Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical systems design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 253 records · Page 14

Optimal Control for X-Ray Mircroscopes

In this article, a systematic framework for designing the control for fine positioning (scanning) stages of X-ray microscopes is presented. This framework facilitates designs that simultaneously achieve specifications on positioning resolution and tracking bandwidth while guaranteeing robustness of the closed loop device to unmodeled uncertainties. We use robust optimal control techniques for modeling, quantifying design objectives and system-specific challenges, and designing the control laws. The control designs were implemented on a three degree of freedom piezoactuated flexure stages dedicated for fine positioning of X-ray optics. Experimental results demonstrate significant improvements in positioning performance of 134%, 150%, and 132% in tracking bandwidths along the lateral (X), vertical (Y), and beam (Z) directions, respectively, when compared to proportional-integral-derivative controller designs. This was achieved while keeping similar or better positioning resolution and robustness measures. Fast scanning for X-ray imaging was demonstrated in both the step scan and flyscan modes, where bandwidth was improved by over 450 times with flyscan compared to the step scan.

42 ENGINEERING↗

MTW-OPAL: a technology development platform for ultra-intense optical parametric chirped-pulse amplification systems

Optical parametric chirped-pulse amplification implemented using multikilojoule Nd:glass pump lasers is a promising approach for producing ultra-intense pulses (>10 23 W/cm 2 ). We report on the MTW-OPAL Laser System, an optical parametric amplifier line (OPAL) pumped by the Nd:doped portion of the multi-terawatt (MTW) laser. This midscale prototype was designed to produce 0.5-PW pulses with technologies scalable to tens of petawatts. Technology choices made for MTW-OPAL were guided by the longer-term goal of two full-scale OPALs pumped by the OMEGA EP to produce 2 × 25-PW beams that would be co-located with kilojoule–nanosecond ultraviolet beams. Several MTW-OPAL campaigns that have been completed since “first light” in March 2020 show that the laser design is fundamentally sound, and optimization continues as we prepare for “first-focus” campaigns later this year.

42 ENGINEERING↗

A High-Field Polarized 3 He Target for Jefferson Lab’s CLAS12 Spectrometer

Polarized 3He nuclear targets are invaluable surrogates for polarized neutron targets in spin-dependent scattering studies of the structure of matter. Traditional polarized 3He targets have seen steady improvements and active use over the last three decades, however they have been limited to operation in low magnetic fields. This has precluded their use in spectrometers that utilize high-magnetic-field tracking systems, such as Jefferson Lab's CLAS12 spectrometer. Developments in high-magnetic-field metastability exchange optical pumping of 3He, recently incorporated into the design of a polarized 3He ion source for RHIC and the EIC, could enable a new, polarized 3He fixed target to operate within high fields. Combining high-field techniques with the double-cell cryogenic target design used for the MIT-Bates 88-02 experiment, polarization and target density comparable to traditional polarized 3He targets could be reached while within a high magnetic field environment. We discuss the conceptual design for such a target, show our progress in this target's development, and outline plans for in-beams tests in Jefferson Lab's Hall B.

Maxwell, James↗

Design Considerations to Ensure Robustness of the ITER Diagnostics Residual Gas Analyzer

Increasing robustness of the ITER diagnostic residual gas analyzer (DRGA) is critical for the potential control of plasma heating and fuel-cycle processing. Robustness is a requirement for a diagnostic to have a control function. The DRGA is a multisensor diagnostic system capable of resolving isotopic compositions of hydrogen and helium as well as other heavier elements and compounds. The divertor-specific DRGA system is intended to measure the composition of gases in the ITER subdivertor region and midplane. Its analysis station will be located in a port cell at the divertor level. From there, it will sample a slip stream of gas from the cryogenic pump duct. It will then exhaust into a shared roughing line where helium or other light gas impurities, some potentially from other diagnostic systems, are likely to be present. In order to provide reliable measurements, the DRGA must be robust in areas such as plasma optical emission source geometry for a compact design, mitigation of back-streaming from light gases and resilience to the ITER port cell environment, and radiation hardening of the DRGA electronics. By incorporating robustness into the design, areas of plasma heating and fuel-cycle control may be explored with the DRGA for ITER and next-generation fusion devices.

Quinlan, Brendan↗

Structural and Optical Properties of High Entropy (La,Lu,Y,Gd,Ce)AlO 3 Perovskite Thin Films

Mixtures of Ce-doped rare-earth aluminum perovskites are drawing a significant amount of attention as potential scintillating devices. However, the synthesis of complex perovskite systems leads to many challenges. Designing the A-site cations with an equiatomic ratio allows for the stabilization of a single-crystal phase driven by an entropic regime. This work describes the synthesis of a highly epitaxial thin film of configurationally disordered rare-earth aluminum perovskite oxide (La 0.2 Lu 0.2 Y 0.2 Gd 0.2 Ce 0.2 )AlO 3 and characterizes the structural and optical properties. The thin films exhibit three equivalent epitaxial domains having an orthorhombic structure resulting from monoclinic distortion of the perovskite cubic cell. An excitation of 286.5 nm from Gd 3+ and energy transfer to Ce 3+ with 405 nm emission are observed, which represents the potential for high-energy conversion. These experimental results also offer the pathway to tunable optical properties of high-entropy rare-earth epitaxial perovskite films for a range of applications.

36 MATERIALS SCIENCE↗

A Multiplexed Hybrid Velocimeter

Optical velocimetry systems play a crucial role in studying the dynamic behavior of materials under extreme conditions. Two prominent systems used at the Nevada National Security Site are the velocity interferometer system for any reflector(VISAR) and the photon Doppler velocimeter (PDV) system. Their ability to accurately measure surface motion ranging from 0 to > 20km=s without interacting with material flow enables experimenters to construct thermodynamic equations of state for materials of interest. A number of modifications to VISAR and PDV have taken place over the past five decades, leading to improved performance, increased recording capacity, and a reduction in operational burden. Prior efforts to develop a hybrid velocimeter combining the advantages of both PDV and VISAR into a single diagnostic did not take into account progress in PDV technology or new optical components that had not been developed. This thesis describes the design and implementation of a multiplexed hybrid velocimeter (MHV) based on time-multiplexing techniques, an optical hybrid, and polarization-maintaining fiber and components. Data from experiments, compared with current velocity systems, serve to demonstrate the hybrid's performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Self-Assembled TiN-Metal Nanocomposites Integrated on Flexible Mica Substrates towards Flexible Devices

The integration of nanocomposite thin films with combined multifunctionalities on flexible substrates is desired for flexible device design and applications. For example, combined plasmonic and magnetic properties could lead to unique optical switchable magnetic devices and sensors. In this work, a multiphase TiN-Au-Ni nanocomposite system with core–shell-like Au-Ni nanopillars embedded in a TiN matrix has been demonstrated on flexible mica substrates. The three-phase nanocomposite film has been compared with its single metal nanocomposite counterparts, i.e., TiN-Au and TiN-Ni. Magnetic measurement results suggest that both TiN-Au-Ni/mica and TiN-Ni/mica present room-temperature ferromagnetic property. Tunable plasmonic property has been achieved by varying the metallic component of the nanocomposite films. The cyclic bending test was performed to verify the property reliability of the flexible nanocomposite thin films upon bending. This work opens a new path for integrating complex nitride-based nanocomposite designs on mica towards multifunctional flexible nanodevice applications.

42 ENGINEERING↗

Bioexcitons by Design: How Do We Get There?

Biological pigment-protein complexes (PPCs) exhibit a remarkable ability to tune the optical properties of biological excitons (bioexcitons) through specific pigment-protein interactions. While such fine-tuning allows natural systems (e.g., photosynthetic proteins) to carry out their native functions with near-optimal performance, native function itself is often suboptimal for applications such as biofuel production or quantum technology development. Furthermore, this perspective offers a look at near-term prospects for the rational reoptimization of PPC bioexcitons for new functions using site-directed mutagenesis. The primary focus is on the "structure-spectrum" challenge of understanding the relationships between structural features and spectroscopic properties. While recent examples demonstrate that site-directed mutagenesis can be used to tune nearly all key bioexciton parameters (e.g., site energies, inter-pigment couplings, and electronic-vibrational interactions), critical challenges remain before we achieve truly rational design of bioexciton properties.

09 BIOMASS FUELS↗

High-entropy 1D halide perovskite piezoelectrics found by megalibrary synthesis and rapid nonlinear optical screening

Piezoelectric molecular crystals offer excellent compositional and structural tunability and sustainable processability. However, their discovery is slow, primarily due to the serial synthesis and screening processes used. Here, we report an approach that combines massively parallel megalibrary synthesis with scanning second harmonic generation (SHG) microscopy for rapid screening of piezoelectric molecular crystals. Megalibraries consisting of more than 1,000,000 compositionally distinct but positionally encoded TMCM x TMA (1–x) Cd y Pb (1–y) ClzBr (3–z) (TMCM: trimethylchloromethylammonium, TMA: tetramethylammonium; 0 ≤ x ≤ 1, 0 ≤ y ≤ 1, 0 ≤ z ≤ 3) nanocrystals were synthesized. The megalibraries were rapidly screened by SHG microscopy to identify notable noncentrosymmetric structures, which were then tested for piezoelectricity, facilitating discovery of a high-entropy noncentrosymmetric material with a large d 33 (TMCM 0.75 TMA 0.25 Cd 0.75 Pb 0.25 Cl 1.5 Br 1.5 , 42.8 picocoulombs per newton). Furthermore, this approach enabled systematic investigation of the Curie temperature (T C )–composition relationship in the TMCMCdCl z Br (3–z) system, facilitating reverse design of materials with targeted T C . Our work establishes a powerful approach to accelerate the discovery and design of unusual piezoelectrics for next-generation electronics and optics.

Li, Jun [Northwestern University, Evanston, IL (Un↗

Neuromorphic Information Processing by Optical Media

Classification of features in a scene typically requires conversion of the incoming photonic field int the electronic domain. Recently, an alternative approach has emerged whereby passive structured materials can perform classification tasks by directly using free-space propagation and diffraction of light. In this manuscript, we present a theoretical and computational study of such systems and establish the basic features that govern their performance. We show that system architecture, material structure, and input light field are intertwined and need to be co-designed to maximize classification accuracy. Our simulations show that a single layer metasurface can achieve classification accuracy better than conventional linear classifiers, with an order of magnitude fewer diffractive features than previously reported. For a wavelength λ, single layer metasurfaces of size 100λ x 100λ with aperture density λ -2 achieve ~96% testing accuracy on the MNIST dataset, for an optimized distance ~100λ to the output plane. This is enabled by an intrinsic nonlinearity in photodetection, despite the use of linear optical metamaterials. Furthermore, we find that once the system is optimized, the number of diffractive features is the main determinant of classification performance. The slow asymptotic scaling with the number of apertures suggests a reason why such systems may benefit from multiple layer designs. Finally, we show a trade-off between the number of apertures and fabrication noise.

47 OTHER INSTRUMENTATION↗

Molar Absorptivities of U(VI), U(IV), and Pu(III) in Nitric Acid Solutions of Various Concentrations Relevant to Developing Nuclear Fuel Recycling Flowsheets

Testing of a co-decontamination (CoDCon) tributyl phosphate (TBP) based solvent extraction flowsheet is being performed to optimize conditions for achieving a target U/Pu ratio in the Pu-containing product. The flowsheet is designed to directly produce a mixture of U and Pu with a U/Pu mass ratio of 7/3. The system is monitored in real time using optical spectroscopy, which allows for control of the U/Pu ratio in the aqueous U/Pu nitrate product. On-line spectrophotometric monitoring of the aqueous stream at the reductive stripping step involves determination of U(VI), U(IV) and Pu(III) concentrations and relies on molar absorptivities of these species in nitric acid at a number of wavelengths corresponding to their peaks’ maxima. The magnitudes of these molar absorptivities are a sensitive function of nitric acid concentration and have to be determined as precisely as possible using an off-line spectrophotometry under well controlled conditions. This step (called training set acquisition) is typically performed not in a high contamination area of radiological glovebox where flow-through cells and other on-line equipment are installed but in a less aggressive environment of a radiological fume hood with much better control of stock solutions quality, dilution factors, optical absorbance scale calibration, etc. This is followed by the calibration transfer between the off-line instrument and the instrument deployed during extraction and stripping runs. This paper reports values of molar absorptivities of U(VI), U(IV), and Pu(III) in nitric acid solution of 0.5 M to 4 M concentration and compares them with available technical literature data. Results of off-line spectrophotometric analysis of selected aqueous grab samples from one of CoDCon runs show satisfactory agreement with total uranium and plutonium concentrations determined in the same samples by ICP-MS.

Sinkov, Sergey I.↗

Multi-spatio-temporal scales PIV in a turbulent buoyant jet discharging in a linearly stratified environment

Time-resolved particle image velocimetry is implemented with a camera array and several laser sheets; this results in a multi-spatio-temporal scale system that is modular and flexible. The setup is optimized to capture global flow features, while locally resolving in space and time near the Kolmogorov scale. The apparatus relies extensively on machine vision CMOS cameras; they are inexpensive and stream to computer hard drive with virtually continuous time-resolved records (up to one hour for the current system). This leads to statistically converged data and also helps in minimizing down time between experimental runs. Details of the implementation and design of experiment are reported. The system instruments a vertical buoyant jet discharging in a linearly stratified environment. Refractive index matched aqueous solutions enable precise optical deployment. The density difference is 3% and the fluids have similar dynamic viscosity. The jet Reynolds number is 2.00 x 10 4 and is above the mixing transition. Such flows are typically challenging to instrument and few velocity field data are available to date. The velocity statistics are reported as well as first insights gained from the campaign.

42 ENGINEERING↗

Innovative laser-based methods for monitoring fuel retention in ITER

This paper addresses the challenge of tritium inventory management in ITER and future fusion reactors, highlighting the importance of accurate tritium measurement and its spatial distribution within the vacuum vessel. Given ITER’s operational constraints, especially the limit on tritium retention, precise measurement is essential for both safety and regulatory compliance. To tackle these questions, the paper presents the T-monitor diagnostic system developed by Forschungszentrum Jülich, which uses Laser-Induced Desorption (LID) in combination with Diagnostic Residual Gas Analysis (DRGA) to measure hydrogen isotope concentrations on the surface of divertor tiles. The system integrates a high-power laser, advanced optical components, and a Fast Scanning Mirror Unit (FSMU) for accurate laser spot positioning with rapid response. Designed to measure in situ tritium retention, the diagnostic provides high-resolution spatial mapping, vital for evaluating detritiation strategies. The laser heating process increases the divertor surface temperature to 1600 K within the laser spot, promoting hydrogen isotope desorption. Accurate measurements require the precise control of laser parameters, including pulse duration and spot size, with a target relative accuracy of 20%. The optical design includes both in-vessel and ex-vessel components, such as durable high-reflectivity mirrors made of gold and copper, selected not only for their infrared performance but also for their transmission of visible wavelengths for observation purposes. To protect optical components from contamination, a pneumatic shutter is used.

Hydrogen isotopes↗

Multiparameter optical fiber sensing for energy infrastructure through nanoscale light–matter interactions: From hardware to software, science to commercial opportunities

Monitoring of energy infrastructure through robust yet economical sensing platforms is becoming an area of increased importance, with ubiquitous applications including the electrical grid, natural gas and oil transportation pipelines, H2 infrastructure (storage and transportation), carbon storage, power generation, and subsurface environments. Plasmonic and functional nanomaterial enabled fiber optic sensors show excellent promise for a wide range of sensing applications due to their versatility to be engineered for specific analytes of interest while retaining inherent advantages of the optical fiber sensor platform. Through the design of novel sensing layers, the optical transduction mechanism and wavelength dependence can also be tailored for ease of integration with low-cost interrogation systems enabling an inexpensive yet highly functional optical fiber sensing platform. In addition, recent advances in artificial intelligence and machine learning theoretical methods have been leveraged to simultaneously extract multiple parameters through multi-wavelength interrogation such that unique wavelengths can also serve as unique sensing elements, analogous to electronic nose sensor technologies. The concept of an optical fiber based “photonic nose” via multiple interrogation wavelengths and/or sensor nodes offers a compelling platform technology to realize multiparameter speciation of chemical analytes within complex gas mixtures. In this Perspective, we further generalize the notion of multiparameter sensing through the novel “photonic nervous system” concept based upon low-cost, functionalized optical fiber sensor probes monitoring a variety of distinct analyte classes (physical, chemical, electromagnetic, etc.) simultaneously to provide broad situational awareness via integrated sensors.

Su, Yang-Duan (ORCID:0000000214820902)↗

Optimization and Prediction of Spectral Response of Metasurfaces Using Artificial Intelligence

Hot-electron generation has been a topic of intense research for decades for numerous applications ranging from photodetection and photochemistry to biosensing. Recently, the technique of hot-electron generation using non-radiative decay of surface plasmons excited by metallic nanoantennas, or meta-atoms, in a metasurface has attracted attention. These metasurfaces can be designed with thicknesses on the order of the hot-electron diffusion length. The plasmonic resonances of these ultrathin metasurfaces can be tailored by changing the shape and size of the meta-atoms. One of the fundamental mechanisms leading to generation of hot-electrons in such systems is optical absorption, therefore, optimization of absorption is a key step in enhancing the performance of any metasurface based hot-electron device. Here we utilized an artificial intelligence-based approach, the genetic algorithm, to optimize absorption spectra of plasmonic metasurfaces. Using genetic algorithm optimization strategies, we designed a polarization insensitive plasmonic metasurface with 90% absorption at 1550 nm that does not require an optically thick ground plane. We fabricated and optically characterized the metasurface and our experimental results agree with simulations. Finally, we present a convolutional neural network that can predict the absorption spectra of metasurfaces never seen by the network, thereby eliminating the need for computationally expensive simulations. Our results suggest a new direction for optimizing hot-electron based photodetectors and sensors.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Designing ITER motional Stark effect line shift (MSE-LS) spectrometers

As a part of ITER beam aided diagnostics, the design of Motional Stark Effect (MSE) diagnostic observing the emission from the Balmer-α line is underway. The physics of Stark splitting shows that the Stark manifold is polarization dependent, and the energy splitting results in a line shift proportional to the electric field. Due to the challenges of maintaining the calibration of the plasma facing mirrors in ITER, the conventional MSE polarimetry measurement technique is replaced with a spectral approach that is deemed more favorable in the ITER environment. The MSE line shift (LS) diagnostic is designed to quantify the Lorentz electric field magnitude by measuring the Stark manifold using visible spectroscopy. In the presence of large magnetic fields and high energy heating beams of 1 MeV, the expected Stark splitting is much larger than in typical devices. The MSE-LS design has unique challenges requiring careful consideration and modeling of its viewing geometry and photon budget. The MSE-LS approach on ITER is promising but has stringent demands on the allowable errors for the statistical and systematic fitting uncertainties. In this study, a full system model and numerical simulations of data for each sightline are completed. For a range of optical transmission fractions, photon noise analysis is conducted to determine the statistical uncertainties. This provides guidance on the spectrometer throughput, dispersion at the detector, optics, and other design choices. A conceptual design of a high throughput spectrometer with a volume phase transmission grating is presented.

Instruments & Instrumentation↗

Core-shell metallic alloy nanopillars-in-dielectric hybrid metamaterials with magneto-plasmonic coupling

Combining plasmonic and magnetic properties, namely magneto-plasmonic coupling, inspires great research interest and the search for magneto-plasmonic nanostructure becomes considerably critical. In this work, we designed a nanopillar-in-matrix structure with core–shell alloyed nanopillars for both BaTiO 3 (BTO)-Au 0.5 Co 0.5 (AuCo) and BTO-Au 0.25 Cu 0.25 Co 0.25 Ni 0.25 (AuCuCoNi) hybrid systems, i.e., ferromagnetic alloy cores (e.g., Co or CoNi) with plasmonic shells (e.g., Au or Au/Cu). These core–shell alloy nanopillars are uniformly embedded into a dielectric BTO matrix to form a vertically aligned nanocomposite (VAN) structure. Both hybrid systems present excellent epitaxial quality and interesting multi-functionality, e.g., high magnetic anisotropy, magneto-optical coupling response, tailorable plasmonic resonance wavelength, tunable hyperbolic properties and strong optical anisotropy. These alloyed nanopillars-in-matrix designs provide enormous potential for complex hybrid material designs with multi-functionality and demonstrate strong interface enabled magneto-plasmonic coupling along with plasmonic and magnetic performance.

36 MATERIALS SCIENCE↗