Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Machine Straightness Error Measurement Based on Optical Fiber Fabry–Pérot Interferometer Monitoring Technique

Abstract In this research, we propose an Error Separation Technique (EST) based on optical fiber sensors for on-machine straightness error measurement. Two fiber optic Fabry–Pérot interferometers have been developed serving as two displacement sensors. The displacement distance is computed according to the reflected spectrum from interferometers, which can achieve a sub-micrometer resolution. The two-point method has been employed to separate the straightness error of the slides and the profile error of a fine-polished standard block. The spacing distance between two interferometers is determined by the diameter of optical fibers so that the EST's resolution has the potential to reach the sub-millimeter scale. In the experiment, the straightness error has been measured on a commercially available computer numerical control machine tool, and the measurement has been conducted on its x-axis. The spacing distance between two optical fiber sensors is 1.5 mm which equals the EST's resolution along the machine tool's x-axis. The separated profile error of the measured standard block is around 30 µm which has been verified by a high precision Coordinate Measurement Machine (CMM). The magnitude of the separated straightness error is around 40 µm. This technique is flexible and simple to be conducted, which can contribute to the micro-machine tool calibration and other straightness error applications.

Engineering↗

Portable fiber optic coupled Doppler interferometer system for detonation and shock wave diagnostics

Testing and analysis of shock wave characteristics such as detonators and ground shock propagation frequently require a method of measuring velocity and displacement of the surface of interest. One method of measurement is Doppler interferometry. The VISAR (Velocity Interferometer System for Any Reflector) uses Doppler interferometry and has gained wide acceptance as the preferred tool for shock measurement. An important asset of VISAR is that it measures velocity and displacement nonintrusively.

Fleming, Kevin J.↗

Interferometer Control of Optical Tweezers

This paper discusses progress in using spatial light modulators and interferometry to control the beam profile of an optical tweezers. The approach being developed is to use a spatial light modulator (SLM) to control the phase profile of the tweezers beam and to use a combination of the SLM and interferometry to control the intensity profile. The objective is to perform fine and calculable control of the moments and forces on a tip or tool to be used to manipulate and interrogate nanostructures. The performance of the SLM in generating multiple and independently controllable tweezers beams is also reported. Concurrent supporting research projects are mentioned and include tweezers beam scattering and neural-net processing of the interference patterns for control of the tweezers beams.

Decker, Arthur J.↗

Three-Axis Attitude Estimation With a High-Bandwidth Angular Rate Sensor

A continuing challenge for modern instrument pointing control systems is to meet the increasingly stringent pointing performance requirements imposed by emerging advanced scientific, defense, and civilian payloads. Instruments such as adaptive optics telescopes, space interferometers, and optical communications make unprecedented demands on precision pointing capabilities. A cost-effective method was developed for increasing the pointing performance for this class of NASA applications. The solution was to develop an attitude estimator that fuses star tracker and gyro measurements with a high-bandwidth angular rotation sensor (ARS). An ARS is a rate sensor whose bandwidth extends well beyond that of the gyro, typically up to 1,000 Hz or higher. The most promising ARS sensor technology is based on a magnetohydrodynamic concept, and has recently become available commercially. The key idea is that the sensor fusion of the star tracker, gyro, and ARS provides a high-bandwidth attitude estimate suitable for supporting pointing control with a fast-steering mirror or other type of tip/tilt correction for increased performance. The ARS is relatively inexpensive and can be bolted directly next to the gyro and star tracker on the spacecraft bus. The high-bandwidth attitude estimator fuses an ARS sensor with a standard three-axis suite comprised of a gyro and star tracker. The estimation architecture is based on a dual-complementary filter (DCF) structure. The DCF takes a frequency- weighted combination of the sensors such that each sensor is most heavily weighted in a frequency region where it has the lowest noise. An important property of the DCF is that it avoids the need to model disturbance torques in the filter mechanization. This is important because the disturbance torques are generally not known in applications. This property represents an advantage over the prior art because it overcomes a weakness of the Kalman filter that arises when fusing more than one rate measurement. An additional advantage over prior art is that, computationally, the DCF requires significantly fewer real-time calculations than a Kalman filter formulation. There are essentially two reasons for this: the DCF state is not augmented with angular rate, and measurement updates occur at the slower gyro rate instead of the faster ARS sampling rate. Finally, the DCF has a simple and compelling architecture. The DCF is exactly equivalent to flying two identical attitude observers, one at low rate and one at high rate. These attitude observers are exactly of the form currently flown on typical three-axis spacecraft.

Bayard, David S.↗

On-chip Optical Filters with Designable Characteristics Based on an Interferometer with Embedded Silicon Photonic Structures

We demonstrate chip-scale flat-top filters at near-IR wavelengths using negative index photonic crystal based Mach-Zehnder interferometers. Supported by full three-dimensional numerical simulations, we experimentally demonstrate a new approach for engineering high-pass, low-pass, bandpass, and band-reject filters, based on designing the photonic band diagram both within the bandgap frequency region and away from it. We further show that our approach can be used to design filters that have tunable multilevel response for different sections of the spectrum and for different polarizations. This configuration enables deterministic control of the bandwidth and the rejection ratio of filters for integrated photonic circuits.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Jones's matrix representation of optical instruments. II - Fourier interferometers /spectrometers and spectropolarimeters/.

Our method of matrix synthesis of optical components and instruments is applied to the derivation of Jones's matrices appropriate for Fourier interferometers (spectrometers and spectropolarimeters). These matrices are obtained for both the source beam and the detector beam. In the course of synthesis, Jones's matrices of the various reflectors (plane mirrors; retroreflectors: roofed mirror, trihedral and prism cube corner, cat's eye) used by these interferometers are also obtained.

Fymat, A. L.↗

Wide angle Michelson Doppler imaging interferometer

The optical system, stepping control, phase and modulation depth, array detector, and directions sensor are described for a specialized type of Michelson interferometer which works at sufficiently high resolution to measure the line widths and Doppler shifts of naturally occurring atmospheric emissions. With its imaging capability, the instrument can potentially supply this data independently for each element of the 100 x 100 detector array. The experiment seeks: (1) to obtain vertical profiles of atmospheric winds and temperatures as functions of latitude by observing near the limb; (2) to acquire exploratory wind and temperature data on smaller scale structures in airglow irregularities and in auroral forms; and (3) to collaborate with other Spacelab experiments, such as barium cloud releases, in providing wind and temperature data.

Shepherd, G. G.↗

Modular removable precision mechanism for alignment of an FUV spatial heterodyne interferometer

Spaceflight optical instruments have two conflicting requirements. They need to be both rigid and lightweight. In addition, for interferometric far ultraviolet spectrometers, the requirements for precision positioning are more severe than for conventional spectrometers. To meet the challenge of lightweight optical instruments, a modular adjustment mechanism was developed to position two orthogonal axes of a universal three-axis gimbal support system with a positioning accuracy on the order of 10 arc seconds. The mechanism was designed as a self-contained assembly which can be removed after final alignment of a spacebound optical instrument to reduce its in-flight mass. To demonstrate the concept, a number of these assemblies were made and mounted on two of the positioning axes of a far ultraviolet spatial heterodyne interferometer. A shaft clamp was used on each positioning axis to retain the adjusted position. This paper describes the design of the mechanism and presents optical test results.

Tom, James L.↗

Optical fiber waveguide sagnac interferometer. Phase 1: Multiturn one meter diameter, single mode

A rotating ring interferometer was constructed using a 100 meters of single mode optical fiber wound on a crystal cylinder. A 20 inch diameter fiber interferometer gyroscope was built and its sensitivity was evaluated. Major noise sources were identified and improvements for the next phase of development were determined. The accuracy of .01 of a fringe can be improved to .0001 by the removal of the noise source.

Vali, V.↗

Interferometer for Measuring Acoustic Signals

Optical-fiber interferometer measures wave amplitude without contacting specimen surface. System contains remote detector head. Head includes beam splitter that divides input beam and recombines output beams, while spatial filter filters interference pattern at beam-splitter output; and lens focuses this on detector. Beams focused on specimen surface to record acoustic signals.

Claus, R. O.↗