Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

On the Alignment and Focusing of the Marshall Grazing Incidence X-ray Spectrometer (MaGIXS)

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a NASA sounding rocket instrument that is designed to observe soft X-ray emissions from 24 - 6.0 A (0.5 - 2.0 keV energies) in the solar atmosphere. For the rst time, high-temperature, low-emission plasma will be observed directly with 5 arcsecond spatial resolution and 22 mA spectral resolution. The unique optical design consists of a Wolter - I telescope and a 3-optic grazing- incidence spectrometer. The spectrometer utilizes a nite conjugate mirror pair and a blazed planar, varied line spaced grating, which is directly printed on a silicon substrate using e-beam lithography. The grating design is being nalized and the grating will be fabricated by the Massachusetts Institute of Technology (MIT) and Izentis LLC. Marshall Space Flight Center (MSFC) is producing the nickel replicated telescope and spectrometer mirrors using the same facilities and techniques as those developed for the ART-XC and FOXSI mirrors. The Smithsonian Astrophysical Observatory (SAO) will mount and align the optical sub-assemblies based on previous experience with similar instruments, such as the Hinode X-Ray Telescope (XRT). The telescope and spectrometer assembly will be aligned in visible light through the implementation of a theodolite and reference mirrors, in addition to the centroid detector assembly (CDA) { a device designed to align the AXAF-I nested mirrors. Focusing of the telescope and spectrometer will be achieved using the X-ray source in the Stray Light Facility (SLF) at MSFC. We present results from an alignment sensitivity analysis performed on the on the system and we also discuss the method for aligning and focusing MaGIXS.

solar↗

Optical grating analyzer studies

A spectrometer was specifically designed and developed to observe grating spectra over a range of incidence angles from normal to almost grazing incidence. A unique scanning and focusing mechanism is utilized to keep the exit slit on the Rowland circle. Polarization effects in the vacuum were investigated, and efficiency measurements and spectral scans were made simultaneously with the spectrometer. Results of measurements are given. Applications of the spectrometer to the space program and to the study of contamination on optical surfaces are indicated.

Mcdonald, J. K.↗

AVIRIS foreoptics, fiber optics and on-board calibrator

The foreoptics, fiber optic system and calibration source of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are described. The foreoptics, based on a modified Kennedy scanner, is coupled by optical fibers to the four spectrometers. The optical fibers allow convenient positioning of the spectrometers in the limited space and enable simple compensation of the scanner's thermal defocus (at the -23 C operating temp) by active control of the fiber focal plane position. A challenging requirement for the fiber optic system was the transmission to the spectral range 1.85 to 2.45 microns at .45 numerical aperture. This was solved with custom fluoride glass fibers from Verre Fluore. The onboard calibration source is also coupled to the spectrometers by the fibers and provides two radiometric levels and a reference spectrum to check the spectrometers' alignment. Results of the performance of the assembled subsystems are presented.

Chrisp, Michael P.↗

AVIRIS foreoptics, fiber optics and on-board calibrator

The foreoptics, fiber optic system and calibration source of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) are described. The foreoptics, based on a modified Kennedy scanner, is coupled by optical fibers to the four spectrometers. The optical fibers allow convenient positioning of the spectrometers in the limited space and enable simple compensation of the scanner's thermal defocus (at the -23 C operating temp) by active control of the fiber focal plane position. A challenging requirement for the fiber optic system was the transmission to the spectral range 1.85 to 2.45 microns at .45 numerical aperture. This was solved with custom fluoride glass fibers from Verre Fluore. The onboard calibration source is also coupled to the spectrometers by the fibers and provides two radiometric levels and a reference spectrum to check the spectrometers' alignment. Results of the performance of the assembled subsystems are presented.

Chrisp, M. P.↗

Application of Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) to Determination of Atmospheric Aerosol Optical Depth and Precipitable Water Content

This paper focuses on determination of the temporal and spatial gas absorption and aerosol scattering properties of the atmosphere itself including the radiative properties of clouds, specifically derivation of estimates of aerosol optical depth, atmospheric water vapor, and oxygen pressure surface altitude form upwelling near-TOA spectral radiance measurements obtained with the AVIRIS.

Remote SensingAVIRIS↗

Superfluid-Tight Cryogenic Receiver With Continuous Sub-Kelvin Cooling for EXCLAIM

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne telescope designed to survey star formation over cosmological time scales using intensity mapping in the 420 – 540 GHz frequency range. EXCLAIM uses a fully cryogenic telescope coupled to six on-chip spectrometers featuring kinetic inductance detectors (KIDs) to achieve high sensitivity, allowing for fast integration in dark atmospheric windows. The telescope receiver is cooled to ≈ 1.7 K by immersion in a superfluid helium bath and enclosed in a superfluid-tight shell with a meta-material anti-reflection coated silicon window. In addition to the optics and the spectrometer package, the receiver contains the magnetic shielding, the cryogenic segment of the spectrometer readout, and the sub-Kelvin cooling system. A three-stage continuous adiabatic demagnetization refrigerator (CADR) keeps the detectors at 100 mK while a 4He sorption cooler provides a 900 mK thermal intercept for mechanical suspensions and coaxial cables. We present the design of the EXCLAIM receiver and report on the flight-like testing of major receiver components, including the superfluid-tight receiver window and the sub-Kelvin coolers.

continuous adiabatic demagnetization refrigerator↗

Comparison of two droplet sizing systems in an icing wind tunnel

A comparison between the Phase Doppler Analyzer and the combined measurements from the Particle Measuring Systems Forward Scattering Spectrometer Probe and the Optical Array Probe was conducted in an icing wind tunnel using NASA Icing Research Tunnel spray nozzles to produce the icing cloud. Clouds with a range of volume median diameters from 10 to greater than 50 microns were used for the instrument comparisons. A comparison of the volume median diameter from the Phase Doppler Particle Analyzer and only the Forward Scattering Spectrometer Probe indicated agreement up to 18 microns. A combined volume median diameter was calculated from the droplet distribution of the Optical Array Probe and the Forward Scattering Spectrometer Probe. A comparison of the combined volume median diameters and the Phase Doppler Particle Analyzer volume median diameters showed agreement up to 30 microns with the agreement deteriorating rapidly above 30 microns. Droplet distributions from the Phase Doppler Particle Analyzer, the Forward Scattering Spectrometer Probe, and Optical Array Probe are presented.

Oldenburg, J. R.↗

Comparison of two droplet sizing systems in an icing wind tunnel

A comparison between the Phase Doppler Analyzer and the combined measurements from the Particle Measuring Systems Forward Scattering Spectrometer Probe and the Optical Array Probe was conducted in an icing wind tunnel using NASA Icing Research Tunnel spray nozzles to produce the icing cloud. Clouds with a range of volume median diameterss from 10 to greater than 50 microns were used for the instrument comparisons. A comparison of the volume median diameter from the Phase Doppler Particle Analyzer and only the Forward Scattering Spectrometer Probe indicated agreement up to 18 microns. A combined volume median diameter was calculated from the droplet distribution of the Optical Array Probe and the Forward Scattering Spectrometer Probe. A comparison of the combined volume median diameters and the Phase Doppler Particle Analyzer volume median diameters showed agreement up to 30 microns with the agreement deteriorating rapidly above 30 microns. Droplet distributions from the Phase Doppler Particle Analyzer, the Forward Scattering Spectrometer Probe, and Optical Array Probe are presented.

Oldenburg, John R.↗

Telescope-optical system performance analysis for the Cryogenic Limb Array Etalon Spectrometer (CLAES) on the Upper Atmospheric Research Satellite

A first-order performance analysis of the CLAES telescope-optical system is presented. The experiment involves the passive measurement of earth-limb radiance over a 10-60 km tangent altitude range, and is based on a solid Fabry-Perot spectrometer which provides spectral resolution of 0.25/cm for atmospheric emission spectroscopy over the 3.5-12 micron IR range. The optical system is required to provide a high degree of off-axis rejection and stray-light control, primarily to suppress intense emission from the earth surface. The astigmatism and other geometric aberrations are corrected by a secondary mirror which produces an excellent image of the primary one, allowing for location of a diffraction control or Lyot stop. The off-axis scattering performance of the telescope is examined in terms of the mirror scatter coefficient and point source rejection ratio. A mirror bidirectional reflectance distribution function of 0.0001 at 1 deg with a 1/theta-squared roll-off between 1 and 0.2 deg is realizable based on recent measurements. This results in an off-axis radiance term that is generally small in comparison with the system-limiting NER.

Roche, A. E.↗

Multiple-Path-Length Optical Absorbance Cell

An optical absorbance cell that offers a selection of multiple optical path lengths has been developed as part of a portable spectrometric instrument that measures absorption spectra of small samples of water and that costs less than does a conventional, non-portable laboratory spectrometer. The instrument is intended, more specifically, for use in studying colored dissolved organic matter (CDOM) in seawater, especially in coastal regions. Accurate characterization of CDOM is necessary for building bio-optical mathematical models of seawater. The multiple path lengths of the absorption cell afford a wide range of sensitivity needed for measuring the optical absorbances associated with the wide range of concentrations of CDOM observed in nature. The instrument operates in the wavelength range of 370 to 725 nm. The major subsystems of the instrument (see figure) include a color-balanced light source; the absorption cell; a peristaltic pump; a high-precision, low-noise fiber optic spectrometer; and a laptop or other personal computer. A fiber-optic cable transmits light from the source to the absorption cell. Other optical fibers transmit light from the absorption cell to the spectrometer,

Source record↗

A transmitted-beam diagnostic for the wavelength-tunable UV drive beam on OMEGA

A transmitted-beam diagnostic (P9TBD) was developed as part of a new experimental platform used to study laser–plasma interactions on OMEGA. Located in the opposing port to the wavelength-tunable (350 nm to 353 nm) UV drive beam, the P9TBD characterizes the beam after it propagates through an undersense plasma. The instrument consists of a large-aperture window that allows light to exit the target chamber and project onto a thin sheet of semi-transparent diffuser material. Light transmitted through the diffuser is recorded using a time-integrated camera and a fiber-optically coupled streaked spectrometer, providing measurements of the energy, power, fluence, polarization, and spectrum of the transmitted beam. Here, the diagnostic enables direct observation of a variety of cross-beam energy transfer phenomena, such as wavelength detuning, polarization effects, and gain saturation.

47 OTHER INSTRUMENTATION↗

Current instrument status of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS)

An upgraded version of AVIRIS, an airborne imaging spectrometer based on a whiskbroom-type scanner coupled via optical fibers to four dispersive spectrometers, that has been in operation since 1987 is described. Emphasis is placed on specific AVIRIS subsystems including foreoptics, fiber optics, and an in-flight reference source; spectrometers and detector dewars; a scan drive mechanism; a signal chain; digital electronics; a tape recorder; calibration systems; and ground support requirements.

Eastwood, Michael L.↗

Space Shuttle Main Engine nozzle mounted optic for throat plane spectroscopy

A program intended to develop a flight-capable nozzle mounted optic for monitoring emissions from metals entrained in the Space Shuttle Main Engine (SSME) flowfield is described. The optic will collect light emitted from metal atoms within the high-temperature, high-pressure SSME chamber and transfer the optical signal to a high-resolution spectrometer via a fiber-optic cable. The nozzle mounted optic makes it possible to conduct earth-to-orbit monitoring of flowfield emissions without requiring modifications to the SSME.

Bickford, R. L.↗

All-aluminum optical system for a large cryogenically cooled far infrared echelle spectrometer

In the past few years, NASA's Kuiper Airborne Observatory (KAO) has made it possible to conduct pioneering observations of far infrared lines from astronomical sources. Such observations, in the case of wavelengths in the approximate range from 20 to 350 microns, cannot be performed from ground-based sites, because of telluric water absorption effects. Lines in the considered range provide information about the interstellar gas in molecular, neutral atomic, and ionized form of occurrence. The present paper provides a description of the development of the cryogenic optical system of a spectrometer designed to exploit the potential of the KAO for observing the far infrared lines. Attention is given to design goals and considerations, details of optical design, the fabrication of the optical system, the cryostat, and performance.

Erickson, E. F.↗

Analysis of Hybrid Gas–Dust Outbursts Observed at 67P/Churyumov–Gerasimenko

Cometary outbursts offer a valuable window into the composition of comet nuclei with their forceful ejection of dust and volatiles in explosive events, revealing the interior components of the comet. Understanding how different types of outbursts influence the dust properties and volatile abundances, to better interpret what signatures can be attributed to primordial composition and what features are the result of processing, is an important task best undertaken with a multi-instrument approach. The European Space Agency Rosetta mission to 67P/Churyumov–Gerasimenko carried a suite of instruments capable of carrying out this task in the near-nucleus coma with unprecedented spatial and spectral resolution. In this work, we discuss two outbursts that occurred 2015 November 7 and were observed by three instruments on board: the Alice ultraviolet spectrograph, the Visual Infrared and Thermal Imaging Spectrometer, and the Optical, Spectroscopic, and Infrared Remote Imaging System. Together, the observations show that mixed gas and dust outbursts can have different spectral signatures representative of their initiating mechanisms, with the first outburst showing indicators of a cliff collapse origin and the second more representative of fresh volatiles being exposed via a deepening fracture. This analysis opens up the possibility of remote spectral classification of cometary outbursts with future work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Load dynamics of double planar foil liners and double planar wire arrays on the UM MAIZE LTD generator

In previous studies using the University of Nevada, Reno's (UNR's) high-impedance Zebra Marx generator (1.9 Ω, 1.7 MA, 100 ns), Double Planar Wire Arrays (DPWAs) proved to be excellent radiators, and Double Planar Foil Liners (DPFLs) proved useful for future inertial confinement fusion applications. This article presents the results of joint UNR/UM (University of Michigan) experiments with aluminum (Al) DPWAs, Al DPFLs, and tungsten (W) DPWAs using UM's Michigan Accelerator for Inductive Z-Pinch Experiments (MAIZE) generator, a low-impedance Linear Transformer Driver (LTD) (0.1 Ω, 0.5–1 MA, and 100–250 ns). The main goals of this study were twofold: the first was a pioneering effort to test whether a relatively heavy Al DPFL could successfully be imploded on a low-impedance university-scale LTD like the MAIZE generator, and, if so, to analyze the results and make comparisons to the optimized, lighter DPWA configurations that have been previously studied. The DPWAs consisted of two planes of micrometer-scale diameter Al or W wires, while the DPFLs consisted of two planes of micrometer-scale thickness Al foils. Diagnostics include filtered Si-diodes, an absolutely calibrated filtered PCD, x-ray pinhole cameras, spectrometers, and gated optical self-emission imaging. The implosion dynamics and radiative properties of Al DPWAs and DPFLs and W DPWAs on the MAIZE LTD are discussed and compared. Time-dependent load inductance calculations derived from measurements of the load current and a MAIZE circuit model provide a relative measurement of pinch strength. In experiments on MAIZE, W planar wire arrays exhibited a higher peak load inductance throughout the pinch than Al DPWAs and DPFLs, while x-ray pulses from Al DPFLs had the longest emission duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimization of Conditions for Photoluminescence-Based Sensing of Critical Minerals: Strategies and Outlook

Economically critical minerals and metals are vital to America’s security, with application areas in energy, advanced technologies, and defense systems. The growing implementation of renewable energy sources such as electric vehicles is expected to significantly increase demand for these minerals, while the global supply is monopolistic, with most of the production occurring in a few countries outside of the US. To mitigate potential supply chain vulnerabilities, the domestic production of economically critical metals has become a bipartisan priority of the US government, and unconventional sources such as coal and its utilization byproducts such as fly ash and acid mine drainage are being actively explored as an alternative method for meeting domestic demand. Slow and expensive characterization methods for critical metals present a significant pain point for domestic production, which has led to the exploration of alternative low-cost, portable platforms capable of detecting target metals during resource prospecting and downstream process monitoring. The National Energy Technology Laboratory has developed a portable fiber optic-based luminescence spectrometer that utilizes a metal-organic framework (MOF) material to detect and distinguish parts-per-billion levels of the visible-emitting rare earth elements terbium, dysprosium, samarium, and europium, which are all economically critical metals. Although preliminary results with this system are promising, a crucial barrier to practical deployment is the ability to operate in low pH, high ionic strength environments, as acidic conditions and the presence of other metal ions can significantly reduce luminescence signal. Here, current strategies related to sample treatment, material design, and sensor configuration are discussed in the context of improving sensor performance in application-relevant conditions. Additionally, future opportunities, such as the optimization of the sensing binding environment through computational methods and specific metals to be removed for treatment will be discussed, presenting a forward-looking view for innovation in luminescent sensing of critical metals.

36 MATERIALS SCIENCE↗