Search NASA⌕ Search

SEARCH · Search NASA

Results for “occupancy modeling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

An Empirical Model For Intrinsic Alignments: Insights From Cosmological Simulations

We extend current models of the halo occupation distribution (HOD) to include a flexible, empirical framework for the forward modeling of the intrinsic alignment (IA) of galaxies. A primary goal of this work is to produce mock galaxy catalogs for the purpose of validating existing models and methods for the mitigation of IA in weak lensing measurements. This technique can also be used to produce new, simulation-based predictions for IA and galaxy clustering. Our model is probabilistically formulated, and rests upon the assumption that the orientations of galaxies exhibit a correlation with their host dark matter (sub)halo orientation or with their position within the halo. We examine the necessary components and phenomenology of such a model by considering the alignments between (sub)halos in a cosmological dark matter only simulation. We then validate this model for a realistic galaxy population in a set of simulations in the Illustris-TNG suite. We create an HOD mock with Illustris-like correlations using our method, constraining the associated IA model parameters, with the $\mathcal{X}$$^{2}_{dof}$ between our model’s correlations and those of Illustris matching as closely as 1.4 and 1.1 for orientation–position and orientation–orientation correlation functions, respectively. By modeling the misalignment between galaxies and their host halo, we show that the 3-dimensional two-point position and orientation correlation functions of simulated (sub)halos and galaxies can be accurately reproduced from quasi-linear scales down to 0.1 $\mathcal{h}$ –1 Mpc. We also find evidence for environmental influence on IA within a halo. Our publicly-available software provides a key component enabling efficient determination of Bayesian posteriors on IA model parameters using observational measurements of galaxy-orientation correlation functions in the highly nonlinear regime.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

EVOLUTION OF STELLAR-TO-HALO MASS RATIO AT z = 0–7 IDENTIFIED BY CLUSTERING ANALYSIS WITH THE HUBBLE LEGACY IMAGING AND EARLY SUBARU/HYPER SUPRIME-CAM SURVEY DATA

We present clustering analysis results from 10,381 Lyman break galaxies (LBGs) at z ∼ 4–7, identified in the Hubble legacy deep imaging and new complimentary large-area Subaru/Hyper Suprime-Cam data. We measure the angular correlation functions of these LBGs at z ∼ 4, 5, 6, and 7 and fit these measurements using halo occupation distribution (HOD) models that provide an estimate of halo masses, M{sub h}∼(1−20)×10{sup 11} M{sub ⊙}. Our M{sub h} estimates agree with those obtained by previous clustering studies in a UV-magnitude versus M{sub h} plane and allow us to calculate stellar-to-halo mass ratios (SHMRs) of LBGs. By comparison with the z∼0 SHMR, we identify evolution of the SHMR from z∼0 to z∼4 and from z∼4 to z∼7 at the >98% confidence levels. The SHMR decreases by a factor of ∼2 from z∼0 to 4 and increases by a factor of ∼4 from z∼4 to 7 at the dark matter halo mass of M{sub h}∼10{sup 11} M{sub ⊙}. We compare our SHMRs with results of a hydrodynamic simulation and a semianalytic model and find that these theoretical studies do not predict the SHMR increase from z∼4 to 7. We obtain the baryon conversion efficiency (BCE) of LBGs at z∼4 and find that the BCE increases with increasing dark matter halo mass. Finally, we compare our clustering+HOD estimates with results from abundance matching techniques and conclude that the M{sub h} estimates of the clustering+HOD analyses agree with those of the simple abundance matching within a factor of 3, and that the agreement improves when using more sophisticated abundance matching techniques that include subhalos, incompleteness, and/or evolution in the star formation and stellar mass functions.

79 ASTRONOMY AND ASTROPHYSICS↗

The Spatial Clustering of ROSAT All-Sky Survey Active Galactic Nuclei. V. The Evolution of Broad-line AGN Clustering Properties in the Last 6 Gyr

This is the fifth paper in a series of investigations of the clustering properties of luminous, broad-emission-line active galactic nuclei (AGNs) identified in the ROSAT All-Sky Survey (RASS) and Sloan Digital Sky Survey (SDSS). In this work we measure the cross-correlation function (CCF) between RASS/SDSS Data Release 14 AGNs with the SDSS CMASS galaxy sample at 0.44 < z < 0.64. We apply halo occupation distribution (HOD) modeling to the CCF along with the autocorrelation function of the CMASS galaxies. We find that X-ray-selected and optically selected AGNs at 0.44 < z < 0.64 reside in statistically identical halos with a typical dark matter halo (DMH) mass of $M$$^{typ,AGN}_{DMH}$ ~ 10 12.7 h –1 M ⊙ . The acceptable HOD parameter space for these two broad-line AGN samples have only statistically marginal differences caused by small deviations of the CCFs in the one-halo-dominated regime on small scales. In contrast to optically selected AGNs, the X-ray AGN sample may contain a larger population of satellites at MDMH ~ 1013h–1M⊙. We compare our measurements in this work with our earlier studies at lower independent redshift ranges, spanning a lookback time of 6 Gyr. The comparison over this wider redshift range of 0.07 < z < 0.64 reveals (i) no significant difference between the typical DMH masses of X-ray-selected and optically selected AGNs, (ii) weak positive clustering dependencies of $M$$^{typ,AGN}_{DMH}$ with L X and M BH , (iii) no significant dependence of $M$$^{typ,AGN}_{DMH}$ on Eddington ratio, and (iv) the same DMH masses host more-massive accreting black holes at high redshift than at low redshifts.

79 ASTRONOMY AND ASTROPHYSICS↗

Development of a hardware-in-the-loop testbed for laboratory performance verification of flexible building equipment in typical commercial buildings

The goals of reducing energy costs, shifting electricity peaks, increasing the use of renewable energy, and enhancing the stability of the electric grid can be met in part by fully exploiting the energy flexibility potential of buildings and building equipment. The development of strategies that exploit these flexibilities could be facilitated by publicly available high-resolution datasets illustrating how control of HVAC systems in commercial buildings can be used in different climate zones to shape the energy use profile of a building for grid needs. This article presents the development and integration of a Hardware-In-the-Loop Flexible load Testbed (HILFT) that integrates physical HVAC systems with a simulated building model and simulated occupants with the goal of generating datasets to verify load flexibility of typical commercial buildings. Compared to simulation-only experiments, the hardware-in-the-loop approach captures the dynamics of the physical systems while also allowing efficient testing of various boundary conditions. The HILFT integration in this article is achieved through the co-simulation among various software environments including LabVIEW, MATLAB, and EnergyPlus. Although theoretically viable, such integration has encountered many real-world challenges, such as: 1) how to design the overall data infrastructure to ensure effective, robust, and efficient integration; 2) how to avoid closed-loop hunting between simulated and emulated variables; 3) how to quantify system response times and minimize system delays; and 4) how to assess the overall integration quality. Lessons-learned using the examples of an AHU-VAV system, an air-source heat pump system, and a water-source heat pump system are presented.

Chen, zhelun↗

Numerical Investigation of Occupant Injury Risks During A Realistic Transport Aircraft Crash Conditions

Researchers at the National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC) have conducted a full-scale crash test of a Fokker F28 MK1000 aircraft to investigate the performance of transport aircraft under realistic crash conditions. This crash test was computationally recreated using finite element (FE) human body models (HBMs) to further explore potential injury risks to occupants and analyze the utilization of HBMs in the aerospace crash environment. The Global Human Body Model Consortium (GHBMC) male 50th percentile occupant detailed model (v6.0) and the Toyota Human Model for Safety (THUMS) male 50th percentile occupant model (v6.1) were selected to be used in the crash simulations. The HBMs were simulated in conditions matching those of anthropomorphic test device (ATD) experiments included within the aircraft cabin during the crash test. Seven occupant locations within the cabin were simulated utilizing each of the models. The models were positioned in a neutral upright posture with hands resting on the legs and the feet contacting the floor. Head, brain, neck, and lumbar vertebra injury metrics were calculated for all trials. Both HBM models required minor modifications to stabilize these simulations. The GHBMC model required added erosion for six parts while the THUMS model only required one in order to complete the full simulation. The THUMS model, however, required a much smaller timestep for stability and therefore took significantly more computational time. In addition the GHBMC model includes integrated instrumentation while the THUMS model requires development and implementation of instrumentation. Both models predicted 100% injury risk for lumbar vertebra fracture in all test conditions. This prediction was in family with high lumbar load values measured by the ATDs during the crash test. The THUMS model consistently predicted lower injury risks than the GHBMC model in all three other metrics varying depending on the crash pulse. Overall, the THUMS model required less modifications to allow for this study. However, the GHBMC models significantly faster run time and integrated instrumentation make it a more intuitive model for this research.

Crashworthiness↗

Addressing APC Data Sparsity in Predicting Occupancy and Delay of Transit Buses: A Multitask Learning Approach

Public transit is a vital mode of transportation in urban areas, and its efficiency is crucial for the daily commute of millions of people. To improve the reliability and predictability of transit systems, researchers have developed separate single-task learning models to predict the occupancy and delay of buses at the stop or route level. However, these models provide a narrow view of delay and occupancy at each stop and do not account for the correlation between the two. We propose a novel approach that leverages broader generalizable patterns governing delay and occupancy for improved prediction. We introduce a multitask learning toolchain that takes into account General Transit Feed Specification feeds, Automatic Passenger Counter data, and contextual temporal and spatial information. The toolchain predicts transit delay and occupancy at the stop level, improving the accuracy of the predictions of these two features of a trip given sparse and noisy data. We also show that our toolchain can adapt to fewer samples of new transit data once it has been trained on previous routes/trips as compared to state-of-the-art methods. Finally, we use actual data from Chattanooga, Tennessee, to validate our approach. We compare our approach against the state-of-the-art methods and we show that treating occupancy and delay as related problems improves the accuracy of the predictions. We show that our approach improves delay prediction significantly by as much as 4% in F1 scores while producing equivalent or better results for occupancy.

Zulqarnain, Ammar Bin↗

Extended approximation for the lowest-lying states in odd-mass nuclei

An enhanced model, based on the extended boson approximation, for the lowest-lying states in odd-mass nuclei is presented. Our approach is built on the quasiparticle phonon model, extending it to take into account the ground-state correlations due to the action of the Pauli principle more accurately than in the conventional theory. The derived interaction strengths between the quasiparticles and the phonons in this model depend on the quasiparticle occupation numbers explicitly coupling the odd-mass nucleus equations with those of the even-even core. Within this model we calculated the transition probabilities in several Te, Xe, and Ba isotopes with A{approx_equal}130.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Smart building management vs. intuitive human control—Lessons learnt from an office building in Hungary

We report that smart building management and control are adopted nowadays to achieve zero-net energy use in buildings. However, without considering the human dimension, technologies alone do not necessarily guarantee high performance in buildings. An office building was designed and built according to state-of-the-art design and energy management principles in 2008. Despite the expectations of high performance, the owner was facing high utility bills and low user comfort in the building located in Budapest, Hungary. The objective of the project was to evaluate the energy performance and comfort indices of the building, to identify the causes of malfunction and to elaborate a comprehensive energy concept. Firstly, current building conditions and operation parameters were evaluated. Our investigation found that the state-of-the-art building management system was in good conditions but it was operated by building operators and occupants who are not aware of the building management practice. The energy consumption patterns of the building were simulated with energy modelling software. The baseline model was calibrated to annual measured energy consumption, using actual occupant behaviour and presence, based on results of self-reported surveys, occupancy sensors and fan-coil usage data. Realistic occupant behaviour models can capture diversity of occupant behaviour and better represent the real energy use of the building. This way our findings and the effect of our proposed improvements could be more reliable. As part of our final comprehensive energy concept, we proposed intervention measures that would increase indoor thermal comfort and decrease energy consumption of the building. A parametric study was carried out to evaluate and quantify energy, comfort and return on investment of each measure. It was found that in the best case the building could save 23% of annual energy use. Lastly, future work includes the follow-up of: occupant reactions to intervention measures, the realized energy savings, the measurement of occupant satisfaction and behavioural changes.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

OccuTherm: Occupant Thermal Comfort Inference using Body Shape Information

Thermal comfort is a decisive factor for the well-being, productivity, and overall satisfaction of commercial building occupants. Many commercial building automation systems either use a fixed zone-wide temperature set-point for all occupants or they rely on extensive sensor deployments with frequent online interaction with occupants. This results in inadequate comfort levels or significant training effort from users, respectively. However, the increasing ubiquity of cheap, depth-based occupancy tracking systems has enabled an improvement in inferential capabilities. We propose the novel system OccuTherm to model thermal comfort of occupants. We conducted a laboratory study with 77 participants to collect data for the implementation of a thermal comfort model that derives thermal comfort using the human body shape. Based on the comparison with model baselines and ablations, we show that our approach infers thermal comfort of individuals with 60 % accuracy when body shape information is taken into account; 6 % more than state-of-the-art approaches. We make our code, mobile app, datasets, and models freely available.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Energy Modeling Enhancements to Identify Least-Cost Pathways to Net-Zero Carbon Homes: Preprint

Residential grid-interactive efficient buildings (GEBs) can utilize high levels of energy efficiency and demand flexibility to deliver value to occupants, the grid, and society. However, without the ability to analyze, design, and optimize residential GEBs there is a risk that homes will not realize their full potential value as efficient and dynamic resources, which could ultimately lead to higher than necessary energy costs for U.S. households and lower realization of potential energy efficiency and demand flexibility benefits such as increased convenience/automation, thermal comfort, durability, indoor air quality, and resilience. In 2018, the National Renewable Energy Laboratory (NREL) Residential Modeling Team developed a vision for an open source Residential GEB Analytics Platform built within DOE's EnergyPlus and OpenStudio modeling environment that would enable the design and optimization of residential GEBs, including the identification of least-cost pathways to highly energy-efficient and energy-flexible homes (e.g., net zero carbon homes). We created a detailed workplan for the development of new and enhanced residential GEB component-level models for EnergyPlus and OpenStudio needed to progress toward the vision for the analytics platform while delivering near-term benefits to industry. This paper 1) presents the vision for the platform, summarizing the workplan for residential GEB modeling enhancements; 2) highlights significant advancements that have been achieved between 2018 and 2022, including stochastic residential occupancy modeling, flexible water heater modeling, detailed lithium-ion stationary battery modeling, and realistic residential HVAC modeling; and 3) outlines ongoing efforts and next steps toward the full vision for the platform.

building energy modeling↗

A Simulation Framework for Analyzing the Impact of Stochastic Occupant Behaviors on Demand Flexibility in Typical Commercial Buildings

As one of the primary users of the electric grid, buildings and building equipment, including heating, ventilation, and air conditioning (HVAC) systems, can be leveraged to provide the flexible demand needed to balance the grid. Typical strategies to achieve demand flexibility are to reduce electricity use during peak or critical periods by shutting down equipment or relaxing system setpoints, which will inevitably impact the occupants’ comfort. When occupants feel uncomfortable, they may take actions to regain their comfort, and some of those actions (such as turning on a personal fan) may have a negative impact on meeting the demand response goal. Therefore, it is important to incorporate occupant behaviors into the assessment ofthe building demand flexibility potential. In this study, a simulation framework that includes simulation of zone thermal loads, an HVAC system, and occupant behaviors, was developed to investigate the impact of occupant behaviors on demand flexibility. A case study was conducted using a small office model from the U.S. Department of Energy (DOE) Commercial Prototype Building Models to simulate the building envelope and zone loads. An agent-based occupant thermal behavior model was adapted to forecast occupants’ thermal comfort and their resulting thermal behaviors. An artificial neural network (ANN) based airflow model trained from a computational fluid dynamics (CFD) model of the zone was adopted to better predict the ambient environment of each occupant. An air-source heat pump simulation model that was calibrated from a real two-stage air-source heat pump system was used as the HVAC system. A typical load shedding event during peak hours was studied. Repeated simulations were conducted to capture the stochastic effects of occupant behaviors. The interplay between the demand flexibility, occupant comfort and behavior were analyzed by evaluating key performance indicators, including the energy use, occupant discomfort duration, and occupant behavior duration during the peak period. The results suggest that this framework can be used to analyze typical commercial buildings and their HVAC systems in terms ofdemand flexibility potential under the impact of occupant behaviors.

Chen, Zhelun↗

COSMOLOGICAL CONSTRAINTS FROM GALAXY CLUSTERING AND THE MASS-TO-NUMBER RATIO OF GALAXY CLUSTERS

We place constraints on the average density ({Omega}{sub m}) and clustering amplitude ({sigma}{sub 8}) of matter using a combination of two measurements from the Sloan Digital Sky Survey: the galaxy two-point correlation function, w{sub p} (r{sub p} ), and the mass-to-galaxy-number ratio within galaxy clusters, M/N, analogous to cluster M/L ratios. Our w{sub p} (r{sub p} ) measurements are obtained from DR7 while the sample of clusters is the maxBCG sample, with cluster masses derived from weak gravitational lensing. We construct nonlinear galaxy bias models using the Halo Occupation Distribution (HOD) to fit both w{sub p} (r{sub p} ) and M/N for different cosmological parameters. HOD models that match the same two-point clustering predict different numbers of galaxies in massive halos when {Omega}{sub m} or {sigma}{sub 8} is varied, thereby breaking the degeneracy between cosmology and bias. We demonstrate that this technique yields constraints that are consistent and competitive with current results from cluster abundance studies, without the use of abundance information. Using w{sub p} (r{sub p} ) and M/N alone, we find {Omega}{sup 0.5}{sub m}{sigma}{sub 8} = 0.465 {+-} 0.026, with individual constraints of {Omega}{sub m} = 0.29 {+-} 0.03 and {sigma}{sub 8} = 0.85 {+-} 0.06. Combined with current cosmic microwave background data, these constraints are {Omega}{sub m} = 0.290 {+-} 0.016 and {sigma}{sub 8} = 0.826 {+-} 0.020. All errors are 1{sigma}. The systematic uncertainties that the M/N technique are most sensitive to are the amplitude of the bias function of dark matter halos and the possibility of redshift evolution between the SDSS Main sample and the maxBCG cluster sample. Our derived constraints are insensitive to the current level of uncertainties in the halo mass function and in the mass-richness relation of clusters and its scatter, making the M/N technique complementary to cluster abundances as a method for constraining cosmology with future galaxy surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

Occupant Response Analysis of a Full-Scale Crash Test of a Fokker F28 Fellowship Aircraft

In this report, the capability of component fuselage testing and finite element models (FEMs) to predict occupant injury risk when applied to full-scale aircraft crash testing was evaluated. Component level and full-scale crash tests of a Fokker-F28 aircraft were performed in conjunction with representative FEM simulations. Lumbar spine injury risk, calculated through Anthropomorphic Test Device (ATD) outputs measured in the full-scale test, was compared with predictions made by component level testing and simulations. A quantitative assessment of FEM prediction accuracy was made using the International Organization for Standardization (ISO) Technical Report (TR) 16250 curve comparison methodology. Lumbar load injury risk measured in the full-scale test configuration was found to be significantly higher than in the component tests performed. The FEM provided a closer prediction of occupant injury risk than component testing but exhibited limitations in the multi-axis load environment. This work will help inform the application of component testing and FEM simulation when used to evaluate aircraft crashworthiness.

Jacob B Putnam↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

MODELING THE VERY SMALL SCALE CLUSTERING OF LUMINOUS RED GALAXIES

We model the small-scale clustering of luminous red galaxies (LRGs) in the Sloan Digital Sky Survey. Specifically, we use the halo occupation distribution formalism to model the projected two-point correlation function of LRGs on scales well within the sizes of their host halos (0.016 h {sup -1} Mpc <= r <= 0.42 h {sup -1} Mpc). We start by varying P(N|M), the probability distribution that a dark matter halo of mass M contains N LRGs, and assuming that the radial distribution of satellite LRGs within halos traces the Navarro-Frenk-White (NFW) dark matter density profile. We find that varying P(N|M) alone is not sufficient to match the small-scale data. We next allow the concentration of satellite LRG galaxies to differ from that of dark matter and find that this is also not sufficient. Finally, we relax the assumption of an NFW profile and allow the inner slope of the density profile to vary. We find that this model provides a good fit to the data and the resulting value of the slope is -2.17 +- 0.12. The radial density profile of satellite LRGs within halos is thus not compatible with that of the underlying dark matter, but rather is closer to an isothermal distribution.

79 ASTRONOMY AND ASTROPHYSICS↗

Lawrence Berkley National Laboratory Building 59

The building management system in Building 59 is monitoring and archiving building-level electricity usage, HVAC and lighting system states (e.g., setpoint, temperature, flow rate, pressure), indoor environmental conditions (air temperature, relative humidity, CO2), on-site weather (air temperature, relative humidity), and especially occupant counts as well as other metrics such as Wi-Fi signal. This dataset could support multiple use cases, such as model predictive control and occupant related demand management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗