pressure Rise in a Partially Filled Liquid Tank in Microgravity with Low Wall Heat Flux and Simultaneous Boiling and Condensation

Experiments performed with Freon 113 in the space shuttle have shown that in a pro- cess of very slow heating, high liquid superheats can be sustained for a long period in microgravity. In a closed system explosive vaporization of superheated liquid resulted in pressure spikes of varying magnitudes. In this paper, we analyze the pressure rise in a partially lled closed tank in which a large vapor bubble (i.e., ullage) is initially present, and the liquid is subjected to a low wall heat ux. The liquid layer adjacent to the wall becomes superheated until the temperature for nucleation of the bubbles (or the incipience of boiling) is achieved. In the absence of the gravity-induced convection large quantities of superheated liquid can accumulate over time near the heated surface. Once the incipience temperature is attained, explosive boiling occurs and the vapor bubbles that are produced on the heater surface tend to quickly raise the tank pressure. The liquid-vapor saturation temperature increases as well. These two e ects tend to induce condensation of the large ullage bubble that is initially present, and tends to mitigate the tank pressure rise. As a result, the tank pressure is predicted to rise sharply, attain a maximum, and subsequently decay slowly. The predicted pressure rise is compared with experimental results obtained in the microgravity environments of the space shuttle for Freon 113. The analysis is appli- cable, in general to heating of liquid in closed containers in microgravity and to cryogenic fuel tanks, in particular where small heat leaks into the tank are unavoidable.

Hasan, Mohammad M.↗

Hybrid Heat Pipes for Lunar and Martian Surface and High Heat Flux Space Applications

Novel hybrid wick heat pipes are developed to operate against gravity on planetary surfaces, operate in space carrying power over long distances and act as thermosyphons on the planetary surface for Lunar and Martian landers and rovers. These hybrid heat pipes will be capable of operating at the higher heat flux requirements expected in NASA's future spacecraft and on the next generation of polar rovers and equatorial landers. In addition, the sintered evaporator wicks mitigate the start-up problems in vertical gravity aided heat pipes because of large number of nucleation sites in wicks which will allow easy boiling initiation. ACT, NASA Marshall Space Flight Center, and NASA Johnson Space Center, are working together on the Advanced Passive Thermal experiment (APTx) to test and validate the operation of a hybrid wick VCHP with warm reservoir and HiK"TM" plates in microgravity environment on the ISS.

Ababneh, Mohammed T.↗

Time and Space Resolved Heat Transfer Measurements Under Nucleate Bubbles with Constant Heat Flux Boundary Conditions

Investigations into single bubble pool boiling phenomena are often complicated by the difficulties in obtaining time and space resolved information in the bubble region. This usually occurs because the heaters and diagnostics used to measure heat transfer data are often on the order of, or larger than, the bubble characteristic length or region of influence. This has contributed to the development of many different and sometimes contradictory models of pool boiling phenomena and dominant heat transfer mechanisms. Recent investigations by Yaddanapyddi and Kim and Demiray and Kim have obtained time and space resolved heat transfer information at the bubble/heater interface under constant temperature conditions using a novel micro-heater array (10x10 array, each heater 100 microns on a side) that is semi-transparent and doubles as a measurement sensor. By using active feedback to maintain a state of constant temperature at the heater surface, they showed that the area of influence of bubbles generated in FC-72 was much smaller than predicted by standard models and that micro-conduction/micro-convection due to re-wetting dominated heat transfer effects. This study seeks to expand on the previous work by making time and space resolved measurements under bubbles nucleating on a micro-heater array operated under constant heat flux conditions. In the planned investigation, wall temperature measurements made under a single bubble nucleation site will be synchronized with high-speed video to allow analysis of the bubble energy removal from the wall.

Myers, Jerry G.↗

Laboratory studies of the condensation and properties of amorphous silicate smokes

The results of experiments intended for defining the vapor phase condensation of refractory materials are reported, and the usefulness of applying laboratory data to astrophysical conditions is assessed. The testing apparatus used produced Mg-SiO smokes by boiling powders in an evaporator. Critical temperatures for the onset of nucleation were measured for SiO-H2 and Mg-SiO-H2 systems. Spectroscopic examination of the grains produced were determined to be similar to the spectra obtained from both carbonaceous chondrites and several stratospheric micrometeorites. The experiments demonstrated that direct nucleation of refractory silicates from the vapor phase yielded amorphous, metastable particles, resembling more circumstellar grains than a chondritic matrix. It is suggested that the formation of SiO(x) may control nucleation in oxygen-rich stars.

Nuth, J. A.↗

Flow boiling transient critical heat flux tests with stainless steel and FeCrAl: Transient correlation implementation, model calibration, and sensitivity analysis

In this study, steady-state and transient internal-flow critical heat flux (CHF) experiments were carried out under two flow conditions, at atmospheric pressure, on 316 stainless steel (316-SS) and iron-chromium-aluminum (FeCrAl) tubes. Slow power transients at a low mass flow (300 kg/m 2 - s) with very low subcooling (X e =-0.0054) generated premature CHFs, which were prevented by faster power transients and high mass flow (1000 kg/m 2 - s). The measured transient CHFs increased linearly with increasing power transients, compared with the steady-state CHF. Yet, the wall superheat at the CHFs decreased with faster power transients. Transient CHF correlations highlighting heterogeneous spontaneous nucleation were calibrated to the measured CHFs and compared with other existing correlations. Transient CHF multipliers were acquired from pool and flow boiling empirical CHF correlations that were generated. The multipliers were applied to the RELAP5-3D nuclear system code to analyze the discrepancies between the measured data and the predicted CHF and post-CHF behavior, which improved peak cladding temperature predictions by 24.6%. A variance-based global sensitivity study perturbing the experimental uncertainties and cladding material thermal properties showed the diminishing influence of flow boiling heat transfer with increasing power transients, highlighting the significance of the volumetric heat capacity for the cladding integrity during transients. Transient CHF correlations were applied to the most limiting design basis accident: a hot-zero-power reactivity-initiated accident on a generic pressurized water reactor RELAP5-3D model.

36 MATERIALS SCIENCE↗

Vaporizable endoskeletal droplets via tunable interfacial melting transitions

Liquid emulsion droplet evaporation is of importance for various sensing and imaging applications. The liquid-to-gas phase transformation is typically triggered thermally or acoustically by low–boiling point liquids, or by inclusion of solid structures that pin the vapor/liquid contact line to facilitate heterogeneous nucleation. However, these approaches lack precise tunability in vaporization behavior. Here, we describe a previously unused approach to control vaporization behavior through an endoskeleton that can melt and blend into the liquid core to either enhance or disrupt cohesive intermolecular forces. This effect is demonstrated using perfluoropentane (C 5 F 12 ) droplets encapsulating a fluorocarbon (FC) or hydrocarbon (HC) endoskeleton. FC skeletons inhibit vaporization, whereas HC skeletons trigger vaporization near the rotator melting transition. Our findings highlight the importance of skeletal interfacial mixing for initiating droplet vaporization. Tuning molecular interactions between the endoskeleton and droplet phase is generalizable for achieving emulsion or other secondary phase transitions, in emulsions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of experiments on condensation of nitrogen by homogeneous nucleation at states modelling those on the national transonic facility

A cryogenic wind tunnel is based on the twofold idea of lowering drive power and increasing Reynolds number by operating with nitrogen near its boiling point. There are two possible types of condensation problems involved in this mode of wind tunnel operation. They concern the expansion from the nozzle supply to the test section at relatively low cooling rates, and secondly the expansion around models in the test section. This secondary expansion involves higher cooling rates and shorter time scales. In addition to these two condensation problems it is not certain what purity of nitrogen can be achieved in a large facility. Therefore, one cannot rule out condensation processes other than those of homogeneous nucleation.

Wegener, P. P.↗

High-speed imaging of transition from fluid breakup to phase explosion in electric explosion of tungsten wires in air

High-speed visible imaging of sub-microsecond electric explosion of wires at the low specific energy deposition threshold reveals three distinct modes of wire failure as capacitor charge voltage and energy deposition are increased. For 100 micron diameter gold-plated tungsten wires of 2 cm length, deposited energies of 1.9 eV/atom produces a liquid column that undergoes hydrodynamic breakup into droplets with radii of order of wire diameter on timescales of 200 μs. Instability growth, column breakup, and droplet coalescence follow classic Rayleigh-Plateau predictions for instability of viscous fluid column. Above 3.2 eV/atom of deposited energy, wires are seen to abruptly transition to an expanding mixture of micron scale liquid-droplets and vapor within one frame (less than 3.33 μs), which has been termed ‘phase explosion’ in literature. Between these two limits, at 2.5 eV/atom of deposited energy, wire radius is unchanged for the first 10 μs before the onset of a rapid expansion and disintegration that resembles homogenous nucleation of mechanically unstable bubbles. Here, thermodynamic calculations are presented that separate cases by temperature obtained during heating: below boiling point, near boiling point, and exceeding boiling point.

42 ENGINEERING↗

Three‐Tier Hierarchical Structures for Extreme Pool Boiling Heat Transfer Performance

Abstract Boiling is an effective energy‐transfer process with substantial utility in energy applications. Boiling performance is described mainly by the heat‐transfer coefficient (HTC) and critical heat flux (CHF). Recent efforts for the simultaneous enhancement of HTC and CHF have been limited by an intrinsic trade‐off between them—HTC enhancement requires high nucleation‐site density, which can increase bubble coalescence resulting in limited CHF enhancement. In this work, this trade‐off is overcome by designing three‐tier hierarchical structures. The bubble coalescence is minimized to enhance the CHF by defining nucleation sites with microcavities interspersed within hemi‐wicking structures. Meanwhile, the reduced nucleation‐site density is compensated for by incorporating nanostructures that promote evaporation for HTC enhancement. The hierarchical structures demonstrate the simultaneous enhancement of HTC and CHF up to 389% and 138%, respectively, compared to a smooth surface. This extreme boiling performance can lead to significant energy savings in a variety of boiling applications.

36 MATERIALS SCIENCE↗

High flux boiling heat transfer enhancement using triangle shaped vertical walls in two-phase microchannel heat exchangers

Two-phase heat exchangers allow heat loads to be dissipated with lower fluid flow rates without inducing thermal gradients, and high surface area microchannels further reduce the thermal resistance of these heat exchangers. However, there are many practical limits that prevent widespread use of two-phase microchannel heat exchangers. Many authors have looked to address these practical limits by treating the channel floors or creating artificial nucleation sites. Few works look to enhance heat transfer in the walls of channels with hydraulic diameters below 200 μm. This work is aimed at increasing the efficacy of high aspect ratio silicon microchannels that use R134a as the working fluid. The 125 parallel channels are 40 μm wide, 200 μm deep, and 2 mm long and contain a 15 μm wide, 150 μm long restriction at each inlet. The thermal resistance and dryout characteristics of traditional, plain-walled channels are compared to channels with 2 area enhancement patterns each of which increases the area available for heat transfer by 41%. Furthermore, a resistance to dryout is seen in both area-enhanced test sections, and a 15.5% reduction in thermal resistance is shown for the area-enhanced part with a 6 μm triangular pitch. Only a 7.8% performance increase is seen in the test section with a 3 μm pitch. Both area enhancement patterns induce an average 27% increase in pressure drop for all tests. Heat transfer characteristics are solved for using a finite element analysis (FEA) model. By examining heat transfer coefficients and local heat fluxes, it is postulated that the area enhancement reduces heat transfer coefficients and the performance increase is caused by increasing the number of active nucleation sites.