Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical synchronization systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Synchroscan streak camera imaging at a 15-MeV photoinjector with emittance exchange

At the Fermilab A0 photoinjector facility, bunch-length measurements of the laser micropulse and the e-beam micropulse have been done in the past with a fast single-sweep module of the Hamamatsu C5680 streak camera with an intrinsic shot-to-shot trigger jitter of 10 to 20 ps. We have upgraded the camera system with the synchroscan module tuned to 81.25 MHz to provide synchronous summing capability with less than 1.5-ps FWHM trigger jitter and a phase-locked delay box to provide phase stability of {approx}1 ps over 10s of minutes. These steps allowed us to measure both the UV laser pulse train at 263 nm and the e-beam via optical transition radiation (OTR). Due to the low electron beam energies and OTR signals, we typically summed over 50 micropulses with 0.25-1 nC per micropulse. The phase-locked delay box allowed us to assess chromatic temporal effects and instigated another upgrade to an all-mirror input optics barrel. In addition, we added a slow sweep horizontal deflection plug-in unit to provide dual-sweep capability for the streak camera. We report on a series of measurements made during the commissioning of these upgrades including bunch-length and phase effects using the emittance exchange beamline and simultaneous imaging of a UV drive laser component, OTR, and the 800-nm diagnostics laser.

43 PARTICLE ACCELERATORS↗

Multiple wavelength geodesy

An apparatus is being constructed which should be able to measure baselines up to 50 km long with a fractional uncertainty of about 5 x 10 to the -8 power. The instrument will measure both the optical length and the required correction due to the refractivity of the atmosphere, using three wavelengths transmitted in one direction over the path to an active receiver. The three wavelengths are 632.8 nm, 441.6 nm and 3.7 cm. The two endpoint instruments are synchronized using subsidiary return transmissions at 632.8 nm and another telemetry signal. The one-way nature of the system allows an increase in range over existing round-trip systems.

Levine, J.↗

Comparison of on-shot, in-tank, and equivalent-target-plane measurements of the OMEGA Laser System focal spot

The newly developed full-beam-in-tank (FBIT) diagnostic has the capability to characterize multiple beamlines in the target chamber. In addition to measuring multiple beams, we can obtain measurements of the step-by-step changes to achieve smoothing by spectral dispersion (SSD), the SSD kernel, and SSD synchronization. Since other existing diagnostics are all located upstream of the target chamber, this diagnostic can be used to explore a propagating beam through the final optics assembly. In this work, we investigate current discrepancies between laser diagnostics and experimental results by comparing results of on-shot direct measurements using FBIT and the equivalent-target-plane diagnostic.

47 OTHER INSTRUMENTATION↗

Resonant propagation of extreme-ultraviolet pulses through strongly driven high-density media

We show that by combining strong-field dressing and resonant propagation of XUV pulses, the transition of absorption lines from their natural Lorentzian profiles through Fano and complex multipeak shapes all the way back to broadened near-Lorentzian profiles can be achieved, in the limit of optically thick samples. The final stage of this spectral modification can be understood in terms of a significant temporal stretching and delay of the resonant XUV pulse as it propagates through the dense gas, which alters the ultrafast absorption that is modified by the time-synchronized few-femtosecond laser pulse. We first demonstrate this concept in numerical calculations, both using a model system and through a fully coupled solution of the time-dependent Schrödinger equation and the Maxwell wave equation. The applicability and generality of the underlying mechanism is then illustrated in proof-of-principle attosecond transient absorption measurements in a helium gas with a widely varying atomic density. These results provide insights into the interaction of ultrashort laser pulses with dense media and its coherent control. Published by the American Physical Society 2025

He, Yu (ORCID:0000000152120176)↗

Real-time Optical Network for Accelerator Control

The timing requirements of a modern accelerator complex call for several features. The first is a system for high precision relative timing among accelerator components. Stabilized fiber links have already been demonstrated to achieve sub-10 femtoseconds relative timing precision. The second is a system for timing distribution of absolute time with sufficient precision to identify a specific RF bucket. The White Rabbit technology is a promising candidate to deliver the absolute time that is linked to the GPS clock. In this study we demonstrated that these two technologies can be combined in a way that the absolute time information can be delivered to the stabilized fiber link system. This was accomplished by researching the design of the stabilized fiber and White Rabbit systems and devising adaptation modules that facilitate co-existence of both systems in the same FPGA environment. We built a prototype system using off-the-shelf products and implemented a proof-of-concept version of the FPGA firmware. The test verified that the White Rabbit features operate correctly under the stabilized fiber system environment. This work demonstrates that turn-key femtosecond timing systems with absolute time information can be built cost effectively and deployed in various accelerator environments. This will lead to many new applications in chemistry, biology and surface dynamics, to name a few.

43 PARTICLE ACCELERATORS↗

Single-mode fiber systems for deep space communication network

The present investigation is concerned with the development of single-mode optical fiber distribution systems. It is pointed out that single-mode fibers represent potentially a superior medium for the distribution of frequency and timing reference signals and wideband (400 MHz) IF signals. In this connection, single-mode fibers have the potential to improve the capability and precision of NASA's Deep Space Network (DSN). Attention is given to problems related to precise time synchronization throughout the DSN, questions regarding the selection of a transmission medium, and the function of the distribution systems, taking into account specific improvements possible by an employment of single-mode fibers.

Lutes, G.↗

A New Comprehensive Lightning Instrumentation System for Pad 39B at the Kennedy Space Center, Florida

A new comprehensive lightning instrumentation system has been designed for Launch Complex 39B at the Kennedy Space Center, Florida. This new instrumentation system includes the synchronized recording of six high-speed video cameras, currents through the nine downconductors of the new lightning protection system, four B-dot, 3-axis measurement stations, and five D-dot stations composed of two antennas each. The instrumentation system is composed of centralized transient recorders and digitizers that located close to the sensors in the field. The sensors and transient recorders communicate via optical fiber. The transient recorders are triggered by the B-dot sensors, the E-dot sensors, or the current through the downlead conductors. The high-speed cameras are triggered by the transient recorders when the latter perceives a qualified trigger.

Mata, Carlos T.↗

Characterization of transverse electron pulse trains using RF powered traveling wave metallic comb striplines

Advancements in ultrafast electron microscopy have allowed elucidation of spatially selective structural dynamics. However, as the spatial resolution and imaging capabilities have made progress, quantitative characterization of the electron pulse trains has not been reported at the same rate. In fact, inexperienced users have difficulty replicating the technique because only a few dedicated microscopes have been characterized thoroughly. Systems replacing laser driven photoexcitation with electrically driven deflectors especially suffer from a lack of quantified characterization because of the limited quantity. The primary advantages to electrically driven systems are broader frequency ranges, ease of use and simple synchronization to electrical pumping. Here, we characterize the technical parameters for electrically driven UEM including the shape, size and duration of the electron pulses using low and high frequency chopping methods. At high frequencies, pulses are generated by sweeping the electron beam across a chopping aperture. For low frequencies, the beam is continuously forced off the optic axis by a DC potential, then momentarily aligned by a countering pulse. Using both methods, we present examples that measure probe durations of 2 ns and 10 ps for the low and high frequency techniques, respectively. Here, we also discuss how the implementation of a pulsed probe affects STEM imaging conditions by adjusting the first condenser lens.

36 MATERIALS SCIENCE↗

SU-F-T-287: A Preliminary Study On Patient Specific VMAT Verification Using a Phosphor-Screen Based Geometric QA System (Raven QA)

Purpose: The RavenQA system (LAP Laser, Germany) is a QA device with a phosphor screen detector for performing the QA tasks of TG-142. This study tested if it is feasible to use the system for the patient specific QA of the Volumetric Modulated Arc Therapy (VMAT). Methods: Water equivalent material (5cm) is attached to the front of the detector plate of the RavenQA for dosimetry purpose. Then the plate is attached to the gantry to synchronize the movement between the detector and the gantry. Since the detector moves together with gantry, The ’Reset gantry to 0’ function of the Eclipse planning system (Varian, CA) is used to simulate the measurement situation when calculating dose of the detector plate. The same gantry setup is used when delivering the treatment beam for feasibility test purposes. Cumulative dose is acquired for each arc. The optical scatter component of each captured image from the CCD camera is corrected by deconvolving the 2D spatial invariant optical scatter kernel (OSK). We assume that the OSK is a 2D isotropic point spread function with inverse-squared decrease as a function of radius from the center. Results: Three cases of VMAT plans including head & neck, whole pelvis and abdomen-pelvis are tested. Setup time for measurements was less than 5 minutes. Passing rates of absolute gamma were 99.3, 98.2, 95.9 respectively for 3%/3mm criteria and 96.2, 97.1, 86.4 for 2%/2mm criteria. The abdomen-pelvis field has long treatment fields, 37cm, which are longer than the detector plate (25cm). This plan showed relatively lower passing rate than other plans. Conclusion: An algorithm for IMRT/VMAT verification using the RavenQA has been developed and tested. The model of spatially invariant OSK works well for deconvolution purpose. It is proved that the RavenQA can be used for the patient specific verification of VMAT. This work is funded in part by a Maryland Industrial Partnership Program grant to University of Maryland and to JPLC who owns the Raven technology. John Wong is a co-founder of JPLC.

60 APPLIED LIFE SCIENCES↗

Mechanism Design and Testing of a Self-Deploying Structure Using Flexible Composite Tape Springs

The detailed mechanical design of a novel deployable support structure that positions and tensions a membrane optic for space imagining applications is presented. This is a complex three-dimensional deployment using freely deploying rollable composite tape spring booms that become load bearing structural members at full deployment. The deployment tests successfully demonstrate a new architecture based on rolled and freely deployed composite tape spring members that achieve simultaneous deployment without mechanical synchronization. Proper design of the flexible component mounting interface and constraint systems, which were critical in achieving a functioning unit, are described. These flexible composite components have much potential for advancing the state of the art in deployable structures, but have yet to be widely adopted. This paper demonstrates the feasibility and advantages of implementing flexible composite components, including the design details on how to integrate with required traditional mechanisms.

Footdale, Joseph N.↗

Airborne Laser Polar Nephelometer

A polar nephelometer has been developed at NCAR to measure the angular variation of the intensity of light scattered by air molecules and particles. The system has been designed for airborne measurements using outside air ducted through a 5-cm diameter airflow tube; the sample volume is that which is common to the intersection of a collimated source beam and the detector field of view within the airflow tube. The source is a linearly polarized helium-neon laser beam. The optical system defines a collimated field-of-view (0.5deg half-angle) through a series of diaphragms located behind a I72-mm focal length objective lens. A photomultiplier tube is located immediately behind an aperture in the focal plane of the objective lens. The laser beam is mechanically chopped (on-off) at a rate of 5 Hz; a two-channel pulse counter, synchronized to the laser output, measures the photomultiplier pulse rate with the light beam both on and off. The difference in these measured pulse rates is directly proportional to the intensity of the scattered light from the volume common to the intersection of the laser beam and the detector field-of-view. Measurements can be made at scattering angles from 15deg to 165deg with reference to the direction of propagation of the light beam. Intermediate angles are obtained by selecting the angular increments desired between these extreme angles (any multiple of 0.1deg can be selected for the angular increment; 5deg is used in normal operation). Pulses provided by digital circuits control a stepping motor which sequentially rotates the detector by pre-selected angular increments. The synchronous photon-counting system automatically begins measurement of the scattered-light intensity immediately after the rotation to a new angle has been completed. The instrument has been flown on the NASA Convair 990 airborne laboratory to obtain data on the complex index of refraction of atmospheric aerosols. A particle impaction device is operated simultaneously to collect particles from the same airflow tube used to make the scattered-light measurements. A size distribution function is obtained by analysis of the particles collected by the impaction device. Calculated values of the angular variation of the scattered-light intensity are obtained by applying Mie scattering theory to the observed size distribution function and assuming different values of the complex index of refraction of the particles. The calculated values are then compared with data on the actual variation of the scattered-light intensity obtained with the polar nephelometer. The most probable value of the complex refractive index is that which provides the best fit between the experimental light scattering data and the parameters calculated from the observed size distribution function.

Grams, Gerald W.↗

FOCAL PLANE WAVEFRONT SENSING USING RESIDUAL ADAPTIVE OPTICS SPECKLES

Optical imperfections, misalignments, aberrations, and even dust can significantly limit sensitivity in high-contrast imaging systems such as coronagraphs. An upstream deformable mirror (DM) in the pupil can be used to correct or compensate for these flaws, either to enhance the Strehl ratio or suppress the residual coronagraphic halo. Measurement of the phase and amplitude of the starlight halo at the science camera is essential for determining the DM shape that compensates for any non-common-path (NCP) wavefront errors. Using DM displacement ripples to create a series of probe and anti-halo speckles in the focal plane has been proposed for space-based coronagraphs and successfully demonstrated in the lab. We present the theory and first on-sky demonstration of a technique to measure the complex halo using the rapidly changing residual atmospheric speckles at the 6.5 m MMT telescope using the Clio mid-IR camera. The AO system's wavefront sensor measurements are used to estimate the residual wavefront, allowing us to approximately compute the rapidly evolving phase and amplitude of speckle halo. When combined with relatively short, synchronized science camera images, the complex speckle estimates can be used to interferometrically analyze the images, leading to an estimate of the static diffraction halo with NCP effects included. In an operational system, this information could be collected continuously and used to iteratively correct quasi-static NCP errors or suppress imperfect coronagraphic halos.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of electrical discharges on Teflon dielectrics used as spacecraft thermal control

The dual effects of system degradation and reduced life of synchronous-orbit satellites as a result of differential spacecraft charging underscore the need for a clearer understanding of the prevailing electrical discharge phenomena. In a laboratory simulation, the electrical discharge current, surface voltage, emitted particle fluxes, and photo-emission associated with discharge events on electron beam irradiated silver-backed Teflon samples were measured. Sample surface damage was examined with optical and electron beam microscopes. The results are suggestive of a model in which the entire sample surface is discharged by lateral sub-surface currents flowing from a charge deposition layer through a localized discharge channel to the back surface of the sample. The associated return current pulse appears to have a duration which may be a signature by which different discharge processes may be characterized.

Yadlowsky, E. J.↗

Man-Computer Interactive Data Access System (McIDAS). Continued development of McIDAS and operation in the GARP Atlantic tropical experiment

The complete output of the Synchronous Meteorological Satellite was recorded on one inch magnetic tape. A quality control subsystem tests cloud track vectors against four sets of criteria: (1) rejection if best match occurs on correlation boundary; (2) rejection if major correlation peak is not distinct and significantly greater than secondary peak; (3) rejection if correlation is not persistent; and (4) rejection if acceleration is too great. A cloud height program determines cloud optical thickness from visible data and computer infrared emissivity. From infrared data and temperature profile, cloud height is determined. A functional description and electronic schematics of equipment are given.

Suomi, V. E.↗

Frequency non-degenerate sequential excitation of the impurity trapped exciton in strontium fluoride crystals doped with ytterbium

We model the dynamic behaviour observed for impurity-trapped excitons in SrF{sub 2}:Yb{sup 2+} using transient photoluminescence enhancement induced via a two-frequency, sequential excitation process employing an UV optical parametric amplifier synchronized to an IR free electron laser (FEL). We observe sharp transitions interpreted as a change of state of the localized hole and broad bands interpreted as a change of state of the delocalized electron. Our modeling indicates that the 4f crystal-field interaction is 25% smaller than in CaF{sub 2}. The photoluminescence enhancement transients are analyzed across a range of excitation frequencies using a system of rate equations. The temporal behavior is explained in terms of intra-excitonic relaxation, local lattice heating by the FEL, and liberation of electrons from trap states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Topology-Dependent Performance of Free-Space Photonic Quantum Networks Under Noise

Photonic quantum communication enables secure and high-fidelity information transfer beyond classical limits, with direct relevance to emerging quantum networks operating in free-space environments. While physical-layer models of depolarizing noise, Gamma–Gamma turbulence statistics, entanglement swapping, and decoy-state QKD security bounds are individually well established, prior work typically treats these components in isolation or under fixed network assumptions. In this work, we develop a unified topology-aware analytical framework that simultaneously integrates free-space optical link budgets, turbulence-induced visibility degradation, depolarizing qubit noise, multi-hop entanglement cascade dynamics, teleportation fidelity thresholds, CHSH nonlocality certification, and asymptotic decoy-state secret key rate bounds across star, mesh, and ring graph structures. Rather than introducing new physical channel models, we demonstrate that identical physical links exhibit fundamentally different end-to-end performance once embedded within different network topologies. Mesh architectures minimize visibility cascade through hop-count reduction but incur quadratic hardware scaling. Star topologies minimize link count but concentrate noise and synchronization overhead at the hub. Ring configurations offer linear hardware scaling with multiplicative fidelity degradation. The results establish topology as a first-order design parameter in near-term free-space quantum networks operating without full quantum repeater infrastructures. While motivated by distributed multi-agent architectures, the framework applies broadly to terrestrial, airborne, and satellite-assisted photonic quantum communication systems.

QKD↗

Synchronization effects on rest frame energy and momentum densities in the proton

We obtain two-dimensional relativistic densities and currents of energy and momentum in a proton at rest. These densities are obtained at surfaces of fixed light front time, which physically corresponds to using an alternative synchronization convention. Mathematically, this is done using tilted light front coordinates, which consist of light front time and ordinary spatial coordinates. In this coordinate system, all 16 components of the energy-momentum tensor (EMT) obtain clear physical interpretations, and the nine Galilean components reproduce results from standard light front coordinates. We find angular modulations in several densities that are absent in the corresponding instant form results, which are explained as optical effects arising from using fixed light front time when motion is present within the target. Additionally, transversely polarized spin-half targets exhibit an energy dipole moment—which evaluates to −1/4 for all targets if the Belinfante EMT is used, but which is target dependent and vanishes for pointlike fermions if the asymmetric EMT is instead used.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗